| 1 | L1₹36.9 LAccepted-AOC PLOT NO 76 CIV SOCIETY MUKUND NAGAR AHMEDNAGAR 414001 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414001 | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹38.9 L+₹1.6 L (4.39%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹40.1 L+₹2.8 L (7.62%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹41.5 L+₹4.3 L (11.5%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹42.1 L+₹4.9 L (13.2%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹40.7 L
EMD Value
₹81,400
Closing Date
19 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provision of certain sanctioned works (11) in the area of AGE B/R I under GE (N) Ahmednagar
2022_MES_509675_1
8596 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹81,400
Yes
4 Apr 2022
22 Feb 2022
21 Mar 2022
22 Feb 2022
19 Mar 2022
7 Mar 2022
60 days
Amount
Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortar ,wall tiling etc complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames nexc 1.5 Sq m with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge.
Taking down shutter exceeding 1.00 Sqm but not exc 2 Sqm etc complete all as specified and directed by Engineer-in-Charge.
Taking down steel windows/ventilator n exc 1.5 Sqm,any size with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing and connections,15 mm bore etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 7 (here-in-before) but 20mm bore.
M & L for special treatment to sunken slab floor incl WC trap etc including cleaning and preparing the surface area for carrying out membrane water proofing treatment and applying 10mm thick cement plaster in cement and sand mortar (1:4). Then providing and laying Mineral Top APP (Atactic Polypropylene Polymer) modified prefabricated 5 layer 4mm thick water proofing membrane, black finished rainforce with non woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Litre per Sqm by the same membrane manufacturer of density at 25ºC, 0.87-0.89 Kg per litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torach and sealing all joints etc and preparing the surface complete. and providing PCC (1:5:10) type E2 using 40mm graded mechanically crushed stone aggregates in sunken slab and 75mm thick PCC (1:4:8) type D2 using 40mm graded mechanically crushed stone aggregates as base, 40mm bore GI pipe, light grade of length not less that 50 cm as spout, area of toilet/bathroom exc 1.50 Sqm but nexc 5.00 Sqm etc after dismantling the existing sunken floor etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair pressed steel frames (thickness of sheet 1.25 mm) of size 125mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc incl filling in door frames in plain cement concrete, 1:2:4 type B0, using 12.5 mm graded stone aggregate etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 35 mm thick factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial plywood. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 35 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Factory Made Solid PVC Moulded Door Shutter, with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face, the shutter shall be fixed with and including stainless steel hinges 100mm size etc complete all as specified and directed by Engineer-in-Charge.
S&F powder coated anodised aluminium glazed window/ventilator shutter fixed / sliding type, without sash bars, aluminium sections weighing 0.55 kg/m aluminium open track section having reqd size of style and top rails, bottom rails including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.), etc complete all as specified and directed by Engineer-in-Charge. (Glass shall be measured and paid seperatly as S&F in respective item of this BOQ)
S&F mild steel barrel tower bolt 200mm long , stove enamelled black, with bright bolt etc complete all as specified and directed by Engineer-in-Charge.
S&F mild steel sliding door bolts 300mm long , plate type stove enamelled black with bright bolts not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel pressed handles 150mm long , oval type , stove enamelled black etc complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long butt hinge, medium weight, stainless steel etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair MS 300mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 200mm long aluminium anodised barrel tower bolt of extruded section etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 150mm long aluminium anodised handles of extruded section etc complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness size,quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads etc complete all as specified and directed by Engineer-in-Charge.
M & L for 3mm thich figured glass pin headed type glazing with oil putty, bead in squares n.exc 0.50 Sqm Each etc complete all as specified and directed by Engineer-in-Charge.
M & L for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 Sqm in Each pane etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair wire cloth 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples etc complete all as specified and directed by Engineer-in-Charge.
M & L for coloured glazed ceramic tiles of size exc 0.06 Sqm and n'exc 0.18 Sqm , 8-10 mm thick as approved by GE as in dado/skirting or on vertical surfaces, over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of Each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of floor etc complete all as specified and directed by Engineer-in-Charge.
M & L 16-18mm thick pre-polished granite stone slab of approved shade and colour Jet Black / Telephone Black as in top table, top of WHB, kitchen slab/platform, steps, gate pillars, cills etc or on vertical surfaces including vertical projection, full round moulding the edge laid over screed bed 15mm thick in cement and sand mortar (1:4) jointing , pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite and rubbing polish to achieve mirror finish etc complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut kota stone slab flooring 20-25mm thick over and including 15mm thick cement screed bedding in cement and sand mortar (1:6) laid and jointed in neat cement slurry & pointed with pigment to match shade of kota stone including rubbing and mirror polishing etc complete all as specified and directed by Engineer-in-Charge.
S&F of kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 10mm thick screed bed in cement and sand mortar (1:4) rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge.
M & L for machine cut cudappah stone slab 18-20 mm thick, laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge.
M & L for rendering, 10 mm thick on ceiling surfaces in cement and sand mortar (1:4) surfaces finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick in cement and sand mortar (1:6) on brick or concrete surface/ stone surfaces finishing even and smooth with thin layer of sagol finish etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering to 15 mm thick in cement and sand mortar (1:4) on brick/concrete/stone surfaces etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix tubular towel rail, brass chromium plated 60 cm long between flanges including a pair of brackets etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistren etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs vitreous china wash down water closet (Pedestal pattern) white including fixing bolts with and including plastic water closet seat cover closed pattern with flat bottom and cover and MSCP almn hinges device complete connecting to 'P' or 'S' trap etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including conncetion to flushing pipe and waste pipe providing and fixing plugs bedding urinal against wall etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair health faucet with 8 mm dia 1 m long flexible tube wall mounted / hooked etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs PVC valveless, syphonic action type, flushing cistern,low level, all accesories etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair bib tap, 15 mm dia, CP cast copper alloy screwed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs stop valve cast copper alloy, fancy type screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs single flow 100 mm dia shower rose with shower arm etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 15 mm bore galvanised steel tubing medium grade laid in trenches or fixed to walls / ceiling etc complete all as specified and directed by Engineer-in-Charge.
All as per items ser No 45 (here-in-before) but 20mm bore.
Supply and fix in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs, chromium plated grating 100 mm dia of PTMT etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs 75mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with stack clamps FI 50mm by 5mm flat iron clamps to walls incl bolt & nuts etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 50 (here-in-before) but 110 mm dia.
Supply and fix in repairs PVC (SWR) bends any radius, for 75mm bore of pipe with access door etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 52 (here-in-before) but 110 mm dia.
S&F 110 mm bore PVC (SWR) vent cowl etc complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) branch piece double (single/double Y) equal or unequal etc complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore PVC (SWR) branch piece double (single/double Y) equal or unequal etc complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of acrylic antifungal paint on plastered surfaces including preparation on walls etc complete all as specified and directed by Engineer-in-Charge.
M&L for two coats of synthetic enamel paint over a coat of pink primer for new wooden surfaces of any description exc 10 cm width or girth including preparation of surfaces and smooth finish with roller etc complete all as specified and directed by Engineer-in-Charge.
M & L for two coats of synthetic enamel paint over a coat of red oxide primer for newly / untreated steel surfaces of any description exc 10 cm width or girth including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly / old plastered surface and applying 2 coats of white wash on wall etc complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new / old plastered surface and applying 2 coats of white wash on ceiling etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair nahani trap with 100 mm dia grating incl 75mm dia PVC bend to fixing with drain pipe and floor tiles on broken area n.exc 1.00 sqm area in kitchen or bathroom etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of water tanks from any position / location, of any make etc,of capacity exc 500 Ltr & n.exc 1000Ltr with ball valve, etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix rotational moulded polyethylene water storage tanks double layer ISI marked conforming to IS 12701-1996 (cylindrical vertical with closed top) and made out of virgin FDA approved polyethylene material of 2000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting etc complete all as specified and directed by Engineer-in-Charge.
M&L for screed bed or bedding layer of mortar 10mm thick in CM 1:3 by using 100% course sand on roof/chajja mixed with & including M&L for WPC @ 3% by weight of cement and finished the surfaces even and smooth without using extra cement to receive water proofing treatment including taking down existing screed bed / plaster etc complete all as specified and directed by Engineer-in-Charge.
M&L for providing waterproofing treatment on roof / chajja / parapet etc. as per latest zonal specification, as per manufacturer's instructions and as specified after taking down / out as existing as site:- (a) M&L for cleaning the newly plastered surface with wire brushes and applying two coats of bituminous primer @ 0.25ltrs/sqm and allow to dry. (b) M&L for applying and laying torch APP polymer modified bituminous membrane 3mm thick with non woven polyster matt as reinforced weighing not less 3 kg / Sqm with white gravel / mineral finished by thermofusion process etc complete all as specified and directed by Engineer-in-Charge.
S & F Stainless steel kitchen plate rack made out of 0.63mm thick sheet of size ( 31"x 36' x 10') with complete acessories etc complete all as specified and directed by Engineer-in-Charge / approved by Engineer-in-charge
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site etc complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick Cement concrete type D-2, (1:4:8) (using 40mm graded stone aggregate) etc complete all as specified and directed by Engineer-in-Charge.
M & L for Complete removal of existing treatment on plastered and applying 2 mm thick wall care putty (birla) including crack filling and applying two of Oil bound distemper (OBD) etc complete all as specified and directed by Engineer-in-Charge.
S&F powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
S&F fixed in repairs Wash hand basin vitreous china (flat back) size 550 x 400 mm including brackets waste brass chromium plated with long screwed shanks and fly nuts 32 mm size including bottle trap etc complete all as specified and directed by Engineer-in-Charge.
S&F Pillar taps 15mm dia, cast copper alloy, with capstan heads, chromium plated, screwed own high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix rotational moulded polyethylene water storage tanks double layer ISI marked conforming to IS 12701-1996 (cylindrical vertical with closed top) and made out of virgin FDA approved polyethylene material of 1000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting etc complete all as specified and directed by Engineer-in-Charge.
S & F of ball brass valve, 20mm bore dia of pipe, high pressure with polythene float and flynet complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and directed by Engineer-in-Charge.
Supplied and fixed 20mm Bore dia of pipe gun metal and glob or gate valve with iron wheel head, screwed both ends for iron pipe etc complete all as specified and directed by Engineer-in-Charge.
M&L for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, in soft and loose soil returning,filling in and ramming earth or broken rubble mixed with earth around, removing surplus material n.exc 50 mtr and making good distrubed surface etc complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5m wide an d nexc. 1.5 m deep in for foundation etc getting out in hard dense soil etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type D2 using 40mm graded mechanically crushed stone aggregate as in foundation, mass concrete and sub-base etc complete all as specified and directed by Engineer-in-Charge.
M&L for Rolled section of structural steel work as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates conforming to Fe 410-W(gde-E-250) quality-A etc complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,fixed with self tapping screws etc complete all as specified and directed by Engineer-in-Charge.
S&F 0.56mm plain alumunium sheeting alloy 31000 H4 in ridges, hip, valley gutter, drip and straight flushing (length and girth as fixed) etc complete all as specified and directed by Engineer-in-Charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge.
M&L for machined pressed precast concrete interlocking paver block glossy with grey cement and pagment, any shpae and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over a stone dust cushion of 30mm thick etc complete all as specified and directed by Engineer-in-Charge.
M&L for Precast cement concrete block masonry with solid blocks, exc 10 cm in width and setting in cement and sand mortar (1:4) type C1 (1:3:6) etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:3:6) type C1 using 20 mm graded mechanically crushed stone aggregates as in cills, steps, bands, copings, bed plates, kerbs, hold fasts blocks etc including weathering slightly rounded or chamfered angles of throating including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix mild steel angle iron for posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix Mild steel bolts 10mm dia and 65 mm long purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut etc complete all as specified and directed by Engineer-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire etc complete all as specified and directed by Engineer-in-Charge.
Supply only chain link fencing made cut from GI wire 10 gauge and 50 mm apperture weight not less than 3 kg / Sqm etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 10 mm dia mild steel round bars to tighten chain link fencing including necessary hooking binding cutting etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for flat iron 40 x 6 mm cut to required length including drilling holes for fixing of nut and bolts to hold chain link fencing etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new surface of walls kerb stone and concrete surface & applying two coats of acrylic (antifungal) exterior grade paint on wall & etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair Self closing Push cock of cast copper alloy, screwed for Iron pipe chromium plated, cast copper alloy for brass ferrule etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair Brass Chromium Plated toilet paper holder fixed with (CP) brass screws etc complete all as specified and directed by Engineer-in-Charge.
S&F in 10 mm thick toughen glass for shelves in corner n'exc 0.06 Sqm etc complete all as specified and directed by Engineer-in-Charge.
Excavation over areas, exc 1.5m deep and 3.0 m wide and getting out in soil in for foundation etc getting out in Soft/hard dense soil etc complete all as specified and directed by Engineer-in-Charge.
Removing excavated surplus soil n.exc 50m deposiitng where directed at a level not exec 1.5m above the starting point etc complete all as specified and directed by Engineer-in-Charge.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping work in fair finished on flate surfaces etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 design mix using graded stone aggregate for slabs supported on walls and columns in floors, roof, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 40mm thick type B-1, (1:2:4) (20mm graded stone aggregate) floor etc complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel TMT bars 10 mm dia and over cut to length bent shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 103 (here-in-before) but 8 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for PCC (1:3:6), type C2 (using 40 mm graded stone aggregate) 75 mm thick as in Sub base/plinth protection etc complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm with soils etc complete all as specified and directed by Engineer-in-Charge.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings, ms plates, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 etc complete all as specified and directed by Engineer-in-Charge.
M&L for Galvanised, 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails including securing or tying with and provision of galvanised MS wire staples or steel pins etc complete all as specified and directed by Engineer-in-Charge.
M&L for chequred cement concrete tiles 20X20X25mm thick set jointed & pointed in neat cement slurry in floor with grey cement & pigment incl 15mm thick screed bed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
Form work to sides of concrete foundations, footings, bases of columns rafts and raft beams sides and sofits (if any) of foundation and plint beams and columns or similar work in fair finished surfaces etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M25 design Mix using graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams, columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in coloured cement to match the shade of floor etc complete all as specified and directed by Engineer-in-Charge.
Form work soffits of suspended slab such as roof slabs, floor slabs landings and similar work not exceeding 200mm thick horizontal or sloping in fair finished surfaces etc complete all as specified and directed by Engineer-in-Charge.
S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
All as per Item No 116 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board etc complete all as specified and directed by Engineer-in-Charge.
S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge.
S&F Switch socket combination two in one, 5 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge.
S&F Switch socket combination 5 Amp / 16Amp, five in one, 5 / 15 Amp 230V AC etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs, etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No: 5076 11 or equivalent in Simens/ Hager/ L&T
S & F in replacement double door Sheet metal enclosures factory made DBs 4 way SPN, 240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No:5076 10 or equivalent in Simens/ Hager/ L&T
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply and fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge Make:Philips Model Name Astra line or equvivalent in Crompton/Bajaj
Supply & fix replacemnt industrial type switch socket for Geyser/heater with 20 Amp MCB etc complete all as specified and directed by Engineer-in-Charge .Make L&T Cat No PMP120B/Havells/Schnider
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLSH stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-ChargeMake of FRLSH Cable.Havells/Polycab/Finolex Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Material and labour for preperation of surface of exhaust fans 450 mm sweep, of any make by cleaning of metal surfaces including painting with spray painting to required gloss with white synthetic enamel paint to complete body of fans and writing MES No with black paint etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge Make -Havell's Cat Part: (ENDURAPEARLSL25W MP) ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent makes mentioned in list of makes in Appendix `C'
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
Supply and fix exhaust fan,steel body AC Single phase,230 V of size 300 m sweep with ,blades frame and louvers.Make: Crompton/Bajaj/Havells
An amount of Rs 34,800.00 shall be deducted from BOQ on account of schedule of credit
M/s IBEX Engineers and Contractors
OM SAI ASSOCIATES
MS. G.A. CONSTRUCTION
M/s. A P INFRA
M/S. M. F. Sharif & Co.
M/s. Sagar Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .