Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC PANDIT JAGAN NATH WALI GALI MALOUT DISTT SRI MUKTSAR SAHIB | SRI MUKTSAR SAHIB | PUNJAB | 151202 | L1 | Accepted-AOC L1 |
Tender Value
₹31.0 L
EMD Value
₹62,062
Closing Date
2 Aug 2019, 5:00 pmClosed
EXECUTIVE ENGINEER
EE WSS FZR AT ZIRA
PROVDING WATER SUPPLY SCHEME FOR VILLAGE MARUR BIFIRCATION FROM EXISTING WATER SUPPLY SCHEME KHOSA DAL SINGH BLOCK ZIRA DISTRICT FEROZEPUR Pb Under PRWSSIP SUB COMPONENT 1A ii NRDWP)
2019_WB_34573_1
TENDE 1A(II) OF VILLAGE MARUR
Open Tender
Civil Works
Item Rate
390 days
FEROZEPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
TIA
₹62,062
Yes
15 Jun 2020
5 Jul 2019
5 Aug 2019
5 Jul 2019
2 Aug 2019
5 Jul 2019
Amount
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tubewell is lowered & tested, equipment as required such as hand boring machine and its accessory,transportation to site and vice versa etc. complete in all respect. (c) Boring with 200mm I/d Housing Pipe 0 to 150m
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. (b) 150mm nominal diameter (weight 21.6 kg per meter) 5.4mm thickness
Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest with SS socket to connect Strainer to Strainer Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore. (a) 150 mm internal diameter (slot size 0.15mm) 5.0 mm thickness
Supplying, fixing & lowering of Stainless Steel sokect as per IS: 8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore. Complete in all respect (a) 150 mm internal diameter
Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect. (b) 150 mm internal diameter
Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) and heavy metals
Peovision for collecting sand and sealves anylsis of different strata of sand
Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect (c) 150 mm internal diameter
Supplying & fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect. (b) 150mm internal diameter (weight 21.6 kg per meter) 5.4 mm thickness
Supplying & fixing of M.S. Clamp of size 150mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Development of stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. (a) Capacity of Air compressor 300 cfm at 250 PSI
Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Boring with 200 mm i/d MS Casing Pipes and withdrawing the same after completion of Tubewell is required to be Abandoned on the basis of non Availability of Portable water.
Constructing 1 No. of 25 KL (25000Liters ) capacity with sill level not less than 13.00m height upto FSL 15.50 mtr from formation lvel complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing DI K-9 D/F expansion joints conforming to (IS-1536-1989) or lastest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, conforming to ISI-13382 and DI K-9 D/F sluice valave duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet & scour pipes, including providing & installing inlet, outlet, scour pipes and overflow DI K -9 double flanged pressure pipes horizontally cast in sand moulds as per IS -7181/1986 & latest duly ISI marked from bottom dome to duck foot bend and further upto 7.75 mtr. as per detail specifications. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications.
Providing, Laying, Fixing & Jointing of PVC pipes (ISI Marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing & testing, complete as per specifications
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete @ 3Kg Each
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 04No. With each of Size 0.6m x 0.6m
Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Annexure A12 – 2 & Drawings D-12 & D-17.
Providing, Laying, Fixing & Jointing of PVC pipes (ISI Marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing & testing, complete as per specifications
PVC pipe 63mm o/d 6Kg2/Cm2
PVC pipe 110mm o/d 6Kg2/Cm2
Providing & Laying, Jointing, Fixing, Testing ISI marked G.I. Pipe as per IS 1239 B-class, premium make such as (Jindal Hissar) including cost of specials G.I pipe 63mm 1/d
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. As per analysis A13
Hand boring horizontly for crossing of pipe under road or any other obstacie by using Auger/Bocki method. Including excavation, sringing and jointing of pipe complete
Disinfection unit electrically basen dosing plant on Sodium Hypochlorite along with 200 ltr. Of Sodium Hypochlorite in container complete in all respects (as per Technical Manual of DWSS- Clause 6.45 (c ) (Pg 64)
Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 146 LPM against a head of 55.00 mtr (5.00 BHP) along with electric panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. including M.S. Column Pipe of suitable size 50 mm =44 mtr (in 3 mtr lengths each with flanges , screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable (reputed make) complete in all respects as per standard Specifications
Providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard Drawing D-8 & (as per Analysis A-6).
Providing & fixing G.I. Barbed wire 2 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 (as per Analysis A-8)
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7 & Analysis A-9
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3 & Analysis A-5 including Carriage of material
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-6 complete in all respects . including Carriage of material
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-7 & Analysis A-11. including Carriage of materia
Providing & fixing MS Sign Board as per standard size of DWSS as per analysis A-24 & Drawing D-20
Construction of Pump Chamber 2.20 X 2.20m size including Gravil Pit and cost of electric wiring as per DWSS standard design, Drawing & Analysis, complete in all respects. With gravil pit
Provision for Sanitary Latrine near Pump Chamber ( as per IHHL)
Providing Proposed water connection to household up to wall with providing, Laying jointing testing, G.I pipe lines 15mm i/d = 2.50 mtr B-class as per CSR 28.36(a), (Above GL) prov. & Fixing MDPE pipe 15mm i/d with spls 2.00 mtr(Below G L) including Cost of Specials such as tees, bends sockets elbow etc. cutting, threading and testing in trenches in groud and ISI marked 15mm i/d GM ferrule as per specifications
O&M of scheme for 3 Month after execution of work at site. Including Sallary of Pump Operator , Electricity Bill nad Bleaching Powder
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .