Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAdmitted-Finance | ₹14.4 L | L1 | Admitted-Finance |
| 2 | L2₹14.5 L+₹1,180 (0.08%)Admitted-Finance | ₹14.5 L+₹1,180 (0.08%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Due to not full fill the term and condition of NIT |
| Sl No | Description | Qty | Unit | Powersure Technologies L1 | NS INSTRUMENTS AND CONTROLS L2 |
|---|---|---|---|---|---|
| 1.01 | S/I/T/C of C.M. System including all accessories at Mandawali -1 Booster pumping Station with following works:- SITC of Chlorine Analyzer - Ready to use system for measuring free chlorine, chlorine dioxide or ozone. The measuring system consists of the following devices: MAC 100 Multipara meter signal converter. OPTISENS CL 1100 sensor. The OPTISENS CL 1100 is a single rod sensor with integrated reference electrode. This potentiostatic sensor with 2 gold electrodes is in combination with our signal converter suitable for measuring free chlorine, chlorine dioxide or ozone. In addition to excellent measurement accuracy this leads to a high chemical and mechanical resistance of the electrode and therefore to a long service life with stable measurement performance, The measuring system OPTISYS CL 1100 is already equipped with flow-through cells for temperature sensor and OPTISENS CL 1100 sensor - ASR - Automatic Sensor Cleaning feature for reliable measurement. The measuring system is completely mounted and can be easily installed in the measuring loop. Unique combination of a membrane-free sensor with 2 gold electrodes for long-term stability and easy maintenance • Suitable for measuring free chlorine, chlorine dioxide or ozone. A complete measuring system consists of: MAC 100 Multipara meter signal converter • 1 or 2 sensors • Mounting assemblies Up to two sensors (for identical or different parameters) can be connected to the signal converter. The signal converter MAC 100 can be adapted perfectly for your requirements: you specify the number and type of signal inputs and outputs; you define the complexity of the measuring point and the number of parameters. The standardized user interface also speeds up commissioning of the device and opens access to a wide range of diagnostic functions for devices and processes. The system will also consist of auto manual panel to switch on/off the chlorine pump as per thresholds advised by engineer in charge. The MACH 100 should also be mounted in a weather proof MS panel, Make : DJB Approved | 1 | Job | 12,24,000 ₹14,44,320 Lowest | 12,25,000 ₹14,45,500 |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
16 Jun 2026, 3:00 pmClosed
Executive Engineer (EM) M-1
Chitra Vihar BP Station Laxmi Nagar Delhi-110092
S/I/T/C of C.M. System including all accessories at Mandawali BPS-1
2026_DJB_293121_9
NIT No-07 EE (EM) M-1/ (26-27)
Open Tender
Electrical Works
Works
30 days
Chitra Vihar BP Station Laxmi Nagar Delhi-110092
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
A/c.50448339804
₹29,000
Yes
20 Jun 2026
10 Jun 2026
16 Jun 2026
10 Jun 2026
16 Jun 2026
10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | S/I/T/C of C.M. System including all accessories at Mandawali -1 Booster pumping Station with following works:- SITC of Chlorine Analyzer - Ready to use system for measuring free chlorine, chlorine dioxide or ozone. The measuring system consists of the following devices: MAC 100 Multipara meter signal converter. OPTISENS CL 1100 sensor. The OPTISENS CL 1100 is a single rod sensor with integrated reference electrode. This potentiostatic sensor with 2 gold electrodes is in combination with our signal converter suitable for measuring free chlorine, chlorine dioxide or ozone. In addition to excellent measurement accuracy this leads to a high chemical and mechanical resistance of the electrode and therefore to a long service life with stable measurement performance, The measuring system OPTISYS CL 1100 is already equipped with flow-through cells for temperature sensor and OPTISENS CL 1100 sensor - ASR - Automatic Sensor Cleaning feature for reliable measurement. The measuring system is completely mounted and can be easily installed in the measuring loop. Unique combination of a membrane-free sensor with 2 gold electrodes for long-term stability and easy maintenance • Suitable for measuring free chlorine, chlorine dioxide or ozone. A complete measuring system consists of: MAC 100 Multipara meter signal converter • 1 or 2 sensors • Mounting assemblies Up to two sensors (for identical or different parameters) can be connected to the signal converter. The signal converter MAC 100 can be adapted perfectly for your requirements: you specify the number and type of signal inputs and outputs; you define the complexity of the measuring point and the number of parameters. The standardized user interface also speeds up commissioning of the device and opens access to a wide range of diagnostic functions for devices and processes. The system will also consist of auto manual panel to switch on/off the chlorine pump as per thresholds advised by engineer in charge. The MACH 100 should also be mounted in a weather proof MS panel, Make : DJB Approved | 1 | Job | 80 | ₹80 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
BOQ_389462.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .