Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC | ₹30.1 L Quoted ₹30.9 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹50.2 L+₹19.3 L (62.4%)Rejected-Finance SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | ₹50.2 L+₹19.3 L (62.4%) | L2 | Rejected-Finance BEING NOT L1 |
| Sl No | Description | Qty | Unit | DIAMOND ENTERPRISES L1 | Shree Sai Samarth Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | M&L for periodical repair, maintenance & overhauling of 11 KV HT VCB 630/800 Amp including opening, checking, cleaning with CTC, cleaning wiping of insulating component, incl primary & secondary current enjection test , Insulation resistance test Primary to secondary & Primary to earth and report to be submitted , cleaning of spouts, busbars, supports, CT, PT, cleaning contact tips, cover the expossed portion of busbar with HT tape & heat shrinkable sleeves, spout insulators for visible crack, tightness of fasterners holding moving contacts, check & correct the buffer gap adjustment & mechanism settings, meters. Testing and calibration of all relays fitted in control panels from authorized testing team of the OEM, such as earth fault relays, over current relays fitted in HT 11 KV panels for its corrections & setting with main control panel relays & MSEDCL so that individual VCB shall be tripped prior to main panel, contractor shall submit testing and calibration report showing all set parameters. Testing, cleaning & overhauling of complete operating mechanism for smooth functioning, checking of control panel wiring for operation & protection for tripping & closing & rectifying the defects all equipments including Deoxidizing of all electrical contacts replacement unserviceable wiring with ferrule & lugs, reassembling & testing of complete VCB all as directed specified and directed by Engineer in Charge
Note:- i) Required spare parts for replacement will be measured and paid under relivant item as supply only. Item No-2 to 36 ii) Cost of Labour for replacement is demed to be included under this item.
Iii) Repairs to be carried out by OEM Authorized agency only. | 42 | Job | 7,950 ₹3,33,900 Lowest | 9,400 ₹3,94,800 |
| 2.00 | Supply Only Trip Catch Assembly | 2 | Each | 5,000 ₹10,000 Lowest | 11,250 ₹22,500 |
| 3.00 | Supply Only Trip Shaft Assembly. | 4 | Each | 1,600 ₹6,400 Lowest | 3,150 ₹12,600 |
| 4.00 | Supply Only closing shaft Assembly. | 4 | Each | 1,600 ₹6,400 Lowest | 3,250 ₹13,000 |
| 5.00 | Supply Only Spring charge Indicator Assembly. | 4 | Each | 1,500 ₹6,000 Lowest | 2,550 ₹10,200 |
| 6.00 | Supply Only Motor cut off limit switch Assembly. | 4 | Each | 1,800 ₹7,200 Lowest | 3,050 ₹12,200 |
| 7.00 | Supply Only Spring charging handle. | 4 | Each | 2,200 ₹8,800 Lowest | 4,400 ₹17,600 |
| 8.00 | Supply Only Closing Coil Assembly, DC. 12Voltage. | 3 | Each | 2,200 ₹6,600 Lowest | 4,300 ₹12,900 |
| 9.00 | Supply Only Tripping Coil Assemblyy, DC 12.Voltage. | 4 | Each | 2,100 ₹8,400 Lowest | 5,890 ₹23,560 |
| 10.00 | Supply Only Auxiliary switch 6 NO/6NC. | 4 | Each | 2,100 ₹8,400 Lowest | 5,690 ₹22,760 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Mar 2025, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIRS / MAINT OF HT OVER HEAD LINE, HT CABLE, GOD, POWER TRANSFORMER, DISTRIBUTION TRANSFORMER, HT VCB, HT OCB PANEL AND OTHER CONNECTED WORK AT 11 BRD AF STN OJHAR
2025_MES_697707_2
8265/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹90,000
Yes
13 Oct 2025
25 Feb 2025
19 Mar 2025
26 Feb 2025
17 Mar 2025
27 Feb 2025
Amount
M&L for periodical repair, maintenance & overhauling of 11 KV HT VCB 630/800 Amp including opening, checking, cleaning with CTC, cleaning wiping of insulating component, incl primary & secondary current enjection test , Insulation resistance test Primary to secondary & Primary to earth and report to be submitted , cleaning of spouts, busbars, supports, CT, PT, cleaning contact tips, cover the expossed portion of busbar with HT tape & heat shrinkable sleeves, spout insulators for visible crack, tightness of fasterners holding moving contacts, check & correct the buffer gap adjustment & mechanism settings, meters. Testing and calibration of all relays fitted in control panels from authorized testing team of the OEM, such as earth fault relays, over current relays fitted in HT 11 KV panels for its corrections & setting with main control panel relays & MSEDCL so that individual VCB shall be tripped prior to main panel, contractor shall submit testing and calibration report showing all set parameters. Testing, cleaning & overhauling of complete operating mechanism for smooth functioning, checking of control panel wiring for operation & protection for tripping & closing & rectifying the defects all equipments including Deoxidizing of all electrical contacts replacement unserviceable wiring with ferrule & lugs, reassembling & testing of complete VCB all as directed specified and directed by Engineer in Charge Note:- i) Required spare parts for replacement will be measured and paid under relivant item as supply only. Item No-2 to 36 ii) Cost of Labour for replacement is demed to be included under this item. Iii) Repairs to be carried out by OEM Authorized agency only.
Supply Only Trip Catch Assembly
Supply Only Trip Shaft Assembly.
Supply Only closing shaft Assembly.
Supply Only Spring charge Indicator Assembly.
Supply Only Motor cut off limit switch Assembly.
Supply Only Spring charging handle.
Supply Only Closing Coil Assembly, DC. 12Voltage.
Supply Only Tripping Coil Assemblyy, DC 12.Voltage.
Supply Only Auxiliary switch 6 NO/6NC.
Supply Only Indicating VCB Lamps (RYB) LED type of Shape & Size as per existing complete all as directed. MAKE : TENICK / L&T or equivalent .
Supply Only Push Button element with one NO / NC MAKE : TENICK / L&T or equivelent.
Supply Only HRC Fuse for PTs 11 KV capacity 1 to 16 Amp.
Supply only warm Gear Wheel with Main Shaft Assembly any type
Supply only insulated VI Seprators
Supply only Big Cam Assembly , VCB
Supply only Closing Spring Assembly
Supply only Tripping Spring Assembly
Supply only 32 pin plug socket Assembly
Supply only TNC switch
Supply only Anti Pumping Device
Supply only Z-Z Micro Switch
Supply only support Insulator
Supply only Drive link with Adjuster
Supply only Test service Limit Switch
Supply only PT fuse 3.15 Amp
Supply only (VCB) Heater Single Ph, 230 V, AC
Supply only Digital Volt meter 11 KV
Supply only Digital Ampmeter 11 KV
Supply and fixing 11 KV Epoxy resin cast indoor gun type single phase potential transformer ratio 11 KV/ 3 Accuracy class-0.5 and 3 P, burden-10 A 50 Hz, bill-12/28 and VF-1.2 Cont 1.9 or 8 hrs with PT fuse 3.15 Amp suitable for Existing 11 KV VCB make Crompton 630 Amp.
Supply and fixing Current Transformer duel core Class - SP10 & Class - I, VA - 15, 11 KV 25/5 and 50/5 Amps resine casting.
Supply and fixing Current Transformer duel core Class - SP10 & Class - I, VA - 15, 11 KV 100/5 Amps resine casting.
Supply and fixing spring charging motor retrofit. For HT VCB 11 KV Make CG, or equivalent
Supply and fixing Vaccum Interruptor , single phase, 11 KV Make CG, or equivalent
Supply and fixing power pack with batter back up suitable for HT VCB 11 KV input voltage 230/110 AC, Output 24/30/48/110/220 V DC , back up 15-20 minutes with LED Indicator.
M&L for maintenance & overhauling of 11 KV OCB including opening, checking, cleaning, wiping of insulating component, primary & secondary circuits, busbars, supports, CT, PT, cleaning contact tips, cover the expossed portion of busbar with HT tape & heat shrinkable sleeves, cleaning of oil tank, tightness of fasterners holding moving contacts, check & correct the buffer gap adjustment & mechanism settings, meters, & Testing and calibration of all relays fitted in control panels from authorized testing team of the OEM, such as earth fault relays, over current relays fitted in HT 11 KV panels for its corrections & setting with main control panel relays so that individual OCB shall be tripped prior to main panel, contractor shall submit testing and calibration report showing all set parameters, testing, cleaning & overhauling of complete operating mechanism for smooth functioning, checking of control panel wiring for operation & protection for tripping & closing & rectifying the defects all equipments including Deoxidizing of all electrical contacts replacement unserviceable wiring with ferrule & lugs, and other minor parts as reqd at site reassembling & testing of complete OCB all as directed specified and directed by Engineer in Charge .
Supply and fix three phase over current & earth relay, Model- CGI 14N in CG or equvalent, with 3 phase O/C + E/F + High set, 50/51 RYBN, Numerical Relay, Lowest O.C-1s, Highest O/C-1hs, Lower D/F-0s, Highest E/F Ohs, including calibration of relay with existing system so that fault can be arrested in individual panel, all as specified and directed.
Supply, installation, testing and commissionig Battery bank 24 volt,( 12X2V) , 80AH at 10 Hrs discharge rate, self contained, floor mounted, sheet steel, cabinet with two tiers for housing and including low maint batteries with battery charger unit Make: Exide - Model No. UPST-24V-80Ah - sealed maintenance free VRLA battery, initialy charged complete with all accessaries suitable for DC supply of HT VCB, operated from 415 v, 3 phase, 50 Hz ,AC supply.
Supply and fixing Battery charger unit 24V/10 Amp with displayMake: Exide - Model No. UPST-24V-80Ah complete with all accessaries suitable for DC supply of HT VCB, operated from 415 v, 3 phase, 50 Hz ,AC supply.
M & L for Breakdown Maintenance of 11 KV HT VCB/OCB 630/800 Amp including Testing and calibration of all relays fitted in control panels from authorized testing team of the OEM, for smooth functioning, checking & rectifying the defects of all equipments complete all as directed specified and directed by Engineer in Charge .
M&L for Onload filtration and dehydration of transformer oil by on load filtration plant machine to achive minimum 40 KV dielectric strength complete and submitted the testing repot of the dielectric strength and contents of acid before and after filtration at different locations of 11 KV / 440 V installations all as specified and as directed by the Engineer in charge.
M&L for Filling only new transformer oil for topping up or replacement of transformer oil in the OCB, Oil switch, transformers 11 KV / 440 V at different locations during the process of filtration, all as directed and specified.
Disconnected earthing strip from transformer body and neutral at site . Testing of earth resistance of each earthing of transformer (Neutral and Body earthing ) and report to be submitted at AGE E/M Office complete all as directed by Engr in Charge up to 1000 KVA transformer
Disconnected electric supply of transformer at site and Opening the cable box HT& LT side and carried out the insulation resistance test HV to LV and LV to LV of each type of transformer and re-assembleing the same and report to be submitted at AGE E/M Office complete all as directed by Engr in Charge up to 1000 KVA transformer
Taking down carefully transformer at site and dismantling / Opening the same and taking out coil and core assemebly through reputed firm to be approved by GE and carried out minor repair such as as replacement of HV/LV Bushing, termination rod, nut bolts, gaskets etc and re-fixing in position including testing of present di-electric strength of transformer oil and re-assembleing the same complete all as directed by Engr in Charge up to 500 KVA transformer
Supply only non metel Part- HV bushing complete with packing for transformer of capacity up to 500 KVA and for working pressure 11 KV complete all as specified and as directed by Engr-in-charge.
Supply of HT Bushing rod of suitable size for transformer of capacity up to 500 KVA
Supply only non metel Part- LV bushing complete with packing for transformer of capacity up to 500 KVA and for working pressure 11 KV complete all as specified and as directed by Engr-in-charge.
Supply of LT Bushing rod of suitable size for transformer of capacity up to 500 KVA
Supply only main gasket of transformer and other gasket set complete all as specified and directed by Engineer-inCharge
Taking down unserviceable transofrmer and transporting from site / AGE E/M Yard to civil work shop for repair by reputed firm ( As approved by GE) Opening the same including taking out coil and core assembly, cleaning and segregate the damaged parts and replacing with brand new parts as directed and Making the transformer ready for use compete including refilling the dehydrated transformer oil and transporting the transformer back to site, fixing in position and commissioning at site complete in all respect capacity up to 500 KVA transformer. Note- spares parts will be measured and separately.
All as per item No 53 but 750 and 1000 KVA Transformer complete all as specified and as direcetd by E ngr-in-charge
Material and labour super enameled copper winding wire for rewinding of HV side of transformer as per original gauge incuding insulating material such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer complete all as specified and as direcetd by E ngr-in-charge
Material and labour super enameled copper winding wire for rewinding of LV side of transformer as per original gauge incuding insulating material such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer complete all as specified and as direcetd by E ngr-in-charge
M & L for replacement of silica gel in breathers of transformers of various capacities including taking down of unserviceable silica gel complete all as directed by Engineer-in-charge
S&F breather assembly air tight made out of metal body and transparent acrylic glass suitable for various sizes of transformer.
S&F dial type thermometer for measuring winding /oil temperature of transformer and including taking down old UNSV dial type thermometer from the pocket to safe custody.
Maintenance of GOD fixed on two/four pole structure including cleaning and greasing the all connected parts and replacement of HT jumper-3 nos , alligning of GOD and replacement of male and female brass contacts -3 set of 200 Amp incl all repair and maintenance of of GOD for smooth functioning all as specified and directed by the Engr In charge.
Taking down serviceable VCB 11 KV after disconnecting of all electrical connection Making suitable size of base stand ( as designed by engr-in-charge. for 11 KV HT VCB Dismantling of old and unservicable cross arms and M&L for cross arms, bracings, supports, clamps and back plates fabricated from strucural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated, with & inclusive of one coat red oxide primer & one under coat and one finishing coat of synthetic enamel paint after preperation of surfaces all as soecified, as directed by engg in charge.
Dismantling of old and unservicable cross arms and M&L for cross arms, bracings, supports, clamps and back plates fabricated from strucural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated, with & inclusive of one coat red oxide primer & one under coat and one finishing coat of synthetic enamel paint after preperation of surfaces all as soecified, as directed by engg in charge.
S& F in reapairs Air Break switch, gang operated triple pole mechanically operated mounted on insulator and steel frame with operating mechanism and locking arrangement worked from ground level for current rating up to 200 amps,11000 volts all including fix and moving contacts, post insulators, operating rod, handle etc complete with necessary connections/ jumpers with suitable ACSR conductor with heavy duty alkathine pipe all as specified by Engineer in charge Make:- jaipuria/Pactil.
S& F in reapairs DO Fuse 100 Amp 11 KV complete with necessary connections/ jumpers with suitable ACSR conductor all as specified by Engineer in charge Make:- jaipuria/Pactil.
Supply and fixing in replacement of 30 nos IR lamp (infra red heating lamp) 250 watt for Heat pillar, incandescent type BR125 shape hard glass with E 27 base product code BR125 IR 250 W-E27 230-250V CL ICT/10 threaded type Make-Phillips including 03 nos dimmer on each phase as required at site.
Supply & fix jointing and testing in replacement HT cable jointing kit for 11 KV(earthed) grade cable heat shrink for end termination out door type joint complete with jointing matrial and accessaries suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
All same as per item no. 66 here-in before but cable of size 120 Sqmm to 185 Sqmm.
All same as per item no. 66 here in before but for indoor type end termination joints for cable size of 50 to 95 Sqmm.
All same as per item no. 68 here in before but 120 sqmm to 185 sqmm
All same as per item no. 66 here-in before but for straight through type joints for 50 to 95 Sqmm cable.
All same as per item no. 66 here-in before but for straight through type joints for 120 to 185 Sqmm cable.
Material and labour for locating under ground cable fault (HT /LT) within 06 hrs including Sunday or any holiday using cable fault locator machine taking all necessary precautions as directed by Engr-in-charge. Note : The HT cable passing through dence farest JCB must be rquired for excavation of cable and surface cleaning for fault finding If fault not located by the contractor within specified time a recovery of an amount of Rs. 5000/- will be recovered per day.
Material and labour for Painting of transformer 11KV/433V Indoor/Outdoor type with two coat of synthetic enamel grey paint after cleaning and scraping of old paint, oil, rust etc complete including writing SM Nos with white synthetic enameled paint complete all as per specified as directed by Engineer - in - charge of the 500 KVA to 750 KVA Capacity.
All as per item No- 73 but 250 KVA to 200 KVA
All as per item No- 73 but 100 KVA to 25 KVA
M & L for manual scraping of old painted surface and providing spray painting as per existing colour with one coat of synthetic enamelled paint of existing colour on outer surface of VCB including writing SM No and MES No. on VCB Body, complete all as Directed by Engineer-In-Charge
Supply and mild steel plates chequerred channels, square cut or notched ( ordinary and counter sunk) forming holes without any attachment of steel Fe - 410W ( Gde-E-250) quality - B as in florring and is supproting members of required size and section duly cutting and welding with foundation etc all as directed by Engineer - in - charge.
Material and labour for cable joint/root indicator casted in 560X180X40 CM PCC tile duly engraved with 'HT CABLE/LT CABLE / HT CABLE JOINT" in letters duly fixed into the ground with to th minimum depth of 450 mm, PCC casting (1:4:8), type D2 with 20 mm graded stone aggregate minimum size of PCC,duly painted, complete all as specified and as directed by Engneer-in-Charge.
Supply & laying in trenchs or passing through pipe, fixed to pole or as indicated at site, commissioning and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (earthed) with stranded aluminium conductor,11000 volts, grade of size 3 core 95 Sqmm complete all as specified and as directed by Engr-in-Charge including taking out U/S HT Cable
All as per item No 79 here-in-before above but 3 core 120 Sqmm
All as per item No 79 here-in-before above but 3 core 185 Sqmm ( near HAL pound )
Taking down old existing cable 120/95 sqmm 3 core from trench rectified the defects and relaying/reouting of the same complete all as specified and as directed by Engr-in-Charge (Note- HT joints will be measured and paid separately.and excavation and earth work will be measured and paid separately)
M&L for cleaning the cable duct at 11 KV sub stn by taking out old existing seviceable 11 KV HT cable 120/95 sqmm 3 core from cable duct by opening of cable duct cover removing the soil/ dust etc ,cleaning the duct /trench and keeping the duct cover on its original position complete all as specified and as directed by Engr-in-Charge
Excavation in trenches carefully for taking out or relaying existing/ new servicable HTUG cable not. exceeding 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in soft/loose soil all as directed by Engr-in-Charge.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm all as specified and as directed.
Removing of surplus soil to a distance not exceeding 50 mtr and depositing in low lavel where directed at a level not exceeding 1.5 mtr above the starting point all as directed by Engr-in-Chagre.
M&L river sand cushioning/filling completely dry in trenches 8cm below the cable and 15 cm abobe the cable and punned down to a total thicknes of sand 18 cm cpmplete all as specified and as directed by Engr-in-Charge.
Supply and fixing un-reinforced precast concrete cable covers class HV,type 1 flat of size 300x180x40 mm from excaveted trench under srl item No.1 herein before and staking properly aside for reuse to a distance not existing 50 mtr as directed at site by Engr-in-Charge.
Supply and fix 80mm dia bore galvanized iron tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc all as specified and directed.Make- Prakesh surya/Swastik/Jindal.
M&L for Boring of holes under Road, Pavements, Hard Standing by manually at a depth 0.6 Mtr from top surface complete all as specified and directed by Engineer-in- Charge.
M&L for Trenchless boring of holes under Road, Pavements, Hard Standing by trench less machine and provode at a depth 0.6 Mtr from top surface complete all as specified and directed by Engineer-in- Charge.
Supply & fix earth continuty conductor or main earthing copper strip of 32X6 mm dia for VCB earthing connection as required all as directed by Engg. in charge. Note :- i) the distance between porcelain insulator will be included .
Supply and fixing for Outdoor Floor Mounted cubical Feeder Piller Box of size 60 mm X 95mm X 120 mm , self supported, front & rear openable, double door ,hinged type with locking arrangement & sloping top canopy ,suitable ventilation on both side, with wire mesh, IP52 protection with Dust & Vermin proof etc made of 3.15 mm CRCA sheet duly powder coated , mounted/fixed on MS Angle iron 40x40x5 mm thick duly painted with black enamel synthetic paint over coat of red oxide zink chrome primer, duly grouted in PCC 1:3:6 Type C1 using foundation ,suitable size of MS Gland with gland plate, and aluminum lugs/ for all incoming and outgoing cables ,etc, complete all as directed.
M&L grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots , filling holes and levelling off ground, stacking of serviceable material and removing of serviceable /unserviceable materials to a distance n exc 50 m and clearing site complete all as directed.
Supply and laying High voltage insulation electric mat 3.0 mm thick fot voltage up to 11 KV for electrical pupose as per IS IS-15652-2006 (superseding IS 5424) suitable for electrical shock safty of various sizes complete all as directed.
M&L for spraying the chemical in sub stn areas Tech area , Domestic area and raksh nagar (total 3 location ) for buring of the grass once in three month complete all as directed.
Shree Sai Samarth Enterprises (BID ID -3254557)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .