Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.9 LAccepted-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹89.9 L | L1 | Accepted-AOC OK |
| 2 | L2₹91.9 L+₹2.1 L (2.29%)Rejected-Finance SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹91.9 L+₹2.1 L (2.29%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹98.6 L+₹8.8 L (9.74%)Rejected-Finance NEAR OLD POST OFFICE SUJANPUR TEH DISTT PATHANKOT PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹98.6 L+₹8.8 L (9.74%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹99.9 L+₹10.0 L (11.1%)Rejected-Finance 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹99.9 L+₹10.0 L (11.1%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹1.3 Cr+₹39.1 L (43.5%)Rejected-Finance | ₹1.3 Cr+₹39.1 L (43.5%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
8 Sept 2021, 5:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
PROVN OF 01 X ROOM FOR STATIC OXYGEN GENERATION SYSTEM ALONGWITH OXYGEN PIPING GRID OF MEDICAL GAS PIPELINE (MGPL) SYSTEM AT MILITARY HOSPITAL PATHANKOT UNDER GE (SOUTH) PATHANKOT
2021_MES_461087_1
CWE/P-05/2021-22
Open Tender
Industrial/Medical GAS
Item Rate
210 days
GE South Pathankot
class B and above and category (a) (i)
7 documents required · 7 mandatory
₹1,000
GE South Pathankot
₹2.0 L
Yes
8 Oct 2021
19 Jul 2021
10 Sept 2021
19 Jul 2021
8 Sept 2021
25 Aug 2021
Amount
Surface dressing n exc 30cm deep and avaraging 15cm deep and getting out in Hard/dense soil, complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc in Hard/dense soil and getting out, complete all as specified and directed
Returning filling in including spreading, levelling, watering and well ramming in layers n. exc 25cm thick, complete all as specified and directed.
Removal of excavated material soil n. exc 50m and depositing where directed at a level n. exc. 1.5 above the starting point, complete all as specified and directed.
M&L for hard core of gauge n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surfaces complete, complete all as specified and directed.
M&L PCC 1:4:8 type D-2 using 40mm graded agg. as in foundation filling and mass concrete, complete all as specified and directed.
M&L for brick work in cement mortar 1:4 of old size sub class ‘B' bricks straight or curved on plan exceeding 6mtr mean radius, complete all as specified and directed.
M&L for 15mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement including two coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces and curing after applying each coat, complete all as specified and directed.
M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work other than fair faces or concrete surfaces finishing the surfaces even and smooth without using extra cement includingPreparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
S&F of steel window with tubular frame factory made double shutters of size 79mm x 39mm, 16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl projecting type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete, including two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed & as shown on drg No CEPZ/ID-245/01 and 246/02 sheet ½ & 2/2.
M & L for Mild steel rolled work as in roof trusses, (framed),trussed,purlin,crane gantries,rails and heavy bracket framing (Beam,angle,channel or flat section) including distance pieces,cleats etc,confirming to grade Fe 410 -W (Gde- 250) quality A, complete all as specified and directed.
S&F glavinized mild steel wire cloths 0.56mm nominal dia and average width of aperture 1.18mm & fixed with tint tacks or glavinized wire staples, complete all as specified and directed.
S&F of welded steel fabric exc. 4.00 Kg/Sqm fixed to steel members complete complete all as specified and directed.
S&F of sheet glass 3.00 mm thick ordinary quality with glazing oil putty n exc 0.50 Sqm complete all as specified and directed.
S&F of Steel rolling shutters, with thickness of laths 1.25 mm out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, gear operated type with bevel gear box and crank handle type, complete all as specified and directed.
M&L for reinforced cement concrete nominal mix type A-1 (M-20) , 1: 1.5 :3 using 20 mm aggregate in foundations, including raft, footing, foundation beams, plinth beams, bases for columns, etc; basement slab, under rimed piles and mass concrete , complete all as specified and directed.
M&L for reinforced cement concrete nominal mix type A-1 (M-20) , 1: 1.5 :3 using 20 mm aggregate in columns,pillars, piers, posts and struts, complete all as specified and directed.
M&L for reinforced cement concrete nominal mix type A-1 (M-20) , 1: 1.5 :3 using 20 mm aggregate in chajjas, complete all as specified and directed.
M&L for reinforced cement concretenominal mix type A-1 (M-20) , 1: 1.5 :3 using 20 mm aggregate in beams, cantilevers, bressummers,lintels over 1.5 m span, complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc - Rough finished surfaces of concrete - Flat, complete all as specified and directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions - Rough finished surfaces of concrete - Square, rectangular or polygonal, complete all as specified and directed.
M&L for Formwork to sides of concrete foundation, footing, bases of columns, rafts, and raft beams, sides and soffit of foundation and plinth beams and similar works vertical to better rough finish surface of concrete, complete all as specified and directed.
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges-rough finished surfaces of concrete-flat, complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
M&L for Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
M&L for preparing the new steel surfaces of any description over 10cm width or girth priming with red oxide zinc crome and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for steel work in tublar trussed incl special shaped washers etc complete using ERW or induction butt welded tubes conferming to IS 1161-1979 gde St -240 incl purlines, complete all as specified and directed.
M & L steel work in plates (plain or chequered) channels,square cut or notched (ordinary and counter sunk) Forming holes with riveted,bolted,or welded attachments, complete all as specified and directed by eng.in.charge.
M&L Prepainted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550 Mpa as in roof covering/cladding to walls, fixed with self taping screws, complete all as specified and directed.
S&F GI tube 20mm bore medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors with all fitting, complete all as specified and directed.
S&F 15 mm Bib taps, cast copper alloy with crutch or butterfly handle, high pressure screwed down screwed for iron pipe, complete all as specified & directed.
M&L PCC 1:4:8 type D-2 using 40mm graded agg. as in foundation filling and mass concrete, complete all as specified and directed.
M&L 100 mm thick, PCC 1:2:4, type B-2, (using 40mm graded crushed stone aggregate) as in floor etc finished the surface even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
Forming contraction ( Dummy) joints 65mm deep and 10 mm wide filled with sealing compound, complete all as specifed & directed .
M&L 75 mm thick PCC, type B-2, 1:2:4, ( using 40mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without nusing extra cement, complete all as specified and directed.
Supply liquid accelarator( hardner) compound for PCC work, complete all as specified and directed. Manufacturer name : HR Enterprises/ Sintex or equivalent approved by GE.
S & F of solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site, complete all as specified and directed. Manufacturer name : Dr fixit/Pidilite or equivalent approved by GE.
S & F of 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC farme, complete all as specified and directed.
S & F of insulated PVC wall lining 40 mm consisting of PVC insulated panels having expanded polystyrenene (EPS) stuck of 2 mm thick plain colour PVC sheet duly fitted into the wall, complete all as specified and directed.
M&L for 150mm thick PCC (1:2:4 ) type B-2 (40 mm graded aggregate ) for road/hard standing even and Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green etc, complete all as specified and directed.
Forming Construction joint 30 mm deep x 10mm wide filled with sealing compound Grade B, complete all as specified and directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade B, complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as surface channels and drain etc including necessary form work, complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in coping PCC, block for hold fast including all necessary from work complete all as specified and directed.
Providing precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs and similar articles including necessary moulds/formwork set in cement mortar (1:4) complete all as specifed and directed.
M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Supply,Instllation testing and commissiong of Copper Piping with complete fittings/fixtures as per technical specification and BS: 13348 and as mentioned below:- (a) Installation of piping should be carried out as per approved medical standards with utmost cleanliness. (b) Only pipes, fittings and valves which have been degreased as per approved medical standards should be used . (c) Pipe fixing clamps for upto 42mm diameter. (d) Pipes should be non ferrous suitable for the diameter of the pipe and wherever required rigid metallic hanging or cemented supports to be used. (e) The main lines to the building to be taken overhead through heavy grade metallic poles or GI tubes with inspection points in metallic boxes wherever required . Adequate supports shall be provided while laying pipelines to ensure that the pipes do not sag.
Suitable sleeves shall be provided wherever pipes cross through walls / slabs. All pipe clamps shall be non-reactive to copper.(f) All pipe joints should be made using inert gas fluxless brazing method. (g) All joints should be of copper to copper and should be brazed by silver brazing filler material without flux while being brazed joints shall be continuously purged with oil free dry nitrogen to prevent the formation of copper oxide on the inside surface of the joint. (h) All pipes should be installed without springing or forcing. (j) All pipes should be protected against mechanical injury in a manner satisfactory to authorities having jurisdiction.(k) Test: After erection, all the new pipes cleaned or purged with the help of dry nitrogen gas. Complete system should be tested with dry nitrogen at 2 times of working pressure for 24 hours. (l) Painting: All existing and proposed exposed pipes/should be painted with two coats of Synthetic enamel paint & color codification as per IS : 2379 of 1963. and approved medical standards.
(m) All concealed pipes to have gas identification bands / labels at appropriate distance. (n) Similarly all pipes which need embedding in the wall should be tested/painted/labeled and properly insulated. (p) Certification: To be certified that pipes are suitable for the particular service and complete cross connection (anti-confusion) test should be carried out. (q) Distribution piping system: MATERIAL (PIPE): Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS: EN 13348. Copper pipe must have reputed third party inspection certificate (E.g.Lloyd‟s or Kite marked or TUV or SGS). Fittings should be made of copper conforming to BS 864 and suitable for a working Pressure of upto 17 bar and especially made for brazed socket type connections.
All copper pipes should be inspected and certified for medical use before dispatch and the pipe should be delivered plugged or capped at both ends. Note: (a) The tenderer shall design & submit complete layout drawings with proper colour code, fittings, fixtures complete for approval of GE or rep of accepting Officer before placing order and the quoted includes for the same.(b) The quoted rate inclusive of all mechanical protections with metallic pipes to pipe wherever required . Make: Mexflow/Janya/ Metal Gem/ Metalco/ Cubex/ Mandev
42mmODX 1.2 mm thick
35mmODX 1.2 mm thick
28mmODX 0.9 mm thick
22mmODX 0.9 mm thick
15mm ODX 0.9 mm thick
12mm ODX 0.7 mm thick
Supply,Installation, testing and commissioning of outlet points complete with matching probe/adopter with one end suitable for Hose & other end suitable for terminal units complete set for Oxygen, Air, & Vacuum system as per technical specification confirming to CE certified/ HTM 02-01/EN/ISO/DIN and as mentioned below:- (a) The outlets shall be modular singles, and shall incorporate nameplate color-coding. The single modular outlets shall be of a design that provides for ganging of rough-in plates in the field to form multiples. (b) The gas services shall be sequentially arranged and located as shown on the plans with a minimum centerline spacing of 5 inches (12.5 cm) between outlets. (c) The outlets shall be capable of supporting dispensing equipment without the use of slide brackets. The medical gas outlets shall be designed so that, once installed, routine service of both the primary and secondary check valves can be accomplished without removing the nameplate or gas specific portions.
(d) The primary check valve shall be unitized and of the cartridge type. So that the primary check valve can be removed for service without shutting off the gas supply to the outlet, the secondary check valve shall operate automatically to stop the free flow of the pressure gas. (e) There shall be no secondary check for vacuum or gas evacuation service. Medical gas outlets that require the removal of the nameplate or gas specific components for routine service shall not be acceptable. (f) The outlets shall Conform to CE certified/ HTM 02-01/EN/ISO/DIN and should meet with the provisions of council Directive of Medical Devices Directive. (g) All outlets are 100% tested for flow and leaks (h) The outlet nameplate shall be permanently color coded with a durable scratch-resistant and protective label. (j) Medical gas outlets shall be cleaned for oxygen service as per Medical Standards, capped and placed in a protective container for shipment. (k) The outlets shall be installed in strict accordance with manufacturer’s instructions, and tested before use in conformance with local and federal codes.
(l) Outlets shall be Double Lock Outlet type manufactured with an approx 165 mm length, Copper inlet pipe stub which is silver brazed to the outlet body. Body shall be of one piece brass construction. For positive pressure gas services, the outlet shall be equipped with a primary and secondary check valve and the secondary check valve shall have break safe mechanism and also comply to pressure test standards and rated at minimum 200 psi in the event the primary check valve is removed for maintenance.The outlet assembly should have separate colour coding for each services and will accept only corresponding gas specific adaptors. All outlets shall be cleaned and de-greased for medical gas service, factory assembled and tested.The medical gas outlets should be of quick connecting and wall mounted modular type. Terminal units must be colour coded in the front part with laser painting so that colour code last without wear and must contain an additional aluminium actuator in the front part which can be press locked and not screwed for easy service, maintenance and should be unbreakable. Make: Greggersen / Drager / Penlon / Tedisel Medical/ MEC (UK)/ CMS (UK) / MEDIKAR (Turkey)
For Oxygen ( to be fixed in new bed head panels)
For Compressed Air 4 Bar ( to be fixed in new bed head panels)
For Vacuum ( to be fixed in new bed head panels)
For Oxygen wall mounted type alongwith necessary box and necessary fitting arrangement
For Oxygen ( to be fixed in old tedisel bed head panel (Model Aura-200)
For Compressed air ( to be fixed in old tedisel bed head panel (Model Aura-200)
For Vacuum ( to be fixed in old tedisel bed head panel (Model Aura-200)
Supply, Installation, testing and commissioning of Integrated / Combined alarm -valve box as per DIN EN ISO 7396-1 or HTM 02-01 . The alarm panel shall be enclosed in a steel decorative frame powder coated duly powder coated and shall be designed to accept an electrical input range of 120-240 volts AC – 50-60 hertz. The source voltage shall be stepped down with a self-contained transformer. The panel shall contain audible and visual alarm indicators with the following features:-
(a) It should be combined with Area Alarm for low space consumption. It should provide a zone isolation facility for use either in an emergency or for maintenance purpose. The Area Valve Service Unit should incorporate a ball valve with NIST connectors either side mounted in a lockable box with emergency access. It should be reliable and easy to operate and must have NIST connectors facilitate easy purge, sample & pressure testing and emergency supply system.
(b) The unit should be pre-piped, wired and tested ready for installation into a finished building. Medical gas/vacuum services should be fixed copper, piped to and from their respective area valve service units. A color coded service identity label should be fitted behind the valve handle. The unit should provide a zone isolation facility, for use either in an emergency or for maintenance purposes. The box shall be made from steel decorative frame powder coated to prevent corrosion . All wetted parts (except seals and gaskets) should be brass or copper. Each unit assembly should be factory tested for gas tightness. Rubber pipe grommets should be provided to ensure any leaking gas does not escape from the unit into a wall cavity. All visible aluminum surfaces should be powder coated.
(c) The valve unit of the compressed gases or vacuum consists of the following components:(i) medical ball-valve DN 20 and pressure gauge per gas type.,(ii) valve group consists of valve block, shut-off valve and visible physical isolation for service., (iii) quick access by special lock and push in window, (iv) diameter connection pipe 22mm available, (v)- emergency supply inlet NIST-Coupling , pressure transmitter for each gas type.The pressure transmitter converts the current pressure to the alarm panel. The alarm panelsystem is programmed to ensure a warning signal in case of any increase or decrease of the pressure.
(d) The valves shall be bronze, ball-type, with Teflon (TFE) seats and seals. All valves shall be dual gauge ported, rated at a working pressure of 600 psi (29 in/Hg vacuum), and shall be operated by a lever-type handle, requiring only a quarter turn from a fully open position to a fully closed position. Valves shall incorporate an adjustable packing and a blow- out proof stem. Only full port valves having flow rates comparable to equivalent size of pipe shall be used. Valves shall be piped from left to right. Valves shall be provided with type K copper tubing extensions to facilitate installation. Valves shall be in-line repairable type. Each valve assembly shall be supplied cleaned for oxygen service in accordance with current medical standards. The valve tube ends shall be capped and sealed in a protective container to prevent contamination prior to installation. Gauges shall be 50 mm OD for monitoring pressure and vacuum.
(e) A fully color coded label package shall be supplied with each valve box assembly for application by the installer. The valve box shall be of minimum IP-41 with sheet steel construction powder coated to prevent rust. A single box shall house from one to three valves. Box shall be supplied with a ¾” plaster flange. Valve box assembly shall be supplied with a formed steel decorative frame powder coated which encloses an easily removable flexible window. Make: Greggersen / Drager / Penlon / Tedisel Medical/ MEC (UK)/ CMS (UK) / MEDIKAR (Turkey)
Line Pressure Alarm
Areas Alarms Panel:
3 Gas Service ( for Oxygen, Compressed Air & Vacuum)
1 Gas Service ( For Oxygen only)
Supply installation, testing and commissioning of oxygen Back Pressure Compensated flow meter with control range of 0 – 15 lpm (calibration within +/- 10% ) with 250 ml humidifier bottle made of unbreakable polycarbonate material and autoclavable at 121 degree Centigrade temperature.The flow meter shall be strict precision, durability standard and body shall be made of brass chrome plated materials.The flow tube and shroud components shall be made of clear, impact resistant polycarbonate.Flow Tube shall have large and expanded 0 – 5 lpm range for improved readability at low flows with Inlet filter of stainless steel wire mesh to prevent entry of foreign particles. The humidifier should have an integrated relief valve. Make: OXICARE ENGINEERS / GLOBAL MEDLIFE SOLUTION / LIFELINE MEDISOL / AKTIV / LMPL/ANEER/MR ENGINEER/SJK/PERFECT MEDICAL/ GLOBAL MEDITECH
Supply, installation testing and commissiong of Ward suction unit or Ward Vacuum Unit with above 1000 ml suction collection jar-1 Nos as per specifications mentioned below:- (a) The vacuum regulator should have a vacuum gauge with analog display.The scale should be in mbar or mmhg as required by the end user. (b) 1no of Suction Regulator and 1no of 1000 ml polysulfone /polycarbonate collection jar. (c) Suction regulator should be supplied with a safety jar, including and antibacterial filter and an anti-overflow safety device and should have wide membrane continuous suction controller. (d) Should have vacuum levels: 0-760 mm of Hg and Should have vacuum gauge fitted with a protective bumper device. (e) Should have on/off knob allowing for the quick restoration of a readjusted vacuum level. (f) Must have central adjustment knob with a color coded for 0 to 760 mm of Hg. Should have Polysulfone/polycarbonate 1700cc safety jar, autoclavable at 121º C at 5mins, unbreakable, fitted with an anti-overflow safety device and equipped with a plastic antibacterial filter and should be totally transparent, to ensure perfect sucked liquid visibility. Make: OXICARE ENGINEER / GLOBAL MEDLIFE SOLUTION / LIFELINE MEDISOL / AKTIV / LMPL / ANEER/MR ENGINEER/SJK/PERFECT MEDICAL/ GLOBAL MEDITECH
Supply ,installation ,testing and commissioning of medical gas hose assemblies as per standard, High pressure Hose antistatic duly colour coded for oxygen , Nitrous Oxide Compressed air and vacuum as per technical specification,antistatic and colour coded rubber tube – white for oxygen, black for compressed air and yellow for vacuum and low pressure tubes for Vacuum application.Make: Oxylitre/OXICARE ENGINEERS / GLOBAL MEDLIFE SOLUTION / LIFELINE MEDISOL / AKTIV / LMPL / ANEER
Supply, installation, testing and commissioning of Horizontal Bed Head Panel with provision of a safe efficient means of delivering services to patients staff in both general and special care applications, it is modular design made of horizontal aluminium extrusions, and ability to house medical gas termainal units ( as per specifications of tender) and electrical socket , smooth curved surfaces, no visible screws and choice of coloured décor stripe, ease of installation via separate rail-bracket or wall mounting plates, easy removal of covers for maintenance and pipeline connection, with integral twin medical rail as part of the modular extrusion design. It has segregation of services i.e. extra low voltage, normal voltage and medical gases , should be maintained throughout . Its aluminium extrusions have a polyester coating finish on all external surfaces. It have provision for nurse call, data or monitoring sockets, should be made at the point of manufacture.
It should be supplied duly prepiped , prewired and fully tested or in carcass form. "Each Horizontal Bed Head Panel shall be having a provision of (as per outlet distribution list) - min two multipin 5-15 Amps , switch socket outlet combine - it should be minimum1500 mm long."provision for nurse call (a) It shall confirm to ISO Standards with the following features (i) The headwall system should be constructed of aluminum extrusions joined together to form a carcass to suit the particular application. Unit should be factory assembled for electrical and mechanical components.
(ii) Segregation of services i.e. Low voltage supplies, High Voltage supply and Medical gases should be maintained throughout. Front fascia plate should be removable individually to access for respective service. Bed space management system with optional equipment rail. With all Equipment Rail mount Accessories. All down drops should be installed at one end preferably & Vertical drop installed at one end should be covered with Aluminum boxing with matching color. Entire pipe line should run in continuous horizontal panels with no break for each unit & length as per area where it has to be installed.
(iii) Each bedhead unit shall be supplied with electrical and electrical outlets prefitted, wired and certified. (wired up to the distribution box provided with leakage protection) facility per unit as under: Oxygen – 2 ,Vacuum – 1 ,Medical Air-1 , Holder for vacuum collection jar –1 , Nurse call switch – 1 , Infusion pump mount pole with adapter for mounting at least two infusion pumps , 5 /15 A combined Electrical outlets – 2. , Monitor Bracket .Make: OXICARE ENGINEERS / GLOBAL MEDLIFE SOLUTION / LIFELINE MEDISOL / AKTIV / TEDISEL MEDICAL / LMPL
Supply, Installation, testing and commissioning of MEDICAL LINE VALVE or ISOLATING VALVE as per CE CERTIFIED /HTM -2022/02-01/DIN/ISO/ BS EN 1057 or ball valves as per BS 1057 , rated at 400 psig, as well as full vacuum ( 29.9" Hg). Valves go from full ON to full OFF by turning the vinyl-gripped valve handle 90 degree Locking-type handles may be ordered separately when required. Copper tubing is factory installed to help prevent valve seat damage during soldering. main and riser valves are not required to be installed in a box unless specially noted or required. Make:CONEX / RB / RN/ SMI / LMPL / AUDCO/ AKTIV.
Supply and fix Regulator valve with NRV to pevent backflow of oxygen gas rated 400 psig of size 42 mm dia of gases from pipeline complete all as per specification and direction of Engineer-in-Charge. Make:CONEX / RB / RN/ SMI / LMPL / AUDCO AKTIV. Note for item No. 48 to 56, (a) The Contractor shall submit MOU with authorised Medical Service engineer/ registered Bio medical engineer services experienced in the relevant field for not less than 5 years immediately before placing work order. (b) The Contractor shall prepare & submit general arrangement drawings of entire MGPS duly vetted by any Govt hospital Authy or Military Hospital before commencement of work. (c) The Contractor shall provide comprehensive on-site warranty (Including All Spares,Accessories and Labour) for a period of 3 years from the date of final acceptance of the complete system after successful and complete installation and commissioning with regular updation of newer technology as and when evolved. (d) The Contractor shall install, depute trained manpower to maintain the medical gas pipeline system in case of any breakdowns within 24 Hrs.The technical maintenance personnel of the Contractor shall be responsible for supervision and maintenance shall be available to reach the site(s) within 1 hour's notice.
(e) If the performance of any individual equipment or system is not satisfactory, the same shall be replaced by the contractor free of cost. (f) If it is found that to meet the performance criteria, any extra equipment is required the same will be provided free of cost by the contractor. (g) All faults appearing and their rectification shall be periodically advised to the hospital, the period of inspection being not more than a month. (h) Any lacuna or lacunae noticed in the functioning of the installation as a result of any design feature shall be rectified by the contractor free of cost. (i) The Contractor shall fully associate the engineers and technicians for 167 MH during installation, testing, commissioning, operation and maintenance period. The testing of the entire system shall be carried out in the presence of IEM from MES and Officer rep (Min 02 Nos.) from Hospital authorities. (j) The Contractor shall train the staff of 167 MH the operation of complete MGPS.
M&L for flameproof point wiring with PVC FRLS insulated fire retardant stranded copper conductor cable of 1.5 sqmm in steel concealed conduit and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with and drawing 1.5 sqmm PVC FRLS insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge (Phase Neutral and earth wire shall be provided in standard colour code R,Y,B for phase, Black for neutral green for earth wire), complete all as specified and directed.
M & L for Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified and as directed.
Supply & Fix of sheet metal enclosure with DB's ( grouted in walls) double door type for MCB's 04 ways,IP-54,IK-09 with 200 Amps 240 volts rated bus bar, complete all as specified and directed.
M&L for 6 to 32 Amps MCB SP ( ISI Marked) 50 C/S 10 KA 'C' series, complete all as specified and directed.
S&F of MCB 6 to 32 Amp SPN 50 C/S 10 KA 'C' series, complete all as specified all as directed
S&F of MCB 6 to 32 Amp TPN 50 C/S 10 KA 'C' series, complete all as specified all as directed
Supply and Fix of LED flameproof tube light fitting 16 watt CMRI certified complete with all accessories prewired and connecting electrically all as required at site or directed by Engr-in-Charge.
S & F of distribution board iron clad, double door with IP-54 IK-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface, complete all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate,earth work in any type of soil, all as required at site, complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. NOTE :- Rates inclusive of necessary earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth lead upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).”
Supply & fixing of 50 KVA servo motor operated automatic voltage stabilizer suitable for operation on 3 phase 4 wire unbalanced load, unbalanced supply having following specifications :- Input 300-420 Volt, AC 3 phase, output-415 volt, AC 3 phase, stability Plus Minus , cooling natural oil cooled with first filling of ISI mark Transformer oil efficiency more than 98 %. The stabilizer shall be provided with following facilities :- a) Digital Amp Meter and volt meter to indicate input/output voltage and output current in each phase. b) Automatic low/high voltage cut off in output. c) Overload protection in output. d) Input and output terminal The entire assembly shall be housed in a steel sheet enclosure duly painted and mounted on unidirectional castor wheels for easy movement of the equipments, complete all as specified and directed. Make :- Servo/ Apex/ Powerware/Vinitec
Supply, installing, testing and commissioning of LT feeder pillar box factory made outdoor type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet with angle iron base frame made of 65 x 65 x 6mm ,45 cm height, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing switchears/MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands, complete all as specified and directed including provn of the following:- Notes :- (a) The LT panel shall be as per CPRI type tested. (b) The Contractor shall submit general arrangements drgs of panel for approval of GE before placing order.(c) The MCCBs shall be of Thermal magnetic release with Ics=100%Icu and adjustable overload setting 80% to100% (d) The provn of PCC for erecting panel is deemed to be included in quoted rate.
i) Aluminium Bus bar 200 - A mounted on porcelain insulator - 01 Set ( Set of 4 Nos)
ii) MCCB 4 pole 415 V 3 phase 125 Amp, 35 KA (Thermal Adjustable) - 01 Nos (incomming)
iii) MCCB 4 pole 415 V 3 phase 100 Amp, 25 KA (Thermal Adjustable) - 02 Nos (outgoing)
iv) MCCB 4 pole 415 V 3 phase 63 Amp, 25 KA (Thermal Adjustable) - 01 Nos (outgoing)
v) MCB SPN 32 Amp, 10 KA, "C" series type - 02 Nos
vi) Digital time switch with current carrying capacity 16 Amps 1 Ph -02 Nos
vii) Digital voltmeter 96x96mm from 0- 500 volts - 01 Nos
viii) Digital Amp meter 0-500 Amp with CT's & slection switch - 01 Nos
ix) RYB LED indicator- one set
Supply, installing, testing and commissioning of LT feeder pillar box factory made outdoor type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet with angle iron base frame made of 65 x 65 x 6mm ,45 cm height, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing switchears/MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands, complete all as specified and directed including provn of the following:- Notes:- (a) The LT panel shall be as per CPRI type tested. (b) The Contractor shall submit general arrangements drgs of panel for approval of GE before placing order.(c) The MCCBs shall be of Thermal magnetic release with Ics=100%Icu and adjustable overload setting 80% to100% (d) The provn of PCC for erecting panel is deemed to be included in quoted rate.
i) Aluminium Bus bar 320- A mounted on porcelain insulator - 01 Set ( Set of 4 Nos)
ii) MCCB 4 pole 415 V 3 phase 250 Amp, 35 KA (Thermal Adjustable) - 01 Nos (incomming)
iii) MCCB 4 pole 415 V 3 phase 160 Amp, 25 KA (Thermal Adjustable) - 01 Nos (outgoing)
iv) MCCB 4 pole 415 V 3 phase 100 Amp, 25 KA (Thermal Adjustable) - 01 Nos (outgoing)
v) MCCB 4 pole 415 V 3 phase 63 Amp, 25 KA (Thermal Adjustable) - 02 Nos (outgoing)
vi) MCB SPN 32 Amp, 10 KA, "C" series type - 02 Nos
vii) Digital time switch with current carrying capacity 16 Amps 1 Ph -02 Nos
viii) Digital voltmeter 96x96mm from 0- 500 volts - 01 Nos
ix) Digital Amp meter 0-500 Amp with CT's & slection switch - 01 Nos
x) RYB LED indicator- one set
Supply and fix of ON LOAD change over switch 415V, 50 Hz,4 pole of capacity 125 Amps in sheet steel enclosure made out of CRCA sheet duly powder coated of thickness 2mm with IP- 54 and LED indication lamps complete all as specified and directed by Engineer-in-Charge.
Supply and fix of 4 Pole MCCB 100 Amp, 50 Hz, 415 V AC with rupturing capacity 25 KA ,thermal adjustable ,Icu=100%Icu in sheet steel enclosure made out of CRCA sheet duly powder coated of thickness 3.15 mm, outdoor type with IP- 54 and LED indication lamps complete all as specified and directed by Engineer-in-Charge.
Supply and fix of 4 Pole MCCB 200 Amp, 50 Hz, 415 V AC with rupturing capacity 36 KA ,thermal adjustable ,Icu=100%Icu in sheet steel enclosure made out of CRCA sheet duly powder coated of thickness 3.15 mm, outdoor type with IP- 54 and LED indication lamps complete all as specified and directed by Engineer-in-Charge
Supply, laying and testing of LT UG cable 120 sqmm 3.5 core, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
All as per item No. 72 here in before but size 70 sq mm 3.5 core
All as per item No. 72 here in before but size 16 sq mm 4 core
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009), complete all as specified and directd. Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying of sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches, complete all as specified and directed by Engineer-in-Charge
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole, complete all as specified and directed.
M & L for ABC type fire extinguisher 6 kg hand held ISI Marked complete all as specified and as directed.
Material and labour earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, earth work in any type of soil, all as required at site complete all as specified in plate No 3 of SSR Part-I, complete all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Material and labour earthing with copper earth plate electrode of size 600 mm x600 mm x3.0 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected with 20 x 3 mm copper strip as earth lead electrode by means of nuts, bolts and washers, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, copper earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
M/L for Elastomer Insulating Mats for Electrical Purposes Class A/voltage grade upto 1.1 KV (AC) as per IS : 15652:2006 with ISI mark of thickness 2.00 mm width 1 mtr along with suitable adhesive /chemibound resin waterproofing compound and sealing material, complete all as per manufacturers' recommendations.
KEWAL SONS
M/S SURINDER KUMAR MAHAJAN
JCC ENGINEERS PRIVATE LIMITED
TRIVENI CONSTRUCTIONS
M/S INDAN FURNITURE MART
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .