Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹9.6 L+₹1.2 L (15.0%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹9.6 L+₹1.3 L (15.6%)Rejected-Finance | L3 | Rejected-Finance Not being lowest |
Tender Value
₹11.2 L
EMD Value
₹23,000
Closing Date
25 Mar 2021, 6:00 pmClosed
GE (AF) B/R Chakeri Kanpur
GE (AF) B/R Chakeri Kanpur
PROVN OF POWER POINTS FOR VENTILATIONS ALONG WITH UPS AND CONNECTED WORKS FOR COVID ICU WARD AND WATER PROOFING OF CORRIDOR ALONGWITH ACRYLIC PANEL IN MEDICAL STORE AT 7AFH KANPUR
2021_MES_424842_2
GE(AF)/CHK/T-60 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AFH 07 Kanpur Cantt
Class E and cat b(i)
8 documents required · 8 mandatory
₹500
GE (AF) B/R Chakeri Kanpur
₹23,000
29 Apr 2021
11 Mar 2021
27 Mar 2021
11 Mar 2021
25 Mar 2021
13 Mar 2021
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of XLPE insulated Cable including getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and directed.
M & L for spreading and leveling dry clean Ganga sand in trenches for cushioning of under ground cable complete all as specified and directed.
M & L for sub-class old size brick laid in trenches for cable protection complete all as specified and directed.
S & F of 80 mm nominal bore light grade galvanised mild steel tubing with all fittings and fixed to poles / walls with mild steel clamps, bolts, nuts and washers complete all as specified and directed.
Laying only XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 120 sq mm 3.5 core, laid in trenches/ducts /encased in GI pipe /fixed to pole including taking out of existing unserviceable cable/OH conductor complete all as specified and directed. (Note : Cable will be issued under Sch 'B' free for fixing.)
S & F in repair 50 sqmm, 3.5 core cross sectional area XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor of 1100 volts grade laid in trenches / ducts /encased in GI pipe / fixed to pole and OH conductor complete all as specified and directed.
M & L for boring through existing road with trench less method for passing of underground cable complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip of size 32 mm x 6 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthing test point as indicated with testing on completion including pit chamber of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate and 40 mm thick cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6mm dia MS bars @ 150 mm c/c with two No’s fitting handle, GI pipe 20 mm dia light grade with funnel & wire mesh for watering and 40 mm dia light grade GI pipe for protection of earth strip etc complete all as specified and directed. Note :- (i) The rate of earth strip of 7.5 Mtr per earthing deemed to be included in the quoted unit rate. (ii) Earthing result should not be more then 2 ohm.
M & L for GI earthing strip of size 32 mm x 6 mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed.
S & F online UPS of capacity 30 KVA three phase 'in' and three phase 'out' 320-480 Volt range complete with batteries ( 30 nos x 42 AH ) 12 V, DC (300 V - 411 Volt ) with 30 minutes back up and stand for mounting of batteries and connecting lead with panel etc complete all as specified and directed.
M & L for point wiring with PVC FRLS insulated and unsheathed copper stranded conductor cable of size 2.5 Sqmm, 1100 V drawn in and including PVC casing and capping complete including cast iron/ pressed steel terminal box of size 1.6 mm, 3 mm thick bakelite sheet for mounting switch, socket, brass screws and washer including PVC insulated and unsheathed solid copper wire of size 2.5 Sqmm will be used as continuous earth wire for the following :-
One 3 pin 15 Amp socket independent but with 2.5 Sqmm PVC insulated unsheathed copper stranded conductor and earth wire with 1.5 Sqmm
Ditto all as per item No.14.01 above but with 4 sqmm cable complete all as specified and directed.
S & F of switch socket outlet combination 3-pin 15 Amp, 3 -pin 5 Amp outlet also flush type (non shuttered) including for existing points complete all as specified and directed.
S & F sheet metal enclosures for MCB distribution board TPN, 4 way double door type including with MCCB 4 Pole, 100 Amps, 16 KA 'fixed type' as incomer with 200 amp rated bus bar complete all as specified and directed.
S & F sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed.
S & F Isolator TPN, 63 Amp 4 pole Isolator, 415 Volt as in existing DBs complete all as specified and directed.
S & F MCB SP upto 30 Amp, 240 Volt complete all as specified and directed.
S & F Isolator SPN, 20 to 40 Amp, 240 Volt complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthing test point all as specified or indicated including testing on completion including chamber pit of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate and RCC(1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia MS bars @ 150 mm c/c and RCC cover slab of 40 mm thick with two no’s fitting handle, GI pipe 20 mm dia light grade with funnel & wire mesh for watering and 40 mm dia light grade GI pipe for earth strip 4 mm protection etc. complete all as specified and directed.
S & F in repair sub main wiring with two runs of single core, 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable of LT 1100 grade FRLS cable drawn and PVC Casing N Caping 20 mm dia with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 2.5 Sqmm as earth wire (green in colour ) run through PVC Casing N Caping and connected to common earth dolly complete all as specified and directed. Note- Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run.
Ditto all as per item No. 22.00 here-in-before but for 6 Sqmm, 2 single core with PVC FRLS insulated, unsheathed stranded copper conduct cable of size 4 Sqmm as earth lead complete all as specified and directed.
M & L for sub main wiring with three runs of single core, 10 Sqmm (nominal area) PVC insulated and unsheathed multi-stranded copper conductor cable LT 1100 grade FRLS cable drawn in PVC casing and Capping with all necessary fittings and accessories and two run of PVC insulated and unsheathed single core cable multi stranded with copper conductor of size 6 Sqmm as continuous nuetral and earth wire (green in colour) respectively, run through PVC casing and capping and connected to the terminal and common earth dolly complete all as specified and directed. Note. Four run of cable and one run of PVC casing and capping and one run of earth continuity wire shall be measured as one run.
M & L for point wiring with PVC FRLS insulated and unsheathed copper stranded conductor cable of size 1.5 Sqmm, 1100-V, drawn in and including PVC casing and capping complete including cast iron/pressed steel terminal box of size 1.6 mm thick and 3 mm thick bakelite sheet for mounting switch, socket brass screws and washer including PVC insulated and unsheathed solid copper wire of size 1.5 Sqmm will be used as continuous earth wire for the following :-
One light /fan point controlled by one, one way switch
One 5/6 Amp socket on the same board with other switch
One 5/6 Amp socket on independent board.
S & F switch piano type 240 V, 5 Amp, SP one way flush type complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin 5 amps complete all as specified and directed.
S & F in replacement ceiling rose surface backelite of size 65 mm x 20 mm, three terminal complete all as specified and directed.
S & F sheet metal enclosures for MCB distribution board SPN, 4-way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed.
S & F in replacement MCB SP upto 30 Amp, 240 Volt complete all as specified and directed.
S & F in replacement fluorescent tube light fitting, energy efficient T-5 LED batten and integrated type signle tube of 20 Watt, 4-feet long, white complete with LED rod, LED driver and LED batten etc including all accessories pre-wired and connecting up with three core flexible copper cord having minimum size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting complete all as specified and directed.
Ditto all as per item No.31.00 above but for 10 watt, 2 feet long tubelight fittings complete all as specfied and directed.
S & F 380 mm sweep exhaust fans AC single phase 230 / 240 V of size with louver complete all as specified and directed.
S & F 450 mm sweep air circulator fans industrial type steel body, 230 volts single phase oscillating, heavy duty suitable for wall mounting including electrical connection with the ceiling rose with 3-core flexible wire complete all as specified and directed.
Supply only bottled water dispenser, having option of dispensing hot and cold water having cooling capacity 3 ltrs/hr and tank capacity of 3.40 ltrs, heating capacity 6.0 ltrs / hr and tank capcity 1.60 ltrs, working in R-134a refrigerant system complete all as specified and directed.
S & F socket out let combination multipurpose 3-Pin, 5-amp, 240 volt and with 2-pin, 5-amp outlet, flush type including for existing points also (non shuttered) complete all as specified and directed.
M & L for preparation of new steel surfaces exceeding 10 cm width or girth not other wise described and applying two coat of synthetic enamal paint over one coat of red oxide or zink chrome primer complete all as specified and directed.
S & F framed work such as grills, gratings, cattle trap etc. with ends of bar shouldered and/or riveted or forged in to spikes, framed guard bars barred iron doors, ladders framed balusters, walk ways railings, conforming to Fe.290. Gde-E-165 complete all as specified and directed.
M & L for cutting holes exceeding 150 sqcm but not exceeding 400 sqcm into or through in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in CM (1:3) or PCC (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed.
M & L for plain PCC (1:2:4) type B-1 using 20 mm graded stone aggregate for fixing holdfast and coping including all necessary form work complete all as specified and directed.
S & F 2 mm thick fibre glass reinforced translucent plain sheet fixed with coach screw and washer as in roof, wall etc complete all as specified and directed.
M/S Balaji Infratech
SHYAM AND SONS ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .