Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical C 5 156 YAMUNA VIHAR EAST DELHI DELHI 110053 | NORTH EAST DELHI | DELHI | 110053 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical B 3 88 PASHCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical F 298 GROUND FLOOR VIKASPURI SOUTH WEST DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | Admitted-Fee/PreQual/Technical |
Tender Value
₹88.9 L
EMD Value
₹1.8 L
Closing Date
9 Nov 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Assistant Executive Engineer-in-charge, AC Division, Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
SITC of Air Conditioners in Different Locations of Hostel in IIT Delhi
2026_IIT_932469_1
IITD/WORKS (SP-5449)/2026
Open Tender
Miscellaneous Works
Works
75 days
IIT Delhi Hauz Khas
As per tender documents
14 documents required · 14 mandatory
₹0
₹1.8 L
10 Nov 2026
30 Oct 2026
10 Nov 2026
30 Oct 2026
9 Nov 2026
30 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.5 | SUB HEAD -1 (VRV/VRF) | - | - | - | - |
| 1Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 °C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50 Hz ac power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building) For Cooling only. The scope of work shall include lifting of outdoor unit upto 1st floor of the hostel mess. | |||||
| 1.01 | 22 HP (For Satpura Hostel) | 22 | Per HP | 100 | ₹2,200 |
| 1.02 | 26 HP (For Kumaon Hostel) | 26 | Per HP | 100 | ₹2,600 |
| 1.03 | 32 HP (For Vindhyachal Hostel) | 32 | Per HP | 100 | ₹3,200 |
| 1.04 | 45 HP (For Shivalik Hostel) | 45 | Per HP | 100 | ₹4,500 |
| 2Supplying, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase ac supply, complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 deg C DB and 19 deg C WB temperature. (Make will be same as of Outdoor) | |||||
| 2.01 | 1.0 TR (For Shivalik Hostel) | 1 | Each | 100 | ₹100 |
| 2.02 | 1.6 TR (For Shivalik Hostel) | 4 | Each | 100 | ₹400 |
| 2.03 | 2.0 TR (For Shivalik, Kumaon & Vindhyachal Hostel) | 37 | Each | 100 | ₹3,700 |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
BOQ_979899.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .