Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 Cr+₹11.2 L (7.36%)Rejected-AOC | ₹1.6 Cr+₹11.2 L (7.36%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.7 Cr+₹20.5 L (13.5%)Rejected-AOC 539 A PURBACHAL MAIN ROAD HALTU KOLKATA 700078 | KOLKATA | WEST BENGAL | 700078 | ₹1.7 Cr+₹20.5 L (13.5%) | L3 | Rejected-AOC L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Qualified |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
29 Nov 2019, 5:30 pmClosed
SE(E/M)-II, KMDA
OFFICE OF THE SUPERINTENDING ENGINEER (E/M)-II, E-M SECTOR, K.M.D.A. UNNAYAN BHAVAN, 6th FLOOR, SALT LAKE CITY, KOLKATA 700 091.
Supply, delivery, erection, testing and commissioning of fire fighting, detection and control system and allied works as phase-I for Logistic Hub at Garden Reach.
2019_KMDA_250800_1
SE(E/M)-II/2W-64/2019-20/339
Open Tender
Electrical Work/ Equipment
Item Rate
120 days
Garden Reach.
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹2 L
OFFICE OF THE SUPERINTENDING ENGINEER (E/M)-II
9 Jan 2020
1 Nov 2019
2 Dec 2019
1 Nov 2019
29 Nov 2019
1 Nov 2019
13 Nov 2019
Amount
Supply, installation, testing & commissioning of the following MS ERW black pipe
Supply, installation, testing & commissioning of Landing Valve (Single Outlet).
Supply, installation, testing & commissioning of Hose Box (Single Door).
Supply, installation, testing & commissioning of Landing Valve (Double Outlet).
Supply, installation, testing & commissioning of Hose Box (Double Door).
Supply, installation, testing & commissioning of 63 mm dia, 15m Long Rubberized Lined Hose.
Supply, installation, testing & commissioning of Standard short size Branch Pipe.
Supply, installation, testing & commissioning of Gun metal Spring loaded 25 NB Air release vallve.
Supply, installation, testing & commissioning of First aid Fire Hose Reel Drum Wall Mounting.
Supply, installation, testing & commissioning of Ball valve 25 NB with all necessary accessories and fitting.
Supply, installation, testing & commissioning of 3 Way Fire Brigade Inlet Head.
Supply, installation, testing & commissioning of rising spindle type gate valve complete with matching flanges, rubber insertion, nuts, bolts & washer etc of following sizes complete in all necessery fittings.
Supply, installation, testing & commissioning of swing type non return valve complete with matching flanges, rubber insertion, nuts, bolts & washer etc of following sizes complete in all necessery fittings.
Supply, installation, testing & commissioning of the following Butterfly Valve.
Supply, installation, testing & commissioning of 68 degree pendent type sprinkler.
Supply Installation, Testing & Commissioning of horizontal centrifugal type MOTOR DRIVEN MAIN FIRE PUMP along with suitable motor, AVM pad and other neccessery accessories and fittings.
Supply Installation, Testing & Commissioning of horizontal centrifugal type Engine DRIVEN FIRE PUMP suitable rated engine, AVM pad and other neccessery accessories and fittings.
Supply Installation, Testing & Commissioning of horizontal centrifugal type Motor DRIVEN JOKEY PUMP along with suitable motor, AVM pad and other neccessery accessories and fittings.
Supply Installation, Testing & Commissioning of the following Foot valve
Supply Installation, Testing & Commissioning of pressure switch set -differential type , including piping & complete in all respects as required.
Supply Installation, Testing & Commissioning of dial type pressure gauge of 100 mm dial, including piping & complete in all respects, including Ball valve, as required.
Supply Installation, Testing & Commissioning of suitable control panel for Pump motor.
Supply Installation, Testing & Commissioning of the following Power Cable Al.1.1KV Gr PVC alongwith Gland,lugs,etc , as required, all complete.
3C x 95 sqmm
2C x 1.5 sq.mm
Supply, installation, testing & commissioning of suitable sub-marsible pump including all fittings & accessories with starter panel and cable.
Construction of suitable pump house as required, including supply of all sorts of materials, all complete.
Supply, installation, testing & commissioning of CO2 type Fire Extinguisher of capacity 4.5 kg.
Supply, installation, testing & commissioning of CO2 type Fire Extinguisher of capacity 9 kg.
Supply, installation, testing & commissioning of Stored Pressure (ABC Dry Chemical Powder) type Fire Extinguisher of Capacity 6 kg.
Supply, installation, testing & commissioning of steel fire door.
Supply, installation, testing & commissioning of safety signage.
Supply, installation, testing & commissioning of addressable SMOKE DETECTOR.
Supply, installation, testing & commissioning of addressable MANUAL CALL POINT.
Supply, installation, testing & commissioning of addressable MONITOR MODULE.
Supply, installation, testing & commissioning of addressable Control Relay Module.
Supply, installation, testing & commissioning of addressable Sounders.
Supply, installation, testing & commissioning of addressable FIRE ALARM CONTROL PANEL.
Supply, installation, testing & commissioning of addressable REPEATER PANEL.
Supply & Laying of 2 core 1.5 sq.mm with neccessery accossories & fittings.
Supply, installation, testing & commissioning of addressable PUBLIC ADDRESS SPEAKER.
Supply, installation, testing & commissioning of addressable CALL STATION.
Supply, installation, testing & commissioning of addressable AMPLEFIER.
Supply, installation, testing & commissioning of addressable CONTROLLER.
GANPATI PROJECTS PRIVATE LIMITED
Firemax Safety & Security Pvt.Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .