| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC | ₹2.6 Cr Quoted ₹2.7 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹2.7 Cr+₹5.2 L (1.91%)Rejected-Finance OFFICE NO 304 305 3RD FLOOR PLOT NO 1 USHA CHAMBERS L S C NEW RAJDHANI ENCLAVE DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹2.7 Cr+₹5.2 L (1.91%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹2.8 Cr+₹14.8 L (5.51%)Rejected-Finance 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹2.8 Cr+₹14.8 L (5.51%) | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹2.3 Cr
EMD Value
₹3.0 L
Closing Date
9 Jun 2021, 6:00 pmClosed
CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM DELHI CANTT-10
PROVISION OF DEFICIENT LIVING IN ACCOMODATION FOR SNCOS AT CAMERO SNCOs MESS AT SUBROTO PARK
2021_MES_414798_2
CEWAC/PAL/T-30/2020-21
Open Tender
Civil Works
Lump-sum
426 days
GE (AF) SUBROTO PARK
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE (AF) SUBROTO PARK
₹3.0 L
27 Oct 2021
6 May 2021
11 Jun 2021
6 May 2021
9 Jun 2021
27 May 2021
6 May 2021 - 15 May 2021
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Construction of single living accomodation for SNCOs four storey (G+3) building with permanent specifications complete all as specefied as shown on drawings.
NOTE: Schedule ‘A’ Part II to XII under are Prepriced by MES.
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION"” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “AREA DRAINAGE WORK” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “ PATH AND HARDSTANDING " as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-VIII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “HOT WATER SUPPLY" as listed in Schedule ‘A’ Part X
Lump sum price worked out by the Contractor for “DEMOLITION AND DISMANTLING" as listed in Schedule ‘A’ Part XI
SCHEDULE `A' PART - XIII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
INTERNAL ELECTRIFICATION
Supply & Fixing LED security light fitting 45 watt, high pressure die cast aluminium housing, heat resistant toughened glass with frame , IP66 protection complete with lamp & connected items and connection with suitabel cabel from ceiling rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grade 1.2 mtr long bent to shape and fixed on wall with flat iron clamps, nut, bolts washer etc all as specified and directed.
Supply and fix in replacement of MCCB vertical distribution board, 4 way TP , IP 43 protection, factory made sheet steel, phosphates, poweder painted with 200 Amps rates bas bar, 415 volts, neeutral link, earth bar and Din rail singledoor, neutral bar and pan assembly with connecting link and suitable to accomodate one No TP 125 Amps, 35KA, 415 volt MCCB as incomer and MCB SP as outgoings compelte all as specified. Make L&T/legrand/Schneider. (Note: MCBs & MCCBs will be measured and paid separately under respective items)
S&F MCB DP upto 40-63 Amps 240 Volts 10 KA 'C' curve type compelte all as specified.
S&F MCB SP 40 to 63 Amps 240 Votls 10 KA 'C' curve type complete all as specified.
S&F MCB 4 Pole 40 to 63 Amps 240 volts 10 KA 'C' curve type compelte all as specified.
S&F MCCB FP adjustable (70-100%) 125 Amps, 35 KA, 415 volts compelte. all as specified.
S&F MCB 3 Pole 40 to 63 Amps 240 vo;ts, 10 KA 'C' curve type compelte. all as specified.
AC & E/M MISC SERVICES
Supply installation commissioning of water cooler fully stainless steel electric driven single phase having approx storage and nominal cooling capaicty 80/40 LTRS (or nearest higher size) with minimum 3 star rating suitabel for CFC free refrigerant single phase 230 V 50 HZ complete with provn of drain water pipe of suitable dia and accessories complete all as specified and directed.
Supply & install floor/ wall mounted votlage stabilzer for Automaic operation single phase as per BIS 8448: 1989 reaffirmed 2003 air cooled digital disply copper wound indoor type with digital voltmeter & designed for input voltage variation between 140 to 280 volt with output voltage stabized at 230+/- 09% with time delay relay (TDR) of 2 to 3 minutes and high low voltage cut off and of capacity 1 KVA compelte all as specified as directed by Engineer-in-Charege.
Supply and fix Galvanised iron sheet body desert cooler electric driven (singel phase) 3 speed, 230 V, 950 RPM axial fan type and pumping system having nominal air flow capacity of 4000 Cum per hour (or nearest size) and knob operating system and providing of piano type switch for ON/Off and for pumping system including cooler stand made from angle iron 50 x 50 x 6 mm frame of appropriate size to fix cooler in window duly painted with two coats over a coat of red oxide compelte all as specified and directed by Engg-in-Charge.
SOLAR WATER HEATER
Supply, installation, testing & commissioning of solar water heating system based on indirect type with electric back up 6 kw of cap 600 Itr per day at temperature 60 degree centigrade including suitable flat plate collectors ISI marked size 1860 mmx1240mmx100 mm having insulation of rock wool/mineral wool 50 mm thickness at bottom and 25 mm thickness on sides with toughned/ tepered glass of 3.2 mm thick and back sheet of aluminum with hot water storage tank of capacity 600 Itrs or as per having manufacturer recommendations and of 20 gauge thickness stainless steel 304 plate having insulation of PUF 50 mm thick and cladding with color coated Gl sheet 0.4 mm with stand for collector stagging of suitable height (for easy flow of water) for hot water made out of 35x35x4 mm angle iron complete with temperature gauge 0 to 100 degree C, backup heater, PVC cold water tank of capacity 600 Itrs, with necessary ball cock, with MS stands of suitable height for gravity flow of water from cold water to solar hot water tank with necessary civil work as per manufacturers recommendation complete all as specified and directed.
EXTERNAL ELECTRIFICATION
M&L for fabricate, supply and instalation cubic type CPRI approved LT Panel board, outdoor type totaiiy enclosed dust and vermin proof (protection class IP-65) front opening with self locking arrangement made out of MS angle iron frame work 50x50x6mm, MS fiat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 (volts 50 Hz, 3 phase 4 wire system and shall be complete with 400 amp capacity copper bus bar, wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected accessories required for functioning of panel board such as thimbles, glands, bolts, nuts, washers etc including necessary earth work for foundation work and foundation PCC with grouting bolts and nuts complete including supply and fixing following accessories:-
Incomings: (a) MCCB, 4 pole, 200 amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 35 KA – 01 No (incoming) (b) Multi functional digital type meter with 03 Nos CTs of ratio 200/5- No 01 (c) LED type indicator lamp set of red, yellow and blue Set 01 Outgoing (a) MCCB, 4 pole, 160 amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 25 KA-01 Nos (b) MCCB, 3 pole, 100 amp current carrying capacity, 50 Hz, 415 volt with rupturing capacity 16 KA – 02 Nos (c ) Spare space for incoporating MCB TPN 32 Amps - 01 No. (d) Spare space for incoporating MCB TPN 100 Amps - 01 No.
EXTERNAL WATERSUPPLY
M&L for construction of masonry valve pit of size 100 x 100 x 100 cm (internal dimensions ) depth to reconed from the top of PPC in foundation, including mild steel sheet cover 3mm thick over angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer, locking & fixing arrangement and brick work and all inner sides of pit shall be plastered cement mortar (1:4) and including foundation concrete (1:4:8) type D-2 using stone aggregate, excavation in soft/loose soil, returning filling, disposal of surplus soil within 50 metre and cement concrete(1:2:4) type B-O as in coping etc. for sluice valve complete all as shown on drawing and as specified.
DEMOLITION AND DISMENTLING
Taking down the old perished meter board and DBs, MCBs any type by necessary cutting, chasses including disconnecting of in coming and outgoing cable etc complete all as specified and directed.
Taking down the old tube light fitting single / double rod , CFL fitting and bulk head fitting of any type complete all as specified and directed.
Disconnecting and taking down unserviceable service connection / cable of any size from pole / main switch board complete all as specified.
Taking out care fully earthing set complete of any type incl earthing wire / strip complete all as specified and directed.
Removing building materials / rubbish (other than spoil payable under disposal of earth) out side of MOD land including loading, unloading and stacking at the destination complete all as specified and directed.
G and G Infratech Private Limited
Leo Network power systems
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .