Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.3 LAccepted-AOC NO 4 SRIRAMULU VILLA MULLAI STREET KANDAN NAGAR TIRUTTANI 631209 | TIRUTTANI | THIRUVALLUR | TAMIL NADU | 631209 | L1 | Accepted-AOC LOWEST QUOTED HENCE ADMITTED | |
| 2 | L2₹69.3 L+₹5.0 L (7.82%)Rejected-AOC 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L2 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 3 | L3₹72.2 L+₹8.0 L (12.4%)Rejected-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L3 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 4 | L4₹73.6 L+₹9.4 L (14.5%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED | |
| 5 | L5₹78.2 L+₹13.9 L (21.7%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST QUOTED HENCE NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
9 Apr 2024, 6:00 pmClosed
COL MANOJ NEGI
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
SPECIAL REPAIRS/CONVERSION OF LT OH LINE TO XLPE UG CABLE AND ALLIED WORKS OF ALL MESSES AND BILLETS IN DOMESTIC AREA AT AFS TAMBARAM
2024_MES_643073_1
87639CWEAFNTBM
Open Tender
Civil Works
Item Rate
180 days
GE (AF) TAMBARAM
AS PER NIT
6 documents required · 6 mandatory
₹1,000
GE (AF) TAMBARAM
₹1.6 L
Yes
3 Jun 2024
19 Feb 2024
16 Apr 2024
19 Feb 2024
9 Apr 2024
2 Apr 2024
20 Feb 2024 - 1 Mar 2024
Amount
M & L for excavation in trenches not exceeding 1.5 mtr depth and not exceeding 1.5 mtr width and getting out in hard/ dense soil complete all as specified and directed.
M & L for returning and refilling of excavated soil upto a depth of 30 cm and riddled excavated soil for cable protection for laying under ground cable all as specified and as directed. Note : Cable protection with riddled earth is deemed included in the item.
M & L for removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable all as specified and directed.
Dismantling cross arms of MS channel or angle iron section etc complete all as specified and directed.
Dismantling of insulators of any type and size complete all as specified and directed.
Dismantling old and unserviceable ACSR conductor of any size including disconnecting from the poles and depositing where directed complete all as specified and directed.
M&L for PCC 1:3:6, type C-1, (using 20 mm graded stone aggregate) as in foundation/ road cutting etc and finishing the exposed concrete surfaces even and fair all as specified and as directed.
M&L Straight through joints heat shrinkable joint kits suitable for 3.5/4 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits and labour complete for making joints all as specified and as directed for following : - 3.50/4 core cable 25 to 50 Sq mm.
All as per item No. 09 but 3.50/4 core cable 70-120 Sq mm
All as per item No. 09 but 3.50/4 core cable 240-300 Sq mm
M & L for cutting chases on concrete surfaces for concealing GI tubing/HDPE pipe exceeding 10 cm but not exceeding 20 cm girth ,making good to facing where required and pointing in cement mortar 1:3 complete all as specified and directed.
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with stranded aluminium conductor of 16 sqmm 2 core complete including lugs/thimble/ferules connection, testing and commissioning complete all as specified and as directed.
All as per item No.13 above, but of size 16 sqmm 4 core
All as per item No.13 above, but of size 25 sqmm 3.5 core
All as per item No.13 above, but of size 35 sqmm 3.5 core
All as per item No.13 above, but of size 50 sqmm 3.50 core
All as per item No.13 above, but of size 70 sqmm 3.50 core
All as per item No.13 above, but of size 95 sqmm 3.50 core
All as per item No.13 above, but of size 120 sqmm 3.50 core
All as per item No.13 above, but of size 185 sqmm 3.50 core
All as per item No.13 above, but of size 240 sqmm 3.50 core
All as per item No.13 above, but of size 300 sqmm 3.50 core
All as per item No.13 above, but of size 400 sqmm 3.50 core
Taking out the existing any description of LT UG cable and find the fault and re-laying of the same LT UG cable 1100 Volts grade PVC insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/ thimble/ ferules connection, testing and commissioning complete all as specified and directed. Note: [i] Earth work, excavation sand cushioning, bricks for protection, GI pipe, LT UG Cable Joints etc shall be measured separately under relevant items of this schedule . [ii] If old LT UG cable is found unserviceable, LT U/G cable shall be measured and paid as Supply and Laying of LT UG cable under relevant items of this schedule. 10 sqmm to 16 sqmm 2/4 core
All as per item No. 25 but16 sqmm to 35 sqmm 3.5 core
All as per item No. 25 but 50 sqmm to 120 sqmm 3.5 core
All as per item No. 25 but 150 sqmm to 240 sqmm 3.5 core
S & F of GI tubing 'Light' grade with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area all as specified and directed for following sizes of pipes :- 40 mm Bore
All as per item No. 29 but 50 mm Bore
All as per item No. 29 but 80 mm bore
All as per item No. 29 but 100 mm bore
M&L for 20 mm dia PVC conduit and accessories fixed to walls, poles etc for cable protection complete all as specified and directed.
S&F PVC junction box out door type of size 280 mm x 170 mm x 130 mm with front openable hinged cover complete with two number aluminium bus bars mounted on porcelain insulator including clamps of MS flat iron 25 x 3 mm with bolts and nuts to fixed on pole/wall incl taking down of old U/S all as specified and directed. (Make: SINTEX or equivalent)
S&F 3 core cable PVC insulated copper conductor, 1100 Volts grade, 2.5 Sqmm size of ISI marked complete all as specified and directed.
M & L for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 32x6 mm GI strip means of bolts, nuts, washers of galvanized iron all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 140mm centre to centre with suitable handle, 40mm dia light grade GI pipe for protection of GI strip and watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion. Note : GI Strip upto 7.5m is deemed included in the i tem.
M & L for boring of holes under road,pavement and hard standing by trenchless techonology using ultra sound technique and necessary machine including HDPE pipe of 110 mm dia suitable for o.4 mpa working pressure complete all as specified and directed.
rc enterprises
EVEREST ENGINEERING WORKS
Global Safety Engineering and Management Solutions
SJM CONSTRUCTIONS
DANUSH INTERIORS AND CONTRACTORS
SRI LAKSHMI ASSOCIATES
prabhakaran
OM ENTERPRISES
Roy and Sons Infrastructers
ragavbuilders
Shiva Shakthi Electrical Enterprises
lakshmibuilders
RRK PROJECTS
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .