Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹35.4 L+₹1.8 L (5.49%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹39.3 L+₹5.7 L (17.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹49.2 L+₹15.6 L (46.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹49.4 L
EMD Value
₹98,800
Closing Date
28 Jan 2020, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT
REPAIR TO CERTAIN OF B/R AND E/M WORK FOR E/M INSTALLATION AT BASE HOSPITAL UNDER GE E/M BASE HOSPITAL DELHI CANTT-10
2019_MES_310823_1
GE/BH-50/2019-20
Open Tender
Civil Works
Item Rate
180 days
GE E/M BASE HOSP DELHI CANTT
Meeting enlistment criteria of MES with regard to having satisfactory completed requisite value works annual turnover, working capital, fixed assets. No recovery outstanding in any govt dept security clearance etc.
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹98,800
Yes
17 Mar 2020
31 Dec 2019
30 Jan 2020
1 Jan 2020
28 Jan 2020
14 Jan 2020
Amount
Dismantling of brick tiles or terracing tiles, single layer on roofs complete all as specified & as directed.
Demolition of Mud in roofs, any thickness, including PCC/plastering and leeping complete and removing the spoil to a distance exc 250 m but n exc 500 m complete all as specified and as directed.
M&L for providing plain cement concrete, type B-1, 1:2:4 (using 12.5 mm graded stone aggregate) as in roof padding, Gola, etc including cleaning the surface by wire brushing complete all as specified and as directed.
M&L for 20 mm thick rendering on concrete surface of roof with cement mortar 1:4 finished even and fair including mixing of water proofing compound as per manufacturers instruction complete all as specified and as directed. (Note : Water proofing compound shall be measured and paid separately)
Supply only water proofing compound (powder)complete all as specified & as directed.
M&L for roof treatment with polymeric membrance (APP based) with non woven polyster mat as reinforcement with following:- (a) M&L for cleaning the new plastered surface and providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.30 Ltr/Sqm on dry and clean surface. (b) M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight of 3.0 Kg/Sqm with non woven polyster fibre as reinforcement on primed surface by torch application with 15 cm end over laps & 10 cm side over laps etc as per manufacturers instruction. (Make:- IWL India Ltd, STP Ltd and Torch Tar Membrane) (c) M&L for finishing of top surface by a coat of aluminium paint complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc. including raking out of joints, hacking for key, scrubbing down with water etc. any description complete all as specified & as directed
M&L rendering 15mm thick in Cement Mortar 1:6 on fair faces of brick or concrete, external surfaces of walls finished the surface fair and even without using extra cement complete all as specified & as directed.
M&L rendering 15mm thick in Cement Mortar 1:4 on other than fair faces of brick surfaces of walls finished the surface fair and even without using extra cement complete all as specified & as directed.
M&L 10 mm thick plastering in Cement Mortar 1:4 finished even and smooth w/o using extra cement on brick surface of ceilings complete all as specified & as directed.
M&L for preparation of new surfaces of walls plastered or unplastered and applying two coats of cement base paint over a coat of primer to walls to obtain uniform surfaces including making good the surface complete all as specified & directed.
M&L for preparation of new wall surface including chalk whiting, on plastered surfaces, preparatory to distempering and applying for two coat of oil bound distemper over a coat a coat of 2 to 3 thick wall care putty all as specified and as directed
M&L for preparation of new plastered or unplastered wall surfaces and applying three coats of white wash on ceiling complete all as specified & as directed.
M & L for preparing the old decorated wall surface by brooming and removing all loose layers of old treatment, efflorescence , soot and moss by wire brush and filling all nail holes and patches with cement wall putty and applying one or more coat of lime wash white on patches to bring the whole surface at par and applying one coat of lime wash white on walls all as specified and as directed.
M & L for preparing the old distempered surface of wall surface by washing down and rubbing and removing all loose layers of old treatment, efflorescence , soot and moss by wire brush and filling all nail holes and patches with cement wall putty and applying one or more coat of oil bound distemper on patches to bring the whole surface at par and applying one coat of oil bound distemper on walls all as specified and as directed.
M&L for preparing the old painted wooden surfaces of any description exc 10cm width or girth by removing all dirt, dust, rust and grease, stopping and filling the holes and patches and priming the requisite surface with pink primer incl. applying one coat of synthetic enamel paint on patches and then applying one coat of synthetic enamel paint all as per 17.3 of SSR part-I 2009 complete all as specified and as directed.
M&L for preparing the old painted steel surfaces of any description exc 10cm width or girth by removing all dirt, dust, rust and grease, stopping and filling the holes and patches and priming the requisite surface with red oxide/Zinc chrome primer incl. applying one coat of synthetic enamel paint on patches and then applying one coat of synthetic enamel paint all as per 17.3 of SSR part-I 2009 complete all as specified and as directed.
M & L for complete removal of existing treatment from old decorated wall surface by scrapping and filling all patches with cement wall putty and applying one or more coat of Cement paint on patches to bring the whole at par and applying two coat of Cement paint on walls all as specified and as directed
Taking down unserviceable steel door/ window frame /shutter and make it serviceable by repair/ replacing with new 50mm MS box type hinges, handle, pegstays, complete glass panes & locking arrangement at any position with necessary welding work complete, and refixing the same to make window smooth functioning and making good plaster work around the window complete all as specified and directed. including hinges, steel handle, MS Peg stay and locking arrangement for steel windows, etc complete all as specified and as directed
Dismantling timber scantling in fillet, rail post, rafter, purlin etc under 40 Sqm in section in any position unframed work complete all as specified and directed.
Dismantling post & struts (wood, steel, RCC) any section including taking out embedded portion and making good disturbed ground post embedded in concrete complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layer not exc 25cm in soft/ loose soil including PCC complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
S&F Steel work in tubular trusses/Posts/Rafters/Purlins, etc including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS- 1161-1979 gde SI-240 complete all as specified and directed.
S & F plain MS plate incl cutting / welding & drilling complete all as specified and directed.
Dismantling AC corrugated/semi-corrugated sheets in roof coverings incl ridges complete all as specified and directed.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling wall ceiling boards (Fibre pulp. Insulation, AC boards, wooden boards etc) or insulation boards/slabs/composite panel, etc any thickness including cover fillets and ceiling frame work including disposal of all debris exc 1.5 KMtr not exc 5 Km and complete all as specified & as directed.
M& L for GI anodised snap grid ceiling made of Tee and angle of size 24.5 x 24.5 x1.50 mm thick, size of grid 605 x 605 mm with GI wire suspender 2 to 3 mm dia fixed with wooden/steel truss/rafter flat or slope including taking down old ceiling complete all as specified and as directed.
M&L for 4 mm thick E-board (designer)classic of size 595 x 595 mm, fixed to GI snap grid ceiling flat or slope complete all as specified and as directed.
Demolition of brick work built in cement mortar of any description and including disposal of all debris exc 1.5 KMtr not exc 5 Km and complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius in CM 1:6 complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed.
Demolition of stone slabs laid bedded and pointed in any mortar and cladding tiles of any description or thickness in floors, aprons, walls, etc and removing the debris off MOD land complete all as specified and as directed.
M&L 20-25 mm thick machine cut kota stone flooring laid over and including screed bed or bedding layer mortar 15mm thick in cement mortar 1:6 for laying floor finished jointed and pointed with grey cement slurry mixed with pigments to match the shads incl rubbing and polishing upto mirror image complete all as specified and as directed.
M&L 20 - 25 mm thick machine cut kota stone in riser of steps, skirting/dado and pillar laid over 10 mm thick rendering coat in cement mortar 1:3 complete all as specified and as directed.
M&L for grinding and polishing of existing kota / Flooring and filling joints all as specified and as directed.
Demolition of cement concrete in ground floors and paving not exc 15cm thickness( below or above ground level) .including disposal of all debris exc 1.5 KMtr not exc 5 Km and complete all as specified and as directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M & L PCC 1:3:6 type C1, (using 20mm graded stone aggregate) as in surface channels and drains complete all as specified and as directed.
M&L 25 mm thick PCC 1:3:6 Type C2 (using 20 mm graded stone aggregate) below tiles for levelling of existing surface, mass concrete, etc complete all as specified and as directed.
Supply and laying sand (25 to 30 mm thickness ) for cushioning to interlocking paver block complete all as specified and as directed.
M&L for vibrator compacted rubber/glass moulded precast concrete interlocking paver block shape, size and colour as approved confirming to IS 15658-2006 of 60 mm thickness M-35 Grade made with grey cement and pigment complete all as specified and as directed. (Make : Terra Firma, A-One tiles, Coral, Mehtab Tiles, Hindustan Tiles)
M&L for 50 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floorings, including finishing the surface even and smooth using extra cement complete all as specified and as directed.
M&L 3mm thick, 38mm wide glass dividing strips inserted in position to conform to design complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 (40mm graded aggregate) as in plinth protection/hard standing and finished the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for applying one coat of apex (thick red) in (match with Existing) chequered floor, cleaning by wire brushes including removing dust, dirt, moss etc and washing down with water complete all as directed and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and including disposal of all debris exc 1.5 KMtr not exc 5 Km and complete all as specified and as directed
M&L for 7mm to 8mm thick Its quality ceramic non skid tiles coloured of area exec 0.11 Sam but not exec 0.18 Sam (400x400mm) in flooring set and jointed in neat cement slurry and pointed in coloured cement to match with tiles laid on 15mm thick cement screed (1:4). all as specified and directed Make: Katarina/Johnson/Soma nay
M&L for glazed ceramic tiles Ist quality in vertical surface 600x300x7mm thick or any other large size as required, laid over 10 m thick screed plaster in CM 1:4 at site to match the existing tiles set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of existing tiles complete all as specified and directed Make: Kajaria/Johnson/somany
S&F of steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staples and one shop coat of primer, erected in position incl welding as indicated complete push, pull or manual type thickness of flap 1.25mm including taking down of rolling shutter complete all as specified and as directed (Make: Swastic/ Hercules/M/S Prakash Industries/ M/S Bharat rolling Shutters Industries Jabalpur
Taking down and refixing (same opening) of steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staples and one shop coat of primer, erected in position incl welding as indicated complete push, pull or manual any type thickness complete all as specified and as directed
Taking down chowkhat or frames (without taking off shutter from the frame) not exc 1.50 sqm each complete all as specified and as directed.
All as per item No 54 above but exc 1.50 sqm but not exc 4.00 sqm complete all as specified and directed.
S&F solid PVC moulded door frame of size, 50x47mm, made out of 5mm thick plain colour PVC sheet, reinforced with MS square tube fixed with screw/plugs to brick walls complete all as specified and directed.
S&F Factory made solid panel PVC moulded door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails either suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing incl 3 Nos 100mm PTMT Hinge, 2 Nos 150 mm PTMT Tower bolt and 2 Nos 150 mm PTMT handle complete all as specified and directed.
Taking down steel window (without taking off shutter from the frame) not exc 1.50 sqm each complete all as specified and as directed.
S&F of steel window with side hung shutters including projecting type hinges with steel handle, and steel peg stay complete with glazing bars, glass panes and dovetailed or welded complete all as specified and as directed. Make: Metal window Corps new Delhi/ Govind Enterprises Delhi/ Chandni Industries Ghaziabad
S&F angle, channel or tee sections fixed independently and prepare by welding door frame complete all as specified and directed.
S&F of steel door frame with MS sheets complete including projecting type hinges, steel, handle, complete with glazing bars, dovetailed or welded. complete all as specified and directed. Make: Metal window Corps new Delhi/ Govind Enterprises Delhi/ Chandni Industries Ghaziabad
S & F flush shutters 35mm thick, solid core construction, with block board core and ply wood face panels, commercial type on both sides complete al as specified and as directed Make: M/S Laxmi doors faizabad road Chinhat Lko/Jain wood ind sonepat brand( Jayna)/ Northern Doors Kanpur
Supply and fixing windows of powder coated aluminium section two track with two sliding shutters with following sections : (a) Frame section shall be 63.50 mmx38.10 mmx2 mm thick. (b) Two track bottom rail for sliding of shutters 61.85mm x 31.75mmx2mm thick. (c) Two track top section shall be 61.85mmx31.75mmx2mm thick(d) for sliding shutter handle& 'H' bottom section should be 40mmx(18mm+9)mmx1.45mm thick(e) sliding shutter to be provided with 5.5mm thick sheet glass( Modi/Saint gobain/tinted, plain, frosted (f) stainless steel wire clothes 0.36mm nominal dia of wire and average width of aperature 1.40mm complete all as specified and as directed Make: Jindal/Hindalco/Balco
M&L for powder coated aluminium window and ventilator shutters, sliding type with or without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays/lock, Rollers, hinges type B-21 100mm long (2 no.) suitable handle (1 no per shutter) complete all as specified and as directed.
S&F aluminium powder coated door frame with partially glazed shutters single/ double leaf divided into two glazed panels including aluminium anodised snap beading and rubber gasket/lining for fixing of glass as directed. The frame shall be fixed with aluminium anodised bolt by drilling in the existing wall and with thrust bolt of suitable size all as directed. The frame and shutter will be made out of the following section and fitting a) Aluminium anodised door frame 101.60 mm x 44.75 mmx2mm fixed with aluminium thrust bolt in walls by drilling as directed. b) Aluminium anodised sides rail of shutter section 83.5mmx 44.5mm x 2mm c) Aluminium anodised bottom rail of shutter section 150mm x 44.5 mm x2mm. d) Aluminium anodised top and middle rail of shutter section 100mm x 44.5 mm x 2mm. e) Aluminium anodised tower bolt 200 mm long - 02 Nos in each leaf of Make Classic/Argent as approved. f) Aluminium anodised handle 250 mm long of approved Make Classic/Argent 02. No’s in each leaf. h) Glass Pane shall be 5.5 mm thick tinted glass. j) 12mm thick prelaminated particle board laminated both side exterior grade complete all as specified and directed Make- JINDAL/HINDALCO/BALCO.
S&F 300mm long mild steel sliding door bolt, stove enamelled black with bright belt not less than 12mm dia with and incl a minimum of 6 belts and nuts four on belt plate and two on staple plate complete all as specified and directed.
S&F 200mm long Aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F 150mm long Aluminium handles, cast type anodised complete all as specified and directed.
S&F 100mm long MS butt hinges medium weight cold rolled mild steel complete all as specified and directed.
Cutting holes in brick walls (exc half brick but not exc one brick) built in cement mortar for inserting hold fast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed.
S&F MS work as in hold fasts, bands supports, clamps, wall ties hooks incl nut and bolts etc conforming to Fe-410-0 or Fe-310-0 including welding etc complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connections including clfor refixing or removal to store complete all as specified and directed.
S&F 15mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches.complete all as specified and directed.
Refixing 15 mm bore old steel tubing and conncetions in new or old position to walls complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connections including cleaning or refixing or removal to store complete all as specified and directed.
S&F 20 mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenchescomplete all as specified and directed.
Refixing 20 mm bore old steel tubing and conncetions in new or old position to walls complete all as specified and directed.
Dismantling of CI soil,PVC (any type) rain water pipes, cast and vent pipes of any dia, any pattern including all fittings complete all as specified and directed.
S&F PVC (SWR) pipes single socketed 110 mm bore in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 100 mm dia sand cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls with stack clamps or laid in floors incl taking down old one complete all as specified and directed.
S&F 75 mm dia sand cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls with stack clamps or laid in trenches or in floors including taking down old one complete all as specified and as directed.
S&F in repairs 75 mm dia cast iron floor trap including joints, etc complete all as specified and as directed.
S&F in repairs 100 mm dia cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.
S&F in repairs 100 mm dia cast iron branch pieces,single (equal or unequal) Tee, sockets, etc with oval access door if required and fitted with stack clamps, etc complete all as specified and as directed.
Supply and fixing in repair vitreous China squatting pan, "Orissa" pattern size 580 X 440 mm, white, (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, etc and complete all as specified and as directed.
S & F in repairs 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve, float, chain and pull and brackets etc complete all as specified and as directed. (Make: Hindware /Parryware /Cera /Commander)
S & F in repairs 15mm dia bib tap, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specifed and as directed
S&F in repair 15 mm dia stop valve external threaded,cast coppper alloy ,screwed down high pressure with crutch or butterfly handle ,screwed both ends for iron pipe or for uninos complete all as specified and as directed.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
Hacking out old broken glass (any thickness, size quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed.
S & F sheet glass 3mm thick ordinary quality and glazing with oil putty/wooden beads in squares n exc 0.50 Sqm in each pane complete all as specified and as directed.
S & F 3mm thick figured glass, pin head glazing with oil putty /wooden beads in squares n exc 0.50 Sqm in each pane complete all as specified and as directed.
Extra for forming fair finishing drain or channels 30 cm inner girth in cement concrete using extra cement including forms, moulds stopped ends etc. complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc to be measured separately) and making good disturbed surfaces of wall floor etc complete all as specified and directed.
Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and directed.
M&L point wiring for normal switches with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through concealed Conduit as requirement of site including cadmium plated screws as per ISI, including replacement of 3 mm thick phenolic laminated sheet top covers on and including sunk type CI/steel terminal boxes concealed in wall including 1.5 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light point controlled by one switch 5 Amps one way single polecomplete all as specified and directed.Make-Havells/Finolex/Standard.
All as per item No. 96 above but one fan point controlled by one switch 5 Amps one way single pole.
All as per item No. 96 above but one three pin 5 Amps socket out let on independent board.
All as per item No. 96 above but one three pin 5 Amps socket out let on same board.
All as per item No. 96 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed. Make-Havells/Standard /Finolex
All as per item No. 96 above but point wiring of copper cable multi stranded 4.00 Sqmm size for AC point wiring with 4.0 Sqmm size of earth conductor complete all as specified and directed.Make-Havells/Standard/Finolex
M&L point wiring for normal switches with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through casing & caping as requirement of site including cadmium plated screws as per ISI, including replacement of 3 mm thick phenolic laminated sheet top covers including 1.5 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light point controlled by one switch 5 Amps one way single polecomplete all as specified and directed.Make-Havells/Finolex/Standard.
All as per item No. 102 here in before but one fan point controlled by one switch 5 Amps one way single pole.
All as per item No. 102 above but one three pin 5 Amps socket out let on independent board.
All as per item No. 102 above but one three pin 5 Amps socket out let on same board.
All as per item No. 102 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 6 Amp/16 Amps multipurpose socket outlet on independent board with 1.5 Sqmm size of earth conductor complete all as specified and directed.Make-Havells/Standard /Finolex/ Anchor/Cona
All as per item No. 102 above but point wiring of copper cable multi stranded 4.00 Sqmm size for AC point wiring with 4.0 Sqmm size of earth conductor complete all as specified and directed.Make-Havells/Standard/Finolex/ Anchor/Cona
Supply and fix in repair Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete.Make :- Anchor, Cona, Legrand
Supply and fix in repair Switch socket combination white polycarbonate body, 6A / 16A- 230 V, Multipurpose, including connecting complete.Make :- Anchor, Cona, Legrand
Supply and fix in repair Switch socket combination white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete. Make :- Anchor, Cona, Legrand
Supply and fix in repair stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete.Make :- Anchor, Cona, Legrand
S&F in repair sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps , 240 Volts complete all as specified and directed. Make:-Legrand/seimens/ schneider.
M & L Sub main wiring using two single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit. Note Two runs of 4sqmm copper FRLS cable & one run of 4.0 sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit.
M & L Sub main wiring using two single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit. Note Two runs of 6 sqmm copper FRLS cable & one run of 6.0 sqmm copper cable in and including 25mm PVC conduit medium grade will be measured as one unit.
M & L submain wiring using four run PVC insulated FRLS Copper conductor 10 sqmm with rigid non metalic PVC conduit of size 32 mm dia medium grade inclusive of boxes (junction/terminal) all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with saddles PVC with earth continuity wire copper conductor PVC insulated unsheathed 10 Sq mm etc.Note four runs of 10 sqmm copper FRLS cable & one run of 10 sqmm copper cable in and including 32 mm PVC conduit medium grade will be measured as one unit.
S & F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN 8 way with 250 Amps rated copper bus bar, 415 Volts with in built MCCB 125 Amps, 16 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 507747 or equivalent model of Siemens/ Schneider.
S & F in repair distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof MCCB DB, TPN 4 way with 250 Amps rated copper bus bar, 415 Volts with in built MCCB 125 Amps, 16 KA, 01 No., earth bar IP 43 protection, flush to wall complete all as specified and directed. Make : Legrand Model: 5077 45 or equivalent in Siemens/ Schneider
S & F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 100 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 10 or equivalent in Siemens / Schneider
S & F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 100 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 11 or equivalent model of Siemens / Schneider
S &F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 12 way with 100 Amps rated copper bus bar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 12 or equivalent model of Siemens / Schneider
S & F in repair MCB SP 240 Volts, 6 to 40 Amps complete all as specified and directed. Make- Make-Havells/Legrend/Crabtree
S & F in repair MCB SP 240 Volts, 63 Amps complete all as specified and directed. Make- Make-Havells/Legrend/Crabtree
S & F in repair MCB SPN 240 Volts,32 to 40 Amps complete all as specified and directed.Make- Make-Havells/Legrend/Crabtree
S & F in repair MCB SPN, 240 Volts, 63 Amps complete all as specified and directed. Make-Havells/Legrend/Crabtree
S & F in repair Earthing complete with galvanised GI earth plate eletrode 600x600x6mm thick,burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate n.less than 1.5mtr below normal.GL surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm dia GI light grade pipe through upper end of earth plate upto main DB of bldg with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate MS funnel with wire mesh fixed on water pipe and Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforeced with MS bars 8mm dia @ 150C/c with both ways complete with lifting handle all as shown in electrical plate no 5 of SSR of part-I (1991) complete all as specified and directed by Engr-in-charge.
S&F in replacement of energy efficient Surface/Wall Mounted 20W integrated LED batten 4 feet Fitting with polycarbonate housing. Total system Lumen of 20W to 22W LED should be 2200 or above in Cool day Light(5700K to 6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>110 Lm/w, THD(%) < 20, LED Lamp LED Lamp Efficacy>130 Lm/W with Average life of 50000 Burning hours. Complete with all accessories as required with connections. complete all as specified and directed by Engg –in-charge. Make - Havells cat Part No. - LUMILINEBS20WLED865SPCWH, Wipro Cat part No. - LL20221XXX65NE3 or equivalent in Philips.
S&F in replacement energy efficient LED batten tube light, Surface/Wall Mounted 9W to 10W integrated LED 2 feet Fitting with polycarbonate housing. Total system Lumen of 9W Led should be 990 or above in Cool day Light(5700K to 6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>110 Lm/w, THD(%) < 20, LED Lamp, LED Lamp Efficacy>130 Lm/W with Average life of 50000 Burning hours. Complete with all accessories as required with connections. Make Havells Cat Part No. - LUMILINEBS9WLED865SPCWH, Wipro CAT Part No. - LL20111XXX65NE3 or equivalent in Philips.
S&F LED building securityLight fitting 45 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete. Make :- Havells Cat part no-ENDURAPEARLNEOSL45WLED757SASYTOPC/Wipro Cat part no-LR02501XXX57XX or equivalent in Philiphs.
S & F in replacement Ceiling rose, PVC/ polycarbonate, isolated body type three terminal, 240 volt complete all as specified and directed. Make-Anchor/Havells/SSK
S& F in repair exhaust fan 300 mm dia sweep, 900 RPM, 240 Volt heavy duty with louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers of suitable size complete all as specified and directed. Make:-Havells/Usha/Bajaj/Crompton. Note - Old dismanteled exhaust fan shall be deposited to MES store yard from existing location .
S& F exhaust fan 450 mm dia sweep, 900 RPM, 240 Volt heavy duty with louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers of suitable size complete all as specified and directed.Make:-Havells/Usha/Bajaj/Crompton Note - Old dismanteled exhaust fan shall be deposited to MES store yard from existing location .
S& F exhaust fan 600 mm dia sweep, 900 RPM, 240 Volt heavy duty with louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers of suitable size complete all as specified and directed.Make:-Havells/Usha/Bajaj/Crompton Note - Old dismanteled exhaust fan shall be deposited to MES store yard from existing location .
Supply & fix in repair ceiling fan (White colour) 230 V, 1400 mm sweep,speed 290 RPM , BEE 5 star rated having rod length 300 mm complete all as specified and directed.Make- Havells/Bajaj/Orient. Note - Old dismanteled ceiling fan shall be deposited to MES store yard from existing location .
Supply and Fixing of five star rated Geysers of cap. 25 Ltr, Electric Driven, Single phase, 240 V, Storage vertical type and heating element 2 KW, inner shell made up of copper, automatic cutoff including electrical and water connection and fixed on the wall with mild steel fastner 150 mm long and 10 mm dia with pin and bolts complete all as specified and directed. Make: HAVELLS/V GAURD /USHA. Note - Old dismanteled geysers shall be deposited to MES store yard from existing location .
M&L for Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified.
Vishal Traders
PARKASH ENTERPRISES
R K Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .