Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.6 LAccepted-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC AOC | |
| 2 | L2₹54.5 L+₹3.3 L (6.52%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹55.3 L+₹4.2 L (8.16%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹55.5 L+₹4.4 L (8.54%)Rejected-Finance FLAT NO 1 PLOT NO 54 GRD FLOOR TULSI ASTHA NEAR SHRI ANAND RUSHIUDYAN SECTOR 12 VASHI NAVI MUMBAI 400 703 | THANE | MAHARASHTRA | 400703 | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹59.5 L+₹8.3 L (16.3%)Rejected-Finance | L5 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | M/s Shree Construction Co L3 | M/s Shreeji Construction Co L4 | HINDUSTAN BUILDERS L2 | Parmatma Enterprises L1 | A G ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | SCH 'A' PART-I "BLDG WORK " Total of Schedule 'A' Part-II brought forwarded from Serial Page No. 158 | 1 | LUMP SUM | 34,75,450 ₹34,75,450 | 33,02,500 ₹33,02,500 | 35,84,375 ₹35,84,375 | 25,25,000 ₹25,25,000 Lowest | 36,00,000 ₹36,00,000 |
| 2.00 | SCH 'A' PART-II : SITE CLEARANCE" Total of Schedule 'A' Part-I brought forwarded from Serial Page No. 159 | 1 | LUMP SUM | 12,300 ₹12,300 Lowest | 14,090 ₹14,090 | 23,391 ₹23,391 | 20,000 ₹20,000 | 17,500 ₹17,500 |
| 3.00 | SCH 'A' PART-III "INTERNAL WATER SUPPLY" Total of Schedule 'A' Part-III brought forwarded from Serial Page No. 161 | 1 | LUMP SUM | 10,500 ₹10,500 Lowest | 15,400 ₹15,400 | 19,545 ₹19,545 | 16,000 ₹16,000 | 14,100 ₹14,100 |
| 4.00 | SCH 'A' PART-IV "INTERNAL ELECTRIFICATION" Total of Schedule 'A' Part-IV brought forwarded from Serial Page No. 165 | 1 | LUMP SUM | 1,13,500 ₹1,13,500 Lowest | 1,16,200 ₹1,16,200 | 1,84,900 ₹1,84,900 | 1,30,000 ₹1,30,000 | 1,22,300 ₹1,22,300 |
| 5.00 | SCH 'A' PART-V "EXTERNAL WATER SUPPLY" Total of Schedule 'A' Part-V brought forwarded from Serial Page No. 166 | 1 | LUMP SUM | 75,650 ₹75,650 Lowest | 80,200 ₹80,200 | 1,22,694 ₹1,22,694 | 86,000 ₹86,000 | 83,200 ₹83,200 |
| 6.00 | SCH 'A' PART-VI "EXTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-VI brought forwarded from Serial Page No. 169 | 1 | LUMP SUM | 4,25,400 ₹4,25,400 | 4,48,420 ₹4,48,420 | 7,04,851 ₹7,04,851 | 56,000 ₹56,000 Lowest | 4,62,700 ₹4,62,700 |
| 7.00 | SCH 'A' PART-VII "LIGHTING ARRESTOR" Total of Schedule 'A' Part-VII brought forwarded from Serial Page No. 170 | 1 | LUMP SUM | 65,800 ₹65,800 | 55,200 ₹55,200 | 67,281 ₹67,281 | 50,000 ₹50,000 Lowest | 60,100 ₹60,100 |
| 8.00 | SCH 'A' PART-VIII "SEWAGE DISPOSAL" Total of Schedule 'A' Part-VIII brought forwarded from Serial Page No. 172 | 1 | LUMP SUM | 98,500 ₹98,500 Lowest | 99,500 ₹99,500 | 1,58,353 ₹1,58,353 | 1,08,500 ₹1,08,500 | 1,08,200 ₹1,08,200 |
| 9.00 | SCH 'A' PART-IX "AREA DRAINAGE" Total of Schedule 'A' Part-IX brought forwarded from Serial Page No. 173 | 1 | LUMP SUM | 60,950 ₹60,950 | 60,200 ₹60,200 Lowest | 98,616 ₹98,616 | 70,000 ₹70,000 | 65,920 ₹65,920 |
| 10.00SCH 'A' PART-X "PROVN OF FIRE HYDRANT AT NAD (T) | ||||||||
Tender Value
Refer Docs
EMD Value
₹99,980
Closing Date
17 Sept 2025, 6:00 pmClosed
GE NW Mankhurd
GE (NW) MNAKHURD MUMBAI-88
PROVN OF ONE FULLY INTEGRATED SECURITY WATCH TOWER, CONTROL ROOM AT 464 DUS MD ACCN AT MANKHURD AND PROVN OF ADDL FIRE HYDRANT POST, VALVES AND EXTN OF MAIN FIRE LINE AT NAD AND PROVN OF FLAME PROOF PEDESTAL FANS AT NAD UNDER GE (NW) MNAKHURD
2025_MES_718851_2
8441/E8
Open Tender
Civil Works
Lump-sum
180 days
GE NW Mankhurd
As per Tender Documents
9 documents required · 9 mandatory
₹500
GE (NW) MNAKHURD
₹99,980
13 Oct 2025
21 Aug 2025
19 Sept 2025
21 Aug 2025
17 Sept 2025
3 Sept 2025
Amount
SCH 'A' PART-I "BLDG WORK " Total of Schedule 'A' Part-II brought forwarded from Serial Page No. 158
SCH 'A' PART-II : SITE CLEARANCE" Total of Schedule 'A' Part-I brought forwarded from Serial Page No. 159
SCH 'A' PART-III "INTERNAL WATER SUPPLY" Total of Schedule 'A' Part-III brought forwarded from Serial Page No. 161
SCH 'A' PART-IV "INTERNAL ELECTRIFICATION" Total of Schedule 'A' Part-IV brought forwarded from Serial Page No. 165
SCH 'A' PART-V "EXTERNAL WATER SUPPLY" Total of Schedule 'A' Part-V brought forwarded from Serial Page No. 166
SCH 'A' PART-VI "EXTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-VI brought forwarded from Serial Page No. 169
SCH 'A' PART-VII "LIGHTING ARRESTOR" Total of Schedule 'A' Part-VII brought forwarded from Serial Page No. 170
SCH 'A' PART-VIII "SEWAGE DISPOSAL" Total of Schedule 'A' Part-VIII brought forwarded from Serial Page No. 172
SCH 'A' PART-IX "AREA DRAINAGE" Total of Schedule 'A' Part-IX brought forwarded from Serial Page No. 173
SCH 'A' PART-X "PROVN OF FIRE HYDRANT AT NAD (T)
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and not exceeding 10 sqm on plan and getting out in soft/loose soil for laying of cables, ERW pipes etc. complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm deep as in hard/soft soil complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point in soil including spreading in low lying area and leveling complete all as specified and as directed.
M&L for cutting existing road/hard standing not exceed 45x60 cm in wide and depth getting out excavated material for laying of cable returning filling & well ramming watering finish surface 10 cm from top including provision of PCC 1:2:4 for repairing, including removal of surplase soil all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for reinforced cement concrete nominal mix M-20 (using 20 mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column, pipe support base etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately).
Material and labour for fire points made out from MS angle iron 40x40x6 cutting welding etc including rain protection canopy made out of 2mm thick CRCA sheet, painting with two coat of red post office colour all as directed for keeping various accessories
Supply and Fix in repair for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over and including 25 mm thick sand cushion complete all as specified and as directed.
M&L for taking out old ERW pipes by excavating from trenches and cutting corroded or wornout portion for repairs and refixing after carryout repairs welding/jointing and relaying in trenches after repairs including applying a coat of red oxide and the coat of post after red colour paint complete all as trenches for the 100 mm size of pipes all as specified and directed by Engr-in-charge. Note:- Excavation and earth work shall be measured & priced specifically under appropriate rate.
Supplying, fixing, jointing and testing, ISI marked heavy grade, Class C, MS ERW pipe of 100 mm conforming to IS: 1239-1982, including fittings such as coupling, bends, elbow and tee screwed/flanged joints, nuts & bolts, rubber packing rings,fixed on wall, hanged with ceiling through clamps, hangers, brackets, pipe supports, U bolts on MS brackets with anchor fasteners all as directed and appliying 2 coats of synthetic enamel paint over a coat of zinc dichromate primer, etc as per the site requirement in long/short pieces all as specified and directed by Engr-in-charge. Make :- Tata/ Jindal / BST/ Oswal Note: Underground pipelines are protected from corrosion and environmental factors as per IS 10221:2008 for coating and wrapping procedures and using coal tar-based anticorrosion tapes as per IS 15337:2003. The cost of pipeline wrapping is included in the quoted rate
Supplying, fixing, jointing and testing, ISI marked heavy grade, Class C, MS ERW pipe of 80 mm conforming to IS: 1239-1982, including fittings such as coupling, bends, elbow and tee screwed/flanged joints, nuts & bolts, rubber packing rings,fixed on wall, hanged with ceiling through clamps, hangers, brackets, pipe supports, U bolts on MS brackets with anchor fasteners all as directed and appliying 2 coats of synthetic enamel paint over a coat of zinc dichromate primer, etc as per the site requirement in long/short pieces all as specified and directed by Engr-in-charge. Make :- Tata/ Jindal / BST/ Oswal Note: Underground pipelines are protected from corrosion and environmental factors as per IS 10221:2008 for coating and wrapping procedures and using coal tar-based anticorrosion tapes as per IS 15337:2003. The cost of pipeline wrapping is included in the quoted rate
S&F for fabricate supply and fix MS flat clamps made out MSFI of size 40 x 6 mm (confirming to Fe 290 Gde-165 ) including drilling hole, nut, bolts, washer and made to shape of required size ie. for 100 mm dia / 80 mm dia MS pipe all specified and as directed by Engr- in - Charge.
Supply and fix flanged yard hydrant/Stand post of 80 mm dia MS with double end flanged type 1.5 m height all specified and as directed by Engr- in - Charge. Make :- Best available in the market
Supply and fixing, Gun Metal, single outlet type fire hydrant landing valve, type B (Double head outlet) ISI marked of size 63mm dia complete with brass spindle cast iron wheel, with rubber gasket, nut,bolt etc and instantaneous coupling ISI marked, confirming to IS 5290 hydrostatic test pressure 23 kg/cm2, minimum operating pressure 7kg/cm2. Make:- NewAge / Essel / Swati
Supply and fix 63 mm dia 15 meter long Controlled Percolating (CP) Fire hose with jacket 100% synthetic yarn fabric reinforced conforming to IS 8423:1994 complete with male and female coupling conforming to IS 903 complete all as directed by Engr-in-charge. Make:- NewAge / Essel / Swati / Safex
Supply and fixing standard short size gun metal branch pipe with gun metal nozzle 16 mm dia outlet with standard male instantaneous spring lock type 63 mm dia coupling. Branch pipe and nozzle shall confirm to IS : 903-1985 as per existing make all as directed by Engineer-in-Charge.
Supply, fixing, fire hose cabinet box of size as per requirement but not less than 800X600X250 mm, out door type Made out from 18 Gauge MS sheet duly painted with 2 coats of red colour synthetic enamel paint over a coat of redoxide primer with double leafed glazed shutters (Glaged with 4mm thick glass) suitable for housing of 2 length of canvas hose, branch pipe, fire hose and nozzle, fire man axe, first aid hose and single outlet landing valve,including free standing stand made of of MS angle of size 40 mm X 40mm X 5 mm and including pcc foundation of required size but not less than 0.45 mtr height above ground levelincluding dismantling old cabinet hose box complete all as directed. Make :- Vijay / Winco / Ceasefire / New Age
S&F sluice valve 80 mm bore, cast iron body, flanged drilled end, conforming to IS-14846, ISI marked, class PN 1.6, reselient seating as well as metal seating Fusion bonded epoxy coating including all joints with rubber gaskets, bolts and nuts, washers, iron wheel including taking up / down old unserviceable valves from any position and any addition / alteration for fixing required complete all as specified and as directed. Make :- Kirloskar / Leader / Kartar / Upadhyay
S&F sluice valve 100 mm bore, cast iron body, flanged drilled end, conforming to IS-14846, ISI marked, class PN 1.6, reselient seating as well as metal seating Fusion bonded epoxy coating including all joints with rubber gaskets, bolts and nuts, washers, iron wheel including taking up / down old unserviceable valves from any position and any addition / alteration for fixing required complete all as specified and as directed. Make :- Kirloskar / Leader / Kartar / Upadhyay
S&F sluice valve 200 mm bore, cast iron body, flanged drilled end, conforming to IS-14846, ISI marked, class PN 1.6, reselient seating as well as metal seating Fusion bonded epoxy coating including all joints with rubber gaskets, bolts and nuts, washers, iron wheel including taking up / down old unserviceable valves from any position and any addition / alteration for fixing required complete all as specified and as directed. Make :- Kirloskar / Leader / Kartar / Upadhyay
M&L for renewal of valve pit of size up to 80 cm x 80 cm x 80 cm (internal diamension), stone / brick construction including all necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, PCC in foundation for mix (1:2:4) type D2 brick mansonary in cement mortar (1:4) rendering 12 mm duck in cement mortar (1:4) internally ,finished even and fair and polishing flush externally as the work proceeds in the same mortor. Mild steel angle iron 40 x 40 x 6 mm frame MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all exposed MS work with two coats of synthetic enamel paint of the that as approved by the Engineer - in - charge over a coat of red oxide primer and painting all the MS embeded in PCC with two coats of black bitumenous paint complete all as specified.
Supply, design, fabrication, and installation of an illuminated schematic layout signboard of size 1.5 meters x 1.5 meters, made of high-quality PVC acrylic sheet, complete with LED backlighting. The signboard shall display a schematic layout of the Fire Main Line System and Fresh Water Line System at NAD, Tanaji, Mankhurd, and WED Pump Station/Fire Station, including ERW/GI/CI/DI pipes, control valves, and associated components, with provisions for hanging at the specified locations. Note: Each location will have its own schematic diagram based on its needs.The contractor shall be responsible for the following: 1. Trace existing ERW, GI, CI, and DI lines, including control valves and associated systems of respective area to prepare an accurate layout diagram. 2. Submit the traced layout as a draft for approval by the Engineer-in-Charge before fabrication. 3. Fabricate the signboard using a durable PVC acrylic sheet, suitable for both indoor and outdoor use. 4. Ensure the diagram is printed with high-definition graphics and labels for clarity and long-term readability. 5. Incorporate LED backlighting or other suitable illumination for visibility during day and night. 6. Provide all necessary mounting arrangements for securely hanging the board at the designated locations. 7. Submit a traceable or CAD-format version of the schematic diagram along with the final installed board for reference. 8. A one-year warranty covering defects in material, workmanship, and illumination performance.
M & L for preparation of old painted / unpainted surfaces of any description, including taking out of parts / components under painting from any position / location as listed under GE (NW) Mankhurd and applying one coat of epoxy paint (with colour code maintained as per relevant IS) including marking with flow directions (of approved colour) complete all as specified and as directed by Engineer-In-Charge for the following sizes of sluice valves. Make : Asian / Berger / Apex / Nerolac (a) Sluice valve of 100 mm size complete
(b) Sluice valve of 150 mm size complete
(c) Sluice valve of 200 mm size complete
Material and labour for preparing old painted steel pipe surface such as Rising pipe (Red), Delivery pipe (Blue), Overflow washout pipe (Yellow) , fire hydrant stand post , Fire ERW pipes and any exposed pipe etc and applying one coat of synthetic enamel paint for any bore GI pipe complete all as specified and as directed. Make : Asian / Berger / Apex / Nerolac Note:- (i)The arrangement of necessary equipment, such as ladders, scaffolding, or cranes, for accessing and working on pipes, shall be managed and provided by the contractor, and the cost of such arrangements is included in the quoted rate. (ii) Deteriorated paint layers are removed manually or mechanically using wire brushes, scrapers, or sandpaper. The surface is then thoroughly cleaned to eliminate dust, grease, rust, and contaminants, ensuring an even, bare metal or sound substrate suitable for painting.
SCH 'A' PART-XI " PROVN OF FLAME PROOF PEDESTAL FANS AT NAD (T)"
Supply & Fix flame proof Pedestal Fan 600mm sweep, operating on single phase, 230V, AC 50 Hz having speed of 1440 RPM, air delivery 270 CMM, power output of 180W star rated along with blade, canopy, mounting brackets, rubber insulator, flame proof accessories. Make - Shyam/Sudhir or equivalent
HINDUSTAN BUILDERS (BID ID -3421856)
M/s Shree Construction Co (BID ID -3419068)
M/s Shreeji Construction Co (BID ID -3421496)
A G ENTERPRISES (BID ID -3421817)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .