| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC OK | |
| 2 | L2₹17.3 L+₹2.3 L (15.0%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹17.8 L+₹2.7 L (17.7%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹20.0 L+₹4.9 L (32.4%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹21.7 L+₹6.6 L (44.0%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
6 Jun 2020, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
CWE/P-58/2019-20 SPECIAL REPAIR AND RE-ROUTING LT LINES AND REPAIR TO LT PANEL AT BASOLI MIL STATION UNDER GE BASOLI
2020_MES_328732_1
CWE/P-58/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Basoli
class E and above Category b i
9 documents required · 9 mandatory
₹500
Yes
GE Basoli
₹40,000
Yes
6 Jul 2020
26 Feb 2020
8 Jun 2020
26 Feb 2020
6 Jun 2020
11 Mar 2020
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25cm completed all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point completed all as specified and directed.
M & L for sub class 'B' bricks well burnt old size laid dry flat for protection of cable complete all as specified and directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying and punned upto 18 cm, stretching and testing the cable as specified in clause 19.75 of SSR Part-1
M&L for PCC ( 1:2:4) type B1 using 20mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface completed all as specified and directed.
M&L for PCC ( 1 : 3 : 6 ) type C2 using 40mm graded stone aggreghate for foundation of poles and stay assembly completed all as specified and directed.
Supply & errection of pre stressed concrete pole 9 meters long 102mmx172 mm at top and 102x279mm at bottom class-10 in PCC (1:3:6) type C2 using 40 mm graded stone aggregate in foundation including painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where requiredcomplete all as specified and directed. Note :- Earth work and PCC work shall be paid and measured andpaid seperately
Supply and fixed in replacement aluminium conductor steel re-inforced (ACSR) Ferret of size 6/1x3.00 mm / weasal of size 6/1x2.59 mm and squirrel of size 6/1x2.11 mm for LT lines on concrete poles, stretching without kinks and bends, binding with (rates inclusive) binding wire complete all as specified and directed.
S&F in structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat , one finishing coat of aluminium paint and epoxy coating, including taking down old corroded structural steel all as directed.
S & F in shackle type,vitreous Insulator incl one galvanised mild steel spindle, two galvanised iron washers,and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt,and as directed by engineer in charge.
S/F stay assembly complete comprising of 20mm dia 40cm long stay bow rod 20mm dia x 1.8 Mtr long galvanised stay rod threaded and with nuts including 300mmx300mmx6mm thick plate necessary clamps etc as shown on plate No. 1 on page 495 of SSR Part-I, 2009 complete all as specified and directed. Note : Loop type insulator, stay clamp, stay wire, excavation and concrete work measured separately).
S & F galvanised steel stranded stay wire size 7/4mm for stay assembly complete all as specified and directed.
S & F loop type insulator iwith complete fiting porcelain, vitreous white or brown large size with over all dismensions 90x140mm , clearance of hole 25.5mm complete all as specified and directed..
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire of size 4 mm dia and 15 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all shown in electrical plate no. of SSR part I of-2009 complete all as specified and directed.
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE, of cross section area 240 Sq mm X 3.5 core, PVC insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade complete all as specified and directed. Note :- (I) Earth work, sand cushioning and brick protection to cable shall be measured and paid separately .
All as per Srl item no. 17 here-in-before but 150 Sq mm X 3.5 core
All as per Srl item no. 17 here-in-before but 120 Sq mm X 3.5 core
All as per Srl item no. 17 here-in-before but 95 Sq mm X 3.5 core
All as per Srl item no. 17 here-in-before but 70 Sq mm X 3.5 core
All as per Srl item no. 17 here-in-before but 50 Sq mm X 3.5 core
All as per Srl item no. 17 here-in-before but 25 Sq mm X 3.5 core
All as per Srl item no. 17 here-in-before but 300 Sq mm single core
Taking out the old unsv AB cable of ant type , 70 sqmm x 3.5 core to 150 sqmm x 3.5 core in any position from pole in any height or passing through pipe/fixed on pole to pole/wall all as specified and directed.
S & F in repairs cable end joint kit for 1100 volt, out door type heat shrinkable type joint complete with all jointing material and accessories suitable for 3.5 core cable of size 50 sq mm to 185 sqmm all as directed.
S&F DWC high density polyethelene pipes in replacement having 63/50 mm outer dia mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including aking down the old unserviceable complete all as specified and directed. Make -Trupati /Equivalent
S&F DWC high density polyethelene pipes in replacement having 90/76 mm outer dia mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including aking down the old unserviceable complete all as specified and directed. Make -Trupati /Equivalent
S&F DWC high density polyethelene pipes in replacement having 120/103 mm outer dia mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including aking down the old unserviceable complete all as specified and directed. Make -Trupati /Equivalent
M & L for fabrication of double door and outdoor type incorporated with busbar chamber of size LxBxD (800x 600x400mm) having with aluminium busbar capacity 500 amps insulatted with RYB & black PVC insulated on tape suitable for 415 volts 3 phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS sheet not less than 3.15 mm thick also having provision for incoming/outgoing COS/ cables, 02 Nos earth terminal point complete with 10mm dia bolt of suitable length, 02 nos nuts and 02 Nos Washers3mm thick complete earth . The panel body must be painted with powder coated paint after the complete 7 tanks dip process to remove all impurties from the panel sheet, all the door must be fixed with detachable pin type hinges,steel door locking system, bus bar shall be through aluminium strip properly insulated fixed on SMC/DMC insulators. Panel body shall be fixed on iron angle frame of size 40x40x5mm, 40 cm grouted in PCC 1:2:4 type B 1 (using 20 mm graded crushed stone aggregate) and 40 cm above the ground level duly painted with two coat of synthetic enamel black paint over a coat of red oxide primer all as specified and directed. Following accessories shall be included in feedar pillar box :- RYB LED indicator lamp-03 Nos
M & L for fabrication of double door and outdoor type incorporated with busbar chamber of size LxBxD (800x 600x400mm) having with aluminium busbar capacity 400 amps insulatted with RYB & black PVC insulated on tape suitable for 415 volts 3 phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS sheet not less than 3.15 mm thick also having provision for incoming/outgoing COS/ cables, 02 Nos earth terminal point complete with 10mm dia bolt of suitable length, 02 nos nuts and 02 Nos Washers3mm thick complete earth . The panel body must be painted with powder coated paint after the complete 7 tanks dip process to remove all impurties from the panel sheet, all the door must be fixed with detachable pin type hinges,steel door locking system, bus bar shall be through aluminium strip properly insulated fixed on SMC/DMC insulators. Panel body shall be fixed on iron angle frame of size 40x40x5mm, 40 cm grouted in PCC 1:2:4 type B 1 (using 20 mm graded crushed stone aggregate) and 40 cm above the ground level duly painted with two coat of synthetic enamel black paint over a coat of red oxide primer all as specified and directed. Following accessories shall be included in feedar pillar box :- RYB LED indicator lamp-03 Nos
M & L for fabrication of double door and outdoor type incorporated with busbar chamber of size LxBxD (750x 600x350mm) having with aluminium busbar capacity 400 amps insulatted with RYB & black PVC insulated on tape suitable for 415 volts 3 phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS sheet not less than 3.15 mm thick also having provision for incoming/outgoing COS/ cables, 02 Nos earth terminal point complete with 10mm dia bolt of suitable length, 02 nos nuts and 02 Nos Washers3mm thick complete earth . The panel body must be painted with powder coated paint after the complete 7 tanks dip process to remove all impurties from the panel sheet, all the door must be fixed with detachable pin type hinges,steel door locking system, bus bar shall be through aluminium strip properly insulated fixed on SMC/DMC insulators. Panel body shall be fixed on iron angle frame of size 40x40x5mm, 40 cm grouted in PCC 1:2:4 type B 1 (using 20 mm graded crushed stone aggregate) and 40 cm above the ground level duly painted with two coat of synthetic enamel black paint over a coat of red oxide primer all as specified and directed. Following accessories shall be included in feedar pillar box :- (i) MCCB 100 Amps 25 KA rating, TP, 415 V-01 No (outcoming) (ii) RYB LED indicator lamp-03 Nos
M & L for fabrication of double door and outdoor type incorporated with busbar chamber of size LxBxD (750x 600x350mm) having with aluminium busbar capacity 400 amps insulatted with RYB & black PVC insulated on tape suitable for 415 volts 3 phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS sheet not less than 3.15 mm thick also having provision for incoming/outgoing COS/ cables, 02 Nos earth terminal point complete with 10mm dia bolt of suitable length, 02 nos nuts and 02 Nos Washers3mm thick complete earth . The panel body must be painted with powder coated paint after the complete 7 tanks dip process to remove all impurties from the panel sheet, all the door must be fixed with detachable pin type hinges,steel door locking system, bus bar shall be through aluminium strip properly insulated fixed on SMC/DMC insulators. Panel body shall be fixed on iron angle frame of size 40x40x5mm, 40 cm grouted in PCC 1:2:4 type B 1 (using 20 mm graded crushed stone aggregate) and 40 cm above the ground level duly painted with two coat of synthetic enamel black paint over a coat of red oxide primer all as specified and directed. Following accessories shall be included in feedar pillar box :- (i) MCCB 100 Amps 25 KA rating, TP, 415 V-02 No (outcoming) (ii) RYB LED indicator lamp-03 Nos
M & L for fabrication of double door and outdoor type incorporated with busbar chamber of size LxBxD (750x 600x350mm) having with aluminium busbar capacity 400 amps insulatted with RYB & black PVC insulated on tape suitable for 415 volts 3 phase 4 wire system 50 c/s fixed on SMC/DMC in step way complete with dust and vermin proof provisions made of CRCA MS sheet not less than 3.15 mm thick also having provision for incoming/outgoing COS/ cables, 02 Nos earth terminal point complete with 10mm dia bolt of suitable length, 02 nos nuts and 02 Nos Washers3mm thick complete earth . The panel body must be painted with powder coated paint after the complete 7 tanks dip process to remove all impurties from the panel sheet, all the door must be fixed with detachable pin type hinges,steel door locking system, bus bar shall be through aluminium strip properly insulated fixed on SMC/DMC insulators. Panel body shall be fixed on iron angle frame of size 40x40x5mm, 40 cm grouted in PCC 1:2:4 type B 1 (using 20 mm graded crushed stone aggregate) and 40 cm above the ground level duly painted with two coat of synthetic enamel black paint over a coat of red oxide primer all as specified and directed. Following accessories shall be included in feedar pillar box :- (i) MCCB 100 Amps 25 KA rating, TP, 415 V-02 No (In coming)
(ii) MCB TPN 63 Amp 10 KA rating 240 volts C series- 03 Nos (out coming) (iii) MCB SPN 63 Amp 10 KA rating 240 volts C series- 06 Nos (out coming) (iv) RYB LED indicator lamp-03 Nos
S&F in replacment of on laod change over switch in sheet steel enclosure with front handle of capacity 315 Amps, four pole, 415 Volts complete all as specifed and directed.
Dismantling and taking down old unserviceable PCC LT pole of any size any location including earth work and removing/breaking the old PCC in complete all as specified and directed.
Dismantling of steel work ( brackets,clamps, channels including disc and pin insulators, nut & bolts) from existing pole all as specified and direc ted by Engr-in-Charge.
Dismantling insulators any type, any size and depositing to the MES store yard complete all as specified and directed.
S & F for galvanised steel wire 4 mm dia all as specified complete all as specified and directed..
S & F in replacement of GI strip of size 32 x 6mm beyond 7.5 m beyond earthing lead other places complete all as specified and directed.
S & F in replacement of GI pipe 40 mm dia light gradefor mechanical protection to earth strip complete all as specified and directed.
Taking down old serviceable PCC/Steel Tubular LT pole of any size any location including earth work and removing/breaking the old PCC in complete and made for reuse and shifting to adjacent location for replanting all as specified and directed.
Errecting of steel tubular/PCC LT pole retrieved against Srl item No 08 here-in-before complete and planted in the earth in PCC (1:3:6) type C2 using 40 mm graded stone aggregate in foundation all as specified and directed. Note :- Earth work and PCC work shall be measured and paid separately.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
SHUSHANT ASSOCIATES
Ashoka Engineers
dinesh enterprises
Standard engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .