Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC MISRA ELECTROSTATE CENTRE BAR ASSOCIATION COMPOUND CIVIL COURT AYODHYA 224123 UP | AYODHYA | AYODHYA | UTTAR PRADESH | 224123 | L1 | Accepted-AOC tenderaccepted | |
| 2 | L2₹13.5 L+₹96,671 (7.68%)Rejected-Finance | L2 | Rejected-Finance not being L1 | |
| 3 | L3₹14.6 L+₹2.0 L (16.0%)Rejected-Finance | L3 | Rejected-Finance not being L1 | |
| 4 | L4₹14.9 L+₹2.4 L (18.8%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L4 | Rejected-Finance not being L1 | |
| 5 | L5₹1.8 Cr+₹1.7 Cr (1341.3%)Rejected-Finance | L5 | Rejected-Finance not being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
21 Jan 2020, 6:00 pmClosed
GE faizabad
GE MES Faizabad
Repair Maintenance of Power Factor Correction Panels Capacitor Banks Lightning conductors and connected works at Faizabad
2019_MES_307317_1
8936/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Faizabad
As per tender documents
7 documents required · 7 mandatory
₹500
GE faizabad
₹40,000
Yes
19 Feb 2020
18 Dec 2019
22 Jan 2020
18 Dec 2019
21 Jan 2020
1 Jan 2020
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/ loose of soil complete all as specified.
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soft/ loose soil complete all as specified.
M & L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured & Paid separetly).
Supply & Laying of sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in trenches for protection of U/G cable complete all as specified and directed by Engr-in-Charge.
Taking out U/S LT UG cable of any size from trenches , ducts etc all as directed by Engr-In-Charge. Note:- Excavation and earth work shall be measured paid separately under respective item.
Supplying, laying, commissioning & testing LT underground cable 16 Sqmm 4 Core, 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes including taking out old unserviceable cables, protection pipes/bricks or precast concrete cable covers, etc. complete all as specified and directed by Engr-in-Charge. Note :- The excavation and earth work shall be measured and paid for separatly.
All as per item no. 7 above but 25 sqmm 3.5 core
All as per item no. 7 above but 70 sqmm 3.5 core
All as per item no. 7 above but 120 sqmm 3.5 core
All as per item no. 7 above but 185 sqmm 3.5 core
Material and labour for control relay MXO 4OE (4 NO) (Auxilary Contactor) for automatic power factor correction panel. Make: L&T, Cat No:CS94018 or equivalent in Schneider/ Seimens/Legrands as approved including taking out of old one all as specified and as directed.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 25 kVAR three phase suitable for 440 volt AC 50 Hz supply, make: L&T, Type: LTCCU or equivalent in Neptune/ Schneider as approved including taking out of old one all as specified and as directed.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 10 kVAR three phase suitable for 440 volt AC 50 Hz supply, make: L&T, Type: LTCCU or equivalent in Neptune/ Schneider including taking out of old one all as specified and as directed.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 5 kVAR three phase suitable for 440 volt AC 50 Hz supply, make: L&T, Type: LTCCU or equivalent in Neptune/ Schneider including taking out of old one all as specified and as directed.
Material and labour for LED phase Indicator lamp Red/Yellow 16 mm panel mounting type, make: L&T, Cat No. SIL or equivalent as approved including taking out of old one all as specified and as directed.
Material and labour for LED phase Indicator lamp Blue 16 mm panel mounting type, make: L&T, Cat No. SIL or equivalent as approved including taking out of old one all as specified and as directed.
Material and labour for Push Button Red/ Green panel mounting type, make: L&T, Cat No. HD 15C or equivalent in ABB/Schneider/Seimens/Legrands including taking out of old one all as specified and as directed.
S & F MCB 415 V, triple pole, 63 Amps, 'C' curve, 10 kA of make: L&T, Cat No. BB30630C or equivalent in ABB/Schneider/Seimens/Legrands including taking out of old one all as specified and as directed.
S & F MCB 415 V, triple pole, 32 Amps, 'C' curve, 10 kA of make: L&T, Cat No. BB30320C or equivalent in ABB/Schneider/Seimens/Legrands including taking out of old one all as specified and as directed.
S & F MCB 415 V, triple pole, 16 Amps, 'C' curve, 10 kA of make: L&T, Cat No. BB30160C or equivalent in ABB/Schneider/Seimens/Legrands including taking out of old one all as specified and as directed.
Supply & fix in replacement of MCCB, 4 pole, 125 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, conforming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. Make :- L&T Cat No.CM90642OOLO or equivalent in Legrands / Schneider as approved.
Supply & fix in replacement of MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA,lcu=100%, conforming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. Make :- L&T Cat No.CM90642OONO or equivalent in Legrands / Schneider as approved.
Supply & fix in replacement of MCCB, 4 pole, 200 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, conforming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. Make :- L&T Cat No.CM90642OONO or equivalent in Legrands/ Schneider.
Supply & fix in replacement of MCCB, 4 pole, 250 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, conforming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T Cat No.CM90642OOPO or equivalent in Legrands / Schneider.
Supply & fix in replacement of MCCB, 4 pole, 500 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA,lcu=100%, conforming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge. (Make :- L&T Cat No.CM94106OOS1OG. or equivalent in Legrands/ Schneider.
S & F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 30 kVAR. Make: L&T, Cat No - CS96148 or equivalent in ABB/Schneider/Seimens/Legrands including taking out of old one all as specified and as directed.
S & F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 12.5 kVAR. Make: L&T, Cat No - CS96321 or equivalent in Schneider/ Seimens including taking out of old one all as specified and as directed.
S & F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 8.5 kVAR. Make: L&T, Cat No - CS96320 or equivalent in Schneider/ Seimens including taking out of old one all as specified and as directed.
S & F three phase digital Voltmeter with LED display, accuracy class 1.0, voltage measurement range between phase to phase 50-550 volt AC flush mounting type of size 96 x 96 mm of make: L&T, Cat No - WL132010OOOO or equivalent ISI marked as approved including taking out of old one all as specified and as directed
S & F three phase digital Ammeter with LED display, accuracy class 1.0, AC flush mounting type of size 96 x 96 mm of make: L&T, Cat No - WL1010OOOO or equivalent ISI marked as approved including taking out of old one all as specified and as directed.
S & F Current Transformer tape wound ring of capacity 200/5 Amp, burden 15 VA, precision class 1% including taking out of old one all as specified and as directed. Make- L&T/ Kappa / Matrix or equivalent ISI marked.
S & F Current Transformer tape wound ring of capacity 400/5 Amp, burden 15 VA, precision class 1% including taking out of old one all as specified and as directed. Make- L&T/Kappa/Matrix equivalent ISI marked.
S & F Current Transformer tape wound ring of capacity 500/5 Amp, burden 15 VA, precision class 1% including taking out of old one all as specified and as directed. (Make- Kappa/ L&T/Matrix equivalent ISI marked.).
S & F APFC replay of step (5 +1*) of size 96 x 96 (3 Step APFC controller + 3 step plug-in-module) all as specified and as directed. (Make- L&T, Cat No - ETACONM003R+ETACONEXP3R or equivalent in Schneider/Seimens).
S & F APFC replay of step (7 +1*) of size 96 x 96 (5 Step APFC controller + 3 step plug-in-module) all as specified and as directed. (Make- L&T, Cat No - ETACONM003R+ETACONEXP23R or equivalent in Schneider/Seimens as approved).
S & F APFC replay of step (13 +1*) of size 144 x144 (8 Step APFC controller + 3 step plug-in-module + 3 step plug-in-module) all as specified and as directed. (Make- L&T, Cat No - ETACONM008R+ETACONEXP23R+ETACONEXP3R or equivalent in Schneider/Simens as approved).
S & F multi step switch with OFF of capacity 1 phase 3 Watt, 6 Amp all as specified and as directed. (Make- L&T/ Schneider/ Legrands).
Khan Brothers
M/S AVADH ENTERPRISES
Unnati Engineers
sethi tradres
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .