| Sl No | Description | Qty | Unit | MS JAIN PAINT AND HARDWARE STORE L2 | V R TRADERS L6 | M/S BSS AND SONS L5 | Vinod Kumar Bajaj L3 | GOURAV M ENTERPRISES L7 | NAV DURGA CONSTRUCTION CO L1 | SHARMA ARCHITECT L8 | mehar buildcon L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing to low lying area within station where directed complete all as specified | 36.5 | Cum | 380 ₹13,870 | 300 ₹10,950 | 250 ₹9,125 | 100 ₹3,650 | 400 ₹14,600 | 400 ₹14,600 | 370 ₹13,505 | 290 ₹10,585 |
| 2.00 | Water proofing treatment to sunken slab and adjjoining vertical surfaces as specified under :-
(a) Cleaning of sunken portion and roughening to receive treatment.
(b) M&L rendering 10 mm thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compound trowel even and smooth with steel trowel on sunken surfaces
(Note : WPC shall be measured and paid separately)
(c) Applying first coat of chemical pidifin 2K(Dr Fixit) on cleared RCC surfaces @ 0.86 Kg/Sqm (Minimum) as recommended by manufacturer.
(d) Provide a layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturers recommendation.
(e) Applying second coat of chemical Pidifin 2K (Dr Fixit)/ equivalent @ 0.86 Kg/Sqm (minimum) layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturers.
Note: The plan area of floor shall be considered for payment | 35 | Sqm | 1,150 ₹40,250 | 1,300 ₹45,500 | 1,500 ₹52,500 | 1,450 ₹50,750 | 1,230 ₹43,050 | 1,200 ₹42,000 | 1,120 ₹39,200 | 1,200 ₹42,000 |
| 3.00 | M&L for PCC 1:5:10, type E-2 as in filling of sunken floors etc. complete all as specified and directed | 14 | Cum | 2,600 ₹36,400 | 3,000 ₹42,000 | 2,500 ₹35,000 | 2,500 ₹35,000 | 2,700 ₹37,800 | 2,400 ₹33,600 | 3,000 ₹42,000 | 2,950 ₹41,300 |
| 4.00 | M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) with WPC under floor over sunken complete all as specified and directed | 35 | Sqm | 250 ₹8,750 | 200 ₹7,000 | 450 ₹15,750 | 450 ₹15,750 | 300 ₹10,500 | 230 ₹8,050 | 240 ₹8,400 | 200 ₹7,000 |
| 5.00 | M&L for PCC (1:3:6) type C-2 (using 40mm graded aggregate) 75mm thick as in plinth protection including making grooves complete all as specified | 300 | Sqm | 250 ₹75,000 | 300 ₹90,000 | 400 ₹1.2 L | 350 ₹1.1 L | 280 ₹84,000 | 280 ₹84,000 | 265 ₹79,500 | 210 ₹63,000 |
| 6.00 | Demolition of RCC of any description such chajja, shelves etc and in any position not otherwise specially provided for and removing waste material to low lying area within station where directed complete all as specified and directed by Engineer-in-Charge | 1.5 | Cum | 650 ₹975 | 700 ₹1,050 | 450 ₹675 | 550 ₹825 | 700 ₹1,050 | 500 ₹750 | 690 ₹1,035 | 520 ₹780 |
| 7.00 | M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) as in Slab supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and etc. and setting in mortar complete with joints to match complete all as specified | 1.5 | Cum | 9,200 ₹13,800 | 10,000 ₹15,000 | 9,000 ₹13,500 | 9,500 ₹14,250 | 9,500 ₹14,250 | 8,500 ₹12,750 | 9,600 ₹14,400 | 8,650 ₹12,975 |
| 8.00 | M&L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified | 100 | Kg | 102 ₹10,200 | 120 ₹12,000 | 90 ₹9,000 | 120 ₹12,000 | 115 ₹11,500 | 100 ₹10,000 | 120 ₹12,000 | 98 ₹9,800 |
| 9.00 | Use and waste of form work through finished surfaces of soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick complete all as specified | 10 | Sqm | 650 ₹6,500 | 700 ₹7,000 | 650 ₹6,500 | 700 ₹7,000 | 680 ₹6,800 | 600 ₹6,000 | 700 ₹7,000 | 620 ₹6,200 |
| 10.00 | Taking up or down GI/CPVC/any other tubing 15mm bore pipe incl removing to MES store complete all as specified. | 120 | RM | 35 ₹4,200 | 60 ₹7,200 | 30 ₹3,600 | 40 ₹4,800 | 45 ₹5,400 | 30 ₹3,600 | 40 ₹4,800 | 30 ₹3,600 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Nov 2025, 6:00 pmClosed
GE FARIDKOT
GE FARIDKOT MIL STN
REPAIR REPLACEMENT OF SANITARY FITTING PLUMBING WORK AND OTHER CONNECTED WORKS UNDER AGE B R M AT FARIDKOT MIL STN
2025_MES_738964_1
GE FRD-26/2025-26
Open Tender
Civil Works
180 days
GE FARIDKOT
Class D a i
9 documents required · 9 mandatory
₹500
GE FARIDKOT
₹90,000
Yes
19 Jan 2026
8 Nov 2025
29 Nov 2025
8 Nov 2025
27 Nov 2025
22 Nov 2025
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing to low lying area within station where directed complete all as specified
Water proofing treatment to sunken slab and adjjoining vertical surfaces as specified under :- (a) Cleaning of sunken portion and roughening to receive treatment. (b) M&L rendering 10 mm thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compound trowel even and smooth with steel trowel on sunken surfaces (Note : WPC shall be measured and paid separately) (c) Applying first coat of chemical pidifin 2K(Dr Fixit) on cleared RCC surfaces @ 0.86 Kg/Sqm (Minimum) as recommended by manufacturer. (d) Provide a layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturers recommendation. (e) Applying second coat of chemical Pidifin 2K (Dr Fixit)/ equivalent @ 0.86 Kg/Sqm (minimum) layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturers. Note: The plan area of floor shall be considered for payment
M&L for PCC 1:5:10, type E-2 as in filling of sunken floors etc. complete all as specified and directed
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) with WPC under floor over sunken complete all as specified and directed
M&L for PCC (1:3:6) type C-2 (using 40mm graded aggregate) 75mm thick as in plinth protection including making grooves complete all as specified
Demolition of RCC of any description such chajja, shelves etc and in any position not otherwise specially provided for and removing waste material to low lying area within station where directed complete all as specified and directed by Engineer-in-Charge
M&L for reinforced cement concrete type B1 1:2:4 (20 mm graded aggregate) as in Slab supported on walls, beams and column in floors, roofs, landings, balconies, deck slabs and in shelves and etc. and setting in mortar complete with joints to match complete all as specified
M&L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified
Use and waste of form work through finished surfaces of soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick complete all as specified
Taking up or down GI/CPVC/any other tubing 15mm bore pipe incl removing to MES store complete all as specified.
Taking up or down GI/CPVC/any other tubing 20mm bore pipe incl removing to MES store complete all as specified.
Taking up or down GI/CPVC/any other 25 mm bore pipe including or removal to store complete all as specified.
Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings and all other Brass fittings required except given in item number 18,19,20 & 21 on walls/ceiling or laying in floors complete including cutting chases in wall, floors etc and their making good in case of concealed pipe work bore of pipe 20mm complete all as specified and directed by Engr-in-Charge
S&F GI tubing 15 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, including cutting chases in wall, floors etc and their making good in case of concealed pipe work complete all as specified.
S&F GI tubing 20 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, including cutting chases in wall, floors etc and their making good in case of concealed pipe work complete all as specified.
All as per Srl Item No. 15 here-in-before but refixing 20 mm dia ,old steel tubing and connections in new or old position (wall, ceiling and floors etc)
S&F GI tubing 25 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified.
S&F of 20 mm inner dia CPVC Brass Male/ Female Brass Threaded Adaptor fittings complete all as specified.
S&F of 20 mm inner dia CPVC Brass Elbow fittings complete all as specified
S&F of 20 mm inner dia CPVC Brass T fittings complete all as specified
S&F of 20 mm inner dia CPVC Brass Union fittings complete all as specified
M&L for Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles15mm thick screed bed or bedding layer CM 1:4 for laying finishes, complete all as specified as directed by Engr-in-Charge
M&L for Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles15mm thick screed bed or bedding layer CM 1:4 for laying finishes, complete all as specified as directed by Engr-in-Charge
M&L for Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, cut to reqd size and shape as in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 10mm thick rendering in CM 1:4 complete all as specified as directed by Engr-in- Charge
M&L for Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles15mm thick screed bed or bedding layer CM 1:4 for laying finishes, complete all as specified as directed by Engr-in- Charge
M&L for Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.36 sqm, cut to reqd size and shape as in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 10mm thick rendering in CM 1:4 complete all as specified and directed
M&L for Glazed ceramic coloured designer tiles with highlighter in vertical surface 450x300x7mm or 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 15 mm thick rendering in CM 1:4 on other than fair face of brick work complete all as specified. (Highlighter shall be provided as directed by Engr-in-Charge)
Dismantling floor, hearth or wall tiling including cement mortar bedding, terrazo dado/wall tiling and skirting etc. on brick or stone walls etc. including racking out joints hacking for key and scrubbing and removing debris to low lying area within station where directed complete all as specified
Dismantling stone slabs of any description or thickness in floors, apron etc laid bedded and pointed in any mortar and removing debris to low lying area within station where directed complete all as specified
M&L for Granite (of any type) work 15 to 17 mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified
S&F in repair Rotational moulded polythylene 500 ltr capacity water storage tank (Cylindrical vertical with closed top) white colour, hoisted and fixed in position including 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. & dismantling of old water tank and removing to MES store complete all as specified
S&F in repair Rotational moulded polythylene 1000 ltr capacity water storage tank (Cylindrical vertical with closed top) white colour, hoisted and fixed in position including 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed & dismantling of old water tank and removing to MES store complete all as specified
S&F in repairs 20mm gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
S&F in repair 15 mm bore chromium plated angle valve of cast copper alloy screwed down high pressure with on/off handle screwed both ends for iron pipe or for unions and fixed all as specified and directed
S&F in repair 15 mm bore chromium plated stop valve of cast copper alloy with long shank and cup (concealed type) ends for iron pipe or for unions and fixed all as specified and directed
S&F PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality complete all as specified
S&F in repair vitreous china wash hand basin, white, flat back of size 550mm x 400mm including cantilever CI/angle iron brackets, CP brass waste coupling 32mm bore with rubber washer and PVC waste pipe 32mm bore complete all as specified and directed
S&F in repair vitreous china counter wash basins, size 470x470mm white to be fixed with and incl granite & RCC slab including cutting for and pinning in ends of brackets or erecting stand, including 32mm waste fittings, waste pipe, chromium plated with long screwed shanks & fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified
S&F in repairs vitreous China one piece WC (Floor mounted or wall hung type) of approved make including soft close seat cover complete all as specified
S&F in repairs vitreous China squatting pan or Orrissa pattern of approved make of size 580 mm X 440mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl concrete bedding and connection to anti-syphonage pipe etc including making good to floor complete all as specified
S&F in repairs vitreous China EWC wash down water closet (Pedestal pattern) incl seat cover incl connection to trap and to flushing pipe etc complete all as specified
M&L for 100 mm dia of long body PVC 'P' or 'S' trap including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 in repair complete all as specified.
S&F PVC low level cistern of 10 ltrs capacity with top push button inclusive of brackets and PVC bend long type and connecting to flush pipe of any size and pattern with inlet ball valve float and handle complete of approved make complete all as specified
Taking down rain water pipe and eaves gutters (any size and pattern) including all fittings heads shoes bends swan necks etc including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified
Dismantling and disconnecting existing CI / PVC soil waste/vent pipe 100/75 mm bore fixed to wall, laid in trenches incl all fittings & accessories and removing debris to low lying area within station where directed and scrap to MES store complete all as specified
S&F 110 mm bore of pipe PVC (SWR) pipes heavy grade single socket in any length with rubber ring joint laid in floor/trench or fixed to walls with and incl double side suspension clamps (DSS)of make Shaivi or equivalent in other brand of size 25mmx1.5mm made of galvanised carbon steel and having noise absorbing silicon rubber sleeve. Clamps to be fixed to wall with anchor fastner with nut and washer and full threaded bar of size 10m Distance of two clamps should not be more than 1.00m complete all as specified and directed
All as per Srl Item No. 49 here-in-before but for 75mm bore pipe
S&F 110 mm bore PVC (SWR) bends heavy grade of any radius / shoe fixed to PVC pipes complete all as specified and directed
S&F 75 mm bore of pipe PVC (SWR) bends heavy grade of any radius / shoe fixed to PVC pipes complete all as specified and directed
M&L for 75mm dia of long body PVC Floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 in repair complete all as specified
M&L for PVC (SWR) branch piece, single (single Y), 75 mm bore, (equal or unequal), complete all as specified and directed by Engineer-in-Charge
M&L for PVC (SWR) branch piece, single (single Y), 100 mm bore, (equal or unequal), complete all as specified and directed by Engineer-in-Charge
M&L for PVC (SWR) junction single, (Single T), 75 mm bore, (equal or unequal), ordinary or inverted (spigot or socket type) or with oval access door as in repairs complete all as specified and directed by Engineer-in-Charge
M&L for PVC (SWR) junction single, (Single T), 100 mm bore, (equal or unequal), ordinary or inverted (spigot or socket type) or with oval access door as in repairs complete all as specified and directed by Engineer-in-Charge
S&F in repairs PVC (SWR) vent cowl 100 mm complete all as specified and directed
S&F Salt-glazed stoneware gully traps 150x 150 mm , square or round mouthed, type 'P’ complete all as specified
S&F 100 mm bore cast iron soil waste and vent pipes in any length with or without ears, with cement joints, laid in floor or fixed to walls with and incl MS clamps complete all as specified
S&F 75 mm bore cast iron soil waste and vent pipes in any length with or without ears, with cement joints, laid in floor or fixed to walls with and incl MS clamps complete all as specified
S&F 100 mm bore CI bend (any radius), diminishing piece or tapers with or without oval access door complete all as specified
S&F 75 mm bore CI bend (any radius), diminishing piece or tapers with or without oval access door complete all as specified
S&F 100 mm bore CI branch piece, Tee, Cross (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with or without oval access door complete all as specified and directed by Engineer-in-Charge.
S&F 75 mm bore CI branch piece, Tee, Cross (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with or without oval access door complete all as specified and directed by Engineer-in-Charge.
S&F in repair 125 mm dia round / square grating of stainless steel with or without hole with white cement complete all as specified & directed by Engineer-in-Charge
Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc and removing debris to low lying area within station where directed complete.
M&L for rendering 12mm thick in cement mortar 1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & fair complete all as specified
M&L for rendering 15mm thick in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and fair cement all as specified and directed
M&L for rendering 5mm thick in cement mortar in 1:3 on ceiling all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion white/ tinted over a coat of wall care putty finished even and smooth surface by hand roller complete all as specified and directed by Engr-in-Charge
M&L for preparation of surfaces and applying two coat of white wash on newly plastered surface of ceiling etc complete all as specified.
M&L for preparation of old decorated surfaces of existing treatment such as white wash, colour wash, synthetic enamel paint etc of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and filling in depressions to make smooth surface and applying two coat of cement base paint complete all as specified. Note :- Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I
Dismantling of brick work built in cement mortar of any description complete all as specified and directed by Engineer-in-Charge
M&L for brick work with Fly ash bricks straight or curved on plan exceeding 6 mtr mean radius in cm 1:6 etc. complete all as specified and directed by Engineer-in-Charge
MS JAIN PAINT AND HARDWARE STORE (BID ID -3482730)
Vinod Kumar Bajaj (BID ID -3484186)
mehar buildcon (BID ID -3483913)
M/S BSS AND SONS (BID ID -3484160)
V R TRADERS (BID ID -3484133)
GOURAV M ENTERPRISES (BID ID -3483585)
SHARMA ARCHITECT (BID ID -3483724)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
TenderDocuments26.pdf
Tender Documents • 0.83 MB
BOQ_827435.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid