| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC AOC | |
| 2 | L2₹5.7 L+₹22,909.50 (4.20%)Rejected-AOC | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹5.7 L+₹29,562.20 (5.42%)Rejected-AOC | L3 | Rejected-AOC Other than lowest | |
| 4 | L4₹7.1 L+₹1.7 L (30.8%)Rejected-AOC | L4 | Rejected-AOC Other than lowest | |
| 5 | L5₹7.3 L+₹1.8 L (33.7%)Rejected-AOC | L5 | Rejected-AOC Other than lowest |
Tender Value
Refer Docs
EMD Value
₹16,200
Closing Date
5 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I)CIF(U)
AGE(I)CIF(U)
PROVN OF ELECTRICAL CONNECTIONS FOR INSTALLATION OF 30 KVA GEN SET AND SPECIAL REPAIR TO LIGHT CABLE, PANELS, EARTHINGS AND SWITCH GEARS AT SILA GRN UNDER AGE (I) CIF(U)
2020_MES_401440_1
AGE(I)CIF(U)-28 /2020-21
Open Tender
Civil Works
Item Rate
180 days
AOR of AGE(I)CIF(U)
As per NIT
9 documents required · 9 mandatory
₹500
AGE(I)CIF(U)
₹16,200
Yes
9 Mar 2021
7 Dec 2020
7 Jan 2021
7 Dec 2020
5 Jan 2021
23 Dec 2020
60 days
Amount
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for laying of cable or pipes, trimming the sides, forming bottom surfaces to required leve, n.exc 10sqm on plan and getting out, complete, all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete, all as specified and directed.
Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed.
M&L for dry sand cushioning to under ground cable 8cm thick before laying the cable and 15cm thick after laying the streching the cable in trenches, including hand punning and consolidating complete all as specified. Note : for payment purpose punned thickness shall be measured.
M&L for sub class ‘B brick, old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete, all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed .
M&L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed .
M&L for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed .
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 185 sqmm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 120 sqmm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 95 sqmm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 70 sqmm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 50 sqmm 3.5 core, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 25 sqmm 4 core, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 16 sqmm 4 core, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 10 sqmm 2 core, complete all as specified and directed.
Supplying and fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium solid conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections of size 10 sqmm 2 core including taking down old unserviceable cable, complete all as specified and directed.
Design, supply, installation, testing and commissioning of Cubical type floor mounted LT panel, size 1.5 x 1.2x 0.60 M depth, outdoor type factory fabricated made out of CRCA sheet of 3.15mm thick, fully enclosed and angle iron frame of six 40 x 40 x 6mm thick and T section with front openable double door shutter, dust and vermin proof and rear opening complete with locking arrangement, having a system of bus bars of aluminium of suitable size of 400 AMPS duly inslulated and mounted on Epoxy/porcelain insulators in totallly enclosed chamber with three phase and neutral 415 volts, AC system prewired with suitable copper wire PVC insulated with all control accesories, provn of suitable cable glands, duly powder coated of approved quality over a coat of red primer with sufficient free space complete to include the following accessories: - (a) MCCB 200 AMPS capacity 4 pole, 38 KA, 415 V fixed Thermal & Fixed Magnetic setting type as incoming -01 No. (b) MCCB 200 AMPS capacity 4 pole, 38 KA, 415 V fixed Thermal & Fixed Magnetic setting type as incoming - 01 No. (c) MCCB 100 AMPS capacity 4 pole, 25 KA, 415 V fixed Thermal & Fixed Magnetic setting type as incoming - 01 No. (d) Digital multi function meter (e) Set of indicating lamp with toggle switch RYB-01 Set.
M&L Earthing for machinery / equipment installted at power house / substation using GI strip of earth lead and MS galvanized steel earth plate electrode 600 x 600 x 6.3mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32 x 6mm with GI pipe, nuts, bolts and washers complete and including test point terminal block made of gun metal or phosphours bronze size 75x75x25 mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw and PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt around the earth plate watering pipe 20mm light grade/galvanized and 40mm dia GI pipe med grade for protection of GI strip with funnel and wire mesh for watering including necessary excavation and earth works in any type of soil complete all as specified and directed as shown in Electrical Plate No. 3 of SSR (Part-I) of 2009 and testing on completion. incl taking down of old U/S all as specified. (Note: Earth result should not exceed 2 Ohms)
S&F MCCB four pole 160 Amps, 38 KA fixed thermal & fixed magnetic setting including 4 spreader link set of same make as that of MCCB for connection, rincluding required lugs. complete all as specified and directed. Make - Havells Cat Part No IHD2HTBF0160 or equivalent in Legrand/ C&S/Schneider/Hager as approved.
S&F MCCB four pole 200 Amps, 38 KA fixed thermal & fixed magnetic setting including 4 spreder link set of same make as that of MCCB for connection, and lugs as required. Make Havells Cat Part No. IHD2HTBF0200 or equivalent in Legrand/ C&S/Schneider/Hager as approved.
S&F MCCB four pole 125 Amps, 38 KA fixed thermal & fixed magnetic setting including 4 spreder link set of same make as that of MCCB for connection and lugs as required. Make Havells Cat Part NO. IHDA6OBF0125 or equivalent in Legrand/ C&S/Schneider/Hager as approved.
S&F MCCB for pole 63 Amps, 25 KA fixed thermal & fixed magnetic setting including 4 spreder link set of same make as that of MCCB for connection and lugs as required. Make Havells Cat Part NO. IHDA6OBF0063 or equivalent in Legrand/ C&S/Schneider/Hager as approved.
S&F on load change over switch with steel sheet enclosure of capacity 100 Amp 4 pole, front lever operated on wall / surface with necessary fastener nuts complete all as specified, Make - Havells, Cat part No - IHCNF00100 or equivalent in Legrand/ L&T/Schneider/Hager as approved.
S&F on load change over switch with steel sheet enclosure of capacity 200 Amp 4 pole with advance neutral, front lever operated on wall / surface with necessary fastner nuts complete all as specified, Make - Havells, Cat part No - IHCNF00200 or equivalent in Legrand/ L&T/Schneider/Hager as approved.
M & L aluminium conductor, steel reinforced for LT poles including bending, strecching and jointing with aluminium binding wore of size 1 of 6/2 x 2.59 mm (squirral) including taking down old UNSV aluminium conductor, complete all as specified and directed by Engineer-in-Charge.
M&L for cross arms, bracing supports, clamps and back plates fabricated from structural steel sections confirming to grade FE 410-S including nuts, bolts, washer, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and one primer coate and two coats of aluminium paint incl taking down of old unserviceable, complete all as specified and directed.
M&L for Pin type insluator vitreous porcelain, white or bown or green, including one galvanised iron washers and one galvanised iron nut, size 100mm height, 65mm dia for 1100V grade including taking down of old unserviceable, complete all as specified and directed.
M&L for Shackle type insulator porcelain vitreous whilte, brown or green 75mm high and 90mm dia for conductor fo working pressure 1100 volts including galvanised mild steel straps of 31x3mm size, 12mm dia insulator bolts, washers and nuts, complete all as specified including taking down old unserviceable insulators of any type, shape and size, all as specified.
M&L steel tubular swaged pole 09 metre long complete with cast iron base plate finial taper plug, bolts, nuts and secrew all as specified type 410 SP-31 (9.0 metres long) including painting upto 1.5M above PCC coping in black and white strips 5 Nos each 30 CM high starting from botting of pole. The pole shall be coated with two coats of black bituminous paint throughout internally and externally up to the planting depth. The remaining portion of the exterior shall be painted with on coat of red oxidor primer including dismantling of old damaged LT poles of any type and size for taking credit complete all as specified and as directed by Engr-in-Charge.
Supply, Laying, fixing GI Wire 3.15/ 4mm dia stretching without kinks and bends for earth wire, guarding etc inluding binding material / wires including taking down old UNSV aluminium conductor, complete all as specified and directed by Enginer-in-Charge
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized wire 4 mm dia by means of bolts, nuts and washers of galvanized iorn or steel all as shown in electrical plate No. 3 connected to earth test point incl necessary earth work excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber provn of RCC cover 40 mm thick in 1:2:4 mix type B1 funnel with wter pipe GI pipe 15mm dia medium grade as protection pipe GI earth lead including taking down of old unserviceable, complete all as specified and directed.
Cutting of road not exceeding 100 CM depth for laying of UG Cable incl make good the surface of road with cement plaster mix 1:2 of suitable quantity, complete all as specified and directed.
S & F of tubes light grade of 80 mm bore galvanised with all fitting for cable protection trenches / wall / on pole including necessary clamps sets and nut & bolts complete all as specified and directed by Engineer-in-Charge.
Timer switch with sheet metal enclosure pole mounted type fabricated out of 16 gauge steel sheet consisting of following : - (i) Digital type time swith 24 hours with Power contactor single phase of 32 /TP Amp and MCB of 40 Amp SPN (CAT Part No. IHXSS01060 of Havells " or equivalent in makes in LEGRAND/ L&T)
Timer switch with sheet metal enclosure pole mounted type fabricated out of 16 gauge steel sheet consisting of following : - (i) Digital type time swith 24 hours with Power contactor single phase of 65 /TP Amp and MCB of 63 Amp SPN (CAT Part No. IHXSS03120 of Havells " or equivalent in makes in LEGRAND/ L&T)
Material and labour for Outdoor type factory made Bus bar chamber of size 0.45 x 75 x 0.40 M depth made out of CRCA sheet 3.15 mm thick, suitable for 63 AMP Changeover switch 4 pole, 415 volt, 25 KA having locking arrangement, provn of suitable hole at bottom for incoming and outgoing UG cables incl painting with 2 coat of powder coated paint over a coat of red oxide promer on exterior and interior faces of Bus bar chamber, errection of Bus bar chamber with PCC 1:2:4 type B2 and fixing and connection of changeover switch including earth work and provn of suitable frame at bottom made out of angle iron of size 40 x40 x6mm thick complete all as specified and directed by Engineer-in-Charge.
S&F on load change over switch in open execution of capacity 63 AMP, 4 pole, 415 volts with front lever operated complete all as specified and direced by Engineer -in - Charge. Make - Havells Cat Part No. IHCNFO0063 or equivalent in Shneider/L&T/Legrand.
Jiwan Singh
M/S MANJIT SINGH AND SONS
M/S INDERPAL SINGH
BINDRA ENGINEERS AND CO
M/s Lakhanpal Trading Co.
SHANTI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .