Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC NO 6 7 TEACHER RAJAMANICKAM 3RD STREET CHENNAI BANGALORE NH SHENBAKKAM VELLORE 632 008 | VELLORE | TAMIL NADU | 632008 | ₹1.9 Cr | L1 | Accepted-AOC WORK AWARDED |
| 2 | L2₹2.0 CrRejected-AOC ERODE 638 002 | ERODE | TAMIL NADU | 638002 | ₹2.0 Cr | L2 | Rejected-AOC SECOND LOWEST |
| 3 | L3₹2.0 CrRejected-AOC | ₹2.0 Cr | L3 | Rejected-AOC THIRD LOWEST |
| Sl No | Description | Qty | Unit | J K CONSTRUCTIONS L1 | A SURESHKUMAR L3 | R SURESHMANI L2 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling, Clearing away and carefully stacking materials useful for re-use of AC Sheet Roofing without roof timbers etc., complete as directed by the departmental officers. | 1,102.8 | Sq.m | 20 ₹22,056 | 20 ₹22,056 | 20 ₹22,056 |
| 2.00 | Dismantling, Clearing away and carefully stacking materials useful for re-use of One Course of Pressed Tile Roof finish in cement mortar etc., complete as directed by the departmental officers. | 138 | Sq.m | 26 ₹3,588 | 30 ₹4,140 | 30 ₹4,140 |
| 3.00 | Dismantling, Clearing away and carefully stacking materials useful for re-use of Brick / Stone Masonry in cement mortar walls under 3m high etc., complete as directed by the departmental officers. | 3.2 | Cu.m | 300 ₹960 | 320 ₹1,024 | 315 ₹1,008 |
| 4.00 | Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. | 219.99 | Cu.m | 260 ₹57,197.40 | 280 ₹61,597.20 | 270 ₹59,397.30 |
| 5.00 | Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. | 2.2 | Cu.m | 115 ₹253 | 120 ₹264 | 115 ₹253 |
| 6.00 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 40.2 | Cu.m | 2,060 ₹82,812 | 2,150 ₹86,430 | 2,110 ₹84,822 |
| 7.00 | Supplying and filling of conveyed Gravel by lorry in basement filling including stacking for premeasurement, conveyance loading and unloading charges and all other incidential charges and including filling laying watering and consolidating etc., complete as directed by the dept., Officers and complying with standard specification. | 28.5 | Cu.m | 490 ₹13,965 | 510 ₹14,535 | 500 ₹14,250 |
| 8.00 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers. | 14 | Cu.m | 155 ₹2,170 | 170 ₹2,380 | 165 ₹2,310 |
| 9.00 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means | 229 | Cu.m | 5,550 ₹12.7 L | 5,810 ₹13.3 L | 5,695 ₹13.0 L |
| 10.00 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means | 5.5 | Cu.m | 5,550 ₹30,525 | 5,810 ₹31,955 | 5,695 ₹31,322.50 |
Tender Value
₹1.9 Cr
EMD Value
₹1.1 L
Closing Date
3 Sept 2025, 3:00 pmClosed
SUPERINTENDING ENGINEER
O/o. The SE, PWD Buildings C and M Circle, Vellore
Renovation, Refurbishment of Infrastructure and Basic facilities in Government Industrial Training Institute building at Vellore in Vellore District
2025_PWD_598148_1
15/VLR-CLE/25-26-3/12.08.2025
Open Tender
Civil Works - Buildings
210 days
VELLORE IN VELLORE DISTRICT
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1.1 L
14 Jan 2026
30 Aug 2025
3 Sept 2025
30 Aug 2025
3 Sept 2025
30 Aug 2025
Amount
Dismantling, Clearing away and carefully stacking materials useful for re-use of AC Sheet Roofing without roof timbers etc., complete as directed by the departmental officers.
Dismantling, Clearing away and carefully stacking materials useful for re-use of One Course of Pressed Tile Roof finish in cement mortar etc., complete as directed by the departmental officers.
Dismantling, Clearing away and carefully stacking materials useful for re-use of Brick / Stone Masonry in cement mortar walls under 3m high etc., complete as directed by the departmental officers.
Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers.
Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling of conveyed Gravel by lorry in basement filling including stacking for premeasurement, conveyance loading and unloading charges and all other incidential charges and including filling laying watering and consolidating etc., complete as directed by the dept., Officers and complying with standard specification.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
Brick work in Cement Mortar 1:5 (One Cement and Five crushed stone sand) using best quality Burnt Clay Brick of size 9" x 4 3/8" x 2 3/4" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
For Foundation and Basement
Brick work in Cement Mortar 1:6 (One Cement and Six crushed stone sand) using best quality Burnt Clay Brick of size 9" x 4 3/8" x 2 3/4" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
For Foundation and Basement
For Superstructure In Ground Floor
For Superstructure In First Floor
For Superstructure In Second Floor
Brick partition walls of 11.50cm thickness using best quality Burnt Clay Brick of size 9" x 4 3/8" x 2 3/4" with class designation of 7.5 conforming to IS 1077-1992 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
For Superstructure In Ground Floor - 11.50cm thick
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener , side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid).
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and Basement
For Superstructure In Ground Floor
For Foundation and Basement
For Foundation and Basement
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers.
Reinforced cement concrete precast slab 50mm thick using 20mm Jelly
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire)
For Foundation and Basement
For Superstructure In Ground Floor
Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by manual means
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the top of roof with one course of machine pressed tiles of of size 230mm x 230mm x 16 mm to 18mm set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
Paving the floor with best quality Double Charged Vitrified Tiles 600 x 600 x 8mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Flooring with Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing walls with glazed printed design colour glazed tiles of size 300 x 450 x 8mm best approved quality, white / colour glazed tiles conforming to IS 15622 of in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best approved quality fine polished Granite Stone Slabs of Size 1200 x 600 of 18 / 20mm thick and Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., complete complying with standard speicification and as directed by the departmental officers.(The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work)
Plastering the surface of walls with Cement Mortar 1:5 (One cement and Five M-sand), 12mm thick with mortar Plasticizer at 200ml per 50Kg of cement used in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three Plastering Sand (P-Sand) 12mm thick with mortar Plasticizer at 200ml per 50Kg of cement used in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Painting two coats of newly plastered wall surface with ready mixed plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers.
Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers.
Distempering the old wall and ceiling one coat with best oil bound distember of approved quality including preparation of surface, the rate includes cost of brushes, high scaffolding arrangements, neat finishes, etc., complete complying with standard specification and as directed by the departmental officers.
Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting Old wood work with Two coat of synthetic enamel ready mixed paint of approved quality and colour in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying and fixing inposition Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc., The door frame inner shall be packed with CC 1:2:4 using 12mm guage HBG stone jelly including fixing the door frames inposition and dimantling the masonry and concrete wherever necessary and redoing the same original condition after fixing including scaffolding charges and labour charges and door frame will be given one coat of Red Oxide primer etc. Complete complying with standard specification The rate shall inclusive of all materials, labour, transportation, loading, unloading, handling, charges etc. The sample of materials should be got approved by the Exe. Engineer before use on works.
Supplying and fixing Solid Core Flush Shutters with teakply on both side with teakwook lipping alround 35mm thick with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf.
Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames, stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided. 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided 1no. Aldrop is provided at lock rail section in the door 2 Nos of 200mm handle are to be provided. One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf of size 1.00m x 2.10m.
Fabricating, Supplying and fixng in position of steel sheeted windows (Two Leaves) with the following specifications. Outer frames of windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion 'J' section (F4B) of size 46x25x3mm at 2.28kg/m and shutter section of made of F7D of 33x25x3mm at 1.419 kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS Flat at 0.70kg/m at 3 Nos. for each shutter and additional diagonal stiffners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly. 2 numbers of Steel Offset Pivot hingesof size 3" and one number of handle-cum-latch of special type made with 18x5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation. a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. each window shutter having an adustable stay made out of 18 x 5mm at 0.70 kg/ m MS flat of lenght 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 200mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18x5mm at 0.70kg/m, welded to the shutter at two place equivalent from each from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers.All sections should be in confirmed with IS 7452/1990.The cost includes cost of all materials, labour charges and other incidental charges, etc., complete complying with standard specification and as directed by the departmental officers.
Fabricating, Supplying and fixng in position of steel sheeted windows ( Three Leaves) with the following specifications. Outer frames of windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419 kg/ m and mullion 'J' section (F4B) of size 46x25x3mm at 2.28kg/m and shutter section of made of F7D of 33x25x3mm at 1.419 kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS Flat at 0.70kg/m at 3 Nos. for each shutter and additional diagonal stiffners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR Sheets in position firmly. 2 numbers of Steel Offset Pivot hinges of size 3" and one number of handle-cum-latch of special type made with 18x5mm MS flats are revetted to the shutters at an appropriate height in window. suitable opening is left for its easy operation. a stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. each window shutter having an adustable stay made out of 18 x 5mm at 0.70 kg/ m MS flat of lenght 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 200mm length spliced at the ends are welded to the outer frame of the window by using MS flat of 18x5mm at 0.70kg/m, welded to the shutter at two place equivalent from each from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge between them. All members are painted with one coat of anti-corrosive red oxide primer as directed by the departmental officers.All sections should be in confirmed with IS 7452/1990.The cost includes cost of all materials, labour charges and other incidental charges, etc., complete complying with standard specification and as directed by the departmental officers.
Renewing and fixing steel record rack arrangements for height of 2.10 m length of 2.4 m length four rack available including conveyance and transporting charges etc., complete as directed by deparmental officers
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Renewing, Supplying and fixing FRP door frames of size 65x50mm and FRP flush type shutter of over all thickness of shutters 35mm with two core filling eigther with agro based materials or with fiber proof firm in case of light weight and with quality seasoned and treated hard wood cleats wherever found necessary for fixing furniture fittings and with necessary rebate for hinges with colour pigments and casing good quality fiber glass materials G.F. resine thickness of F.R.P. being 3mm with fiber glass matt resin at 1:2 ratio by weight. The sample of materials should be got approved by the Executive Engineer before use on work.
Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section Vertical & Top rail: 50x44.45x2.50mm @ 1.292 kg/m ,Bottom rail: 100 x44.45 x 2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m, Alu Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 Kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - Each., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bush including cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete complying with standard specification and as directed by the deparmental officers. All the Alu. Section are to be anodised with matt finish under electricaly controlled conditions in accordance with IS 1868/1962 for an average anatic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge. (Without Automatic Door closure and Pivot but with hinges)
Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition of size 3.50 x 2.88m. The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 5.5mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes in RCC column,masonry wherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineer before use.
Supplying , fabricating and fixing in position Aluminium Anodised natural colour mat finish Two track sliding window in all floors with Aluminium sections of outer Frame bottom 62x37mmx1.50mm at 1.218 kg/m,the Side & Top 62x31.50x1.50mm at 0.778 kg/m,Shutter Top 40x18x1.5 at 0.38 kg/m,Bottom 40x18x1.5 at 0.38kg/m, Side Vertical 40x18x1.50mm at 0.493 kg/m, Vertical locking section 40x29x1.5mm at 0.632 kg/m, with necessary accessories such as rubber beadings, special hinges, lock, handle including supplying and fixing 4mm thick plain glass including cost of all materials , labours, power consumption required for fabrication , drilling holes in RCC colunm, slab, masonry walls wherever necessary with power drills to the required extent and make good to the original condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers.The aluminium sections are to be anodised with matt finish under electrically controlled in accordance with IS 1868 / 1962 for an average anodic film thickness 15 microns etc., complete.
Manufacturing Supplying and fixing in position of Aluminium anodized natural colour matt finish openable type glazed ventilator of 900 mmx600mm with extruded Aluminium section of Outer frame H-section 37.70x33x2mm @ 0.50kg/m,Shutter Z- section 21/24.50x33x2.50mm @ 0.525 Kg/m and the with 4 mm thick glass with necessary accessories such as rubber beading best quality of lock handle and fixing wherever necessary with power drill to the extent required and mae good to the original conditions after fixing etc... complete complying with standard specification and as directed by the deparmental officers. The Aluminium surfaces is to be anodized with matt finish is to be anodoized with matt finish used electrically condition in accordance with ISI 1868/1962 specification for an average anodic film thick of not less than 15microns. All sections and furniture fittings should be got approved by Executive Engineer incharge.
Renewing and fixing in position of M.S. Weldmesh enclosure using Country wood scantling upto 4 M long with 1" x 1" - 10 gauge weld mesh fixid regidly with country wood frame including dismantling, redoing to the original condition etc., complete complying with standard specification. The sample of weldmesh should be got approved by the Engineer incharge before use on works.
Renewing and fixing in position of M.S. Weldmesh parition using outer frame made out of MS L angle of size 50x50x6mm long with intermediate supported at MS flat of size 40x 5mm and fixing 1" x 1" - 10 gauge weld mesh fixid regidly with country wood frame including dismantling, redoing to the original condition etc., complete complying with standard specification. The sample of weldmesh should be approved by the Engineer incharge before use on works.
Supplying and fixing of Mild Steel Grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
Renewing and Fixing the glass pans of 5 mm thick for doors, windows and ventilators with teak wood beading of size 15x12mm etc. complete complying with standard specificataion.
Supplying fixing and errecting of steel roof trusses and roof truss purlins fixing for G.I. sheet roofing using MS. L. angle of size 50x50x6 mm raffter, Tie angles and MS angle of size 50x50x6mm for sturts and MS plat of size 12 mm thick for fixing G.I. sheet. The purlins using MS L. angle of size 50x50x6 mm shall be properly anchored to the supporting super structure and fixed in concrete at wall and spacing of purlins are to be arranged to use the standard size or sheet and spacing should not execeed 1680 mm and free over hang at eves should not be more than 400 mm, the cleats shall be wellded to the trusses firmly and fixed on the down stream side of purlins. The ridge purlins fixed at 77 to 115 mm away the apex of the roof. The trusses shall have welded joints only at all guessets plate junctions except gussets at bottom chords to have bolts and nuts to permit transportation of trusses as directed. The foundation anchor bolts of trusses will be fixed in concrete at wall in bed blocks and well cured, labour for erection of trusses of approved quality transportation, priming coat for all members, cutting, bending, and welding etc., The trusses should be connected at bottom 1 / 3 part by steel tie angles and with top and bottom wind bracings as per design given. The chord of the trusses of bottom channel should suitablely cambered. The truss and purlins should be given priming coat of Rex Oxide primer of approved quality including labour for erection, transportation, wellding etc., complete complying with standard specification.
Supply and installation of Anutone (or) Equivalent Brand of Acoustical False Ceiling of Sisoli Serene / Slate Spirts / Slate Polka Mineral Fibre/ GRG Core Ceiling Tiles of size 595 x 595 x 15mm having volume density 270 kgs / m3, weight 4kg / m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. The skelet trelis T15 metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angle with unequal flanges of 15 / 19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally skelet CT15 W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15 W12 CrossT in direction parallel to the Main T15 to result in 600 x 600mm module. Sisoli Serene / Slate Spirts / Slate Polka of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. The systems to achieve noise reduction coefficient not less than 0.5 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, Scaffolding, transportation, conveyance, etc., complying to standard specication.
Renewing and fixing the best quality and approved variety of GYB-BOARD cornice work including labour charges for fixing etc.,complete and as directed by the departmental officers.
Renewing and fixing the best quality and approved vareity ISI mark vertical blinds including labour charges for fixing etc., complet as directed by the departmental officers.
Renewing and fixing of rolling shutters shall be pull and push type made of 18/Gx3" lath sections which consist of five main parts such as curtain, lock plate, guide channels rollers and hood cover. These five main parts are made out of special components detailed below:Curtain shall be of 18/Gx3" lath sections cut to required size and filled with heavy cast iron / MS clips. For 8' 0" (2.45m) high rolling shutter lath sections provided shall be not less than 37 numbers. Lock plate shall be of 10 GMS sheet reinforced with 40mm x 6mm MS angles at the bottom and fitted with heavy latches and locking arrangements on either sides. There should be one handle on either sides. Guide channel pressed guide channels shall be 10GMS sheet and attached to the side brackets with 20mm square bar. Side brackets shall be of 10G MS plate and cast iron "U" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty "C" class 40mm steel pipe and high tensile high carbon coil springs. 2 springs shall be supplied. Side brackets shall be of 10G MS plate and cast iron "U" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty "C" class 40mm steel pipe and high tensile high carbon coil springs - 2 springs shall be supplied. Hood cover shall be of 0.8mm CRCA sheet reinforced with 25mm x 25mm x 3 mm MS angle or gate channel. The rolling shutter in addition to the above should have pulling hook and shall be coated on exposed area with heavy coat of red oxide primer.
Renewing and fixing of roofing with colour galvalume sheet of 0.47mm thick with all necessary accessories such as J/V bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers.
Water proofing to RCC slab: Basic cleaning of the surface to remove dirt, dust, loose particles, Providing and applying a single coat of bitumen emulsion primer and allow it to dry. Providing and laying 3mm thick app modified polyester bitumen membrane over the entire primer substrate by torch shield method, sealing all overlaps and joints, completing it as per standard procedure. Waterponding test. After checking for leakage, providing a coat of emulsion for mechanical bonding.
Renewing and fixing 2ply four fprongled GI barbed wire fencing using 10 guage of best quality of GI barbed wire typing with GI binding wire including charges for fixing etc., complete and as directed by the departmental officers.
Supplying and erection of Cut Stone pillar of size 0.15x0.15x2.10m hight including transportation, Labour charges and tying and binding charges etc., complete and as directed by the departmental officers.
Supplying and fixing the Chain Link - 2" x 2" using 10 Gauge Galvanised Iron Wire (of all sizes) inculding fixing charges etc., complete and as directed by the departmental officers.
Supplying and Fixing of Aluminium Dye Cast Letters of 9’’ size and colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process.
Providing and Fixing of Brass Tamil Nadu Government Emblem of size 45cm (15") dia in position of best quality special approved variety for name board including moulding, grinding and neatly finishing to all edges to letter conveyance charges bolts and nuts, paste and scaffolding charges the same in position etc., complete.
Supplying and fixing in position best approved of BIS quality 110mm dia PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers
Supplying, laying and jointing UPVC pipes of Class 5 (having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level.
40mm dia UPVC pipe
25mm dia UPVC pipe
20mm dia UPVC pipe
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
110mm dia PVC soil / waste pipe
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
25mm dia Gun Metal Gate Valve
20mm dia Gun Metal Gate Valve
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Renewing and fixing in position 15mm dia brass CP Screw Down Tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supplying and fixing 40mm dia CPVC pipe for sub-mergible pump in Bore of best approved quality including welding wherever necessary etc., complete as directed by the Executive Engineer. The pipe should be got approved by the Executive Engineer before use on works.
Supplying and tying of Nylon rope of 15mm dia thread make with best quality of Nylon rope etc., complete as directed by the Executive Engineer. The Rope should be got approved by the Executive Engineer before use on works.
Supplying, Fixing and connecting of 2x32 sq.mm seathed cable wire for the sub-mergible motor from pannel board to sub-mergible pump.
Supplying and fixing 5 HP / 3 Phase, 9 Stage sub mergible pump of approved make and quality with ISI mark with necessary accssories and fixed with delivery pipe errected in the borewell with necessary clamp etc., with following additional accssories 1 No of 3 Phase Star Delta Starter of 63 AMPS of approved quality and make with ISI mark 1 No of 3 Phase 63 AMPS Main Switch of approved quality and make with ISI mark. 1 No of priventor of approved quality and make with ISI mark 1 No of pannel board of required size with indicator fuse unit voltmeter with necessary provision toaccomodate the starter and mini starter etc. 1 No of capacitor with board as per standards of TNEB
R SURESHMANI (BID ID -1445909)
A SURESHKUMAR (BID ID -1445683)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB