Tender Value
₹11.4 Cr
EMD Value
₹9.0 L
Closing Date
2 Mar 2024, 6:00 pmClosed
CE (AF) Prayagraj
CE (AF) Prayagraj
ADDITION ALTERATION TO HANGAR AND EXTENSION AT DISPERSAL AREA FOR INDUCTION OF C 295 AT AF STATION AGRA
2024_MES_636903_1
958446/E8
Open Tender
Civil Works
547 days
AGRA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (AF) Tech Area Agra
₹9.0 L
Yes
25 Apr 2024
11 Jan 2024
9 Mar 2024
11 Jan 2024
2 Mar 2024
17 Feb 2024
Amount
SCHEDULE A PART I (BUILDING WORKS)
Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part I .
Sch A Part II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II.
Sch A Part III (INTERNAL ELECTRIFICATIONS)
Lump sum price worked out by the contractor for Internal Electrifications as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV .
Sch A Part V (EXTERNAL ELECTRIFICATIONS)
Lump sum price worked out by the contractor for External Electrifications as listed in Sch ‘A’ Part V.
Sch A Part VI (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI.
Sch A Part VII (ADDITION / ALTERATION TO BUILDINGS)
Lump sum price worked out by the contractor for ADDITION / ALTERATION TO BUILDINGS as listed in Sch ‘A’ Part VII
Sch A Part VIII (ROAD/PATH)
Lump sum price worked out by the contractor for ROAD/PATH as listed in Sch ‘A’ Part VIII
Sch A Part IX (TARMAC)
Lump sum price worked out by the contractor for TARMAC as listed in Sch ‘A’ Part IX
Sch A Part X (LIGHTENING PROTECTION)
Lump sum price worked out by the contractor for LIGHTENING PROTECTION as listed in Sch ‘A’ Part X
Sch A Part XI (SITE CLEARANCE)
Lump sum price worked out by the contractor for Site Clearance as listed in Sch ‘A’ Part XI
Sch A Part XII (Miscellaneous Items of B/R and E/M)
Supply and fixing Flame proof weather proof LED fixture light fitting 2x 18 Watt in die cast aluminium housing with high resistant toughened glass recommended for gas/vapour group with IP-65 Protection with all accessories such as in built LED drivers, holders and other fittings connecting from ceiling rose to fitting including provision of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 RM long for connection complete with fixing arrangement complete all as specified & directed.
Supply and fixing flame proof exhaust fan of size 305 mm (12") sweep (heavy duty) single phase 220/230 volt AC 1440 RPM, with louvered shutters including mounting frame, nut, bolts, washer, fasteners etc and connecting exhaust fan to ceiling rose including provision of three core flexible copper cable of size 1.5 Sqmm not less than 0.5 RM long for connection complete with fixing arrangement complete all as specified & directed.
Supply & Fixing in replacement of three phase industrial socket with MCB TPN 63 Amps capacity with sheet steel enclosure mounted on wall with all fixing arrangements complete all as specified & directed.
Supply & Fixing the Industrial wall mounted plug socket surface mounting type single phase+neutral+earth of 230 volts 32 Amps IP-67 protection with straight plug of 2P+E of 32 Amp capacity with complete all as specified and directed.
Taking down carefully old unserviceable hangar/high bay light fittings of any type and any capacity and deposited to MES store yard complete all as specified and directed.
Supply & Fixing LED high bay light fitting of 150 watt IP-65 protection including connecting PVC flexible three core copper wire from ceiling rose to light fittings with flexible conduit covering the wire and suitable clamps, nut bolts to erect the light fixing inlcluding steel structure of any section required for fixing/mounting of light complete all as specified & directed.
Material & Labour for bore well earthing in repair by DTH (Pneumatic drill machine) machine up to depth of 50 RM below normal ground level of 150mm dia to insert the MS casing pipe of 125mm dia up to 12RM depth and suitable for inserting the earth electrode 40mm dia GI pipe medium grade duly drilled hole 12mm dia on pipe, 150 mm C/C on both side of pipe including lowering in bore well up to depth of 49.5RM and 0.5 RM above ground level and the GI pipe will be braced with Flat Iron clamps at top of size 32x6mm including nut bolts. The bore well should be filled with commercial salt charcoal dust and magnesium phosphate of 300mm layer each up to the full length of pipe the bore well casing pipe should have 12 RM of length 150mm dia with 5 mm wall thickness MS pipe for protection of bore well. Welding of GI strip with flat iron 50x6mm on earth electrode of length 0.5 RM and include up to 7.5 RM to the test point and GI tubing light grade 50 mm dia up to 7.5 RM from the bore well including test point gun metal or phosphorus bronze size 75x75x25mm, drilled screwed including 3 Nos, 8mm dia, 25mm long hex head screw and PCC 1:2:4 tupe B-1 earth pit foundation surrounding the bore well 600x600x300mm and pit cover complete all as directed by GE/Engineer-in-Charge.
Material & Labour for brick masonary valve pit chamber of size 900 mm x 900 mm x 900 mm (internal dimension of chamber) depth of chember to be reckoned from the top of PCC in foundation to top the MS cover as 60 cm and including MS sheet cover fabricated from 3.15 mm thick MS sheet and frame of angle iron 50 mm x 50 mm x 5 mm with fixing arrangement, mild steel butt hinges and locking arrangement and painting two coats of synethetic enamel paint over one coat of red oxide primer on MS cover and frame, inlcuding necessary excavation and earth work in any type of soil, returning filling in approved soil and disposal of surplus soil to a distance not exceeding 50 RM, 150 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation, brick work in cement sand motor in (1:6) 15 mm thick plastering in cement mortar in (1:4) (both internally and externally) 100 mm thick PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in flooring complete all as specified & directed.
Demolition of damaged road manually or mechanical of any description and in any position not otherwise specifically provided for including disposal of unserviceable material or rubish outside MOD land complete all as specified and directed.
Material & Labour for taking down bird proofing with frame upto 25 m height using necessary scaffolding of any size and description & removing from site complete all as specified & directed on site.
Supply & Fixing powder coated aluminium fillets / frame work for bird proofing of any size and any thickness, for fixing of wiremess at height of work upto 25 mtr jointing cleats, screws dash fasteners, suspenders of appropriate aize, plugs for fixing with walls / ceilling etc (including necessary formwork or scafolding requireds) complete all as apecified and directed.
Material & Labour for preparation of the dry concrete surface using mild scarification / grinding equipment to remove any loose material, contaminations and laitance, removal of oil and grease by burning method and removing of existing paints of any thickness to provide a sound, levelled, fine gripping surface and cutting 6mm groove with 1 mtr interval in both direction including cleaning the entire floor area using a powerful industrial vaccum cleaner with filling of small chips, minor imperfections, dead cracks, pot holes, construction joint and making good the existing damaged concrete with good quality epoxy mortar screed of approved make and repair of broken concrete surface with sound quality of Micro concrete over the epoxy resin concrete bonding coat primer Cipoxy 14 of M/s Cipy Polyurethane Pvt Ltd or other equivalent make as approved complete all as specified and directed.
Material & Labour for applying 5 mm polyurethane flooring medium to heavy duty, solid colour three component, water dispersed polyurethane based self-smoothening sika floor @ 21 N purcen (IN) at 5 mm thickness (scratch coat+body coat) having (a) Compressive strength > 45 MPa after 28 days at 27 degree C as per ASTMC-579 (b) Flexural strength - 14.7 MPa after 28 days at 27 degree C as per ENISO EN-196 (c) Tesile strength -6.5MPa after 7 days at 274 degree C as per ENISO-572-2 (d) Thermal expansion co-efficient 1.6x10 power-5 mm per mm degree C as per ASTMD-696 (e) Bond strength > 2.5 N.mm2 as per EN-1542 (f) Shore D hardness-80 to 85 as per ASTMD 2240 (g) Abrasion resistance-861 mg as per ASTMD 4060-H22/1000 Cycles/1000g (h) Impact resistance ->20 joules at 4 mm thickness as per IS :101 Part-5:1999
Taking down existing door frame / shutters of area exceeding 60 Sqm and not exceeding 80 Sqm by hydraulic/ mechanical cranes other tools & plant, necessary scaffolding required for lowering down the door shutters carefully without causing damage to other components of hangars for repairing work and re-fixing the door shutters in same position or location after necessary repairs complete all as specified and as directed. Note :- Damages if any, caused due to poor workmanship shall be made good by the contractor at his own cost to match with the existing position complete without any extra cost to the department. Note : Wheel & ball bearing shall be measured & paid seperately
Supply only in repair wheel made up of taplon / cast iron wheel, including fixing only of ball bearings 02 Nos circlips, 01 No shaft of dia 25 mm x 120 mm long or size as per required at site, including necessary welding, drilling and other fittings etc complete all as specified and as directed.
Supply only in repair Ball bearing roller of make SKF of size 100 x 60 mm or size as per site requirement complete all as specified and as directed.
Supply & Fixing stainless steel (SS-304 grade) wind turbine ventilator of 24" throat dia size with capacity of 2700 cfm to be mounted on top of FRP base plate of size 5½ x 3½ x 2mm thick with venture dome, including necessary cutting of existing roof sheets, sealing with water tight arrangement etc complete all as specified and directed by GE/Engineer-in-charge. Technical specification of fan :- No./MOC of fins : 42/s.s Thickness of fins: 0.50mm M.O.C of top cover & mounting ring S.S internal fittings (shaft, Base Frame & connecting roads) GI Revolution Mechanism : Double Jet Sealed Ball Bearing or Self Lubricated Nylon Bush. Make:- Duraplast/Nuplast/Aircool or eqivalent make as approved by GE.
Material & Labour for conventional RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users complete all as specified and as directed. (Drg No. TD 750 Sheet No 1/1 to 1/2 Dated 21 Mar 2018)
Material & Labour for RCC hume pipe septic tank design to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc complete for 5 User complete all as specified and as directed.
M&L for Soakage wells excavation for size 3 M dia X 3M effective depth, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 cement concrete including intercepting chamber and screen chamber made of Brick masonary in CM 1:4, RCC cover slab in M-25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size complete all as specified and as directed.
Supply, installation, commissioning and testing of inverter type Split Air Conditioner of 1.5 TR (4500 Kcal/Hr) capacity, complete with cordless remote control unit and with built-in air-ionizer and plasma filter for better air quality with minimum 5 Star rating and EER of 3.5 and above. Indoor unit Hi wall mounted type, suitable for 230 Volt, 50 Hz, Single phase AC supply and capable for performing the function as cooling/heating, dehumidifying, air circulating and filtering. The air conditioners shall be complete with automatic temperature control, cut-in, cut-out for variable temperature range 16 to 30 degree C. The differential of cut-in cut-out shall not be greater than + 1.75 degree C to be provided with electronic thermostat as per IS : 11338 of 1985. Outdoor unit of the air conditioner shall be fitted with discharge cooled type rotary / scroll compressors operating on non-CFC refrigerants (like R-410A or equivalent) with suitable rated capacitor start electric motor equipped with overload protection and mounted on resilient mountings for quiet operations. The minimum thickness of base in outdoor unit shall be 1.20mm and sheet thickness for rest of the body shall be 0.70 mm. The casing of the indoor unit shall be made of ABS/HIPS/GS and shall be inpact resistant. The control box of indoor unit shall withstand flame–retardant test to grade V-O and as per UL-94. For impact resistance test, the unit duly packed and dropped from height of 1 RM shall show no damages. The filter packs provided shall be washable.
Supply, installation, commissioning and testing of inverter type Split Air Conditioner of 2 TR (6000 Kcal/Hr) capacity, complete with cordless remote control unit and with built-in air-ionizer and plasma filter for better air quality with minimum 5 Star rating and EER of 3.5 and above. Indoor unit Hi wall mounted type, suitable for 230 Volt, 50 Hz, Single phase AC supply and capable for performing the function as cooling/heating, dehumidifying, air circulating and filtering. The air conditioners shall be complete with automatic temperature control, cut-in, cut-out for variable temperature range 16 to 30 degree C. The differential of cut-in cut-out shall not be greater than + 1.75 degree C to be provided with electronic thermostat as per IS : 11338 of 1985. Outdoor unit of the air conditioner shall be fitted with discharge cooled type rotary / scroll compressors operating on non-CFC refrigerants (like R-410A or equivalent) with suitable rated capacitor start electric motor equipped with overload protection and mounted on resilient mountings for quiet operations. The minimum thickness of base in outdoor unit shall be 1.20mm and sheet thickness for rest of the body shall be 0.70 mm. The casing of the indoor unit shall be made of ABS/HIPS/GS and shall be inpact resistant. The control box of indoor unit shall withstand flame–retardant test to grade V-O and as per UL-94. For impact resistance test, the unit duly packed and dropped from height of 1 RM shall show no damages. The filter packs provided shall be washable.
Supply & Fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input volyage variation between 170 Volt to 250 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% with time delay facility and of capacity 04 KVA complete all as specified and directed.
Supply & Fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input volyage variation between 170 Volt to 250 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% with time delay facility and of capacity 05 KVA complete all as specified and directed.
Supply & Fixing the LED flood light fitting of IP-66 protection having Pressure dia cast aluminum housing with heat resistant toughened glass, individual LED lenses complete 230 volts, 50 Hz of capacity 250 Watt connecting with three core flexible copper conductor of 1.5 Sqmm nominal area from light fitting to connector/junction box complete all as specified and directed.
Supply & Fixing of loop-in/loop-out box of outer size 155x210x92mm made out of FRP body (hot mulded type) with IP-63 protection and locking with screws alongwith 5/6 Amp rating MCB SP-01 No, up to 50 Amp rated 2 pole connector suitable to insert the cable size 25 Sqmm-01 No, with neutral link and din rail suitable for mounting the MCB/Connector complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on PCC/Brick work pillar including cable glands, aluminum lugs/thimbles for incoming and out going cales complete all as specified and directed.
Supply, Install, testing and Commissioning CPRI type tested, factory made, totally enclosed, IP-54 protection dust, weather and vermin proof, CRCA sheet out door LT Panel for 415Volt, 3 phase 4 wire, 50 Hz AC system with TPN tinned copper bus bar of rating 1.5 times that of controlling MCCB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar general construction confirming to IS : 8623/93, having bottom base channel of MS section not less than 75mm x 75 mm x 5 mm entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size (minimum 1.5 Sqmm) PVC insulated copper conductor cable, cable alloys, cable gland plates in two half inculding LED indicating lamp for all phases and mounted on suitable PCC foundation for the complete panel base with following detailed specification control and accessories complete:-
OUTER SHELL : The outer shell shall be made of min 3 mm thick CRCA sheet supported on on MS angle iron of section 75mm x 75 mm x 5 mm frame with openable front & back with concelaed hinges, single door system, lockable/ openable by keys from both sides, having flush pattern fancy locks, louvers & air vent with gasket for natural flow of air. The bottom of the outer shell contains a detachable plate with hing provision for entry of armoured cable with adequite size glands. Provision of earthing studs at bottom and threaded lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided.
INNER SHELL : Inner shell made of 2 mm thick CRCA sheet compartmentalized to accomodate each control gear, front openable, single door system lockable/openable with "U' type gasket to make the inner shell completely vermin proof having chromium plated locks (2 Nos in each compartment) All control wiring shall be with not less than 1.5 Sqmm multi-stranded copper conductor and shall be properly bunched / tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x75x5 mm duly pained with zinc based primer. A detachable predrilled gland plate of thickness 3.15 mm should be used at the bottom. An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell.
(A) INCOMING: (i) MCCB 4 pole, 160 Amp, 415 Volt, breaking capacity 25 KA, with fixed thermal & magnetic settings Ics=100%Icu ----- 1 No. (B) OUTGOINGS: (i) MCCB 63 Amp, 4 pole, 415 Volt, breaking capacity 16 KA, with fixed thermal & magnetic settings, Ics=100%Icu----05 Nos. (ii) MCB SPN 40 Amps 230Volts 10KA-----04Nos. Note: (i) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:4:8 type D-2 using 40mm graded crushed stone aggregate 300 mm around the panel shall be inclusive in the rate quoted. (ii) Drawing of LT Panel shall be submitted by manufacturer will be approved by GE before placing order.
Supply, Install, testing and Commissioning CPRI type tested, factory made, totally enclosed, IP-54 protection dust, weather and vermin proof, CRCA sheet out door LT Panel for 415Volt, 3 phase 4 wire, 50 Hz AC system with TPN tinned copper bus bar of rating 1.5 times that of controlling MCCB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar, general construction confirming to IS : 8623/93, having bottom base channel of MS section not less than 75mm x 75 mm x 5 mm, entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size (minimum 1.5 Sqmm) PVC insulated copper conductor cable, cable alloys, cable gland plates in two half inculding LED indicating lamp for all phases and mounted on suitable PCC foundation for the complete panel base with following detailed specification control and accessories complete:-
OUTER SHELL : The outer shell shall be made of min 3 mm thick CRCA sheet supported on on MS angle iron section 75mm x 75 mm x 5 mm frame with openable front & back with concelaed hinges, single door system, lockable/ openable by keys from both sides, having flush pattern fancy locks, louvers & air vent with gasket for natural flow of air. The bottom of the outer shell contains a detachable plate with hing provision for entry of armoured cable with adequite size glands. Provision of earthing studs at bottom and threaded lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided.
INNER SHELL : Inner shell made of 2 mm thick CRCA sheet compartmentalized to accomodate each control gear, front openable, single door system lockable/openable with "U' type gasket to make the inner shell completely vermin proof having chromium plated locks (2 Nos in each compartment) All control wiring shall be with not less than 1.5 Sqmm multi-stranded copper conductor and shall be properly bunched / tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x75x5 mm duly pained with zinc based primer. A detachable predrilled gland plate of thickness 3.15 mm should be used at the bottom. An inspection lamp with 11 Watt CFL shall be fitted on top side of inner shell.
(A) INCOMING:- (i) MCCB 4 pole, 160 Amps, 415 Volt, breaking capacity 25 KA, with fixed thermal & magnetic settings, Ics=100%Icu ------01 No. (B) OUTGOINGS: (i) MCCB 4 pole, 63 Amps, 415 Volt, breaking capacity 16 KA, with fixed thermal & magnetic settings, Ics=100%Icu------06 Nos. (ii) MCB SPN 40 Amps, 230Volts, breaking capacity 10KA----04Nos. Note: (i) Cost of PCC platform 50mm thick 1:2:4 Type B-1 over 75mm thick sub base 1:4:8 type D-2 using 40mm graded crushed stone aggregate 300 mm around the panel shall be inclusive in the rate quoted. (ii) Drawing of LT Panel shall be submitted by manufacturer will be approved by GE before placing order.
Supply, install, testing and commissioning Hand operated Crane with I-Section rail of suitable dimension mounted on gantry over bearing plate fixed with suitable dia and numbers of nuts and bolts complete all as per manufacture design with following specifications:- (a) Capacity : 01 Ton (b) Lifting height : 4.5 M (from FFL to Bottom of hook) (c) 4 Bays of 4 RM (approx) (d) Clear Span : 9 to 11 RM (approx) (e) Bridge Single Girder I section Beam type rolled steel joist as per IS : 807/3177 bolted to end carriage (f) End carriage : Fabricated with rolled steel sections/plates (g) LT wheel : Two numbers straight treade type EN-8 forged steel, double flanged, LT wheel shall be provided in each of the two encarriage these wheel shall be supported on steel axies. (h) Hoisting : tripple super gear chain pully block with grade 80 alloy steel (j) Trolly : Overhead mono rail travelling trolley to move with the help of endless chain (k) Operations : All operations by manual with the help of endless chain (l) Gears : As per IS : 4460 made from EN-08 and supported on ball bearings (m) Pinion/Axles : Made from EN-9 heat treated carbon alloy sateel. (n) Bearings : Two nos heavy duty sealed ball bearing shall be provided in each wheel for smooth running (o) Hook : Heavy duty steel forged capable to with stand shock loads free to swivel & rotate as per IS : 8610/3815 (p) Load chain : 8mm/2 falls grade 80 alloy steel as per IS : 6216. (q) Head chain : 6mm grade 30 MS chain as per IS : 242.
Deduct Schedule of Credit of Rs. 9,09,124.00 as brought out from Sr Page No. 51(R) of tender
YAUK ENGINEERS
imran construction company
B D Raizada Projects Pvt Ltd
ATUL CONSTRUCTION CO.
SNG BUILDERS AND ENGINEERS
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid