Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC RADHA NIKUNJ L 2 SOUTH CIVIL LINES ROORKEE HARIDWAR UTTARAKHAND 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.3 L+₹56,712.75 (1.73%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹34.4 L+₹1.6 L (4.89%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹36.0 L+₹3.2 L (9.82%)Rejected-Finance 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹37.0 L+₹4.2 L (12.9%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE CENTRAL BANGALORE
ASC CENTRE AND COLLEGE AGRAM POST BANGALORE 560007
SPECIAL REPAIRS REPLACEMENT PROVN OF CEILING FANS, SPLIT ACS DEEP FREEZER AND GEYSERS UNDER AGE E AND M OF GE CENTRAL BANGALORE
2024_MES_670867_1
8422E
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE CENTRAL BANGALORE
Please refer tender documents
6 documents required · 6 mandatory
₹500
Yes
GE CENTRAL BANGALORE
₹77,000
Yes
16 Nov 2024
3 Sept 2024
30 Sept 2024
3 Sept 2024
28 Sept 2024
16 Sept 2024
3 Sept 2024 - 14 Sept 2024
Amount
Excavation in trenches and not exe. 1.5 m wide and not exe. 1.5 m in depth aying of cables , stay etc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in hard/ dense soil complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft rock complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed .at a level not exceeding 1.5 M above the starting point complete all as directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated ( punned) upto 180mm thickness, complete all as specified and as directed. Note: Punned thickness only will be measured and paid.
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Material and labour for point wiring for one socket outlet 15Amps on independent board with 4 Sqmm (noninal area) single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS, terminated in & including sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete, all as specified & directed.
Supply and fix Switch socket combination flush type 2 in 1 , 3 pin 6 & 16 Amps n universal multipurpose complete all as directed.
S & F MCB single pole 6 to 32 Amps 240 volts, 10 kA rupturing capacity providing in DB complete with all as specified and directed by Engr-in-charge.
S & F MCB single pole & neutral 40 Amps 240 volts, 10 kA rupturing capacity providing in DB complete all as specified.
S&F Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 4 way Horizontal type, single door, doublee pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
Supply and fixing metal plug & socket DB, SP, with a three pin and earth plug with socket, 20 Amps 230 Volts with & including one MCB TP ‘C’ Curve 16 kA 32 Amps all as specified
Supply and fixing ceiling fan 1200 mm sweep min air delivery 210 CFM with service value 6.00 BEE Five Star rated with brushless direct current motor (BLDC) suitable for 230 Volts, 50 Hz, AC supply with down rod , electronic regulator with remote , pair of battries suitable for remote & canopy including provision of fan hook in ceiling for fixing of ceiling fan including necessary electric connection with 1.5 Sqmm, three core, flexible copper multistranded conductor cable as per manufacturers instructions & testing on completion to entire satisfaction of EIC & as directed
All same as per item No 12 here-in-above but 1400 mm sweep fan -do-
Supply & Fixing Electric 100 ltrs apacity water heater 5 Star rating vertical / horizontal type as ordered with Blue Diamond glass lined tank., Temperature Control Knob Easy temperature settings.,Glass-Coated Incoloy Heating Element Resistant to scale formation, Advanced PUF Insulation High energy efficiency and power savings, Long-lasting Anode Rod 2X lifespan , white colour plastic outer body PUF insulation , Power 3000W , Voltage / Frequency (V/Hz): 230V~ / 50Hz , 80 N/cm² rated water pressure , reheating time for 74º C rise/min , single phase 230V , AC Supply along with pair of 40 mm dia heavy duty PVC connections minimum 600 mm long suitable for both inlet & outlet hot water fixed with brass adopter / union washer both sides fixed as per manufacturers instructions & testing on completion complete all as directed. (Note : Quoted rate is deemed to be inclusive of Pair of PVC connections).Note : (i) Geysers shall be fixed as per TI No-4 of 1983 and IS No 2082 1978/1985.(ii) After completion of work contractor shall give a written warranty for 7 Years on Tank,4 Years on Heating Element and 2 Years on Other Parts as per manufactiurers instructions.
M & L for 15 mm bore steel galvanised iron water tubing medium grade (ISI marked) with fittings all new (ISI marked) fixed to wall and ceiling or laid in floors complete all as directed.
S&F 15 mm bore stop valve,cast copper alloy fancy type ,screwed down high pressure with crunth or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified.
S&F 15 mm bore fancy type bib taps, cast copper alloy with cruth or butterfly handle, screwed down,screwed for iron pipe or for brass ferrule and fixed. Complete all as specified.
M&L for cutting to existing pipe line 20/25 mm bore for insertion of tee of size as ordered and GI union 25/20 mm bore complete including required threading to existing pipe for taking out New connection for geyser inlet complete all as required and directed .
Supply & fixing Voltage Stabilizer of capacity 2 KVA for automatic operation, Single Phase, naturally air cooled, indoor type, designed for input variation between 170 Volt to 250 Volt and with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and connecting up all as per manufacturer’s instructions & as directed. Make :- Brentford / Vinus / AE / Vinitec / V-Guard / Power Tech / ITE, Gurgoan / Volina / Blue Line
Supply, installation, commissioning of Glass Top Deep Freezer, 320 ltrs Five star rated electric driven, single phase, 240 volt, 50 Hz , AC, all as specified & as directed. Make : Whirl Pool / Godrej / LG / Voltas / Samsung / Hitachi / Blue Star
S&F Sheet metal enclosure (ISI marked) distribution board for 240 volts, SP&N 4 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
S & F MCB single pole & neutral 32 Amps 240 volts, 10 kA rupturing capacity providing in DB complete all as specified.
S & F MCB single pole 16 to 32 Amps 240 volts, 10 kA rupturing capacity providing in DB complete all as specified and directed by Engr-in-charge.
M&L for sub main wiring and provide new submain wiring with 2 runs of 6 Sqmm , FRLSsingle core PVC insulated, unsheathed, multi stranded copper conductor and one single core 6 Sqmm PVC insulated , unsheathed , multi stranded copper cable as earthing lead as per IS : 694 / 1990 drawn through and including non-metallic PVC rigid conduit/casing caping of size as ordered in walls / ceilings / Concealed etc with all accessories such as Tees, Elbows, junction box, reducers etc and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note :- 2 runs 6 Sqmm cable , one run 6 Sqmm cable and one run of PVC Conduit /Casing caping shall be measured as one unit length) .
All as per item No 24 here-in-above but 2 runs with 4 Sqmm single core cable and 4 Sqmm single core as earth contunity wire -do- . (Note :- 2 runs 4 Sqmm cable , one run 4 Sqmm cable and one run of PVC Conduit/Casing caping shall be measured as one unit length)
Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 4 core 10sq mm XLPE insulated , armoured, electric power cables (heavy duty) with standard aluminium conductor including testing on completion coplete all as directed. Note: The rate quoted inclusive of termination at ends with suitable aluminium lugs wherever required. Make: Paragon/Havells/Polycab/ Nicco
Supply & fixing Air cooled split unit air conditioner electric driven single phase of capacity 1.5 TR (5 Star rating) heating & cooling type including outer & inner assembly with all accessories & cordless remote control unit and connecting up with and including single phase naturally air cooled indoor type designed for input variation between 170 V to 250 V with output voltage stablized at 230 V with accuracy + 2.5% Voltage Stabilizer 4 KVA capacity complete all as per manufacturer’s instructions & as directed. Note : (i) Make of AC : Carrier / LG / Voltas / Hitachi / Daikan / Samsung / Blue Star / Feeders Lloyd / Godrej (ii) Make of Voltage Stabilizer :- Brentford / Vinus / AE / Vinitec / V-Guard / Power Tech / ITE, Gurgoan / Volina / Blue Line (iii) The quoted rate is deemed to be inclusive of cutting chases/cutting holes etc in any type of masonry walls/floors including making good in cement mortar 1:4 & finishing the distured surface of walls / floor to its original secifications and other necessary arrangement for fixing indoor & outdoor unit & other minor extras as applicable at site to make the unit complete functional .
GS TRADERS (BID ID -3102921)
Gee Kay Projects (BID ID -3103969)
K. VENKATESH NAIDU (BID ID -3104168)
SREE BALAJI CONSTRUCTIONS (BID ID -3103938)
M/S Jaiprakash Electrical and Engineering Works (BID ID -3100611)
kamadhenu Electricals (BID ID -3103263)
Chandana Enterprises (BID ID -3101073)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .