Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | Admitted-Finance |
| 2 | Admitted-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
25 Nov 2024, 6:00 pmClosed
GE NAVY LAKSHADWEEP
GE NAVY LAKSHADWEEP KAVARATTI
REPAIR REPLACEMENT TO INTERNAL WIRING FITTINGS AND FIXTURES REWINDING OF CEILING EXHAUST FANS GEYSERS COOLING APPLIANCES LT PANELS LT UG CABLES EARTHING REPAIR MAINT TO DG SETS LIGHTNING PROTECTION STREET LIGHTS INCLUDING BOLLARD LIGHTS AND EXTERNAL
2024_MES_680812_1
8401
Open Tender
Civil Works
Item Rate
300 days
LAKSHADWEEP
AS PER NIT AND TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE NAVY LAKSHADWEEP
₹79,000
Yes
29 Nov 2024
23 Oct 2024
27 Nov 2024
23 Oct 2024
25 Nov 2024
6 Nov 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed .
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets ,ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc., complete all as specified and as directed .
Point wiring with PVC insulated unsheathed and multistranded copper conductor cable ISI marked, 1100 volt grade. FRLS of size 1.5 Sqmm drawn in and including concealed PVC rigid conduite of size not less than 20mm dia with modular metal flush box concealed and modular white plates with frame of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm as earth wire connected common earth dolly as specified for one light point controlled by one switch for light/Fan complete all as specified and as directed . Note : Rate quoted included for cost of (i) Modular metal flux box concealed and making good walls (ii) Modular white cover plate with frame. (iii) Necessary blank plate as required at site.
All as per item No 03 here in before but one 3 pin 5 amps switch sockets on same board
All as per item No 03 here in before but one 3 pin 5 amps switch sockets on independent board
All as per item No 03 here in before but with cable size 2.5 Sqmm and 2.5 Sqmm as earthwire for 3/5 pin socket out let independent, 15/16 Amps
S & F modular switch, 1 way, 6A, 1 module complete all as specified and as directed.
S&F modular socket, 6A, -2/3 pin combined 2 module complete all as specified and as directed.
S & F modular switch, 1 way, 16A, 1 module complete all as specified and as directed.
S&F modular socket, 6/16A, - 2/3 pin combined 2 module complete all as specified and as directed.
S & F switch piano flush type single pole one way 5 amps 230 volts (ISI Marked) complete all as specified and as directed.
S&F switch socket combination flush type universal 2 in 1, 3 pin 5 Amps 230 volts (ISI Marked) complete all as specified and as directed.
All as per Item No 12.00 here in before but of capacity 15 Amps.
S & F in replacement of ceiling rose 3 terminal 5 Amps 230 volts (ISI marked) PVC/Polycarbonate, insulated body complete all as specified and as directed.
S & F in replacement of Fan step Regulator, 120 Watt, 2 module, hum free complete all as specified and as directed .
Submain wiring with Two runs of 2.5 sqmm size multi stranded copper conductor PVC insulated unsheathed cable (FRLS) in and including PVC rigid non metalic conduit and one run of PVC insulated cable of size 2.5 sqmm size multi stranded copper conductor PVC insulated and unsheathed for contineous earth wire including taking down old wiring complete all as specified and as directed .
Submain wiring with Two runs of 4.0 sqmm size multi stranded copper conductor PVC insulated unsheathed cable (FRLS) in and including PVC rigid non metalic conduit and one run of PVC insulated cable of size 4.0 sqmm size multi stranded copper conductor PVC insulated and unsheathed for contineous earth wire including taking down old wiring complete all as specified and as directed .
S & F in replacement of switch piano flush type single pole one way 5 amps 230 volts (ISI Marked) complete all as specified and as directed.
S & F in replacement of switch socket combination flush type 2 in 1, 3 pin 5 Amps 230 volts (ISI Marked) complete all as specified and as directed.
S & F in replacement of switch socket combination flush type 2 in 1, 5 pin 5 / 15 Amps 230 volts (ISI Marked) complete all as specified and as directed.
S & F in replacement of lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed .
M&L PVC rectangular block for mounting switches, sockets, fan regulator etc., with 3mm thick plastic laminated sheet cover of size 100 mmX 100 mm and 50mm deep complete all as specified and as directed .
All as per item No. 22 here in before but of size 175 x 100 x 50 mm
All as per item No. 22 here in before but of size 200 x 150 x 50 mm
S&F in replacement of modular Bell push, 5 A, 1 module complete all as specified and as directed
S & F in replacement of bell electric ding dong AC 230 V single pole complete all as specified and as directed.
S & F in replacement of switch bell push button type 5 Amp single pole complete all as specified and directed
S & F in replacement of surface and wall mounted LED batten 2 feet long 9/10W extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver including all connections complete all as specified and as directed.
S & F in replacement of surface and wall mounted LED batten 4 feet long 18 / 20W extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver including all connections complete all as specified and as directed.
S & F in replacement of LED new adore 10W CDL ball lamp suitable to hold in B22 base camp with system lumen output 850 complete all as specified and as directed
S & F in replacement of LED ceiling light recessed mounted type 42 W fixture size 2 ft x 2 ft fitting complete with all accessories including driver and internally pre-wired with electrical connections complete all as specified and as directed.
S & F in replacement of LED ceiling light recessed mounted round type 12W complete with all accessories including driver and internally pre-wired with electrical connections complete all as specified and as directed .
S & F in replacement of LED ceiling light recessed mounted square type 12W complete with all accessories including driver and internally pre-wired with electrical connections complete all as specified and as directed .
S & F in replacement of street light brackets made out of 40mm bore GI tubing, light grade, 1.5m long, bent to required shape, including necessary bending, welding, etc fixed with 2Nos. clamps made out of 32x5mm GI strip including necessary drilling holes, screws, nuts, bolts, etc complete all as specified and as directed .
S & F in replacement of building security lights surface mounted LED fitting 45 Watt with extruded aluminium heat sink housing and IP 66 protection complete with all accessories and internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed .
S & F in replacement of energy efficient LED building security light lumiaires with pressure die cast alluminium IP 66 ,having LED light 25W complete with all accessories and internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed .
S & F in replacement of sheet metal enclosure with two pin socket , chain plug cover with MCB SPN of 10 Amp capacity with alignment 10 KA ‘B’ series complete all as specified and as directed.
S & F in replacement of MCB SP 6 to 32 Amp, 240 V, B Series, complete all as specified and as directed .
S&F in replacement of MCB SPN 32 Amp 240 V , 50 Hz, complete all as specified and as directed.
S&F in replacement of MCB SPN 40 to 63 Amp 240 V , 50 Hz, complete all as specified and directed.
S & F in replacement of MCB TP 25 to 63 Amp, 415 V, 50 Hz , C Series, complete all as specified and as directed .
S & F in replacement of MCB TPN 40 to 100 Amp, 415 V, 50 Hz , C Series, complete all as specified and as directed.
S&F in replacement of MCB DB TPN 4 Way 415 V , 50 Hz, with 200A rated copper busbar complete all as specified and directed.
S&F in replacement of MCB DB SPN 4 Way 240 V , 50 Hz, with 200A rated copper busbar complete all as specified and directed.
S&F in replacement of MCB DB SPN 8 Way 240 V , 50 Hz, with 200A rated copper busbar complete all as specified and directed.
S&F in replacement of MCB DB SPN 12 Way 240 V , 50 Hz, with 200A rated copper busbar complete all as specified and directed.
Taking down existing unserviciable ceiling fan /exhaust fan of any type and rewinding the same with fine enamelled copper conductor and refixing at same location and testing complete all as specified and as directed .
S & F in replacement of condenser of 2.5 MFD complete all as specified and as directed .
S & F in replacement of ball bering of suitable existing size for ceiling fan 1200mm sweep complete all as specified and as directed .
S & F in replacement of ball bering of suitable existing size for exhaust fan 300 mm sweep complete all as specified and as directed .
Taking down the unserviceable Electric geyser 25 Ltrs capacity and transporting to work shop for repairs/replacement of unserverviceable items such as heating coil, thermostat, copper container, indicating lamp to match the existing geyser complete all as specified and as directed . Note : Cost for replacement of items will be measured and paid under respective items as Supply only
Supply only heating coil suitable for Electric geyser 25 Ltrs capacity
Supply only thermostat suitable for Electric geyser 25 Ltrs capacity
Supply only inner container made of copper suitable for Electric geyser 25 Ltrs capacity
S & F in replacement of Exhaust fan PVC body 200mm sweep 240 V AC single phase including connections complete all as specified and as directed .
Maintenance and servicing of split type 1.5/2 Ton AC including cleaning filter, washing with soap solution after removing from site and refixing the same complete all as specified and as directed .
S & F in replacement of hermitically sealed outdoor compressor unit including brazing/welding and leakage testing after completon of job for 1.5 Ton Split type AC complete all as specified and as directed .
All as per item No. 57.00 here in above but for 2.0 Ton capacity
M & L for gas charging including comissioning and testing in split AC 1.5/2 Ton complete all as specified and as directed .
S & F in replacement of condensing coil copper including soldering with existing system for 1.5 Ton AC complete all as specified and as directed .
All as per item No. 60.00 here in above but for 2.0 Ton capacity
S & F in replacement of copper wound condenser fan motor with blade for 1.5 ton AC complete all as specified and as directed .
S & F in replacement of copper wound condenser fan motor with blade for 2.0 ton AC complete all as specified and as directed .
S & F in replacement of outdoor unit Capacitor of capacity 40 ± 5 MFD complete all as specified and as directed .
S & F in replacement of outdoor unit Capacitor of capacity 60 ± 5 MFD complete all as specified and as directed .
S & F in replacement of outdoor unit Capacitor of capacity 2.5 ± 5 MFD complete all as specified and as directed .
Disconnection and removing the unserviceable PCB from the indoor unit of invertor type Split type Air conditioner and S & F new PCB suitable for the existing makes of Air conditioners of capacity 2 TR complete all as specified and as directed .
Disconnection and removing the unserviceable indoor fan motor from the indoor unit of 1.5 TR Split type Air conditioner and S & F New indoor fan motor unit suitable for the existing makes of Air conditioners complete all as specified and as directed .
Disconnection and removing the unserviceable indoor fan blower unit from the indoor unit of 1.5 TR Split type Air conditioner and S & F New indoor fan blower unit suitable for the existing Air conditioners at site complete all as specified and as directed .
Disconnection and removing the unserviceable indoor fan blower unit from the indoor unit of 2.0 TR Split type Air conditioner and S & F New indoor fan blower unit suitable for the existing Air conditioners at site complete all as specified and as directed .
S & F in replacement of copper pipe of size 1/2" dia with necessary fixing arrangements for such as welding, brazing, nut, bolts and testing complete all as specified and as directed .
S & F in replacement of copper pipe of size 1/4" dia with necessary fixing arrangements for such as welding, brazing, nut, bolts and testing complete all as specified and as directed .
S & F in replacement of suitable stand (bracket) for outdoor unit of 1.5/2 ton split air conditioner complete all as specified and as directed .
S & F in replacement of indoor unit display unit with AC remote suitable for 1.5/2 ton split air conditioner complete all as specified and as directed .
S & F in replacement of gas regulating brass valve of compatible with suitable for 1.5/2 ton split air conditioner complete all as specified and as directed .
S & F in replacement of indoor unit flap rotating/ swing motor suitable for 1.5/2 ton split air conditioner including making connections and testing complete all as specified and as directed .
M & L for gas charging including comissioning and testing of 40/80 ltrs capacity water cooler complete all as specified and as directed .
S & F in replacement of compressor unit for 40/80 ltrs capacity water cooler including comissioning and testing complete all as specified and as directed .
S & F in replacement of thermostat for water cooler of existing capacity and make complete all as specified and as directed .
S & F in replacement of capacitor of 10 MFD for water cooler complete all as specified and as directed .
Disconnection and removing the unserviceable voltage stabilizer and replace the unserviceable items such as Transformer / PCB/control board etc and refixing back in its original position testing as per existing makes of capacity 4/5 KVA complete all as specified and as directed
Supply only PCB/control board suitable for 4.0 / 5.0 KVA Votlage stabilizer
Supply only control transformer suitable for 4.0 KVA Votlage stabilizer
Supply only control transformer suitable for 5.0 KVA Votlage stabilizer
Taking down old unserviceable LT UG cable from existing position and supply & laying, connecting and commissioning of LT UG cable 10 sqmm 4 core 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc. laid in trenches or fixed on walls complete all as specified and as directed .
All as per Sl item No. 85.00 here in before but 25 sqmm 4 core
All as per Sl item No. 85.00 here in before but 16 sqmm 4 core
All as per Sl item No. 85.00 here in before but 50 sqmm 3.5 core
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft/loose soil for laying cables/pipes etc. complete all as specified and as directed .
Returning filling in, with excavated soils including spreading, levelling, watering and well ramming in layers n.exc. 25 cms thick. complete all as specified and as directed .
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed .
M&L for sand cushioning with sand in two layer,first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts for cable including consolidation of each layer complete all as specified and as directed . Note: Punned thickness of sand cusioning shall be measured only for the purpose of payment .
Supply and laying in trenches old size common burnt clay brick sub class 'B' for cable protection complete all as specified and as directed.
Cutting the existing hardstanding including taking out PCC interlocking tiles not less than 25cm in deep and 45cm in width for laying of underground cable / pipe and making good the disturbed surfaces including relaying of interlocking tiles complete all as specified and as directed.
S & F in replacement of GI tubing 50 mm dia light grade laid in trenches complete with all accessories such as tees union , bend ,elbow nipple reducer etc as required for protection of UG Cable on floor,pole etc complete all as specified and as directed .
S & F in replacement of MCCB 63 Amps ,16 KA, 4 Pole, 415 V 50 Hz including all connections complete all as specified and as directed .
S & F in replacement of MCCB 100 Amps ,25 KA, 4 Pole, 415 V 50 Hz including all connections complete all as specified and as directed .
S & F in replacement of MCCB 160 Amps , 36 KA, 4 Pole, 415 V 50 Hz including all connections complete all as specified and as directed .
Painting of existing LT panels by using two coats of synthetic enamell paint including prepartions of old surfaces complete all as specified and as directed.
Repairs to existing LT panels front and rear doors of locking arrangements by using suitable hinges complete all as specified and as directed.
S & F in replacement of aluminium strip of size 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground on and including suitable size of PVC / porcelein non conductive insulator fixed on roof / wall including connection up to test point complete all as specified and as directed.
Taking down and refixing of GI / aluminium strip of any size with saddles and fixing screws etc. for roof conductors and down conductors above ground on and including suitable size of PVC / porcelein non conductive insulator fixed on roof / wall including connection up to test point complete all as specified and as directed.
Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth lead wite 4 mm dia by means nut, bolt, check nuts and washer of galvanized iron as earth lead protected by provision of GI medium grade pipe 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr all as per electrical plate No.3 of SSR Part I and connecting to earth test point including testing complete all as specified and as directed.
Maintenance and servicing of DG Sets (B check) comprising prime mover and alternator with accessories, control panel and connected electric circuits with various type of sensors etc including checking lubricating oil, coolant, filters, V-belt, self starter, battery power, gauges and other connected accessories, cleaning of alternator with vaccum cleaner, attending faults of AMF panels and replacing the defective parts (as per B check i.e. filters, gasket kits, O ring, oil, coolant etc) and identifying malfunction of the DG Set of capacity 20 KVA (Model No. KG1-20WS) complete all as specified and as directed . Note :- (a) Spares of DG Set will be measured and paid seperately under relevent item of the CA catered as supply only. (b) Minor spares like nuts/bolts, washers, oil seal, gaskets, cotton waste, clamps shall deemed to be included in the rate quoted. (c) Labour component for fixing the spares during the servicing including testing the DG set is deemed to be included in the quoted rate.
All as per sl item No.104.00 here in before but DG Set of capacity 62.5 KVA (Model No. AL4CTIDG5)
All as per sl item No.104.00 here in before but DG Set of capacity 100 KVA (Model No. KG1- 100WS)
Dismantling radiator assembly from the engine of 20 KVA capacity DG sets by disconnecting inlet and outlet connection overhauling / servicing the radiator, descaling and servicing the radiator internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage, re assembling with necessary welding and additional bracket as required including refixing, reconnecting and testing for proper functioning complete all as specified and as directed.
All as per item No 107.00 here-in-before but for DG Set of capacity 62.5 KVA
All as per sl item No.107.00 here in before but DG Set of capacity 100 KVA
Dismantling of fuel injection pump assembly complete from the engine of DG Set of capacity 20 KVA , servicing, over hauling, replacement of valves, washers etc., assembling, calibration, setting for proper function, reassembling and re-fixing complete all as specified and as directed .
All as per item No 110.00 here-in-before but for DG Set of capacity 62.5 KVA
All as per item No 110.00 here-in-before but for DG Set of capacity 62.5 KVA
Disconnecting and taking down outgoing cables from the DG Set of capacity 20 KVA and cutting removing the burnt cable ends and thimbling and refixing back including provision of cable glands, lugs, tools and testing complete all as specified and as directed .
All as per item No 113.00 here-in-before but for DG Set of capacity 62.5 KVA
All as per item No 113.00 here-in-before but for DG Set of capacity 100 KVA
Supply only (in replacement) spin on fuel filter (pre and fine filter) element with O ring for DG Set of capacity 20 KVA
All as per item No 116.00 here-in-before but for DG Set of capacity 62.5 KVA
All as per item No 116.00 here-in-before but for DG Set of capacity 100 KVA
Supply only (in replacement) dry type Air filter element Inner and Outer unit as required at site with O' Ring of suitable for DG Set of capacity 20 KVA
All as per item No 119.00 here-in-before but for DG Set of capacity 62.5 KVA
All as per item No 119.00 here-in-before but for DG Set of capacity 100 KVA
Supply only (in replacement) Lub oil filter element with O Ring suitable for DG Set of capacity 20 KVA
All as per item No 122.00 here-in-before but for DG Set of capacity 62.5 KVA
All as per item No 122.00 here-in-before but for DG Set of capacity 100 KVA
Supply only (in replacement) by pass filter element with O ring of suitable for DG Set of capacity 20 KVA
All as per item No 125.00 here-in-before but for DG Set of capacity 62.5 KVA
All as per item No 125.00 here-in-before but for DG Set of capacity 100 KVA
Supply only (in replacement) V-belt suitable for DG Set of capacity 20 KVA
All as per item No 128.00 here-in-before but for DG Set of capacity 62.5 KVA
All as per item No 128.00 here-in-before but for DG Set of capacity 100 KVA
Supply only (in replacement) of water pump assy suitable for DG Set of capacity 20 KVA
All as per item No 131.00 here-in-before but for DG Set of capacity 62.5 KVA
All as per item No 131.00 here-in-before but for DG Set of capacity 100 KVA
S & F in replacement of common rail diesel sensor suitable for DG Set engine complete all as specified and as directed .
S & F in replacement of water outlet and inlet hose pipe from radiator to Engine and back from Engine to radiator complete all as specified and as directed.
S & F in replacement of Lub oil pipe armoured of suitable length and socket size complete all as specified and as directed.
S & F in replacement of Anti vibration rubber pad for side radiator complete all as specified and as directed.
S & F in replacement of Lub oil pressure guage 0 to 10 kg / sq cm complete all as specified and as directed.
Supply and top up coolent oil complete all as specified and as directed.
Supply and top up Engine oil 15W40 grade complete all as specified and as directed.
Supply and replace battery connecting single core copper cable 16sqmm with battery terminal made of brass with nuts/bolts/washer complete all as specified and as directed.
Supply and top up battery distilled water complete all as specified and as directed.
S & F in replacement of SMPS battery charger 12V/24V DC including all fixing accessories and re-wiring with suitable size copper conductor FRLS grade PVC insulated two core cable drawn through PVC conduit not less than 20mm dia as required at site and complete all as specified and asc directed.
Disconnecting, dismantling 12V/24V battery charging alternator assembly replacing the unserviceable burnt coil assembly, re-assembling, refixing to engine and testing for satisfactory charging of battery complete all as specified and directed.
S & F in replacement of AVR (Auto Voltage Regulator) suitable for 20 KVA capacity Gen Set having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4 A DC voltage regulation +/- 1% average volts, over excitation current tripping fuse protection 4A, fast acting and frequency 50Hz complete all as specified and directed.
All as per item No 145.00 here-in-before but for 62.5 KVA capacity
All as per item No 145.00 here-in-before but for 100 KVA capacity
S & F in replacement of Digital DG controller suitable for any type DG Set of any capacity and connecting with existing electrical circuit complete all as specified and as directed.
S & F in replacement of Diods set (Rectifier) of main alternator of DG Set of capacity 20 KVA complete all as specified and as directed.
All as per item No 149.00 here-in-before but for DG Set capacity 62.5 KVA
All as per item No 149.00 here-in-before but for DG Set capacity 100 KVA
S & F in replacement of contactor 4 pole, 63A, coil volt-240volts, AC 50Hz com plete all as specified and as directed
S & F in replacement of contactor 4 pole, 100A, coil volt-240volts, AC 50Hz com plete all as specified and as directed
S & F in replacement of CT coil with CT Ratio 100/5A, 5VA Cl 1.0 accuracy all as per IS 2705-1992 complete all as specified and as directed.
S & F in replacement of fuse unit 12 V DC (as per sample) suitable of DG Set of capacity 20 KVA control pane complete all as specified and as directed.
All as per item No 155.00 here-in-before but for DG Set capacity 62.5 KVA
All as per item No 155.00 here-in-before but for DG Set capacity 100 KVA
Minor repair / cleaning of fuel tank, removing sludge, arresting leak using metal paste / sealent or by welding / soldering, replacement of diesel receiver pipe from lock to tank with clamp set all as required at site for DG Set of capacity 100 KVA complete all as specified and as directed.
Minor repair to canopy such as to hinges, locking arrangement etc and painting inside /outside area of DG Set 20 KVA comprising engine, alternator, genset panel board and fuel tank and canopy, as per standard approved colour code with one coat of synthetic enamel paint cleaning scrubbing of all surface including writing by paint the SM/MES numbers etc complete all as specified and as directed.
All as per item No 159.00 here-in-before but for 62.5 KVA Genset
All as per item No 159.00 here-in-before but for 100 KVA Genset
Dismantling, removing the self starter, motor from the engine of DG Set of capacity 20 KVA , opening the self starter body and overhauling / servicing, replacement of carbon brushes with holders, contact plates, jumping leads and seals, re-varnishing the field coil, armature, re-assembling, testing for smooth functioning and re-fixing with the engine and connecting complete all as specified and as directed.
All as per item No 162.00 here-in-before but for 62.5 KVA Genset
All as per item No 162.00 here-in-before but for 100 KVA Genset
S&F asbestos rope 12 mm dia wrapped over the exhaust pipe and painting with heat proof paint of approved colour including taking down the old rope complete all as specified and as directed.
S & F in replacement of LED phase indicator lamp assy RYB complete all as specified and as directed.
S & F in replacement of water separator suitable for DG sets of capacity 20 KVA complete all as specified and as directed.
All as per item No 169.00 here-in-before but for 62.5 KVA Genset
All as per item No 169.00 here-in-before but for 100 KVA Genset
Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth lead 32x6 mm size, by means nut, bolt, check nuts and washer of galvanized iron and 32x6 mm as earth lead protected by provision of GI light grade pipe 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr all as per electrical plate No.3 of SSR Part I and connecting to earth test point including testing complete all as specified and as directed.
S&F DG Set diesel tank lock (as per sample) with fixing accessories complete all as specified and directed.
Checking of AMF panels including replacement of unserviceable parts such as relays, timers, power contactors, Auxilary contactors, defective copper wiring, MCCBs etc., for DG Set complete all as specified and directed. Note: - Spare parts shall be measured and paid separately under Supply only items
Supply only Auxiliary contactor 240 V 3 No & 1 NC
Supply only ON and OFF delay timer 240 V AC
Supply only Earth fault relay.
Supply only Over load relay.
Supply only Under voltage relay.
Supply only Power Contactor MCX22, 100 Amp 4 Pole
Supply only Power Contactor MCX11, 4 Pole
Supply only Power Contactor MNX 70, 3 Pole, 415 V including necessary wiring complete
Supply only Power Contactor MNX 110, 3 Pole, 415 V including necessary wiring complete
Supply only DC power contactor for auto starting 12 V
Supply only Power Contactor MCX 33, 4 Pole
Dismantling of 62.5 KVA capacity alternator from Generator after Dismantling from Generator shifting to workshop, taking out burnt out winding from stator & rotator, cleaning thoroughly and rewinding the stator with suitable guage of super enameled copper conductor similar to that of existing size including necessary insulating material varnishing, heating, reassembling of alternator, bringing back to the site, refixing and installation and foundation with proper alignment, testing and commissiong complete all as specified and as directed. Note :- Transportation from the site to workshop and back and labour element is deemed to included in rate quoted.
All as per item No 186.00 here-in-before but for 100 KVA Genset
S & F in replacement of LED flood light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and as directed.
S & F in replacement of aviation obstruction light including all connections complete all as specified and as directed.
S & F in replacement of LED bollard lighting of 8 W energy saving and environmental friendly long life aesthetically designed aluminium landscape IP 65 luminare for diffused lighting with high power LED as light source including all connections complete all as specified and as directed.
S & F in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete all as specified and as directed.
S & F in replacement of post top lantern LED light fitting 20 Watt 230 V AC outdoor type with decorative post top for 360 degree indirect light with impact and corrosion resistant of IP 66 protection complete all as specified and as directed.
Complete removal of existing paint of steel tubular poles length up to 9 mtr including prepration of outer surface and applying two coats of aluminium paint over a coat of red oxide primer and two strip of blue colour paint of size 30 cm width from bottom of pole at a height 30 cm, including numbering to pole with base paint of yellow colour and Black for numbering which shall not be less than 100 mm in height and 10 mm in width complete all as specified and as directed.
S&F in replacement of three core copper cable of size 2.5 Sqmm for street light fittings complete all as specified and as directed.
S&F in replacement of five core copper cable of size 2.5 Sqmm for high mast light fittings complete all as specified and as directed.
S & F in replacement of street light brackets made out of 40mm bore GI tubing, light grade, 1.5m long, bent to required shape, including necessary bending, welding, etc fixed with 2Nos. clamps made out of 32x5mm GI strip including necessary drilling holes, screws, nuts, bolts, etc complete all as specified and as directed .
S & F in replacement of aluminium strip of size 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors including all connections complete all as specified and as directed.
Taking down and refixing only of existing aluminium / GI strip of size 25/32 mm on wall /roof with and including PVC stripholder with necessary screw / nut bolts complete all as specified and as directed.
S & F in replacement of Air termination, single pointed, aluminium rod 12mm dia and 300mm long including all connection complete all as specified and as directed.
S & F in replacement of street light pole FRP junction box with aluminium bus bar suitable for mounting 01 No. MCB SP with locking hinge and aluminium clamp made out of 25X3mm thick complete all as specified and as directed.
Taking down high mast light fittings manually from 12m height steel pole and disconnecting the SS rope and replace the unserviceable the parts such as double drum winch, 5mm diameter SS wire rope 5 runs, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial , outdoor stand mounted feeder pillar box and made the High Mast light fully functional and raising the hight Mast light fittings in its original postion and testing complete all as specified and as directed . (i) Cost of miscelleneous items which are not mentioned above but are required for satisfactory completion deemed to be included in the rate quoted by the contractor. (ii) Oiling/greasing for chain / rope, motor rewinding, Auto / Manual function of Timer panel etc. deemed to be included in the unit rate quoted. (iii) LED flood lights,Timer, Aviation light, Cable will be measured and paid separately under the relevant items of this schedule
Dismantling the centrifugal / submesible pump set of capacity 1 HP and transportation to workshop for replacing unserviceable parts such as impeller,shaft, bearing, winding etc and reconnecting back the pumpset to its original position after repair and testing complete all as specified and as directed.
All as per item No.202.00 here-in-before but of capacity 1. 5 HP
All as per item No. 202 here-in-before but of capacity 2.0 HP
All as per item No. 202 here-in-before but of capacity above 2.0 HP but less than 5 HP
S&F in replacement of star / delta starter 3 phase, 440 V, 50 Hz with relay rating 14-25 A suitable for motor capacity up to 5 HP including testing complete all as specified and as directed .
Disconection and removing the defective DOL starter and S & F the new DOL starter three phase 440 Volts , 50 Hz suitable for motor capacity up to 5 HP including testing complete all as specified and as directed.
Disconection and removing the defective DOL starter and S & F the new DOL starter single phase 240 Volts , 50 Hz suitable for motor capacity including testing complete all as specified and as directed.
S&F in replacement of over current relays suitable for single phase DOL starter including testing complete all as specified and as directed .
S & F in replacement of PVC foot valve of 65 mm bore complete all as specified and as directed.
All as per item No.210.00 here-in-before but of 50 mm bore.
All as per item No. 210.00 here-in-before but of 40 mm bore.
All as per item No. 210.00 here-in-before but of 32 mm bore.
S&F in replacement of CPVC ball valve of 25 mm bore complete all as specified and as directed.
All as per item No. 214.00 here-in-before but of 32mm bore.
All as per item No. 214.00 here-in-before but of 40 mm bore.
All as per item No. 214.00 here-in-before but of 50 mm bore.
Supply & laying in replacement of CPVC pipes of 25mm bore SDR 13.5 and plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete all as specified and as directed .
All as per item No. 218.00 here-in-before but of 32 mm bore.
All as per item No.218.00 here-in-before but of 40 mm bore.
All as per item No. 218.00 here-in-before but of 50 mm bore
S&F in replacement of CPVC brass elbow of 25 mm bore complete all as specified and as directed.
All as per item No. 222.00 here-in-before but of 32 mm bore
All as per item No. 222.00 here-in-before but of 40 mm bore
All as per item No. 222.00 here-in-before but of 50 mm bore
S&F in replacement of CPVC brass tee of 25 mm bore complete all as specified and as directed
All as per item No. 226.00 here-in-before but of 32 mm bore
All as per item No. 226.00 here-in-before but of 40mm bore
All as per item No. 226.00 here-in-before but of 50mm bore
S&F in replacement of CPVC male brass threaded adaptor of 25 mm bore complete all as specified and as directed
All as per item No. 230.00 here-in-before but of 32 mm bore
All as per item No. 230.00 here-in-before but of 40mm bore
All as per item No. 230.00 here-in-before but of 50mm bore
S&F in replacement of CPVC female brass threaded adaptor of 25 mm bore complete all as specified and as directed
All as per item No. 234.00 here-in-before but of 32 mm bore
All as per item No. 234.00 here-in-before but of 40mm bore
All as per item No. 234.00 here-in-before but of 50mm bore
S&F in replacement of CPVC union of 25 mm bore complete all as specified and as directed
All as per item No. 238.00 here-in-before but of 32 mm bore
All as per item No. 238.00 here-in-before but of 40mm bore
All as per item No. 238.00 here-in-before but of 50mm bore
Construction of 200mm thick PCC solid block wall masonary valve chamber built in CM 1:6 with 150mm thick PCC foundation 1:2:4 type B-1 coping 50mm thick finished even and smooth, rendering 10mm thick in cement mortar (1:6), finished fair and and even externally including excavation earthwork in any strata, 6mm thick MS sheet cover fixed on angle iron frame 25x4mm embedded in PCC coping with locking arrangement and mild steel hold fast, mild steel handles and painting to steel surface with two coats of black bituminus paint over one coat of red oxide primer etc, for internal size 600x600x600mm including the demolishing PCC chamber complete all as specified and as directed .
R.K. Builders (BID ID -3167249)
STANDARD ENGINEERING (BID ID -3173950)
Jack Electrolinks Private Limited (BID ID -3171663)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .