| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹27.2 L+₹4.4 L (19.1%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹28.4 L+₹5.5 L (24.0%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹30.1 L+₹7.2 L (31.5%)Rejected-Finance NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹30.7 L+₹7.8 L (34.0%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹33.3 L
EMD Value
₹66,600
Closing Date
29 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Provn of certain E/M LBW and Minor works at Tibri Mil Stn under GE Gurdaspur.
2022_MES_555554_1
GE GSR-44/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE Gurdaspur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹66,600
Yes
15 Dec 2022
1 Oct 2022
5 Nov 2022
1 Oct 2022
29 Oct 2022
17 Oct 2022
Amount
Supply, errecting and commissioning 16 metres high galvanized mast lighting system suitable for 9 light fittings symmetrically fitted complete with foundation duly structuraly designed, luminaire mounted on head frame movable lantern carriage, lighting finial, outgoing terminal and control circuit for power tool motor, twin dome aviations obstruction light LED type, junction box, raising, lowering arrangement for installation and maintenance of luniniaries, double drum winch with luminaire mounting arm with power tool provided with a motor of the required rating, stainless steel hoisting rope 6mm dia. of 97/19 gauge construction complete. High Mast shall be constructed of special steel plates conforming to BS-EN 10-025 with multiple sections of effective length, continously tapered, polygonal cross section at least 20 sided, total 16m length, hot dip galvanised both internally and externally in single dipping manner, adequate door opening at base of Mast, the Mast suitable for wind speed of 180 Km/hr, as per IS-875 Pt-III, bottom outer dia of the Mast not less than 360mm and top outer dia not less than 150mm including necessary excavation and earth work including foundation for the Mast designed for SBC of soil 10 ton/sqm at 2m depth, with M-25 design mix concrete as per manufacturer's instructions with foundation bolts, nuts, anchor plate, templete etc. including Air termination, single pointed aluminium rod 12mm dia and 300mm long and necessary fitment required for protection against lightening protection.
S&F energy saving environmental friendly, long life, exclusive innovative die-cast aluminium IP 66 protection, flood light with high power LEDs as light source, suitable for high lighting 200 watt LED light luminaire, with effucacy minimum 100 lumens per watt complete with all accessories, connecting up with PVC twin core 4 Sqmm copper conductor cable all as specified and directed by Engineer-in-Charge. Note :- The contractor will submit the LM-80 and LM-79 report form manufacturer to Engineer-in-Charge for approval before incorporating the items in work
Supply, laying and testing for LT XLPE cable insulated screened PVC bedded galvanised steel strip or wire armoured, heavy duty electric power cables with stranded aluminium conductor 1100 volts grade laid in trenches, fixed on wall/ pole including brass cable glands, lugs, clamps etc., of size 25 Sqmm 4 core cable complete all as specified and as directed. Note: Excavation and earth work, sand cushioning, brick protection, GI pipe shall be measured and paid separately.
All as per Srl item No. 03 here-in-before but 16 Sqmm 4 core cable complete all as specified and as directed.
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all as specified.
Returning filling including spreading and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
Removal of surplus/spoil on a distance n.exc 50mts away including spreading, leveling etc all as specified.
M&L Sand cushioning trenches using fine sand to under ground cable, laid in two layers before laying the cable & after laying the cable complete all as specified
Supply and lay brick common burnt sub class ‘B’ old size and for protection of cable laid in trenches for under ground cable all as specified.
S&F and commissioning of LT outdoor total enclosed/ LT panel board size 0.75m x 0.50m x 0.30m approx., tottaly enclosed made out of 3mm thick CRCA sheet, dust and vermin proof with front opening, 440V, 3 phase, 4 wire having 200 amps capacity aluminium bus bar insulated with sleeves, incoming MCCB TPN 63 Amps 440 Volt 25 KA -01 No and copper wiring with multistranded cable including timer switch electronic type 01 No with necessary MCBs 20 amps 09 Nos contractors etc, cable glands, lugs and two coats of synthetic enamel paint over a coat of red oxide primer including 1.00 mx 0.75mx 0.45m platform of PCC 1:2:4 type B-1 using 40mm graded stone aggregate including provision of wiring from panel to light fitting with trailing cable 5 core 4 sqmm copper conductor stranded PVC sheathed cable drawn through and including PVC rigid/ flexible conduit with necessary fittings etc.
Supply, installation, commissioning and testing at roof top of building (Double storeyed) "Solar hot water (Heat exchanger type) system" (flat plate collectors) ISI marked based on indirect transfer of heat of capacity 400 Ltrs per day (at Temp 60°C to 80°C) confirming to IS 12933-2003 Part-I having insulation of rock wool/mineral wool 50mm thickness bottom and 25mm thickness on top with toughened tempered glass of 4mm thick and cladding with aluminium sheet 26 SWG complete with copper riser tubes, copper heater tubes, copper sheet and absorber with 40mmx40mmx6mm enameled coated MS angle iron structure with accessories fasteners etc duly grouted in PCC 1:2:4 type B-1 (30cmx30cmx30cm block) including hot water storage tank of capacity 400 litres with inner shell fabricated from stainless steel 1mm thick in cylinderical shape and outer cover fabricated from aluminium sheet 1mm thick (having insulation of rock wool) mineral wool 100mm thick & cladding with aluminium 26SWG with necessary electric back up of capacity as per manufacturer's recommendation with heat exchanger in hot water tank with necessary make up tank of stainless steel, necessary piping between collectors and hot water tank, PVC cold water tank fixed over hot water tank on MS angle iron 50mmx50mmx6mm including nuts, bolts, grouted in PCC 1:2:4 type B-1 blocks (30cmx30cmx30cm) & two coats of synthetic enamel painting over a coat of red oxide primer with temperature gauge (100°C) complete all as specified and as directed. Notes : (i) Cold water PVC tank, cold and hot water piping shall be measured and paid for separately. (ii) MS Angle structure shall be prepared as per manufacturer's instructions.
All as per Srl item No. 11 here-in-before but of capacity 700 Ltrs per day and hot water storage tank of capacity 700 litres complete all as specified and as directed.
Supply and laying galvanised GI pipes medium grade 25mm bore ISI marked with necessary fittings such as tees, elbows, bends, reducers, unions etc fixed to walls, ceiling and laid in floors, roof etc.
Supply and laying galvanised GI pipes medium grade 25mm bore ISI marked with necessary fittings such as tees, elbows, bends, reducers, unions etc laid in trenches etc.
Supply and laying galvanised GI pipes medium grade 20mm bore ISI marked with necessary fittings such as tees, elbows, bends, reducers, unions etc fixed to walls, ceiling and laid in floors, roof etc.
Supply and laying galvanised GI pipes medium grade 15mm bore ISI marked with necessary fittings such as tees, elbows, bends, reducers, unions etc fixed to walls, ceiling and laid in floors, roof etc.
Supply and fixing hot water bib cock brass chromium plated fancy type with crutch or butterfly handle screwed down suitable for 15mm bore pipe, ISI marked all as directed.
M&L for sub main wiring with two runs of single core multi stranded PVC insulated, copper conductor, grade 1100 Volt , FRLS cable of size 4 sqmm including 4 sqmm multistranded copper conductor FRLS cable PVC insulated for earthing duly connected with earth dolly, with approved colour coding including PVC rigid conduit 25mm dia. heavy grade, of appropriate dia. concealed in wall with accessories including cutting chases and making good to the disturbed surfaces as per existing complete all as specified and directed. Note :- (a) Three run of cable alongwith PVC conduit together shall be measured as single run.
Cutting existing steel tubing 40 or 50mm dia for alterations or additions including insertion of T, socket, bend and threading for complete the job in all respect.
Supply and fix gun-metal, globe or gate valves, with iron wheel head, screwed both ends ISI marked suitable for 25 mm bore iron pipe.
Supply and fix gun-metal, globe or gate valves, with iron wheel head, screwed both ends ISI marked suitable for 20 mm bore iron pipe.
S&F sheet metal enclosure DB SPN 4 way including bus bar 240 volts, double door shutter with magnetic locking system including blanking plates.
S&F MCB 32 Amp SPN 240 Volts (in coming)
S&F MCB 20 Amp SP 240 Volts (Out going)
M&L earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point including testing on completion including watering GI pipe 20mm bore medium grade, 15mm bore light grade GI pipe for protection of earth lead including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of 8mm dia MS bar, funnel & wire mesh, excavation and earth work in any type of soil complete all as specified & directed by Engr-in-charge.
S&F Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat red oxide, one under coat and one finishing coat of synthetic enamel paint .
Supply and fix for 1000 litres capacity, rotational moulded polythelene water storage tanks (ISI marked) (three layer, cylindrical vertical with closed top), hoisted and fixed in postion including 20mm bore ball brass valve, high pressure, with polythene float and flynut and connected fittings screwed for iron pipe complete all as specified and as directed.
S&F 15mm bore GI medium grade hot water pipe duly insulated with glass wool and aluminium cladding .
S&F 20mm bore GI medium grade hot water pipe duly insulated with glass wool and aluminium cladding .
P S BUILDERS
HARPAL ENGINEERS AND BUILDERS
GULSHAN SINGH GHAI AND SON
UNITED ENGINEERING CORPORATION
GORAYA AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .