Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.9 L+₹56,450 (3.68%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-AOC L2 | |
| 3 | L3₹16.1 L+₹76,070 (4.95%)Rejected-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L3 | Rejected-AOC L3 | |
| 4 | L4₹16.3 L+₹93,850 (6.11%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹16.8 L+₹1.4 L (9.14%)Rejected-AOC HEAD OFFICE 20 2 626 B9 FIRST FLOOR TIRUMALA BYPASS ROAD TIRUPATI 517501 ANDHRA PRADESH | TIRUPATI | TIRUPATI | ANDHRA PRADESH | 517501 | L5 | Rejected-AOC L5 |
Tender Value
₹22.1 L
EMD Value
₹44,160
Closing Date
9 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIR/REPLACEMENT OF VARIOUS HANGAR LIGHTS AT AIR FORCE STATION YELAHANKA
2021_MES_474685_1
8921/E8
Open Tender
Civil Works
Item Rate
180 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹44,160
Yes
29 Dec 2021
13 Sept 2021
11 Oct 2021
13 Sept 2021
9 Oct 2021
27 Sept 2021
60 days
Amount
M&L for sub-main wiring with two runs of 1.5 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including conduit not less than 20mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 1.5 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and as directed. Note: 2 runs of cable and one run of earth wire and conduit will be measured as one length.
All same as per item No 1 here-in-before but size 2.5 Sqmm.
Supply and fix in repair LED street light fitting 45 Watts 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Eng-in-Charge.
Supply and fix in repair LED street light fitting 60 Watts 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Eng-in-Charge.
Supply and fix in repair LED street light fitting 72 Watts 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as directed by Eng-in-Charge.
Supply and fix in repair LED street light fitting 90 Watts 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as directed by Eng-in-Charge.
Supply and fix in repair LED flood light 150 watts, 230 V AC outdoor type with thermal management in multiple optics, powder coated pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts including testing commissioning and fixing upto 20 Mtr hight of hanger including necessary fixing arrangement of clamps nut bolts etc complete all as directed by Eng-in-Charge.
Supply and fix in repair LED flood light 200 watts, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lampCCT 5700K, lumen efficacy not less than 110 lumen/watts including testing commissioning and fixing upto 20 Mtr hight of hanger including necessary fixing arrangement of clamps nut bolts etc complete all as directed by Eng-in-Charge.
Supply and fixing industrial LED High Bay light fitting power range of 200 Watts, powder coated PDC aluminium body & PC optical lenses, Lumen efficiency of >110lm/W, 5700K CCT, Alluminum Die cast housing, IP66 with life of 50,000hrs with Eye bolt provided for mounting purpose for fixing on wall/ceiling mount available as accessory, flexible options to meet industrial lighting needs i.e. suspended/fixed to Hanger Ceiling, cool white light colour, material made out of die cast aluminum & extruded aluminum heat sink and finish powder coated complete connecting electrically including testing commissioning and fixing upto 20 Mtr hight of hanger including necessary fixing arrangement of clamps nut bolts etc complete all as directed by Engineer-in-charge.
S&F in repair LED light fittings 20 Watt,220 V,4 feet long, AC decorative box type with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-charge.
S&F in repair LED light fittings 10 Watt,220 V,2 feet long, AC decorative box type with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-charge.
Supply and fix driver suitable for 70/100 Watt LED flood light fittings and testing complete including taking down the Same all as specified and directed.
Supply and fix driver suitable for 120/150 Watt LED flood light fittings and testing complete including taking down the Same all as specified and directed.
Supply and fix driver suitable for 200/250 Watt LED lood light fittings and testing complete including taking down the Same all as specified and directed.
Supply and fix surge protector suitable for LED fixtures upto rated power of 70/100 watt and testing complete all as specified and as specified.
Supply and fix surge protector suitable for LED fixtures upto rated power of 120/150 watt and testing complete all as specified and as specified.
Supply and fix surge protector suitable for LED fixtures upto rated power of 200/250 watt and testing complete all as specified and as specified.
Supply and fix LED Aviation light luminaries Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complerte all as specified and as directed. Make - Bajaj Cat Part No. 110731 BGAV 302 LED or its techno equivalent.
Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Eng-in-Charge.
Supply and fixing round shape 18 watt 220 volts AC recessed/surface mounted type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) of 40 to 100 Amps rating triple pole and neutral in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge.
Supply and fixing in repair 230V 10KA 'B' curve miniature circuit breaker (MCB) of 32 Amps rating single pole and neutral in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge.
Supply and fixing in repair 230V 10KA 'B' curve miniature circuit breaker (MCB) of 6 to 32 Amps rating single pole in the DB complete with connection testing and commissioning all as specified and directed by Engr-in-charge.
Note : (a) Highbay light/Flood light/Street light/recessed, surface mounted light and submain wiring to be repaired/replaced upto 20 Mtr Height. (b) The expenditure on Ladder/Crane will be borne by the contractor and all rates deemed to be inluded for the same. (c) The bidder shall noted that one electrician and one helper be made available alongwith T&P at MES complaint cell for minimum two days in a week throughout the contract period against the fixing of items covered in BOQ. (d)The contractor has to quote his rates considering the above notes(a),(b) & (c) and nothing extra shall be paid by the department.
devan enterprises
S S BUILDERS
Varsha Enterprises
SRI LAKSHMI CONSTRUCTIONS
RRK PROJECTS
chowdeshwariconstructionco
RAINBOW ELECTRICALS
eurekaenterprises
JyothsnaNursery
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .