Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110 075 | NEW DELHI | NEW DELHI | DELHI | 110075 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹17.4 L+₹1.7 L (11.1%)Rejected-Finance WZ 1043 C IIND FLOOR NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹19.6 L+₹4.0 L (25.2%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹19.9 L+₹4.2 L (26.9%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | L4 | Rejected-Finance other than lowest | |
| 5 | L5₹22.0 L+₹6.3 L (40.0%)Rejected-Finance N A | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
21 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
REPAIRS TO CRACKS ROOF REATMENT GUNITING PLASTER MASNORY AND GROUNTING AT OD SHAKURBASTI AND HIRANKUDNA UNDER GE N DELHI CANTT 10
2020_MES_364152_1
GE/NORTH-32/2020-21
Open Tender
Civil Works
Works
180 days
GE (N) DELHI CANTT-10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹50,000
Yes
19 Oct 2020
25 Jul 2020
24 Aug 2020
25 Jul 2020
21 Aug 2020
8 Aug 2020
60 days
Amount
Demolition of reinforced cement concrete in roof floor (other than ground floors) beams staircase, landing chajja and similar work complete all as specified.
M&L for Reinforced cement concrete 1:2:4 type B-1 ( using 20 mm graded cdrushed stone aggregate) as in chajjas and the like, all as specified and directed by Engr-in-Charge.
Use and waste of form work to soffits of suspended slab such as chajja slab, chullahood etc landing and similar work not exceeding 200mm thick surface horizontal or sloping, fair finished surface of concrete, all as specified .
M&L for TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
M&L for TMT bars 6mm to 8mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified.
M&L Taking down cement plaster from other than fair faces of any description from brick, stone walls or concrete surfaces including raking out joints, hacking for key,scrubbing down with water , rendering 15mm thick in cement mortar 1:6,mixed with PD proof 101 LW(+) of Dr fixit or equvalant integral WP admixer @200 ml/bag of cement over two coats of super latex 302 of Dr fixit or equ. in the ratio 1:4: 7 (one part super latex 302, 4 part water and 7 part cement ) @ 1.50 Kg of homogenious mixture per Sqm in two coats and finished the surface even and fair without using extra cement complete all as specified and directed. Note- PD proof 101 LW(+) and super latex 302 shell be measured and paid seperatly
M&L Taking down cement plaster of any description from brick, stone walls or concrete surfaces including raking out joints, hacking for key,scrubbing down with water,and rendering 15 mm th in cm (1:4) in two layers (10mm+5mm ) mixed with PD proof 101 LW(+) of Dr fixit or equvalant integral WP admixer @200 ml/bag of cement over two coats of super latex 302 of Dr fixit or equ. in the ratio 1:4: 7 (one part super latex 302, 4 part water and 7 part cement ) @ 1.50 Kg of homogenious mixture per Sqm in two coats and finished the surface even and fair without using extra cement complete all as specified and directed. Note- PD proof 101 LW(+) and super latex 302 shell be measured and paid seperatly
M&L Taking down cement plaster of any description from brick, or concrete cieling surfaces including raking out joints, hacking for key,scrubbing down with water,and rendering 10 mm th in cm (1:4) in mixed with PD proof 101 LW(+) of Dr fixit or equvalant integral WP admixer @200 ml/bag of cement over two coats of super latex 302 of Dr fixit or equ. in the ratio 1:4: 7 (one part super latex 302, 4 part water and 7 part cement ) @ 1.50 Kg of homogenious mixture per Sqm in two coats and finished the surface even and fair without using extra cement complete all as specified and directed. Note- PD proof 101 LW(+) and super latex 302 shell be measured and paid seperatly
M&L for cutting chases in V shape, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth on Bk walls complete all as specified and directed.
Supply only PD proof 101 LW (+) of Dr Fixit or eqe. complete all as specified.
Supply only super latex 302 of Dr Fixit or eqe.complete all as specified.
Demolition of brick/stone masonry built in CM. all as specified.
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 all as specified.
M&L brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 but except bricks all as specified.
M&L half brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:4 all as specified and directed.
S&F chicken wire mesh fixed with nails at the junction of two desimiler material on wall, roof or any other surface/location all as sepecified and directed
Demolition of cement concrete unreinforced in any position not exceed 15 cm thickness complete all as sepecified and directed
M&LProviding cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0.
M/L PCC 1:3:6, type C2 75mm thick fair finished surfaces .as in plinth protection/ foot path.
M/L PCC 1:2:4, type B1 40mm thick fair finished surfaces .as in flooring using 20 mm graded stone aggregate.
M&L for glass dividing strips , 3mm thic and width of strip 38mm inserted in position to confirm design
M&L Roughening surfaces of old concrete surfaces by picking sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 Kg/Sqm complete all as sepecified and directed.
M & L for Water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge. (a) M&L for 15mm thick plaster screed bed layer in CM 1:3 finished even and smooth mixed with water proofing compound on concrete surfaces. (WPC shall be measured and paid separately) (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bituminous primer @ 0.20 Kg/Sqm of area complete all as specified. (c) Laying APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 Kg/Sqm with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakage & seepages and rectifying the same to the entire satisfaction of GE. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified & as directed by Engr in Charge
Supply only water proofing compound @ 200 ml per 50 kg cement or as per manufacturer instructions complete all as specified.
M&L for plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in roof padding,roof kerbs of mud spots rounded or chamfered levelling /sloping course finished even and fair complete all as specified.
M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand blasting, scrubbing down conrete sufrace with wire brushes cleaning with water allowed to dry and applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited all as specified and applying two layess of guniting over steel welded mesh 2mm dia of wire and aperture 75mm,total thickness of gunite n.exc 25mm thick (average thickness) in cement mortar 1: 2 using OPC 53 grade cement mixed with polycrete admixture @ 2% by weight of cement or as per manufacturers instructions and finally applying cement plaster over gunited surface of required thickness to give even, uniform and smooth finish conforming to proper gerometrics in cement mortar ( 1 : 3) to match with the existing surface as in sides and soffits etc of slabs, chajjas, fins, facias, parapets , columns and beams etc complete including necessary scaffolding, shuttering, necessary chases to brick work or RCC members at any height upto 4 storey bldgs all as specified. (Note : Steel welded mesh is to be tightend / welded with the existing re-inforcement. The cost of welded mesh is deemed to be included in the unit rate quoted by the contractor).
M&L preparing new/old galvanized wire mesh in door/windows and applying two coats of blue oil paint.
M&L for preparing newly plastered surfaces of ceilling and applying two coats of white wash complete all as specified.
M&L preparation of newly plastered surface on walls and applying 2 coat of OBD over a coat of chalk whiting complete all as specified.
M&L two coats of cement base paint on walls including preparation on new surfaces over a coat of primer complete all as specified and directed. .
M&L for preparation of old decorated plastered or unplastered surfaces wall by brooming down scrapping down smoke and efflorescent salts etc and applying two coat of white wash on walls complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of wall and applying two coats of oil bound distemper including preparation of old surfaces by brooming down or steel wire brushing , scraping down smoke suit , moulds,filling gaps with wall care putty, complete all as specified and directed.
M&L for preparation of old decorated surfaces of any description and applying one coats of cement base paint on external wall surface complete all as specified and directed. ( Height of Bldg is upto 15 mtr )
Disconnecting existing overhead tanks,setting aside or lowered if required for repairing ,cleaning etc and hoisting if reqd reconnecting and refixing in position but capacity exceeding 250 litres and not exc 500 litres complete all as specified & directed.
Disconnecting existing overhead tanks,setting aside or lowered if required for repairing ,cleaning etc and hoisting if reqd reconnecting and refixing in position but capacity exceeding 500 litres and not exc 1000 litres complete all as specified & directed.
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc capacity exceeding 250 litres and not exc 500 litres complete all as specified & directed.
Cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc capacity exceeding 500 litres and not exc 1000 litres complete all as specified & directed.
M & L for form work as in suspended floors, slab and similar other locations not exc 200 mm thick for rough finished surface, complete all as specified.
Demolition of RCC jali , ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling build in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M & L for form work edges of suspended floors, slab and similar other locations not exc 100 mm wide for rough finished surface, complete all as specified.
M & L for providing precast reinforced cement concrete jallies 45 mm thick including all mouldings type B-0 1:2:4 (12.5mm graded stone aggreagte) set in cement mortar 1:4 including taking down Old RCC Jallies complete all as specified.
M&L for renderning 15 mm thick in CM 1:4 on fair faces of brick/concrete surfaces finished even and fair with out using extra cement and two coats of cement base paint with one coat alkali resistant primer complete all as specified and all as directed by Engineer in charge .
S & F in repairs cast iron (sand cast) soil, waste and vent pipes in any length with or without ears, with cement joints (in CM 1:1), laid in trenches or in floors , bore of pipe 75 mm including dismanting of old pipes complete all as specified and as directed
S & F in repairs cast iron (sand cast) soil, waste and vent pipes in any length with or without ears, with cement joints (in CM 1:1) fixed to walls, bore of pipe 75 mm including dismanting of old pipes complete all as specified and as directed
S & F in repairs cast iron branch pieces single (equal or unequal) ordinary or inverted, spigot or socket type or with parallel branches, bore of pipe 75 mm fitted with oval access door complete all as directed
S & F in repairs cast iron bends (any radius) tapers or diminishing pieces (larger bore measured) for bore of pipe 75 mm, fitted complete all as directed
S & F in repairs cast iron bends (any radius) with duck's foot or heet resttapers or diminishing pieces (larger bore measured) for bore of pipe 75 mm, fitted complete all as directed
S & F in repairs stack clamps made of flat iron 20x5 mm with iron rod of 16 mm dia for bore of pipe 75 mm fixed to walls with nails of suitable sizes complete all as directed
S & F in repairs cast iron (sand cast) soil, waste and vent pipes in any length with or without ears, with cement joints (in CM 1:1), laid in trenches or in floors, bore of pipe 100 mm including dismanting of old pipes complete all as specified and as directed
S & F in repairs cast iron (sand cast) soil, waste and vent pipes in any length with or without ears, with cement joints (in CM 1:1), fixed to walls, bore of pipe 100 mm including dismanting of old pipes complete all as specified and as directed
S & F in repairs cast iron branch pieces single (equal or unequal) ordinary or inverted, spigot or socket type or with parallel branches, bore of pipe 100 mm fitted with oval access door complete all as directed
S & F in repairs cast iron bends (any radius) tapers or diminishing pieces (larger bore measured) for bore of pipe 100 mm, fitted with oval access door complete all as directed
S & F in repairs cast iron bends (any radius) with duck's foot or heet resttapers or diminishing pieces (larger bore measured) for bore of pipe 100 mm, fitted complete all as directed
S & F in repairs stack clamps made of flat iron 20x5 mm with iron rod of 16 mm dia for bore of pipe 100 mm fixed to walls with nails of suitable sizes complete all as directed
S & F in repairs 110 mm pvc (SWR) pipes single socketed in any length along with rubber ring joints fixed to walls with all accessories complete all as specified and as directed
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc.,including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories)
S&F Plain, galvanised, mild steel sheeting 1mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 incl nessary welding ,screwing, bending etc complete all as specified and directed by Engr-in-Charge. Note: Hieght of building/ shed is upto 12mtr. Contractor will provide safety arrangements.
S&F PVC (SWR) pipes single socketed 150mm dia in any length with rubber ring joints fixed to walls/ column including all fittings as socket, L/T bend incl taking downetc complete all as specified and directed by Engr-in-Charge.
Dismantaling plain or corrugated AC sheeting any gauge, thickness, roof covering all as specified and directed..
S&F 6mm thick asbestos cement, corrugated or semi-corrugated shets in roofs, walls, with 'L' or 'J' type hooks etc all as specified and directed..Note: Hieght of building/ shed is upto 12mtr. Contractor will provide safety arrangements.
M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. The size of block shall be of 6 Qtrs. All roots of plants shall be removed completely and making good the disturbed surface and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge
S&F in repair 15mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls incl taking down all as specified.
S&F in repairs 20mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls incl taking down all as specified.
Cutting chases pinning in making good to facing where required and pointing in CM (1:3) for concealed water tubing etc as in brick walls cutting not exc 10cm girth, complete all as specified and directed.
S&F in repairs 500 ltrs capacity three layer rotational molded polyethylene water storage tanks, colour white (cylindrical vertical with closed top) hoisted of and fixed in position incuding provn of inlet , out let and over flow connection with tank connection nipple of existing pipe dia including, dismantling existing water tanks etc all as specified and directed. ( Make : Sintex , polycon , SPL )
-- Ditto --But 1000 ltrs capacity of tanks
S&F ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (min wt 210 gm each) for 20 mm bore of pipe.
S&F in repairs 15mm Gun-metal, globe or gate valves, with iron wheel head, screwd both ends or iron pipe and fixed etc all as specified and directed.
S&F in repairs 20mm Gun-metal, globe or gate valves, with iron wheel head, screwd both ends or iron pipe and fixed etc all as specified and directed.
Dismantling floor, hearth or wall tiling incliding cement mortar bedding (but not backing ), removing serviceable tiles to store and rubbish off the premisses, complete all as specified and directed.
M & L non skid ceramic tiles coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in colour cement laid over and incliding 15 mm thick cement mortar (1:6) screed bed complete all as specified and directed.
M & L Non-skid ceramic tiles 7 to 8mm thick square area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and joinnted in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L glazed ceramic coloured tiles size 450 x 300x 7-8 mm thick in walls etc set and jounted in neat cement slurry and pointed in colour cement laid over 10mm thick rendering in cement mortar (1:4) complete all as specified and directed.
M & L glazed ceramic coloured tiles size 300 x 200x 7-8 mm thick in walls etc set and jounted in neat cement slurry and pointed in colour cement laid over 10mm thick rendering in cement mortar (1:4) complete all as specified and directed.
S&F in repair vitreous china Squatting pan "Orissa pattern" size 580x440xmm white, with integral foot rest. Complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 ltrs capacity incl PVC float valves, PVC connection and out let pipes complete.
M&L cast iron Nahani trap 75mm out let dia meter with grating incluiding jointing to waste pipe fixed in repair in cement concrete type B-1 (1:2:4) .
S&F in repair Viterous China wash hand basin white, flat back size 550 x 400 mm incl CI or Angle iron 50x50x6 mm brackets one No CP fancy Pillar tap 15mm bore , one No 32 mm dia CP waste coupling, one No 32mm dia PVC flexible waste pipe and one No 15mm bore 450mm long PVC connection complete all as specified and directed by Engineer in charge.
S&F in repair 15mm bore dia stop valves cast copper aloyes, screwed down high pressure with crutch or butterfuly handle , screwed both ends for iron pipe or for unions and fixed.
M&L Indian type WC including demolittion of cement concrete (unreinforced) in sunken portion of WC, area n.exc 1.20 sqm including removing of unserviceable materials and Providing half brick surrounding walls , rendering 10 mm thick plaster in cement mortar ( 1:4 ) with WPC and laying lean concrete in bottom portion of WC and then applying 3mm thick APP membrane over bitumen primer surface of walls and bottom portion of WC with torch method , provide 32 mm dia GI tubing as spout of sunken portion 0.60 m long of approved quality , By filling Khanger / cinder and lean concrete, supply and fix vitreous china Squatting pan "Orissa pattern" size 580x440mm white, with integral foot rest & ' P' traps & jointing new 100 mm dia CI pipe with lead joints to WC ( excluding flushing cistern & flush pipe ) . Testing of sunken portion will be carried out by filling water for 24 Hrs in sunken area complete in all respect as specified and directed . Note : - ( i ) WPC, floor and dado tiles will be measured and paid separately.
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - Rs.18686.00
M/S AADI ENTERPRISES
MOHIT ENTERPRISES
QUALITY CONSTRUCTIONS CO
friends associeates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .