Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance C O ALI MOHAMMAD BABA SONS ALBA TOWER SRINAGAR HARI SINGH HIGH STREET SRINAGAR JAMMU KASHMIR 190002 | SRINAGAR | JAMMU AND KASHMIR | 190002 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 234 BBN ENERGY SYSTEMS PRIVATE LIMITED 234 SECTOR 37 PHASE VI UDYOG VIHAR GURGAON GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance GROUND FLOOR ASHFAQ HUSSAIN AL ABASS A S RELIEF TRUST BUILDING KARAN NAGAR SRINAGAR 91495 SRINAGAR JAMMU AND KASHMIR 190010 | SRINAGAR | JAMMU AND KASHMIR | 190010 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹1.8 Cr
Closing Date
10 Nov 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Electric Division Sgr.
Barbarshah Maisuma Srinagar
Design, Fabrication, Assembly, Wiring, Supply and Installation of front Operated Cubical Type L T Panels for 500 Bedded Pediatric Hospital at Bemina Srinagar.
2021_PWDJK_145099_1
E/NIT/154/2021/22dtd27/10/2021
Open Tender
Electrical Works
Item Rate
45 days
Design, Fabrication, Assembly, Wiring, Supply and
as per BOQ
7 documents required · 7 mandatory
₹2,600
Executive Engineer RNB Electric Division Sgr.
Exempted
10 Nov 2021
27 Oct 2021
10 Nov 2021
27 Oct 2021
10 Nov 2021
27 Oct 2021
120 days
Amount
Design, Fabrication, Assembly, wiring, supply of front operated cubical type compartmentalized as per form 4, rear access free standing dust and vermin proof with ingress protection IP 42 for indoor & IP 54 for outdoor application for main switchboards suitable for use at 415 volts, 3 Phase 4 Wire 50 Hz system suitable for fault level of required value symmetrical at 415 Volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketed ( metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat section including 3 mm thick gland plated on top and bottom and fitted with lifting hooks, Galvanized hardware's with zinc passivation shall be used in fabrication of panels and including Gi strip of required size with 2 no earthing and including powder coated paint finish of approved shade over metal surface cleaned complete with interconnections etc. as per relevant IS as detailed below. Approval shall be taken for each panel in the form of shop drawings before fabrication.
The CT burden shall be minimum 15VA or more as required
The switch board shall have provision for entry of all PVC cables / bus duct from the top / bottom as required.
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The Busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and Busbar support shall be used. Padlocking facility shall be provided on all outgoing feeder doors and switch handles shall be lockable in OFF position.
All ka rating shall be ICS values.
The cost shall include providing and fixing of 100x50x6 mm channels for switchboard support.
Short Circuit capacity for MCCB`s shall be Icu values and Icu values shall not be less than 100% Icu
All incoming Bus Sections and out going feeders shall have fault trip auxiliary contacts for wiring to annunciation fault indication panel.
Valid Type test certificates from independent testing lab for short circuit and fault with stand for 1 sec.
All ACB ratings in panel capacities at 45'C ambient temperature.
All MCCB shall be provided with Motor wound spring closing mechanism with 2 no spare NO/NC contact in main panels.
All ACB shall be EDO with 2 no spare NO/NC contact in main panels.
(Synchronizing Panel) (For Details Refer SLD)
INCOMER
1 No ACB 1250 Amps 4 P with Breaking Capacity 50 KA(Icu=Ics=Icw=100%)
2 No ACB 1000 Amps 4 P with Breaking Capacity 50 KA(Icu=Ics=Icw=100%)
1 No ACB 630 Amps 4 P with Breaking Capacity 50 KA(Icu=Ics=Icw=100%)
4 No Reverse Power Relay
4 No Multifunction Meter with RS-485 Port
4 No Battery Charger 24 Volts
Battery Charger with Battery Bank 24 Volts for Control Supply
4 Sets Indicating Lamps RYB
4 No Voltmeter-0-500 Volts
3 No Ammeter(0-1500 A)
1 No Ammeter(0-1800 A)
1 No Current Transformer 1250/5 A 10 VA Burden, Class-1
2 No Current Transformer 1000/5 A 10 VA Burden, Class-1
1 No Current Transformer 800/5 A 10 VA Burden, Class-1
1 Set Aluminum Busbar 3200 Amps FP E-91 E Grade Electrolytic Aluminum
1 No PLC,HMI
12 No S.P MCB 2A
4 Set ON/OFF/Trip
OUTGOINGS
1 No ACB 3200 Amps 4 P with Breaking Capacity 65 KA(Icu=Ics=Icw=100%)
1 No Multifunction Meter with RS-485 Port
2 No Current Transformer3000/5 A 10 VA Burden, Class-1
3 No S.P MCB 2A
1 No Voltmeter-0-500 Volts
1 Set ON/OFF/Trip
1 No Ammeter(0-4000 A)
Main LT Panel Board (For Details Refer SLD)(MLTP)
INCOMER
4 No ACB 2500 Amps 4 P with Breaking Capacity 65 KA(Icu=Ics=Icw=100%)
1 No ACB 3200 Amps 4 P with Breaking Capacity 65 KA(Icu=Ics=Icw=100%)
3 Sets Indicating Lamps RYB
3 Sets Voltmeter-0-500 Volts
2 No Ammeter(0-3000 A)
1 No Ammeter(0-4000 A)
3 Set Current Transformer 3000/5 A 10 VA Burden, Class-1
1 set Aluminum Busbar 3500 Amps FP E-91 E Grade Electrolytic Aluminum
9 No S.P MCB 2A
3 Set ON/OFF/Trip
3 No Multifunction Meter with RS-485 Port
OUTGOINGS
5 No MCCB Microprocessor Based 200 Amps F.P with Breaking Capacity 36 KA(Icu=Ics=100%) ROH
3 No ACB 1000 Amps F.P with Breaking Capacity 50 KA(Icu=Ics=Icw=100%)
3 No ACB 1600 Amps F.P with Breaking Capacity 50 KA(Icu=Ics=Icw=100%)
3 No ACB 800 Amps F.P with Breaking Capacity 50 KA(Icu=Ics=Icw=100%)
13 Sets Indicating Lamps ON OFF TRIP
Load Bearing Members to be made out of 2.0 mm CRCA Sheet.
Partitions to be made out of 1.6 mm CRCA Sheet
Gland Plates to be 3.0 mm Thick.
Capacitor Panel (For Details Refer SLD)(MLTP)
INCOMER
1 No ACB 1000 Amps 3 P with Breaking Capacity 50 KA(Icu=Ics=Icw=100%)
1 Set Indicating Lamps RYB
1 No Voltmeter-0-500 Volts
1 No Ammeter(0-1200 A)
1 Set Current Transformer 1000/5 A 10 VA Burden, Class-1
Aluminum Busbar 1200 Amps FP E-91 E Grade Electrolytic Aluminum
1 No Digital Load Manager
3 No SP MCB 2 A
1 set Indicating Lamps
1 Set On/Off/Trip
OUTGOINGS
1 No MCCB Microprocessor Based 16 Amps T.P with Breaking Capacity 36 KA(Icu=Ics=100%) with ROH
2 No MCCB Microprocessor Based 25 Amps T.P with Breaking Capacity 36 KA(Icu=Ics=100%) with ROH
3 No MCCB Microprocessor Based 50 Amps T.P with Breaking Capacity 36 KA(Icu=Ics=100%) with ROH
4 No MCCB Microprocessor Based 100 Amps T.P with Breaking Capacity 36 KA(Icu=Ics=100%) with ROH
2 No MCCB Microprocessor Based 200 Amps T.P with Breaking Capacity 36 KA(Icu=Ics=100%) with ROH
12 Set Indicating Lamps ON OFF TRIP
2 No Capacitor Duty Contactor 100 A
4 No Capacitor Duty Contactor 50 A
3 No Capacitor Duty Contactor 25 A
2 No Capacitor Duty Contactor 12.5 A
1 No Capacitor Duty Contactor 5 A
2 No Capacitor 100 KVAR H.D 440 V Gas Filled
4 No Capacitor 50 KVAR H.D 440 V Gas Filled
2 No Capacitor 10 KVAR H.D 440 V Gas Filled
3 No Capacitor 25 KVAR H.D 440 V Gas Filled
1 No Capacitor 5 KVAR H.D 440 V Gas Filled
APFCR 12 Stages
1 No Auto Manual Switch
(Utility Panel (For Details Refer SLD)
INCOMER
1 No ACB 1600 Amps 4 P with Breaking Capacity 50 KA(Icu=Ics=Icw=100%)
1 Set Indicating Lamps RYB
1 No Voltmeter-0-500 Volts
1 No Ammeter(0-2000 A)
1 No Current Transformer 1600/5 A 10 VA Burden, Class-1
1 No Aluminum Busbar 2000 Amps FP E-91 E Grade Electrolytic Aluminum
3 No S.P MCB 2A
1 set ON/OFF/Trip
1 No Multifunction Meter with RS-485 Port
OUTGOINGS
6 No 400 Amps 4 P MCCB Microprocessor Based with Breaking Capacity 36 KA(Icu=Ics=100%) and ROH
4 No 630 Amp 4 P MCCB Microprocessor Based with Breaking Capacity 36 KA(Icu=Ics=100%) and ROH
6 No 100 Amp 4 P MCCB Microprocessor Based with Breaking Capacity 36 KA(Icu=Ics=100%) and ROH
16 Set ON/OFF/Trip
UPS INPUT PANEL (For Details Refer SLD)
INCOMER 1 No ACB 800 Amps 4 P with Breaking Capacity 50 KA(Icu=Ics=Icw=100%)
1 Set Indicating Lamps RYB
1 No Voltmeter-0-500 Volts
1 No Ammeter(0-1000 A)
3 No Current Transformer 1000/5 A 10 VA Burden, Class-1
3 No S.P MCB 2A
1 No ON/OFF/Trip
OUTGOINGS
3 No MCCB Microprocessor Based 400 Amps F.P with Breaking Capacity 36 KA(Icu=Ics=100%) and ROH
3 Set ON/OFF/Trip
(UPS Output Panel) (For Details Refer SLD)
INCOMER
5 No MCCB Microprocessor Based 400 Amps F.P with Breaking Capacity 36 KA(Icu=Ics=100%) and ROH
3 sets Indicating Lamps RYB
3 No Voltmeter-0-500 Volts
3 No Ammeter(0-400 A)
3 No Multifunction Meter with RS-485 Port
3 Sets Current Transformer 400/5 A 10 VA Burden, Class-1
9 No S.P MCB 2A
3 Set ON/OFF/Trip
OUTGOINGS
1 No ACB 800 Amps 4 P with Breaking Capacity 50 KA(Icu=Ics=Icw=100%)
1 set ON/OFF/Trip
Lighting Change Over Panel
1 No Manual Changeover 800 A 4 Pole 415 V
2 sets Indicating Lamps RYB
2 No Voltmeter-0-500 Volts
2 No Ammeter(0-1000 A)
2 No Multi Function Meter
2 Set Current Transformer 800/5 A 10 VA Burden, Class-1
(Power Changeover Panel)
1 No Manual Changeover 1600 A 4 Pole 415 V
2 Set Indicating Lamps RYB
2 No Voltmeter-0-500 Volts
2 No Ammeter(0-2000 A
2 No Multi Function Meter
2 set Current Transformer 2000/5 A 10 VA Burden, Class-1
Marib Constructions
BBN ENERGY SYSTEMS PVT LTD
Simon Fabricators
stage.html
html • 0.03 MB
finance_311357.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .