Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.3 LAdmitted-Finance | ₹69.3 L | L1 | Admitted-Finance |
| 2 | L2₹70.4 LAdmitted-Finance | ₹70.4 L | L2 | Admitted-Finance |
| 3 | L3₹71.3 LAdmitted-Finance | ₹71.3 L | L3 | Admitted-Finance |
| 4 | L4₹73.2 LAdmitted-Finance | ₹73.2 L | L4 | Admitted-Finance |
| 5 | L5₹76.5 LAdmitted-Finance | ₹76.5 L | L5 | Admitted-Finance |
Tender Value
₹86.1 L
EMD Value
₹1.7 L
Closing Date
25 Feb 2026, 6:00 pmClosed
EE PWD DN SHAHPURA
Construction of CC Road in Various Street in Uncha
Construction of CC Road in Various Street in Uncha
2026_CEPWD_538314_16
ONLINE NIT No 21/2025-26 EE PWD Dn SHAHPURA
Open Tender
Civil Works
120 days
Jahazpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
5776 EE PWD DN SHAHPURA
₹1.7 L
Yes
27 Feb 2026
16 Feb 2026
26 Feb 2026
16 Feb 2026
25 Feb 2026
16 Feb 2026
Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905. 600 mm dia
Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 602.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.5 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed Side Formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using water finishing to lines and grade as per drawing and MoRTH Specification Clause 602 including vaccum dewatering process with all required equipments (Dowel Bars will be paid seprately)
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905. 300 mm dia
Earthwork in excavation for structures as per drawing and MoRTH specifications Clause 304.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRTH specifications Clause 1702, 1703, 2102 & 2104 P.C.C grade M 10 Nominal mix 1:3:6
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRTH specifications Clause 1702, 1703, 2102 & 2104 R.C.C grade M 20
Supply & fixing of Fiber reinforced Ferro cement drain cover (light duty) designed for side drain for class "B" Road loading duly marked on cover with adequate steel reinforcement having thickness 50 mm to 75 mm anti corrosive bitumen painted M.S. plate Rim and on M.S. lifting hooks additives & admixture like plasticizer shrinkage resistance compound abrasion resistant as per approved drawing and design complete in all respect.for drain Opeining Size 300 to 450 mm Standard Drain Cover Size 600mm x 1200mm x 50mm
Earthwork in excavation for structures as per drawing and MoRTH specifications Clause 304.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRTH specifications Clause 1702, 1703, 2102 & 2104 P.C.C grade M 10 Nominal mix 1:3:6
Stone masonry work in cement mortar in foundation complete as per drawing and MoRTH specifications Clauses 1402, 1405, 2102 & 2104. Random Rubble Masonry In 1:6 cement mortar
Plastering with cement mortar (1:4), 20 mm thick on Stone work.
Plain/reinforced cement concrete in substructure complete as per drawings and MoRTH specification Clauses 1700 and 2200 For height upto 5 m P.C.C grade M 15 Nominal mix (1:2.5:5)
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 2905. 1000 mm dia
Construction of speed breaker of IRC standard having width of 3.70 M including cost of stone aggregate (50-25mm) size hire charges for roller for consolidation and compaction and other machines required for the work (including cost of bitumen)
Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 801.3.1. fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 x 450 x 600 mm, 600 mm below ground level as per approved drawing and MoRTH Specification Clause 801. Direction and Place Identification signs upto 0.9 sqm size board
Construction of Foundation / Inaugration Pedastal in 23 cm thick Brick masonry in CM 1:4 of size 1.20m x 1.80m above ground level with adequate foundation including providing and fixing of Granite stone of size 0.75m x0.60m with engraving letters and figures,cement plaster,white washing etc. complete as per direction of Engineer in charge.
Providing and fixing Mukhya Mantri Sadak Yojana/ Mahatma Gandhi Rajya Sadak Yojana informatory sign board with logo for roads funded by State road fund having M.S. Definition plate of 1.60 mm thickness frame to steel hollow dsection of 75mm x 75mm, 2.5m long stove enamelled paint with hold fast including paint logo as per approved design and colours. The logo shall be made out of 1.6mm thick circular plate duly framed with MS angle 25x25x5 mm on back and fix on 1200mm x 150mm rectangular steel base plate 1.6mm thick, the base of circular shall be plain at the junction of base plate. The size of definition plate shall be 1500x600mm and embedding the posts by M-15 cement concrete block 45 cm x 45 cm x 60 cm, 60 cm below ground level including lettering / writing and painting etc. complete in all respect.as per MoRTH Specification Clause 801.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.42 MB
Tendernotice_2.pdf
PDF • 2.39 MB
Tendernotice_3.pdf
PDF • 15.81 MB
Tendernotice_4.pdf
PDF • 2.90 MB
Tendernotice_5.pdf
PDF • 0.22 MB
Tendernotice_6.pdf
PDF • 5.64 MB
16.pdf
Tender Documents • 0.16 MB
BOQ_960232.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid