Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC 60 4 MOTILAL GUPTA ROAD GROUND FLOOR KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹35.5 L+₹3.5 L (11.1%)Rejected-Finance 2 BAISHNAB SETH 1ST LANE KOLKATA 700006 | KOLKATA | WEST BENGAL | 700006 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹35.8 L+₹3.8 L (11.9%)Rejected-Finance 89A UPEN BANERJEE ROAD PARNASREE BEHALA KOLATA 700060 WEST BENGAL | KOLKATA | WEST BENGAL | 700060 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹36.0 L+₹4.0 L (12.4%)Rejected-Finance 20 1 B M BANERJEE ROAD BELGHARIA KOLKATA 700056 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹36.3 L+₹4.3 L (13.4%)Rejected-Finance 0 GANGARAM DHARMKANTA TRUCK UNION JIROTA KALAN DAUSA DAUSA RAJASTHAN 303303 | DAUSA | RAJASTHAN | 303303 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
21 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ MAINT OF HOT WATER APPARATUS ALONGWITH ANCILLARY ITEMS AT DIFFERENT OTM ACCNS INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2024_MES_691150_1
8324/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer (FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (FW) Kolkata
₹59,000
Yes
5 Apr 2025
31 Dec 2024
22 Jan 2025
31 Dec 2024
21 Jan 2025
14 Jan 2025
Amount
Taking down geysers any type and capacity (25/50 ltrs) from the existing position in wall and removing to stores for repairs, cleaning and re-fixing the same in original position after repairing including electric and water connection, testing etc complete.all as specified and directed. ( Note : Repairs of item shall be measured and paid separately under relevent item).
Supply and fixing in repair copper heating element tubular steel type element 1500/2000W (ISI Marked) suitable for 25ltrs capacity as per sample after removing the existing defective element complete.all as specified and directed.
Supply and fixing in repair Porcelin heating element 1500/2000W (ISI Marked) suitable for 25ltrs capacity as per sample after removing the existing defective element complete.all as specified and directed.
Supply and fixing in repair thermostat switch ISI marked for geysers of 25-50 ltrscapcity of micro gap steam type thermostat SEA and make as per sample approved GE, including testing complete.all as specified and directed.
Supply and fixing in repair thermostat switch ISI marked for geysers of 25-50 ltrscapcity of micro gap steam type thermostat TSE and make as per sample approved GE, including testing complete.all as specified and directed.
Supply and fixing in repair thermal cut switch ISI marked for geysers of 25-50 ltrs capcity, make as per sample approved GE, including testing complete.all as specified and directed.
Supply and fixing in repair thermostat auto cut off switch ISI marked for geysers of 25-50 ltrs capcity, make as per sample approved GE, including testing complete.all as specified and directed.
Supply and fixing in repair brass apprature plate complete with pluger pipe, bolts, nuts, and rubber ring complete and all connected components for 25 ltrs capacity geysers including testing approved GE, including testing complete.all as specified and directed.
Supply and fixing in repair split plate of 22 SWG MS sheet white stove enamelled suitable for bottom cover of 25 ltrs capacity geysers testing complete all as per sample specified and directed .
Supply and fixing in repair high density polythene pipe heavy duty confirming to IS 3075, 15mm dia, 600mm long, including brass coupling at each end (weighting not less than 40gms each) one end secured to inlet of geysers and other end to stop cock all complete with connection complete.all as specified and directed.
Supply and fix in repair 20Amp Metal clad socket 3 pin (2P+E), complete.all as specified and directed. Make : L&T cat No MPS220S or equivalent make specified in tender.
Supply and fix in repair 20Amp Metal clad Plug 3 pin (2P+E), complete.all as specified and directed. Make : L&T cat No MPS220S or equivalent make specified in tender.
Supply and fixing of rubber/PVC gasket to ensure water tightness of 25 Ltr geyser suitable as per sample complete.all as specified and directed.
Supply & Fixing in repairs Air release valve/dead weight Valve ISI mark suitable for 25 Ltr cap geyser complete.all as specified and directed.
Supply & fixing in repairs Non return Valve brass of 15 mm bore after dismantling old unserviceable NRV of any size all complete.all as specified and directed.
Supply and fixing glass wool (spl quality) at thermal insulation after removing the old glass wool in between the inner container and outer casing complete.all as specified and directed.
Supply and fixing pilot lamps round noon indicator for suitable for 25 ltrs capacity geyser fitted on the unit including necessary electric connection, testing complete including taking out old defective indicator complete.all as specified and directed.
Supply and fixing for replacement of SS Flexible connecting pipe of size 15mm dia, 600mm long with brass coupling and union at both ends heavy duty suitable for fix on 15mm dia GI pipe with washer complete and all as directed at site after takingout unserviceable one complete.all as specified and directed.
Scraping, cleaning/removing deposited scales, connecting cavities as required for copper vessel outside surface, MS outer shell with top and bottom cover both surface shall be painted with two coat of synthetic enamel paint on outer surface of shell, top and bottom cover shall be painted with two coats of synthetic enemalled paint over a coat of red oxide zinc chrome primer and one coat of of red oxide to copper vessel outer surfaces and inner surface of outer shall geyser of any size 25/50 ltrs capacity and numbering/marking with different paint complete.all as specified and directed.
Repairing leak portion of inner tank of geyser of any type/capacity by mean of spot welding with slider/brass spot braising and testing complete (Nos of spot welding not exceeding 5) complete.all as specified and directed.
Supply and fixing bolts and nuts and washer 15mm dia 75mm to 100mm long with cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregate) incluing taking out old fixing bolt(set of four) from walls complete.all as specified and directed.
S&F Mild steel clamp of flat iron of size (25X6mm ) made to shape 100mm long welded with outer casing of geyser to walls with bolts and nuts complete.all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 15 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete.all as specified and directed.
S&F metal clad box enclosure with socket plugtop and MCB SP 20 Amp flush mounting enclosure with 2 pin earth plug socket complete.all as specified and directed.
S&F in repair copper inner tank for hard and soft water pressure upto 100PSI (7.00Kg/Cm2) and normal working pressure is 30 PSI(2.11Kg/Cm2) for 25ltrs after removing the existing defective tank complete.all as specified and directed.
Supply and fixing in repair stainless steel inner tank for hard and soft water pressure upto 100PSI (7.00Kg/Cm2) and normal working pressure is 30 PSI(2.11Kg/Cm2) for 25ltrs after removing the existing defective tank complete.all as specified and directed.
Supply and fixing in repair mild steel outer cover 22 SWG for 25 ltrs capacity any dia of geyser including bottom and top cover with MS clamp, outer ring and split pin including two coats of paint over one coat of red oxide primer including dismantling the unserviceable cover as per direction by the Engineer-in-Charge.
S&F in repair metal clad single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amp,240 Volt,complete.all as specified and directed.
S&F insulated workshop type 3 core flexible wire of size 24/0.20 complete including taking down old flexible unserviceable wire complete.all as specified and directed.
Supply & fixing in repairs stop valves of 15mm size, cast copper alloy, screwed down, high pressure with crunch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete.all as specified and directed.
Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc.complete all as specified and as directed .
Materials and Labour for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (a) One light point or one fan point or bell point controlled by one switch or bell push
All as per item No 32 above but for one 5amp switch socket combination on independent board,complete all as specified and directed (surface type point wiring with terminal box)
All as per item No 32 above but for one 5amp switch socket combination on same board,complete all as specified and directed (surface type point wiring with terminal box)
All as per item No.32 above but using 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 1.5 sqmm green FRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 32 above but using 4 sqmm single core multi stranded copper conductor FRLS PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 4.5 sqmm green FRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
M&L for replacement of sub main wiring with 2 run of 6 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable FRLS working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including heavy duty rigid non-metallic PVC casing/caping (25mm dia) including size 6 sqmm (nominal cross sectional area) PVC insulated un-sheathed single core multi stranded copper conductor cable as earth continuity conductor connected to main switches/DB"S or common earth dully complete all as specified and directed after taking down old sub main wiring complete and making good the disturbed surface.( NOTE :- Two runs of 6 Sqmm pvc wire, one run of 10 Sqmm pvc wire and one run of pvc casing caping/ PVC conduit will be measured as one unit)
M & L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through & including PVC conduit of suitable size in Surface/concealed all as directed.
S & F Chromium plated brass angular stop cock concealed with wall flange fixed to 15 mm bore of iron pipe as in repair etc complete all as specified and as directed.
S&Fin repair plug Top 3 pin 15/16 Amp AC 230 Volts complete all as specified and directed
S&F Rotatary switch for slection of temparture for Geyser of capacity 25litrs AC 230 Volts complete all as specified and directed
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
MARUTI ENTERPRISES (BID ID -3220192)
M/S AVIJEET INTERNATIONAL (BID ID -3220343)
GOODWILL AND CO. (BID ID -3216748)
Shanti Construction Company (BID ID -3219752)
MAZUMDER ENTERPRISE (BID ID -3220295)
Piu Projects (BID ID -3218907)
ARMOUR UNIT (BID ID -3220238)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .