Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAdmitted-Fee/PreQual/Technical/Finance 105 B BLOCK SMS LAKE VIEW APARTMENT UKKADAM BYE PASS ROAD COIMBATORE 641 001 | COIMBATORE | COIMBATORE | TAMIL NADU | 641001 | L1 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | S RAJU L1 |
|---|---|---|---|---|
| 1.10 | Supply, Erection, Testing and Commissioning of 82.5 kVA, 3-Phase, 415 V, 50 Hz, CPCB IV+compliant Diesel Generator Set, complete with acoustic enclosure, suitable diesel engine and alternator, Inbuilt AMF (Automatic Mains Failure) logic control panel, Inbuilt Remote Monitoring system, automatic battery charging facility and all standard accessories, including necessary cabling, connections, installation, testing and commissioning, complete in all respects as per applicable standards and manufacturer’s recommendations. a. Power Cable: Supply and laying of 3.5 Core × 120 sq.mm, ISI-marked Aluminium XLPE insulated, PVC sheathed power cable, including suitable cable routing, laying accessories and cable end termination with suitable glands, lugs and accessories at both ends. b. Main Switch: Supply and fixing of 100 A, suitable-rated Main Switch, complete with enclosure and necessary accessories. c. Changeover Switch: Supply and fixing of 125 A, 4-Pole Changeover Switch, suitable for DG/Mains changeover, complete with enclosure and accessories. d. Copper Interconnection Cable: Supply and laying of 1 Core × 25 sq.mm Copper Cable/Wire for necessary interconnection, including all required accessories. e. Sensing Cable: Supply and laying of 4 Core × 2.5 sq.mm Copper Sensing/Control Cable, including necessary laying and termination accessories. f. Exhaust System: Supply, installation and commissioning of 3.5-inch dia exhaust piping with suitable silencer, including required bends, supports, flanges and accessories. Exhaust pipe and silencer to be provided with suitable thermal insulation/cladding. g. Earthing: Providing and installation of ISI-marked 40 mm dia GI Earthing Pipe, including GI funnel with mesh, watering arrangement and all necessary accessories, with electrode installed to a depth of approximately 6 feet, including suitable earthing compound such as salt and charcoal or approved equivalent, complete. h. Copper Earthing Strip: Supply and laying of 25 mm × 3 mm Copper Flat for DG earthing/interconnection, including necessary clamps, bolts and accessories. i. Unloading: Unloading and positioning of DG set. j. Testing & Commissioning: Complete testing, commissioning and trial run of the DG set and associated electrical works, including necessary connections and adjustments, to ensure proper and satisfactory operation. The above scope shall include all necessary materials,accessories, labour, transportation, erection, testing and commissioning required for the complete and satisfactory functioning of the DG installation. | 1 | Nos | 13,54,339 ₹13,54,339 Lowest |
| 2.00 | GST @18% | 1 | units | 2,43,781.02 ₹2,43,781.02 Lowest |
Tender Value
₹17.2 L
EMD Value
₹17,340
Closing Date
15 Sept 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer,WRD.,GWD Chennai
O/o The Executive Engineer,WRD.,Ground Water Division,Tharamani,Chennai-113
Replacement of 25kva generator by 82.50KVA Generator including all accessories etc for switch room no 1 at Panangattucherry village for watersupply to IGCAR at kalpakkam
2026_WRD_698960_1
05/GWD/CHN/2026-27
Open Tender
Maintenance Goods
Lump-sum
60 days
panangattucherry
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹17,340
16 Sept 2026
28 Aug 2026
16 Sept 2026
28 Aug 2026
15 Sept 2026
28 Aug 2026
28 Aug 2026 - 15 Sept 2026
90 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.1 | Supply, Erection, Testing and Commissioning of 82.5 kVA, 3-Phase, 415 V, 50 Hz, CPCB IV+compliant Diesel Generator Set, complete with acoustic enclosure, suitable diesel engine and alternator, Inbuilt AMF (Automatic Mains Failure) logic control panel, Inbuilt Remote Monitoring system, automatic battery charging facility and all standard accessories, including necessary cabling, connections, installation, testing and commissioning, complete in all respects as per applicable standards and manufacturer’s recommendations. a. Power Cable: Supply and laying of 3.5 Core × 120 sq.mm, ISI-marked Aluminium XLPE insulated, PVC sheathed power cable, including suitable cable routing, laying accessories and cable end termination with suitable glands, lugs and accessories at both ends. b. Main Switch: Supply and fixing of 100 A, suitable-rated Main Switch, complete with enclosure and necessary accessories. c. Changeover Switch: Supply and fixing of 125 A, 4-Pole Changeover Switch, suitable for DG/Mains changeover, complete with enclosure and accessories. d. Copper Interconnection Cable: Supply and laying of 1 Core × 25 sq.mm Copper Cable/Wire for necessary interconnection, including all required accessories. e. Sensing Cable: Supply and laying of 4 Core × 2.5 sq.mm Copper Sensing/Control Cable, including necessary laying and termination accessories. f. Exhaust System: Supply, installation and commissioning of 3.5-inch dia exhaust piping with suitable silencer, including required bends, supports, flanges and accessories. Exhaust pipe and silencer to be provided with suitable thermal insulation/cladding. g. Earthing: Providing and installation of ISI-marked 40 mm dia GI Earthing Pipe, including GI funnel with mesh, watering arrangement and all necessary accessories, with electrode installed to a depth of approximately 6 feet, including suitable earthing compound such as salt and charcoal or approved equivalent, complete. h. Copper Earthing Strip: Supply and laying of 25 mm × 3 mm Copper Flat for DG earthing/interconnection, including necessary clamps, bolts and accessories. i. Unloading: Unloading and positioning of DG set. j. Testing & Commissioning: Complete testing, commissioning and trial run of the DG set and associated electrical works, including necessary connections and adjustments, to ensure proper and satisfactory operation. The above scope shall include all necessary materials,accessories, labour, transportation, erection, testing and commissioning required for the complete and satisfactory functioning of the DG installation. | - | Nos | - | - |
| 2GST @18% | |||||
stage.html
html • 0.02 MB
finance_840296.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
TD.pdf
Tender Documents • 0.94 MB
BOQ_840296.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .