| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹6.5 LAdmitted-Finance | -11.11% | ₹6.5 L | L1 | Admitted-Finance |
| 2 | L2₹6.6 L+₹9,016.53 (1.39%)Admitted-Finance MAIN ROAD BONGAIGAON BONGAIGAON BONGAIGAON ASSAM 783380 | BONGAIGAON | ASSAM | 783380 | -9.87% | ₹6.6 L+₹9,016.53 (1.39%) | L2 | Admitted-Finance |
| 3 | L3₹8.9 L+₹2.4 L (37.1%)Admitted-Finance | +21.88% | ₹8.9 L+₹2.4 L (37.1%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical Clsass of Registraction and Digital electric Licence Not Enclosed |
Tender Value
₹7.3 L
EMD Value
₹14,540
Closing Date
24 Apr 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
EE PWD Electric Dn Bikaner
Various work related to the Construction of the building of Choudhary Bhimsen Government College, Lunkarsansar (AC Work)
2026_CEPWD_551679_4
E NIT 02/2026-27 EE PWD Electric Dn Bikaner
Open Tender
Electrical Works
Percentage
300 days
Lunkarsansar
Please refer tender document
2 documents required · 2 mandatory
₹500
Through Online E-Grass Challan BKN Office ID 4934
₹14,540
Yes
EE PWD Electric Dn Bikaner
12 Jul 2026
14 Apr 2026
27 Apr 2026
14 Apr 2026
24 Apr 2026
14 Apr 2026
14 Apr 2026 - 24 Apr 2026
20 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply , Installation, Testing and Commissioning of Inverter type Air cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity up to 42 Degree Celsius ambient temperature. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 degree C (out door ambient temperature) | - | - | - | - |
| 2 | Cooling capacity 6200-6350 Watt, ISEER not less then 3.8 | - | Each | - | - |
| 3 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and testing procedure as per IS:10810. | - | - | - | - |
| 4 | 2 core x 2.5 Sq.mm | - | mtr | - | - |
| 5 | Supply, installation, testing and commissioning of interconnecting copper refrigerant piping of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. duly insulated with tubular elastomeric nitrile rubber FM/UL approved with high water vapor diffusion resistance and low thermal conductivity should be certified 'Class O' in Fire Propagation as per BS 476 Part 6 with 7 mil Glass Cloth and 3 coats of anti UV paint (on area which is exposed to weather) including chase cutting andfilling with mortar, Slotted channel supports mounted on 10 mm threaded rod at suitable spacing the exposed piping shall be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as required of following sizes. | - | - | - | - |
| 6 | 15.9 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | - | mtr | - | - |
| 7 | 6.4 mm O.D., wall thinkness ≥ 0.8mm (insulation – 13 mm thick) | - | mtr | - | - |
| 8 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. | - | - | - | - |
| 9 | 25 mm | - | mtr | - | - |
| 10 | Supply, Fixing and testing of following capacity IS:8448 marked wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. | - | - | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
Newtermandconditiion.pdf
Tender Documents • 4.68 MB
BOQ_983242.xls
BOQ • 0.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .