Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.5 LAccepted-AOC | L-1 | Accepted-AOC Being Lowest and reasonable | |
| 2 | L-2₹29.6 L+₹1.9 L (6.84%)Rejected-Finance RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹33.1 L+₹5.4 L (19.5%)Rejected-Finance C O SIMPLICITY LYNGDOH LOWER LUMPARING LABAN SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹33.3 L+₹5.6 L (20.3%)Rejected-Finance RONGMEN BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹33.8 L+₹6.1 L (22.2%)Rejected-Finance RONGMEN B IV BARAPANI PO SHILLONG 793103 | RI BHOI | MEGHALAYA | 793103 | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
22 Sept 2023, 6:00 pmClosed
GE Umroi
Military Engineer Services Garrison Engineer Umroi Umroi Military Station PO - Barapani, Shillong-793 103
SPL REPAIR OF LEAKAGE and SEEPAGE and SUNKEN WORK, PROVN OF TILING and MW NO 02, 04, 06 and 08 AT UMROI MIL STN UNDER GE UMROI
2023_MES_615812_1
8739/E8
Open Tender
Civil Works
Item Rate
180 days
GE Umroi
As per NIT
8 documents required · 8 mandatory
₹500
GE Umroi
₹65,000
14 Nov 2023
26 Aug 2023
23 Sept 2023
26 Aug 2023
22 Sept 2023
9 Sept 2023
Amount
Surface dressing n exc 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils, complete all as specified and directed.
Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
Material and labour for Cement concrete, type D2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed
M&L for plain cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed.
M&L for 75mm thick PCC(1:4:8) type 'D-2' (using 40mm graded crushed stone aggregate) as in path/Hardstanding, complete all as specified and directed.
M&L for RCC Design Mix M-25 in Foundation, including raft footings, foundation beams, plinth beams, bases for column etc., basement slabs, underreamed piles and mass concrete etc, complete all as specified and directed.
M&L for RCC Design Mix M-25 in Beams, cantilevers, lintels, columns pillars, piers, posts, struts, chullah hoods, stair case, arches, domes, vaults, shell roofs, arch ribs, folded plates, slabs, balconies, canopies, deckslabs etc. or in similar articles etc , complete all as specified and directed.
M&L for RCC for M 25 (Design Mix) using 20 mm graded crushed stone aggregate as in chajjas and similar work, compete all as specified and directed.
Material and labour for Reinforced cement concrete M-20 nominal mix (using 20 mm graded aggregate) as in drain Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses, complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore, complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type C1 using 20 mm graded aggregate as in plinth protection finished fair and even with using extra cement, complete all as specified and as directed.
M&L for PCC (1:2:4) type B0 (using 12.50 mm graded aggregate) as in surface channel and drain, complete all as specified and directed.
Material and labour for Pre-cast cement concrete block masonry, type C1 (1:3:6), (using 20mm graded stone aggregate), in cement mortar 1:6 with solid blocks, exc. 10 cm in width and setting in mortar, complete, complete all as specified and directed.
Use and waste of formwork to sides of column, pillars, posts, stanchions for rough finished surface, complete all as specified and as directed.
Use and waste of formwork to sides and soffit of beams, lintels, cantilevers, shelves etc for rough finished surface complete all as specified and as directed
Use and waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter(Flat) complete all as specified and as directed.
Use and waste of Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed.
Material and labour for Formwork to faces of drain walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for fair finished surfaces, complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
Taking down chowkats or frame exc 1.50 sqm but n.exc 4.00 sqm with shutters (without taking off shutters from the frame), complete all as specified and directed.
Taking down chowkats or frame n.exc 1.50 sqm with shutters (without taking off shutters from the frame), complete all as specified and directed.
Refixing of shutter in same opening after repairing complete area exc 1.00 Sqm but not exc 2.00 Sqm, complete all as specified and directed.
Taking down shuuter of any description exc 1.00 sqm but not exc 2.00 sqm each, complete all as specified and directed.
S&F Factory made solid PVC door frame of size 50mm x 95mm made out of 5mm wood grain printed single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet, complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter 28 to 30mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm PVC sheet on back face, fixing in frame at site as per specification & drawing, complete all as specified and directed.
S&F Pressed steel frames of frame size 105x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and directed. Note : Filling of hollow of frames with PCC (1:2:4) type B0 shall be measured and paid seperately.
S&F Pressed steel frames of frame size 125x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified Note : Filling of hollow of frames with PCC (1:2:4) type B0 shall be measured and paid seperately.
S&F 35 mm thick Factory made 2nd class hard wood plain framed panelled shutter (two panels ) with lock rail and panel of 9mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces . The size of rail and stile as per IS:1003(Part-I), klin seasoned and chemically pressure treated, complete all as specified and directed.
M&L prelaminated particle board 18/19mm thick in repair as in cup board shutter and Shelf, interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to timber frame works complete all as specified and directed.
Material & Labour for Preparation of old surface applying two coats of synthetic enamel paint on old steel surfaces of any description over 10 cm wide or girth incl preparation of surface etc., complete all as specified and as directed.
Material & labour PCC 1:2:4, type B0 (12.5mm graded agg.) for fixing hold fasts, angle etc complete all as specified and directed.
Material & labour flat iron mild steel for hold fast size conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube fixed as per manufacturer instructions complete all as specified and directed.
S&F plain colour Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing etc complete all as specified and directed.
Supply and fix anodised powder coated (minium thickness 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and directed.
Supply & Fix Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters (sliding type), aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading screws etc, complete all as specified and as directed.
S&F aluminium powder coated [Minimum 50 Micron thick] anodised aluminium sliding frame and shutter for windows/ventilation with 92 mm x 31.75 mm x 1.5 mm thick three track section for frames and 40 x 18 x 1.50 mm thick sliding section for shutters of both gauzed and glazed with 4 mm thick tinted glass, aluminium Deco Grill of Model / Design No. DG 104 and stainless steel wire cloth [0.63 mm nominal dia and avg width of aperture 1.40 mm] including necessary jointed, cleats powder coated glazzing clips, powder coated aluminium snap beadings, screw and aluminium fittings, suitable handle, complete all as specified and directed.
Supply and fix aluminium anodised (powder coated) Three track sliding window frame with shutters with (2 nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete and glazing with and including 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter (A) Sections for shutter (i) 'H' section 39 x 20 x 1.50 mm thick (ii) 'Interlock' section 39 x 20 x 1.50 mm thick (iii) 'Edge & Bottom' section 41 x 20 x 1.50 mm thick (B) Section for frame (i) Top & Sides 123 X 29.70X 1.50mm not less than 1.30 Kg /RM (ii) Bottom 123 X 29.70 X 1.50mm not less than 1.502 Kg /RM complete all as specified and directed .
Material & Labour 4mm thick figured glass, n.exc 0.50 sqm each pan, pin headed type and glazing with oil putty or aluminium beads fixed to steel etc, complete all as specified and as directed
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, complete all as specified and as directed
S&F aluminium alloy handles size 150mm fabricated type anodised, complete all as specified and as directed
S&F aluminium anodised barrel tower bolt 200mm size of extruded section and fixed, complete all as specified and as directed
S&F 100 mm butt hinges medium weight cold rolled mild steel and fixed, complete all as specified and as directed
S & F 75 mm butt hinges medium weight cold rolled mild steel and fixed complete all as specified and directed.
S & F 300 mm long aliminium alloy ,anodised sliding door bolt with hasp and staples (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast alunimium alloy and fixed complete all as specified and directed.
S & F 100 mm hasp and staples of alunimium anodised, safty type including bolt to hinges plate and fixed with screws complete complete all as specified and directed.
S & F helical door spring 300mm long incl roller and roller plate complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish of the premises, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, walls etc, laid , bedded and pointed in any mortar, complete all as specified and directed.
M&L 100 mm thick PCC 1:2:4 Type B-2 ( using 40 mm graded crushed stone aggregate) as in sub base of floor, complete all as specified and as directed.
M&L for Hardcore of brocken Stone of gauge n exc 63mm deposited,spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified and as directed.
M&L Sand filling under inter locking paver block including watering and consolidation, complete all as specified and as directed.
M&L for Machine pressed precast concrete interlocking rubber moulded paver block with grey cement and colour pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade, complete all as specified and as directed.
M&L for (1:2:4), type B0 (using 12.50mm graded stone aggregate) as in cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, Copings, etc complete all as specified.
Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.00 kg of cement per sqm complete all as specified and directed.
M&L for Granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) over 15mm thick screed bed/bedding layer in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
M&L for Green Marble 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed.
M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exc. 0.18 sqm but n exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
Material and labour for coloured Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
Material and labour for non skid ceramics color tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm as in skirting over and set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing surface including 10mm thick rendering in CM 1:4 complete all as specified and directed.
S&F non skid ceramic coloured floor tiles 7 to 8mm thick etc area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing floor over and including 15mm thick screed bed or bedding of layers in CM 1:6, complete all as specified and directed.
Taking down cement plaster including racking out joints, hacking for key scrubbing down with water etc including removal of rubbish material from site complete all as specified and directed
M&L for 10mm thick plaster in cm (1:4) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and directed
M&L for 15mm thick rendering in CM (1:4) in two layers mixed with water liquid water proofing compound as per manufacture instruction in top layer 5 mm thick finishing the surfaces with fair and even without using extra cement of any description complete all as specified and directed. . Note: Liquid water proofing compound of Make - Conplast WL,Sika,Dr.Fixit measure separtely.
Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair all as specified.
Material and labour for 5 mm thick rendering in cement mortar (1:3) on fair faces of exposed/non exposed concrete surfaces such as soffits of slabs, chajja,fasia and simillar work in patches including mixing & application integral water proofing compound as per manufacture instruction of make Conplast WL,Sika,Dr.Fixit finishing the surfaces fair and even of any description, complete all as specified and directed. Note: Liquid water proofing compound shall be measured and paid seperately. Make - Conplast WL,Sika,Dr.Fixit measure separtely.
Material and labour for 15 mm thick rendering in cement mortar (1:6) on fair faces of brick surfaces finished even and smooth without using extra cement, complete all as specified and as directed
Supply only integral WPC ( Integral water proofing liquid admixture for cement mortar) and application as per manufacture instruction, complete all as specified and as directed Make - Conplast WL,Sika,Dr.Fixit
Material and labour for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.
M&L for prepration of new plastered surfaces and applying two coats of weather proof exterior emulsion paint (Apex Ultima or equivalent) (any colour/tint) with approved colour and pattern over a coat of 1 mm thick wall care putty and a coat of approved alkali primer as on walls of bldgs of any height including necessary scaffolding and safety measures and procedure complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats weather proof paints over one coat of primer as per manufacture instruction, complete all as specified and as directed.
Material and labour for three coats of white wash on newly plastered surfaces of ceiling including preparation of new plastered surafaces, complete all as specified and directed.
M&L for preparing surfaces of newly plastered surfaces on walls and applying two coat of distemper oil emulsion including 1.5mm thick internal wall putty with chalk whiting primer, complete all as specified and directed.
M&L for preparing surfaces of newly plastered on walls and applying two coat of acrylic smooth exterior paint including 1.5mm thick external wall puty with alkali resistant primer, complete all as specified and directed.
M&L for complete removal of existing treatment surfaces on walls and applying two coat of distemper oil emulsion including 1.5mm thick external wall putty with chalk whiting primer, complete all as specified and directed.
M&L for preparing surfaces of complete removal on walls and applying two coat of acrylic smooth exterior paint including 1.5mm thick internal wall puty with alkali resistant primer, complete all as specified and directed.
Material and labour complete removal of existing tretment and applying for three coats of white wash surfaces of ceiling including preparation of surafaces, complete all as specified and directed.
Material and labour for applying two coats of cement base paint over one coat of alkali resistant primer on plastered surfaces of walls including preparation of new or previously untreated surfaces all as specified and directed.
Material and labour for taking down of existing roof treatment from roof and terrace, roughening surface of old concrete roof by picking, sweeping clean and washing down with water to remove dust, etc and applying roof treatment with the following steps and specifications:- a) Applying crack seal compound of same manufacture of waterproof to fill all cracks of observed on the roof. b) Applying cement slurry over concrete surfaces @3kg/sqm. c) Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufactures’ instruction(not less than 3% by weight of cement) on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course). d) Applying evenly one coat of primer coating (diluted with water in the ratio specified by Manufacturers) (min @100-110Sq Ft per liter (diluted quantity)) on the cleaned plastered surfaces. The surface shall be left for air dry for minimum period of 2-3 Hrs. e) Applying evenly one coat of elastomeric water proof coat in one direction (as specified by Manufacturers)(min@ 0.9-1.0 sqm per ltrs) and allow to air dry for 4-6 hrs before applying second coat in other direction perpendicular to the first one (as specified by Manufacturers) (min @0.9-1.0 sqm per ltrs. The total thickness of two coats shall be 0.5 to 0.6 mm. f) The whole system shall be left for air cure for min Seven days (without any movement). Make : - Dr Fixit Newcoat Ezee or Berger Home Shield PU RoofKoat or Asian Paints Smartcare Damp Proof or as equivalent approved by GE. Note : - (i) The waterproofing shall be carried out in the last stage of execution to avoid any damages during the execution. (ii) Payment against this item shall not be allowed till completion of all the stages of work for any slab. (iii) The work shall be executed through Authorized well-trained applicators as per manufacturer’s instructions after obtaining written approval from the GE
S&F of Double Wall Corrugated (DWC) HDPE pipes 150 mm bore single socketed in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drains,making good to pipe & rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 150mm bore of pipe complete all as specified and directed.
S&F vitreous squating pan of orissa pattern long pan of size 580 mm x 440mm white with cast iron p or s trap with back inlet including foot rest flush pipe of suitable length to connection with existing cistern & make good, complete all as specified and directed.
S&F in repaire vitreous squating pan of orissa pattern long pan of size 580 mm x 440mm white with cast iron p or s trap with back inlet including foot rest flush pipe of suitable length to connection with existing cistern & make good, complete all as specified and directed.
S&F PVC valve less syphonic action flushing cistern type 9 to 10 ltrs capacity with inlet, ball valve, float and handle including bracket, white colour, complete all as specified and as directed
S&F in repair PVC valve less syphonic action flushing cistern type 9 to 10 ltrs capacity with inlet, ball valve, float and handle including bracket, white colour of approved make, complete all as specified and as directed
S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc, complete all as specified and as directed
S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc, complete all as specified and as directed
S&F 15 dia fancy type chromium plated Bib tap cast copper alloy etc complete all as specified and as directed.
S&F stop valve 15 mm dia CP fancy type, with long shank and cup (concealed type) cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs of stop valve 15 mm dia CP fancy type, with long shank and cup (concealed type) cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F stop valve 15 mm dia CP fancy type, with long shank and cup cast copper alloy, screwed both ends for iron pipe or for unions, complete all as specified and directed.
S&F 15 mm dia fancy type pillar tap cast copper alloy, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe & fixed, complete all as specified and directed.
S&F Shower Rose 125mm size Chromium plated with swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed.
M&L for CI floor trap with grating for 100mm dia outlet pipe, including making good distrubd area/surfaces with cement concrete/cement mortar 1:2:4 etc complete all as specified and as directed.
S&F in repair kitchen sink of size made out of 1mm thick sheet of overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm plug washer brackets, connecting union, 40 mm dia waste pipe etc including taking down old one, incl waste pipe and 40mm waste coupling complete all as specified and directed.
S&F Stainless steel kitchen rack / plate rack of size 31" x 36" x 10" , made of stainless steel sheet 0.63 mm thick etc complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and as directed.
S&F of wash hand basin, white flat back of size 550 x 400mm excluding piller taps but including waste cupling, waste pipe and bracket etc, complete all as specified and as directed.
S&F in repair wash hand basin, white flat back of size 550 x 400mm excluding piller taps but including waste cupling, waste pipe and bracket etc, complete all as specified and as directed.
S&F 500 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical verticle with closed top) noisfed and fixed in position, complete all as specified and as directed.
S&F 1000 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical verticle with closed top) noisfed and fixed in position including taking down old one complete all as specified and directed.
S&F in PVC ball valve 20mm high pressure of PTM with epoxy coated aluminium rod and high density plastic ball serewed for iron pipe fixed, complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of camouflage colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self taping screws, complete all as specified and as directed.
Material and Labour Rolled mild steel section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410-W (Gde-E-250) quality A, complete all as specified and as directed.
Material & labour preparation of new steel surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and as directed.
M&L for Providing and fixing false ceiling of designer tile ivory/white painted (high pressure steam cured ) of 4mm thick (as per IS: 14862) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level. Suspended on inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs)consisting of main T runner with suitably spaced joints to get required length and 15x32mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 15x32mm made of 0.3mm sheet 1200mm long spaecd between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 15x32mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width, complete all as specified and as directed.
M&L sunken treatment of Toilet/Bathroom as in following steps: i) Top of RCC slab in sunken portion including peripheral beams shall be plastered with 15mm thick in cement mortar 1 : 3 using approved water proofing compound @ 3% by weight of cement finished even and smooth using extra cement, curved at the junctions. ii) Apply two coats of epoxy resin/polymer modified cementations coating like brush bond of FOSROK/SIKA/Pedilite or equivalent, both on floor & beams. iii) Sunken slabs to be given 1:20 slope outward 25mm GI pipe spout with 300 mm projection beyond outer surface of wall shall be provided. iv) Water tightness of sunken portion to be tested by ponding with water for 72 hours. In case of even a slight mark of seepage, the portion to be treated and ponding shall be carried out again to confirm the water tightness of sunken slab. v) The sunken portion will be filled with lean concrete 1:4:8 type D2 using brick aggregates to required depth. Note:- No cutting in roof slab/beam shall be allowed for passing of CI pipes & fittings.The stage of water proofing to sunken slab shall be passed by Eng-in-charge/GE.
Demolition of cement concrete of any dsecription and in any position not otherwise specifically provided for etc, complete all as specified and directed.
M&L for PCC 1:5:10 Type E2 (using 40mm graded crushed stone aggregate) as in filling sunken floor, complete all as specified and directed.
Taking up or down steel tubing 15mm bore and connections including cleaning for refixing or removal to store, complete all as specified and directed.
Demolition cement concrete (un-reinforced) of any descriptions not exc. 150mm thick, above or below Ground Level using concrete cutter and making good same as previous to the effected area, complete all as specified and directed
Material and labour for PCC 1:2:4 type B2 (Using 40mm graded stone aggregate) as in surface channels and drains etc, cement complete all as specified and directed
Demolition of precast cement concrete block walling in any position, built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Material and labour for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Add or deduct to the item no. 119 above for each 25mm girth or part thereof over or under 30cm complete all as specified and directed
Demolition of RCC of any description and in any position not otherwise specifically provided for including taking out and seperating old reinforcement and removal of debries to a distance not exc 50m as directed by Engineer in charge and making site clean complete all as specified and directed.
M&L for pre cast RCC 1:2:4 type B-1 as in in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles set in cement mortar 1:6 complete all as specified and as directed.
Cleaning of existing road side culvert/drain using mechanical means and removing solid/liquid mud,vegitation debries or simillar items and depositing the same n.exc 1.50 Km and including removal & refixing of covers, complete all as specified and directed.
Taking down carefully old unsv copper/aluminium point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. to be measured separately) and removing materials to store for keeping in safe custody for reuse at site or for taking credit and making good to disturbed surfaces of walls, floors etc with its original specification, complete all as specified and directed.
Taking down carefully MCB DBs SP/TPby unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed.
Material and labour for concealed point wiring with 1.5 Sqmm PVC insulated and sheathed multi stranded (FRLSH) flexible copper conductor cable in and incl rigid PVC conduit concealed /PVC surface conduit with sunk cast iron/pressed steel terminal boxes of adequate size with suitable thickness hylum laminated sheet, cover of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm (FRLSH) PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed. Note: a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc (b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed
All as per serial item No 126 here in before but for one 3 pin 5 Amp socket outlet on independent board.
All as per serial item No 126 here in before but for one 3 pin 5 Amp socket outlet on same board.
All as per item No 126 here-in-before but using 2.5 sqmm PVC FRLSH insulated copper condutor wire for connecting 15A socket on independent board.
Supply and fixing of switch piano flush type 240 Volts 5 Amps, SP, one way, complete all as specified and directed.
Supply & fixing of socket 3 pin 5 Amps 240 Volts flush type (non shuttered), complete all as specified and directed.
Supply and fixing of switch socket outlet combination 3 Pin,5 Amps, 240 volts flush type (non shuttered) in independent board, complete all as specified and directed.
Supply and fixing switch socket out let combination multipurpose 3 pin, 5/16 Amps and (with 3 pin 5 Amps outlet also) flush type (non shuttered), complete all as specified and directed.
Supply and fixing ceiling rose surface PVC/Polycarbonate, 65x50 mm two to three terminals, complete all as specified and directed.
Supply and fix MCB SPN DB 4 way double door,IP 43 protection,Glazed door, isolated neutral bar,insulated bus bar assembly,mechanical strength of IK09, complete all as specified and directed.
Supply and fix MCB SPN 32 Amps 'B' Series 10 Ka,240 volts complete all as specified and directed.
Supply and fix MCB SP 6 to 32 Amps 'B' Series 10 Ka,240 volts complete all as specified and directed.
Supply and fixing Bulb angular/batten holder PVC/Polycarbonate suitable for batten fittings including one No LED Lamp of 9W, complete all as specified and directed.
Supply and fixing compact commercial batten suitable for single T8 LED tube fitting 1x18/20 watts including Tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23.0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed.
M&L for cutting of circular hole at any type of wall suitable size for fixing of exhaust fan of size 300mm sweep, grouting 04 Nos 100mm long 12mm dia stud bolt including,making good to disturbed surfaces of wall and colour wash to match as per the existing colour, complete all as specified and directed.
Supply & fix Ventilating fans, Non mettalic body, AC single phase 230/ 240 V of size 250 mm sweep with louver including making hole and fixing arrangement and making good disturbed surface complete all as specified and directed.
Supply & fixing ceiling fan regulator electronic,Deluxe,rotary, step type, 120/280 V, complete all as specified and directed.
S&F of Ceiling fan 1200 mm (minimum) sweep, BEE 5 star rated with BLDC technology, AC single phase 230 volt, without remote Suspended from fan hook and including electrically connecting with twisted three core PVC insulated unsheathed flexible cord of 0.75 sqmm copper conductor from ceiling rose to ceiling rose to ceiling fan complete all as specified and directed. Make:- Usha Model- ENERGIA 32, Havells Model- EFFICIENCIA NEO or equivalent in Orient/Bajaj. Note:- Old unservisable ceiling fans shall be deposited to MES store.
Supply and fix in repairs of MCB SPN DB 8 way double door,IP 43 protection,Glazed door, isolated neutral bar,insulated bus bar assembly,mechanical strength of IK09, complete all as specified and directed.
Taking down aluminium submain wire along with damaged casing caping /PVC conduite pipe from the wall roof or floor and making good distrubed surface, complete all as specified and directed.
S&F sub main wiring with three run of single core (FRLSH) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 6.0 Sqmm drawing into and including PVC casing and caping of adequate size with proper colour coding and making electric connections , including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of sinking for boxes cutting and making holes in wall/floor for passing in or through casing caping (ii) Three run of 6.00 sqmm single core (FRLSH) PVC insulated copper conductor cable and one run of PVC casing caping of suitable size will be measured as a one unit.
Supply only LED bulb of 7 Watt (Warm white). Make- BAJAJ B22 or equivalent to Philips/ CG/Havells
Supply and fixing LED light fitting mirror type with high output diffuser 2 ft ,10 watt 220 Volt AC Decorative type with driver holder and LED Lamp Including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
Schedule of Credit
M/s UB Enterprise
Lyngdohs Construction Company And Associates
M/S SUBHASH BHATTACHARJEE
M/s Jaiswal and Co
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .