| 1 | L1₹30.1 LAccepted-AOC A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹31.5 L+₹3,722.40 (0.12%)Rejected-Finance | L2 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 3 | L3₹33.7 L+₹2.2 L (6.95%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 4 | L4₹39.6 L+₹8.2 L (26.0%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L4 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 5 | L5₹41.6 L+₹10.1 L (32.1%)Rejected-Finance | L5 | Rejected-Finance BEING OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | NOEL ENGINEERS L3 | S S ENTERPRISES L1 | Shree Gajanan Enterprises L2 | ASHOK ENTERPRISES L4 | Angrahit Services Trading Co L5 | Chakshu Enterprise L7 | GANGAJAL L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting of electric connection from ceiling rose and taking down ceiling fan any type and any sweep from roof/wall of various buildings and shifting the same to MES store yard/ workshop, dismantling the same to check and assess the defect and reassembling the same after carrying out necessary repairs/ renewal of copper wire winding/defective parts inmcluding testing in E/M store yard and renewal of PVC insulated flexible twin core twisted copper conductor cable of size 23/.0076 and re-hanging/re-fixing and re-connecting the same complete all as specified and directed.
Note: (i) M & L for copper wire winding of fans, overhauling of fans and supply only of parts of fans shall be measured and paid separately under appropriate items. However, cost of PVC insulated flexible cable shall be deemed included in the unit rates of this item.
(ii) Labour Rates for 'Supply only items' shall deemed to be included in the quoted rate of this item. | 480 | Each Job | 50 ₹24,000 | 30 ₹14,400 Lowest | 123.54 ₹59,299.2 | 150 ₹72,000 | 100 ₹48,000 | 50 ₹24,000 | 217 ₹1,04,160 |
| 2.00 | Rewinding of ceiling fan any size 1200mm size as per IS-13730 using super enameled copper wire of same guage complete and directed. | 230 | Each Job | 450 ₹1,03,500 | 130 ₹29,900 Lowest | 282 ₹64,860 | 150 ₹34,500 | 300 ₹69,000 | 450 ₹1,03,500 | 555 ₹1,27,650 |
| 3.00 | Overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, and testing after refixing at site complete all as specified and as directed by Engr-in-Charge. Note: Canopy, bushes, bearing cap and down rod measured and paid separately. | 240 | Each Job | 120 ₹28,800 | 50 ₹12,000 Lowest | 274.8 ₹65,952 | 150 ₹36,000 | 300 ₹72,000 | 200 ₹48,000 | 105 ₹25,200 |
| 4.00 | Supply and fix Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet in provision for fixing complete all as required and as specified. | 450 | Each | 180 ₹81,000 | 100 ₹45,000 Lowest | 219 ₹98,550 | 200 ₹90,000 | 210 ₹94,500 | 300 ₹1,35,000 | 285 ₹1,28,250 |
| 5.00 | Supply only ceiling fan canopy suitable for 15mm dia rod with fixing Nuts and Bolts as approved by Engr-in-Charge. | 270 | Each | 9 ₹2,430 Lowest | 20 ₹5,400 | 13.8 ₹3,726 | 100 ₹27,000 | 50 ₹13,500 | 60 ₹16,200 | 275 ₹74,250 |
| 6.00 | Supply only gun metal bush suitable for any sweep fan of any make | 270 | Each | 8 ₹2,160 Lowest | 20 ₹5,400 | 12 ₹3,240 | 150 ₹40,500 | 30 ₹8,100 | 25 ₹6,750 | 110 ₹29,700 |
| 7.00 | Supply only capacitor 2.5Mfd. | 450 | Each | 24 ₹10,800 | 40 ₹18,000 | 21 ₹9,450 Lowest | 30 ₹13,500 | 100 ₹45,000 | 25 ₹11,250 | 65 ₹29,250 |
| 8.00 | Supply only ball bearing suitable for 230/300/380/450mm sweep Exhaust Fan. | 290 | Each | 32 ₹9,280 Lowest | 40 ₹11,600 | 66 ₹19,140 | 135 ₹39,150 | 150 ₹43,500 | 350 ₹1,01,500 | 125 ₹36,250 |
| 9.00 | Supply and Fix and replacement of 15mm dia clamp assembly with Nut, Bolts & rubber bush suitable for down rods and split pins as approved by Engr-in-Charge. | 290 | Each | 20 ₹5,800 | 20 ₹5,800 | 18 ₹5,220 Lowest | 120 ₹34,800 | 50 ₹14,500 | 120 ₹34,800 | 105 ₹30,450 |
| 10.00 | Supply and fixing ceiling fan down rod of length 300mm, inner diameter 15mm and thickness not less than 1.5mm with clamps Nuts, Bolts and washers for existing ceiling fan as approved by Engr-in-Charge | 250 | Each | 60 ₹15,000 | 30 ₹7,500 Lowest | 42 ₹10,500 | 150 ₹37,500 | 150 ₹37,500 | 100 ₹25,000 | 185 ₹46,250 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Nov 2025, 6:00 pmClosed
GE NW NAVY NAGAR
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD COLABA MUMBAI
REPAIR MAINT OF CEILING FAN EXHAUST FAN WITH CONNECTED ACCESSORIES INCLUDING SAFETY CHECKING OF CEILING FAN AND ELECTRICAL FITTINGS AND FIXTURE OF LOW RISE BUILDING UNDER GE NW NAVY NAGAR
2025_MES_735809_1
8540
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW NAVY NAGAR COLABA MUMBAI
CLASS D AND CATEGORY B(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR
₹90,000
27 Dec 2025
17 Oct 2025
10 Nov 2025
17 Oct 2025
7 Nov 2025
31 Oct 2025
17 Oct 2025 - 7 Nov 2025
Amount
Disconnecting of electric connection from ceiling rose and taking down ceiling fan any type and any sweep from roof/wall of various buildings and shifting the same to MES store yard/ workshop, dismantling the same to check and assess the defect and reassembling the same after carrying out necessary repairs/ renewal of copper wire winding/defective parts inmcluding testing in E/M store yard and renewal of PVC insulated flexible twin core twisted copper conductor cable of size 23/.0076 and re-hanging/re-fixing and re-connecting the same complete all as specified and directed. Note: (i) M & L for copper wire winding of fans, overhauling of fans and supply only of parts of fans shall be measured and paid separately under appropriate items. However, cost of PVC insulated flexible cable shall be deemed included in the unit rates of this item. (ii) Labour Rates for 'Supply only items' shall deemed to be included in the quoted rate of this item.
Rewinding of ceiling fan any size 1200mm size as per IS-13730 using super enameled copper wire of same guage complete and directed.
Overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, and testing after refixing at site complete all as specified and as directed by Engr-in-Charge. Note: Canopy, bushes, bearing cap and down rod measured and paid separately.
Supply and fix Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet in provision for fixing complete all as required and as specified.
Supply only ceiling fan canopy suitable for 15mm dia rod with fixing Nuts and Bolts as approved by Engr-in-Charge.
Supply only gun metal bush suitable for any sweep fan of any make
Supply only capacitor 2.5Mfd.
Supply only ball bearing suitable for 230/300/380/450mm sweep Exhaust Fan.
Supply and Fix and replacement of 15mm dia clamp assembly with Nut, Bolts & rubber bush suitable for down rods and split pins as approved by Engr-in-Charge.
Supply and fixing ceiling fan down rod of length 300mm, inner diameter 15mm and thickness not less than 1.5mm with clamps Nuts, Bolts and washers for existing ceiling fan as approved by Engr-in-Charge
Supply only ceiling fan blade (set of 3) suitable to any sweep and makes complete all as specified and as directed.
M & L for fabrication of fan hook made out of 12mm dia MS rod suitable for fan hook bend to shape 'S' including 12mm dia SS fastner as required at site and as directed by Engr in Charge.
M & L for preparing ceiling fan surfaces for painting by removing/cleaning dust and deposited material and applying one coats of white enamelled paint by spray to fan blades, body and down rod, canopy of ceiling fans complete all as specified and as directed.
Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified.
Disconnecting of electric connection from ceiling rose and taking down exhaust fan any type and any sweep from wall of various buildings and shifting the same to MES store yard/ workshop, dismantling the same to check and assess the defect and reassembling the same after carrying out necessary repairs/ renewal of copper wire winding/defective parts inmcluding testing in E/M store yard and renewal of PVC insulated flexible twin core twisted copper conductor cable of size 23/.0076 and re-fixing and re-connecting the same complete all as specified and directed. Note: (i) M & L for copper wire winding of fans, overhauling of fans and supply only of parts of fans shall be measured and paid separately under appropriate items. However, cost of PVC insulated flexible cable shall be deemed included in the unit rates of this item. (ii) Labour Rates for 'Supply only items' shall deemed to be included in the quoted rate of this item.
Overhauling of Exhaust fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etc and reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 complete and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate.
Taking down deteriorted louvers and supplying and fix new louvers fixed type made out of 16SWG GI sheet with machine pressed cut for horizontal ventilation, bending into shape of size 45cmx45cm (outer) with 20x3mm flat iron base of size 45cmx45cm complete all as specified and directed by Engr-in-Charge
M & L for rewinding of exhaust fan with super enamelled copper wire of same size/gauge, no of turns as per existing, varnishing, oiling and greasing of any make of size 230/300/380mm sweep by dismantling its parts and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover and cleaning of exhaust fan body and its blade by cleaning agent, assembling, and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate
S & F Exhaust fan blade suitable to any sweep exhaust fan and makes complete all as specified and as directed by Engr-in-charge.
M&L for preparing exhaust fan of any size surfaces for painting by removing/cleaning dust and deposited material and applying one coats of grey enamelled paint by spray to Exhaust fan body, blades and louvers complete all as specified and as directed by Engr-in-Charge
Cutting hole in existing concrete or brick wall suitable for fixing 300mm sweep exhaust fan making good the hole including proper internal plaster work and surface finish in side and outside the hole as per site requirement complete all as specified and directed by Engr-in-Charge
Taking out unserviceable and S&F Exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz,300mm sweep having power input 70W speed 1440RPM, with protective bird guard including connection as required at site with flexible copper cable all as per specified and directed.
Inspection/ checking of serviceability for Ceiling/Exhaust fan to avoid any accident on site a job shall be done including taking down ceiling fan from its position, checking and replacement of minor unserviceable and minor defective spare parts responsible for any accident (i.e. 'S' hooks, split pin, cotter pins, rubber bush etc) and compulsury fixing of new safety wire (SWR) from fan motor to Ceiling hook incl hanging it to its same location after complete assurence of any defect and connecting with copper conductor multi stranded 3 core wire of size 0.75 sqmm complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper/ aluminium point wiring i.e. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
M & L for point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, passing through PVC casing caping including accessories and provision of PVC box for mounting of modular Switchs & Sockets as required at site as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLS earth wire and connected to earth dolly for the following:- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin switch socket combination 5 Amps on the same board with other switches.
One 3 pin switch socket combination 5 Amps, independent.
One bell point controlled by one push button
All as per item No 25.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred.
S & F in replacement with modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred.
S & F modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred.
S & F in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred.
S & F ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm
S & F modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred.
S & F in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred.
S & F modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred.
S & F in replacement with modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred.
S & F modular bell push switch, 1 module, single pole one way 6Amp ISI marked.
S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked.
S & F in replacement with modular electric bell ding dong, AC, 230V single pole.
S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked.
Supply & Fixing Retrofit LED lamp 7 Watts complete all as specified and directed.
Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular PVC Gang box, screwless of 8 module for mounting of modular switches and sockets including blank plate for blank module.
All as per Item No- 37.00 above but of modular PVC Gang box, 6 module.
All as per Item No- 37.00 above but of modular PVC Gang box, 3 module.
All as per Item No- 37.00 above but of modular PVC Gang box, 2 module.
All as per Item No- 37.00 above but of modular PVC Gang box, 1 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 6 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 2 module.
S&F modular white cover plate with frame, 1 module.
Taking down unserviceable FTL/batten fittings with supply and fix LED Aluminium housing of batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of aluminium extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab.
Taking down unserviceable FTL/batten fittings with supply and fix LED integrated polycarbonate housing of batten of 10 Watt 2ft LED give minimum output lumen 1150 lm, efficiency >110, CCT 4000/6500K, CRI >80, power factor >0.9, operating temperature 45 degree celcious, THD <20% of housing polycarbonate extrusion with LED dimension 603mmx22mmx36mm upto 50% energy saving.
Taking out any type of FTL fitting and S&F 10W LED batten with inbuilt smart motion sensor, 230 Volt , 50 Hz , 2 feet, polycarbonate extruted channel, powder coated with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with all accessories including two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose complete with following specification. (i) housing-polycarbonate extrusion,diffuser- opal- polymer, LED type- MID power ,Light distribition- general Spread, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95, THD - <10%, Mounting/Fixing- Wall/Ceiling, Ingress Protection - IP-20, Sensor type- HF inbuilt integral occupancy/movement sensor, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec . in absence of otion switches back to default operation, LED life- upto 30,000 Hrs.Surge Protection- not less than 2KV. Note:- (i) contractor shall submit LM79 report LM 80Test certificates before claiming for payment .(ii) Warranty certificate for minimum 2 years to be submitted from OEM.
S&F MCB DB SPN conforming to IP 43 - IK 09 with acrylic double door, 8 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls.
Taking out Old U/S and S&F MCB SPN, 32 Amp, 10 KA, 230 Volt 'C' curve type.
Taking out Old U/S and S&F MCB, single pole, upto 20 Amp, 10 KA, 230 Volt 'C' curve type.
S & F cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified.
S&F in relplacement with new cable PVC insulated three core over all PVC sheathed 2.5 Sqmm stranded copper conductor cable for connecion from DB to connector junction box for power supply to security light fittings drawn in PVC conduit not less than 20mm including taking out old one all as directed.
S & F junction box of size not less than 4x4 inch with connector encloser, 3 terminal/ PVC/ polycarbonate, isolated body including taking out old one.
S&F street light bracket bend to shape made as required of 40mm dia 1.0 mtr long GI pipe light grade fixed to pole/ Wall including M&L for fixing with the help of flat iron clamp of size 40x6mm two numbers with the help of nuts and bolts for fixing of street light fitting on the wall complete after taking out old U/S one all as specified and as directed.
Taking out Old, U/s one Supply and fixing LED Bldg security light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F Wall fan, made of sturdy Engineering plastic, voltage 230V, 50 Hz, RPM 1350 Copper winding of sweep 400 mm including connection as required at site.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp, 240 volts complete all as specified and directed.
Supply and fixing GI safety wire rope (SWR) with locking arrangement for ceiling fan including all accessories complete all as specified and as directed.
Shree Gajanan Enterprises (BID ID -3469227)
NOEL ENGINEERS (BID ID -3465246)
ASHOK ENTERPRISES (BID ID -3469295)
Angrahit Services Trading Co (BID ID -3469513)
GANGAJAL (BID ID -3467428)
Chakshu Enterprise (BID ID -3474641)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
TENDERDOCUMENTS.pdf
Tender Documents • 1.04 MB
BOQ_823942.xls
BOQ • 1.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .