Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAdmitted-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹25.4 L | L1 | Admitted-Finance |
| 2 | L2₹25.9 L+₹46,530 (1.83%)Admitted-Finance | ₹25.9 L+₹46,530 (1.83%) | L2 | Admitted-Finance |
| 3 | L3₹26.3 L+₹82,647 (3.25%)Admitted-Finance | ₹26.3 L+₹82,647 (3.25%) | L3 | Admitted-Finance |
| 4 | L4₹29.1 L+₹3.7 L (14.4%)Admitted-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | ₹29.1 L+₹3.7 L (14.4%) | L4 | Admitted-Finance |
| 5 | L5₹33.8 L+₹8.3 L (32.8%)Admitted-Finance | ₹33.8 L+₹8.3 L (32.8%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Varindera And Varindera Construction L5 | Rajesh Agencies L2 | R B TRADERS L4 | MAMTA ENTERPRISES L1 | Ayushmat Contractors L3 |
|---|---|---|---|---|---|---|---|---|
| .01Schedule 'A' Section - I | ||||||||
| 1.00 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed. | 50 | Cubic Metre | 450 ₹22,500 | 150 ₹7,500 | 150 ₹7,500 | 120 ₹6,000 Lowest | 150 ₹7,500 |
| 2.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick. | 47 | Cubic Metre | 100 ₹4,700 | 150 ₹7,050 | 20 ₹940 | 10 ₹470 Lowest | 30 ₹1,410 |
| 3.00 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. | 3 | Cubic Metre | 700 ₹2,100 | 400 ₹1,200 | 20 ₹60 | 10 ₹30 Lowest | 50 ₹150 |
| 4.00 | Material and labour for taking out old unserviceable and supply, laying, fixing Double walled corrugated HDPE duct pipe of 50mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. | 850 | Running Metre | 90 ₹76,500 | 70 ₹59,500 | 60 ₹51,000 | 95 ₹80,750 | 5 ₹4,250 Lowest |
| 5.00 | Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismantling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit. | 800 | Running Metre | 15 ₹12,000 | 5 ₹4,000 Lowest | 5 ₹4,000 Lowest | 10 ₹8,000 | 5 ₹4,000 Lowest |
| 6.00 | Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6.0 Sqmm 2 core with required aluminium cable lugs all as specified and directed. | 250 | Running Metre | 110 ₹27,500 | 110 ₹27,500 | 170 ₹42,500 | 58 ₹14,500 Lowest | 88 ₹22,000 |
| 7.00 | All as per item No. 6.00 here-in-before but 10 Sqmm 2 core complete all as specified and directed. | 250 | Running Metre | 135 ₹33,750 | 130 ₹32,500 | 200 ₹50,000 | 75 ₹18,750 Lowest | 110 ₹27,500 |
| 8.00 | All as per item No. 6.00 here-in-before but 16 Sqmm 3.5 core complete all as specified and directed. | 300 | Running Metre | 250 ₹75,000 | 215 ₹64,500 | 250 ₹75,000 | 135 ₹40,500 Lowest | 168 ₹50,400 |
| 9.00 | Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and light grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete ass as specified and testing on completion complete all as specified and directed Note - The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. | 10 | Each Set | 7,500 ₹75,000 | 5,000 ₹50,000 | 3,000 ₹30,000 Lowest | 3,200 ₹32,000 | 5,000 ₹50,000 |
Tender Value
₹36.6 L
EMD Value
₹73,240
Closing Date
4 Aug 2026, 6:00 pmClosed
Lt Col Jeethu Vijayan, Garrison Engineer, CEA
GARRISON ENGINEER KASAULI, DISTT SOLAN (HP) PIN 173204 PH 01792273107
REPAIR/ REPLACEMENT OF SOLAR WATER HEATERS, SOLAR PANEL, DG SET, SECURITY LIGHT, LIGHTENING CONDUCTOR, STREET LIGHTS, JUNCTION BOX, STREET LIGHT TIMER AND REPAIR/ RENEWAL OF AIR CONDITIONER, REFRIGERATON, DEEP FREEZERS CONNECTED WORKS AT KASAULI
2026_MES_777178_1
GEK-16/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KASAULI AND DAGSHAI UNDER GE KASAULI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE KASAULI
₹73,240
Yes
12 Sept 2026
8 Jul 2026
7 Aug 2026
8 Jul 2026
4 Aug 2026
23 Jul 2026
9 Jul 2026 - 14 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.01 | Schedule 'A' Section - I | - | - | - | - |
| 1 | Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed. | 50 | Cubic Metre | - | - |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick. | 47 | Cubic Metre | - | - |
| 3 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. | 3 | Cubic Metre | - | - |
| 4 | Material and labour for taking out old unserviceable and supply, laying, fixing Double walled corrugated HDPE duct pipe of 50mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. | 850 | Running Metre | - | - |
| 5 | Dismantling taking out carefully old/unserviceable UG cable any type any size from trenches/poles/ducts/LT panels after dismantling ends from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit. | 800 | Running Metre | - | - |
| 6 | Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 6.0 Sqmm 2 core with required aluminium cable lugs all as specified and directed. | 250 | Running Metre | - | - |
| 7 | All as per item No. 6.00 here-in-before but 10 Sqmm 2 core complete all as specified and directed. | 250 | Running Metre | - | - |
| 8 | All as per item No. 6.00 here-in-before but 16 Sqmm 3.5 core complete all as specified and directed. | 300 | Running Metre | - | - |
| 9 | Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and light grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete ass as specified and testing on completion complete all as specified and directed Note - The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. | 10 | Each Set | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_870395.xls
BOQ • 0.42 MB
GEK162627.pdf
Tender Documents • 0.90 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .