Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC SHIVAJI NAGAR GALI NO 1 DHANGU ROAD MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹5.8 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹5.9 LRejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | ₹5.9 L | L2 | Rejected-Finance Not being lowest tender |
| 3 | L3₹9.7 LRejected-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | ₹9.7 L | L3 | Rejected-Finance Not being lowest tender |
| Sl No | Description | Qty | Unit | Unitech Enterprises L2 | KEWAL SONS L1 | GANGAJAL L3 |
|---|---|---|---|---|---|---|
| 1.00 | Chipping ,removing carefully concrete work by low impact hammer ,breaker without damaging the structure & cleaning and disposal of debris out side the premises etc. complete as directed by Engr-in-Charge. Hard concrete should not be removed by force. | 500 | Sqm | 15 ₹7,500 | 50 ₹25,000 | 47 ₹23,500 |
| 2.00 | Taking down cement plaster, any description on brick or stone surfaces, etc including racking out joints hacking for key scrubbing down with water etc and removal of debris outside MD land. | 200 | Sqm | 20 ₹4,000 | 20 ₹4,000 | 27 ₹5,400 |
| 3.00 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of any description in CM (1:4)with Ready mix plaster mixed with liquid water proofing compound and finished even & smooth without using extra cement completed all as specified. (Note : WPC will be measured and paid separately) | 943 | Sqm | 140 ₹1.3 L | 180 ₹1.7 L | 200 ₹1.9 L |
| 4.00 | Supply only liquid water proofing compound of approved make | 12 | ltr | 100 ₹1,200 | 400 ₹4,800 | 310 ₹3,720 |
| 5.00 | M & L for clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete, Applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem of Roff rust cleaner of Pidilite or Dr Fixit Rust removal or sholirust of STP Ltd. on the rebars,including cleaning the reinforcement ,wire brushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry. | 500 | Sqm | 50 ₹25,000 | 50 ₹25,000 | 140 ₹70,000 |
| 6.00 | M & L for providing and fixing additional steel bar or stirrups of diameter in variuos structural elements like columns,beams and foundations including drilling,bending and fixing the bars with epoxy putty etc. complete as directed by Engr-in-Charge. | 80 | KG | 70 ₹5,600 | 70 ₹5,600 | 88 ₹7,040 |
| 7.00 | M & L for applying two coats of anticorrosive Treatment to Reinforcement by application of two coats of anti-rust protective coating in the form of Acrylic Polymer with a minium solid content to 40% solid mixed with cement in 1:1.5 proportion ( 1 part polymer and 1.5 part cement) on rebars after cleaning of rust scales with time interval of minimum 4 hours between each coat by brush as per manufacturers instruction.Anti-rust protective shall be procured from one of manufacturer given below. | 500 | Sqm | 70 ₹35,000 | 60 ₹30,000 | 150 ₹75,000 |
| 8.00 | M & L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete all complete as directed by Engr-in-Charge. | 500 | Sqm | 100 ₹50,000 | 60 ₹30,000 | 140 ₹70,000 |
| 9.00 | M&L for repairing the damaged concrete portion by SBR Polymer with a minimum solid content to 40% cement mortar in proportion 1:5:15 i.e. (1 part SBR polymer : 5 parts OPC cement and and 15 parts of graded quartz aggregate (sand) upto 25mm to 40 mm thickness as directed by the manufacturer's instruction including necessary curing etc. complete all as specified & as directed.SBR polymer shall be procured from one of manufacturer given below. | 500 | Sqm | 100 ₹50,000 | 70 ₹35,000 | 247 ₹1.2 L |
| 10.00 | M & L for water proofing treatment of external walls by applying two coats of elastomeric external acrylic water proofing coating material over a coat of primer after sealing all cracks with acrylic sealing compound as per the manufacturer’s specifications and directions . complete all as specified & as directed by EIC. (Note :- work will be carried out with scaffolding all over bldg upto G+6 floor of wall. Rate of scaffolding & elastomeric acrylic based exterior paint is included in this item). | 600 | Sqm | 60 ₹36,000 | 70 ₹42,000 | 77 ₹46,200 |
Updated dates
Tender Value
₹10.0 L
EMD Value
₹19,960
Closing Date
5 Mar 2026, 6:00 pmClosed
Assistant Garrison Engineer I Asvini
AGE(I) ASVINI, RC Church , Colaba ,Mumbai -400005
REPAIRS TO COLUMN BEAM SLAB AND CERTAIN STRUCTURAL REHABILITATION WORK INSIDE HOSPITAL BUILDING UNDER AGE I ASVINI
2025_MES_743017_3
8537/E8
Open Tender
Civil Works
270 days
AGE(I) ASVINI, RC Church, Colaba
Class E and above and Category a(i)
7 documents required · 7 mandatory
₹500
Assistant Garrison Engineer I Asvini
₹19,960
31 Mar 2026
5 Feb 2026
7 Mar 2026
5 Feb 2026
5 Mar 2026
19 Feb 2026
5 Feb 2026 - 26 Feb 2026
Chipping ,removing carefully concrete work by low impact hammer ,breaker without damaging the structure & cleaning and disposal of debris out side the premises etc. complete as directed by Engr-in-Charge. Hard concrete should not be removed by force.
Taking down cement plaster, any description on brick or stone surfaces, etc including racking out joints hacking for key scrubbing down with water etc and removal of debris outside MD land.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of any description in CM (1:4)with Ready mix plaster mixed with liquid water proofing compound and finished even & smooth without using extra cement completed all as specified. (Note : WPC will be measured and paid separately)
Supply only liquid water proofing compound of approved make
M & L for clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete, Applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem of Roff rust cleaner of Pidilite or Dr Fixit Rust removal or sholirust of STP Ltd. on the rebars,including cleaning the reinforcement ,wire brushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry.
M & L for providing and fixing additional steel bar or stirrups of diameter in variuos structural elements like columns,beams and foundations including drilling,bending and fixing the bars with epoxy putty etc. complete as directed by Engr-in-Charge.
M & L for applying two coats of anticorrosive Treatment to Reinforcement by application of two coats of anti-rust protective coating in the form of Acrylic Polymer with a minium solid content to 40% solid mixed with cement in 1:1.5 proportion ( 1 part polymer and 1.5 part cement) on rebars after cleaning of rust scales with time interval of minimum 4 hours between each coat by brush as per manufacturers instruction.Anti-rust protective shall be procured from one of manufacturer given below.
M & L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete all complete as directed by Engr-in-Charge.
M&L for repairing the damaged concrete portion by SBR Polymer with a minimum solid content to 40% cement mortar in proportion 1:5:15 i.e. (1 part SBR polymer : 5 parts OPC cement and and 15 parts of graded quartz aggregate (sand) upto 25mm to 40 mm thickness as directed by the manufacturer's instruction including necessary curing etc. complete all as specified & as directed.SBR polymer shall be procured from one of manufacturer given below.
M & L for water proofing treatment of external walls by applying two coats of elastomeric external acrylic water proofing coating material over a coat of primer after sealing all cracks with acrylic sealing compound as per the manufacturer’s specifications and directions . complete all as specified & as directed by EIC. (Note :- work will be carried out with scaffolding all over bldg upto G+6 floor of wall. Rate of scaffolding & elastomeric acrylic based exterior paint is included in this item).
Material and labour for preparation of newly plastered or previously untreated surfaces of walls and applying two coats of acrylic (100 % antifungal interior grade) paint over a coat of primer etc.complete all as specified and directed.
Material and labour for preparation of newly plastered or previously untreated surfaces of ceiling and applying two coats of acrylic (100 % antifungal interior grade) paint over a coat of primer etc.complete all as specified and directed.
M&L for injecting cement slurry grout in the ratio 1:2 (1-Cement 2-water) including super plasticizer (Supercom-100) 250 ml/50 Kgs. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled. The damaged area of the slab is to be repaired using polymer plaster (POLYMER MODIFIED MORTAR) (1:5:15) 1 monobond 5 Cement-15 sand) –in damaged areas . nozzle to be fixed to the slab using epoxy grout.The work includes complete sealing of cracks, voids from both floor and ceilng (For repair to slab)
Dismantling glass mosaic tiles from the wall surfaces including adhesive and rubbish off the MD premises
M & L for glass mosaic tiles 20 to 25 x 20 to 25 mm of thickness 3.8 to 4.3 mm of joint 1.6 mm assembled in panels of 300 x 300 mm to rendered surfaces adhesive. The backing paper shall be removed after the tiles have set by washing and cleaning the tiles and gently filling the joints completely (by applying 100 % tile area )using epoxy grout( somany ezy grout or eqvt) and remove excess grout gently from the surface of the tile and cleaning the surface including replacing the damaged/missing chips .
Note: The work has to be carried out in G+6 storey building in both accessible and in accessible areas. Necessary arrangements for scaffolding and conveyance shall be arranged by the contractor
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tenderdocument.pdf
Tender Documents • 0.91 MB
BOQ_841540.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid