| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹23.3 L+₹82,073.80 (3.66%)Rejected-Finance | L2 | Rejected-Finance Not being Lowest | |
| 3 | L3₹24.5 L+₹2.0 L (8.99%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L3 | Rejected-Finance Not being Lowest | |
| 4 | L4₹25.5 L+₹3.1 L (13.8%)Rejected-Finance | L4 | Rejected-Finance Not being Lowest | |
| 5 | L5₹25.8 L+₹3.3 L (14.8%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L5 | Rejected-Finance Not being Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER I Rnd D WEST BANGALORE
GARRISON ENGINEER I RndD WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
REPAIR REPLACEMENT OF SECURITY LIGHT PERIMETER LIGHTS AND ALLIED WORKS AT CAIR DAD DCA AND SERVICE CENTRE N0 3 AREA OF GE I R AND D WEST BENGALURU
2025_MES_710304_1
GE(I)/R ND D (WEST)/BAN/TOKEN/10 OF 2025-26 8374/E8
Open Tender
Civil Works
Item Rate
270 days
Work
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER I Rnd D WEST BANGALORE
₹80,000
16 Jul 2025
28 May 2025
25 Jun 2025
29 May 2025
19 Jun 2025
13 Jun 2025
29 May 2025 - 12 Jun 2025
Amount
Supply and fix in replacement LED street light fitting 35/36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
Supply and fix in Replacement of LED Street/ security light fittings with lamp,45W,lens & toughened glass IP 66, with high lumen output, environmental friendly, energy efficient LED, street light fitting with lamps and accessories including GI piping Bracket suitable bend for holding street/ security light, system electrical efficiency > 85%, system efficacy > 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, complete all as specified and directed.
Supply and fix in replacement LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with complete all as specified and directed
Supply and fix in replacement LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with complete all as specified and directed
Supply and fix in replacement LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fix in repalcement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fix in replacement LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fix in replacement post top lantern LED type 40 watt conical in shape 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65/66 protection with impact and corrosion resistant complete with driver and lamp complete all as specied and directed.
Supply and fix in replacement / installation of cable junction box made of high quality DK thermoplastic of size 300X200X125 mm including four number connection terminals suitable mouted on DN rail for alumn cables upto 25 sqmm 4 core with one single pole MCB 'C' curve type of current rating 6 amps and rupturing cap 10 KA complete with thermoplastic cable glands and fixed on GI Pipe and using pole clamps made out of appropriate material all as required at site or directed including inspection/ site testing (after installation at site) by company engineer. (Note: GI pipe measured separatally) Make: HENSEL /Sintex/ MECO or eqvivalent.
Supply and fixing in replacement / installation of erection of steel tubular swaged pole 9mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative green & white strips of 30 cm height upto 1.5 mtr above ground level all as required at site or directed by Engr-in-charge.
M & L for Painting to steel tubular pole swarn neck type/9/11 mtr long including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, street light bracket complete including painting with five strips of 30cm each black/yellow and silver paint(as per existing paint) in alternate strips from the base of pole upto 1.5mtr height complete, marking the pole No, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed.
Supply, fixing in replacement, connecting and testing of MCCBs in existing LT panel box / feeder pillar boxes (KIOSK) of capacity 400 Amps 4 pole breaking capacity 36 KA with thermal as well as magnetic balance adjustable type complete all as specified and directed.
Ditto- all as per Item No 13 but 350 Amps and 36 KA.
Ditto- all as per Item No 13 but 250 Amps and 36 KA.
Ditto- all as per Item No 13 but 200 Amps and 36 KA.
Ditto- all as per Item No 13 but 160 Amps and 36 KA.
Excavation in trenches in hard/dense soil not exc 1.5 metre wide not exc 1.5 metre in depth; for laying of cables not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out , trimming sides, forming bottom surface to required level complete all as specified and as directed .
Excavation in trenches not exceeding 1.5 m wide and not exceeding 3.0 mtr in depth for foundation in hard/dense soil and getting out all as directed.
Returning filling including spreading, levelling , watering and well ramming in layers n.exc 25cm in soil as directed .
Removing of excavated soil to a distance not exc 50 m & depositing where as directed at a level n.exc 1.5m above starting point all as specified and as directed.
Screening excavated earth (passing through 12 mm square mesh), laying riddled earth in trenches for cable protection, under and above Cable all as specified in SSR Part - I (Clause No 19.75) and as directed by Engineer-in-Charge. Note : Punned thickness of riddled earth of 18 cm will be measured and paid.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Material and Labour for PCC 1:3:6 type C1 using 20mm graded stone aggregate for coping of poles/plinth blocks of HT poles etc including fair finishing the exposed surfaces even and smooth without using extra cement including necessary form work complete all as specified and as directed.
Material and Labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified.
Taking down existing 1100 Volts grade cable size up to 35 sqmm 3.5 core from in trench, wall, ceiling, culvert and pole and laying only XLPE insulated, tesing complete all as specified and directed.
Supply and fix in replacement cable of XLPE insulated armoured LT cable 1100 volts grade of size 6 Sqmm 2 core, in tenches / on walls /poles including suitable MS clamps for fixing, connecting , testing and commissioning for building service connections including taking down the exisitng unserviceable cable complete all as specified and as directed. NOTES :- Earthwork, sand filling, brick protection shall be measured and paid separately under relevant items of this schedule.
All as per item 27 here in before but cable size 10 sqmm 4 core
All as per item 27 here in before but cable size 16 sqmm 4 core
Supply and fix in replacement of light grade Galvanised mild steel pipe 32mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable proction . (Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule )
Material and Labour for aluminium lugs up to 185sqmm as per site requirement complete all specified and directed.
M & L for Earthing in replacement complete with galvanized steel earth plate electrode 60cmX60cmX6 mm thick buried in ground vertically to a depth not less than 2.25 metre below normal ground level, normal with top edge of earth plate not less than 1.5 metre below normal ground level, earth plate connected to a galvanised earth lead wire 4mm dia bymeans of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I (2009) connected to earth test point all as specified or indicated including testing on completion with and including 15 mm bore light grade GI protection pipe 7.5 meters long for earth including PCC 1:2:4 pit with pre cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hook made out of 6mm dia MS bars watering arrange,ent with funnel wire, common salt and charcoal filling, necessary excavation and earth work in any type of soil complete all as specified.
S & F in replacement Street light bracket made out of 40 mm dia light grade GI Pipe not less than 1.5m length, bent to shape including 2 Nos, 50 x 6 mm FI Clamps nut,bolts washer etc complete including necessary painting work all as specified and directed.
Supply and laying in replacement GI tubing light grade 50 mm bore for cable protection fixed on wall/pole/laid in trenches complete all as specified and as directed
Supply and fix in replacement LED flood light fitting 210 Watts(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) with ingress protection IP 66 and external SPD of capacity 10 KV in addition to inbuilt SPD of electronic driver , having Pressure die cast housing with high efficient output emitter LED for better distribution, protection with heat resistant toughned glass with individual LED lenses complete including MS Clamps of suitable size for fixing on High Mast /Pole complete all as specified and as directed.
M&L for maintain high mast lights, lower the ring assembly and replace lamps, fuses, fuse holders, photocells, ballasts and other work required to keep the lights operational, clean the glass cover(both inside and outside) and the reflector with an approved cleaning solution, maintain, repair or replace the circuit breaker at the base of the pole add oil to the winch and adjust the winch brake, make a visual inspection of the foundation, poles, anchor bolts, base plate, access door, winch, wire rope including cable attachment plate and cotter pins, electrical power cable and fixture mounting ring. Repair, maintenace and servicing the existing motor and keep it in working condition. repair and repalcement of ring assembly, electrical service, photo electric control, breakers, fuses, contactor, hand auto switch, alluminium rope complete all as specified and directed by Engr-in-charge.
M & L in replacement for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron strip 32 x 6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth strip protected by 40 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge. NOTE :- GI earth strip and protection pipe beyond 7.5 mtr will be measured and paid separately. (Note : 1. If the desired earth resistance is not found earthing shall be re-done by the Contractor at no extra cost paid by Dept.)
Fabricate,Supply,Install,Testing and commissioning of self supporting totally enclosed outdoor type LT Panel 3 phase 4 wire 415 Volts from any CPRI Certified validated Panel Manufactures made out of 3 mm thick CRCA sheet mounted on suitable size MS Base Channel Stand Frame of size ISMC 100 mm thickness not less than 5 mm , Height of Channel stand frame not less than 300 mm from the finished floor, powder coated dust and vermin proof, hinged smoothly openable front and rear, with neoprene rubber gasket including danger plate, earthing strip 32 x 6 mm - 02 Nos along with connecting provosions on body out side - 02 Nos, ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc panel board depth not less than 500 mm in and including of the following switch gear, items complete and connections of all outgoing cables using new suitable rating lugs, danger sign board, lettering and marking complete all as specified and directed. (i)Aluminium Bus Bar of 400 Amp rating supported in suitable size porcelain strand lock with suitable size brass nut, bolt and washers with heat shrinkable colour coded PVC sleaving for three phase and neutral -01 Set
KAALIKA ELEVATORS (BID ID -3323792)
RRK PROJECTS (BID ID -3329468)
Pacific Enterprises (BID ID -3326134)
GS TRADERS (BID ID -3325738)
Solar Electricals and Electronics (BID ID -3329611)
ADR ENTERPRISES (BID ID -3329440)
MAJ CONSTRUCTIONS (BID ID -3329609)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .