Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Oct 2026, 6:00 pm
CWE (AF) Jammu
HQ CWE (AF) Jammu Air Force Station Jammu
CA NO CWEAFJ-33/2026-27 REPAIR/MAINTENANCE OF ACSR, ABC, XLPE CABLE ALONGWITH 2 POLE, 4 POLE STRUCTURE OF 11 KV AND 33 KV VCBs AND ALLIED WORKS AT AF STATION UDHAMPUR UNDER GE (AF) UDHAMPUR
2026_MES_789888_1
CA NO CWEAFJ-33/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Udhampur
As per NIT and Tender document
9 documents required · 9 mandatory
₹500
GE (AF) Udhampur
₹80,000
Yes
17 Sept 2026
17 Sept 2026
10 Oct 2026
17 Sept 2026
8 Oct 2026
1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour for calibration of 33KV control and relay panel including testing of all protection relays, energy meter and transducer against secondary injection kits(Omicron/freja) and certifying that 33KV VCB is tripping accurately during faults also checking the polarity of RYB phase, calibration certificate should have one year validity backed by National Accredition Board for Testing and Calibration Laborsteries(NABL) complete all as specified and directed by Engr-in-chrage. | 2 | Each job | 1.25 | ₹2.5 |
| 2 | Labour for calibration of 11kV RMU/VCB including testing of all protection relays, meter and transducer against secondary injection kits(Omicron/freja) and certifying that 11kV VCB/RMU is tripping accurately during faults also checking the polarity of RYB phase, calibration certificate should have one year validity backed by National Accredition Board for Testing and Calibration Laborsteries(NABL) complete all as specified and directed by Engr-in-chrage. | 15 | Each job | - | - |
| 3 | Periodical / Routine Serving of control panel of 33 KV rating in such as checking of all wiring connection of differential relay and auxiliary relays and blowing out dust, calibration of relay & repair and replacement of defective components as per existing Make / Model / Capacity of 33/11 KV CR Panel including connecting the all electrical connection and testing complete all as specified and directed by Engr-in-chrage.
Notes :-
1. The above job to be carried out by engineer of authorised dealer / Service Centre of concerned OEM.
2. Replacement of defective items shall be measured and paid separately as supply only. The labour charges for fixing of the same shall be deemed to be included in this item.
3. The contractor shall arrange for the standby supply for testing of relays etc. | 2 | Each job | -1.25 | - |
| 3.01 | Fixing only in repairs Test terminal block as per existing Make / Model / Capacity complete all as specified and directed by Engr-in-chrage. | 1 | Each | -2.5 | - |
| 3.02 | Fixing only in repairs DC supervision relay as per existing Make / Model / Capacity complete all as specified and directed by Engr-in-chrage. | 1 | Each | -3.75 | - |
| 3.03 | Fixing only in repairs AC supervision relay as per existing Make / Model / Capacity complete all as specified and directed by Engr-in-chrage. | 1 | Each | -5 | - |
| 3.04 | Fixing only in repairs Kit Kat fuse as per existing Make / Model / Capacity complete all as specified and directed by Engr-in-chrage. | 2 | Each | -6.25 | - |
| 3.05 | Fixing only in repairs winding temp alarm relay as per existing Make / Model / Capacity complete all as specified and directed by Engr-in-chrage. | 1 | Each | -7.5 | - |
| 3.06 | Fixing only in repairs supervision relay for trip circuit as per existing Make / Model / Capacity complete all as specified and directed by Engr-in-chrage. | 1 | Each | -8.75 | - |
| 3.07 | Fixing only in repairs Master trip relay as per existing Make / Model / Capacity complete all as specified and directed by Engr-in-chrage. | 1 | Each | -10 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
33TENDERDOC.pdf
Tender Documents • 0.77 MB
BOQ_885466.xls
BOQ • 0.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .