Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.0 CrAccepted-AOC VPO KHERI SANWAL TEHSIL AND DISTT CHARKHI DADRI 127306 | CHARKI DADRI | HARYANA | 127306 | 1 | Accepted-AOC Lowest | |
| 2 | 2₹2.0 Cr+₹5.0 L (2.51%)Rejected-AOC HOUSE NO 953 SECTOR 23 HUDA BHIWANI TEHSIL AND DISTRICT BHIWANI | BHIWANI | BHIWANI | HARYANA | 2 | Rejected-AOC Higher | |
| 3 | 3₹2.0 Cr+₹5.5 L (2.78%)Rejected-AOC 858 SECTOR 23 127021 2021R109 | BHIWANI | HARYANA | 127021 | 3 | Rejected-AOC Higher | |
| 4 | 4₹2.1 Cr+₹16.2 L (8.18%)Rejected-AOC | 4 | Rejected-AOC Higher |
| Sl No | Description | Qty | Unit | MAHA LAXMI CONSTRUCTION COMPANY L2 | M/S SHREE BALAJI BUILDERS L3 | SANJAY KUMAR CONT L1 | BALJIT SINGH CONTT L4 |
|---|---|---|---|---|---|---|---|
| 1.00NS Item | |||||||
| 1.10 | Supply erection testing of reputed make LED light 100
wats with fittings and accessories complete in all
respect | 5 | Each | 5,000 ₹25,000 | 10,500 ₹52,500 | 100 ₹500 Lowest | 2,500 ₹12,500 |
| 2.10 | RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked 800LPM x 12.50M Head | 2 | Each | 1,25,000 ₹2,50,000 | 4,50,000 ₹9,00,000 | 70,000 ₹1,40,000 Lowest | 70,000 ₹1,40,000 Lowest |
| 3.10 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables
up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2Outer Sheathed, /1100V grade as per IS 7098(Part 1) 1988with up to date amendments along with all accessories like thimble lugs
etc for motors as per entire satisfaction of Engineer-incharge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. 10Sqmm size. | 120 | Per Metre | 600 ₹72,000 | 2,150 ₹2,58,000 | 300 ₹36,000 Lowest | 600 ₹72,000 |
| 4.10 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having
following item for 1Non clog submercible pumping)
DOL Starter :-
1.Main MCCB(ABB/LandT/
SCHNEIDER), Controlling MCB - 2nos
2.THERMAL OVER LOAD RELAY
(ABB/LandT/SCHNEIDER) - 01nos
3. AUXILARY CONTACTOR
(ABB/LandT/SCHNEIDER) - 01nos
4. START/STOP PUSH BUTTON
(SCHNEIDER/SALZAR/SEIMENS) - 1each
5. EMERGENCY SWITCH
(SCHNEIDER/SALZAR/SEIMENS) - 01nos
6. DIGITAL VAF METER
(SECURE/SELEC/TECHNO/ABB) - 01nos
7. CT RATIO - 100/5(AE/KAPPA/LandT)
8. CAPACITOR BANK AS PER LOAD
REQUIREMENT
9. CHANGE OVER SWITCH AS PER LOAD
(SCHNEIDER/SALZAR/SEIMENS)
10. SELECTOR SWITCH
(SECURE/SELEC/TECHNO/ABB)
11. SINGLE PHASE PREVENTER
(SECURE/SELEC/TECHNO/ABB)
800LPM x 12.50mtr Head = 5BHP | 2 | Each | 1,00,000 ₹2,00,000 | 1,25,000 ₹2,50,000 | 30,000 ₹60,000 | 25,000 ₹50,000 Lowest |
| 5.10 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1Non clog submercible pumping)
DOL Starter :-
1.Main MCCB(ABB/LandT/
SCHNEIDER), Controlling MCB - 2nos
2.THERMAL OVER LOAD RELAY
(ABB/LandT/SCHNEIDER) - 01nos
3. AUXILARY CONTACTOR
(ABB/LandT/SCHNEIDER) - 01nos
4. START/STOP PUSH BUTTON
(SCHNEIDER/SALZAR/SEIMENS) - 1each
5. EMERGENCY SWITCH
(SCHNEIDER/SALZAR/SEIMENS) - 01nos
6. DIGITAL VAF METER
(SECURE/SELEC/TECHNO/ABB) - 01nos
7. CT RATIO - 100/5(AE/KAPPA/LandT)
8. CAPACITOR BANK AS PER LOAD
REQUIREMENT
9. CHANGE OVER SWITCH AS PER LOAD
(SCHNEIDER/SALZAR/SEIMENS)
10. SELECTOR SWITCH
(SECURE/SELEC/TECHNO/ABB)
11. SINGLE PHASE PREVENTER
(SECURE/SELEC/TECHNO/ABB)
800LPM x 25mtr. Head = 7.5BHP | 2 | Each | 1,00,000 ₹2,00,000 | 1,55,000 ₹3,10,000 | 42,000 ₹84,000 | 40,000 ₹80,000 Lowest |
| 6.10 | Operation and Maintenance for complete scope of work
mentioned in the DNIT (Disinfection material supplied
by PHED) as per schedule-IV for a period of 5year
after 12month during defect liability period and 03
Months trial run period will be charged to the A/ Mtc.
estimate complete in all respect as per Approved NIT.
(i) During defect liability period (Operation only) after
3month
Trial run period. | 1 | Job | 5,00,000 ₹5,00,000 | 5,50,000 ₹5,50,000 | 3,00,000 ₹3,00,000 Lowest | 5,00,000 ₹5,00,000 |
| 7.10 | (ii) During 1st year after defect
Liability period. | 1 | Job | 5,00,000 ₹5,00,000 | 6,00,000 ₹6,00,000 | 3,00,000 ₹3,00,000 Lowest | 5,00,000 ₹5,00,000 |
| 8.10 | (iii) During 2nd year. | 1 | Job | 5,00,000 ₹5,00,000 | 6,30,000 ₹6,30,000 | 3,00,000 ₹3,00,000 Lowest | 5,00,000 ₹5,00,000 |
| 9.10 | (iv) During 3rd year | 1 | Job | 5,00,000 ₹5,00,000 | 6,80,000 ₹6,80,000 | 3,00,000 ₹3,00,000 Lowest | 5,00,000 ₹5,00,000 |
Tender Value
₹2.4 Cr
EMD Value
₹4.7 L
Closing Date
27 Aug 2026, 3:00 pmClosed
SURYA KANT
Bhiwani PHED No. 1
NANGLA and PATHERWALI Construction of water works including Brick lined S and S tank Boundary wall clear water tank high level tank filter beds pump chamber Rising main line electric transformer pumping machinery Operation and Maintenance during
2026_HRY_540439_1
20262FBD87C3 B072 4057 8BBC 26ABBF22579E553PUH
Open Tender
Civil Works
Works
365 days
NAGLA TOSHAM
NANGLA and PATHERWALI Construction of water works including Brick lined S and S tank Boundary wall clear water tank high level tank filter beds pump chamber Rising main line electric transformer pumping machinery Operation and Maintenance during
2 documents required · 2 mandatory
₹15,000
₹4.7 L
Yes
8 Oct 2026
12 Aug 2026
27 Aug 2026
12 Aug 2026
27 Aug 2026
12 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1NS Item | |||||
| 1.1 | Supply erection testing of reputed make LED light 100
wats with fittings and accessories complete in all
respect | 5 | Each | - | - |
| 2.1 | RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked 800LPM x 12.50M Head | 2 | Each | - | - |
| 3.1 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables
up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2Outer Sheathed, /1100V grade as per IS 7098(Part 1) 1988with up to date amendments along with all accessories like thimble lugs
etc for motors as per entire satisfaction of Engineer-incharge complete in all respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / RR Cables. 10Sqmm size. | 120 | Per Metre | - | - |
| 4.1 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having
following item for 1Non clog submercible pumping)
DOL Starter :-
1.Main MCCB(ABB/LandT/
SCHNEIDER), Controlling MCB - 2nos
2.THERMAL OVER LOAD RELAY
(ABB/LandT/SCHNEIDER) - 01nos
3. AUXILARY CONTACTOR
(ABB/LandT/SCHNEIDER) - 01nos
4. START/STOP PUSH BUTTON
(SCHNEIDER/SALZAR/SEIMENS) - 1each
5. EMERGENCY SWITCH
(SCHNEIDER/SALZAR/SEIMENS) - 01nos
6. DIGITAL VAF METER
(SECURE/SELEC/TECHNO/ABB) - 01nos
7. CT RATIO - 100/5(AE/KAPPA/LandT)
8. CAPACITOR BANK AS PER LOAD
REQUIREMENT
9. CHANGE OVER SWITCH AS PER LOAD
(SCHNEIDER/SALZAR/SEIMENS)
10. SELECTOR SWITCH
(SECURE/SELEC/TECHNO/ABB)
11. SINGLE PHASE PREVENTER
(SECURE/SELEC/TECHNO/ABB)
800LPM x 12.50mtr Head = 5BHP | 2 | Each | - | - |
| 5.1 | PANEL BOARDS FOR MOTOR: - Supply Erection, Testing and Commissioning of wall mounted electrical LT Panel board, fabricated from SWG CRCA sheet duly stoten with suitable angle iron frame work and completely powder coated of suitable size deep having following item for 1Non clog submercible pumping)
DOL Starter :-
1.Main MCCB(ABB/LandT/
SCHNEIDER), Controlling MCB - 2nos
2.THERMAL OVER LOAD RELAY
(ABB/LandT/SCHNEIDER) - 01nos
3. AUXILARY CONTACTOR
(ABB/LandT/SCHNEIDER) - 01nos
4. START/STOP PUSH BUTTON
(SCHNEIDER/SALZAR/SEIMENS) - 1each
5. EMERGENCY SWITCH
(SCHNEIDER/SALZAR/SEIMENS) - 01nos
6. DIGITAL VAF METER
(SECURE/SELEC/TECHNO/ABB) - 01nos
7. CT RATIO - 100/5(AE/KAPPA/LandT)
8. CAPACITOR BANK AS PER LOAD
REQUIREMENT
9. CHANGE OVER SWITCH AS PER LOAD
(SCHNEIDER/SALZAR/SEIMENS)
10. SELECTOR SWITCH
(SECURE/SELEC/TECHNO/ABB)
11. SINGLE PHASE PREVENTER
(SECURE/SELEC/TECHNO/ABB)
800LPM x 25mtr. Head = 7.5BHP | 2 | Each | - | - |
| 6.1 | Operation and Maintenance for complete scope of work
mentioned in the DNIT (Disinfection material supplied
by PHED) as per schedule-IV for a period of 5year
after 12month during defect liability period and 03
Months trial run period will be charged to the A/ Mtc.
estimate complete in all respect as per Approved NIT.
(i) During defect liability period (Operation only) after
3month
Trial run period. | 1 | Job | - | - |
| 7.1 | (ii) During 1st year after defect
Liability period. | 1 | Job | - | - |
| 8.1 | (iii) During 2nd year. | 1 | Job | - | - |
| 9.1 | (iv) During 3rd year | 1 | Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
BOQ_619797.xls
BOQ • 0.26 MB
OT0158102.pdf
Other Document • 2.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .