Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC 433 USTAD AMIR KHAN SARANI HARIDEVPUR KOLKATA 700082 | KOLKATA | KOLKATA | WEST BENGAL | 700082 | L1 | Accepted-AOC Lowest Rate | |
| 2 | L2₹4.4 L+₹1,665 (0.38%)Rejected-Finance 21 KBM CHAKDAH P O P S CHAKDAH DIST NADIA PIN 741222 | CHAKDAH | NADIA | WEST BENGAL | 741222 | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹4.4 L+₹2,800 (0.63%)Rejected-Finance RASULPUR BUS STAND CONTAI | CONTAI | WEST BENGAL | L3 | Rejected-Finance Higher than L1 |
Tender Value
Refer Docs
EMD Value
₹9,090
Closing Date
25 Nov 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer
Raghunathpur, Jhargram.
WBPHE/EE/JMD/NIeT 18_4 OF 2022-2023
2022_PHED_421415_4
WBPHE/EE/JMD/NIeT 18 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
30 days
Jhargram
Please refer Tender documents.
4 documents required · 4 mandatory
₹9,090
Yes
9 Dec 2022
16 Nov 2022
28 Nov 2022
16 Nov 2022
25 Nov 2022
17 Nov 2022
Amount
Dismantling of existing damaged internal wiring, voltage stabilizer etc. part by part by hiring electrician as per direction of E.I.C.
Supply & delivery of following materials at site:- 20 KVA, 3 phase oil cooling type servo motor operated Voltage Stabilizer, having unbalance 200 - 500 V input voltage, and 415(±1%) output voltage , Auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with MCB at output side, input MCCB, Ammeter Bell etc. as per I.E rules and as per instruction of EIC. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
100 mm dia, (PN-1.0) CIDF, wafer type butterfly Valve operated by three phase actuator conforming to BS: 5155 or IS 13095/1991. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
1.1 KV Grade 415 V, 4 core 16 sq.mm. PVC sheathed XLPE insulated Al. armoured cable conforming to IS:7098 (PART-1) 1988 with latest amendmends as applicable. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.(Cable shall be procured as per site requirement.)
1.1 KV Grade 415 V, 12 core 1.5 sq.mm. Copper control cable, Solid Copper Conductor & Balance Stranded copper, XLPE insulated PVC Inner sheated, Armoured extruded PVC Type ST2 Sheeted as per IS:7098 (PART-1) 1988 with latest amendmends as applicable. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.(Cable shall be procured as per site requirement.)
100 Amp, 4 pole on load change over switch. Make: havells(category code. IHBFFE0063)/ any other approved make.
100 Amps, 415 V, 4 pole ICTPN (Iron Claded Triple Pole Neutral) main switch in sheet steel enclosure having rewireable type fuse grip. (Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019)
100 Amps, 415 V Bus-Bar chamber having 4 nos. Aluminium Bus-Bar. (Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019)
6-32 Amp,10 kA, 240/415V, 50 Hz SP MCB conforming to IS / IEC: 60898-1, "C" characteristics. (6 Amp- 2 nos., 10 Amp-1 no., 16 Amp-1 no.) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
6 way SP&N Double Door horizontal Distribution Board (I/C 2 + O/C 4) conforming to IS 13032 & IS 8623 and IP42/43. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
LED street light luminarie IP 66 LM6-HPDC Housing Street light aerodynamically designed with better thermal management/ Potted driver is to be provided,the luminaire and housing should be from the same manufacturer(cat no- BRP052 LED CW 045 MR FG S1 PSU GR, LUMEN O/P-4500, System Efficacy greater than 100 lumen/watt) Make-Philips OR Equivalent and same techinal specification of Havells.The manufacturer has to provide LM79/LM80 reports corresponding to the luminaire/LED Chip along with type test Certificate.Respectively the luminaire manufacturer should have an in house NABL Accredited testing facility.
PVC moulded chair without arm. (Make:- Nilkamal/Supreme/Cello)
PVC moulded table of 850 x 850x 725 mm size. (Make:- Nilkamal/Supreme/Cello)
100 Amp, 240/415 V Porcelain fuse unit (Base & Bridge) Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
Hard wooden board (450mm X 304.8 mmx 2 mm thick)
Installation of the above items :- Making brick built foundation with supplying of all required materials suitable for the above Voltage stabilizer by (4:1) cement mortar including holding down foundation bolts(If required) and plaster with neat cement finish as per direction of E.I.C.
Installation of the above voltage stabilizer (as on item no. 2) on the foundation including all connection complete as per direction of E.I.C.
Fitting, Fixing and connection of above supplied changeover switch and main switch (as in item no. 6,7) on the wall by supplying all necessary materials to complete the job.
Fitting-fixing of the supplied wooden board (as in item no. 15) at suitable position on wall with fitting-fixing of supplied 100 Amp Porcelain fuse units (as in item no. 14) on the board by supplying and fitting-fixing of required nos. of nuts-bolts-washers etc. all complete as per direction of E.I.C
Fitting fixing of the existing Butterfly valve with Actuator (as on item no. 3) by supplying of rubber gaskets and nut bolts, washers etc. all complete per direction of E.I.C
Fitting-fixing of the distribution board (as in item no. 10) on flat /angle iron frame at desired position on wall of pump house with supplying & fitting-fixing of required nos. of nuts, bolts, washers etc. with necessary earthing arrangement from nearest earth grid by G.I. wire/ strip all complete as per direction E.I.C. This includes the cost of fitting-fixing of the Isolator & MCBs within the DB including necessary power connections by 2.5 mm2 FRLSH copper wire (Havells /KEI/Finolex/Gloster/polycab/other approved make) all complete as per direction of E.I.C.
Laying of cable (as in item no. 4) on wall/surface incl. S & F of MS saddles with earthing attachment in 10 SWG GI (Hot Dip) wire, making holes etc. as necy. mending good damages and painting all complete as per direction of E.I.C.
Laying of cable (as in item no. 5 on wall/surface incl. S & F of MS saddles with earthing attachment in 10 SWG GI (Hot Dip) wire, making holes etc. as necy. mending good damages and painting all complete as per direction of E.I.C.
Laying of cable (as in item no. 5) in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of cable (as in item no. 4) all complete as per direction of E.I.C.
Finishing the end of cable (as in item no. 4) by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials all complete as per direction of E.I.C.
Making internal wiring/electrification of the Pump house by (2x 22/0.3 (1.5 sqmm) + 1x 22/0.3 (1.5 sqmm) single core PVC insulated multistrand FRLSH Grade flexible copper wire through 20 mm PVC conduit pipe/casing by supplying one no. 40 Amp, 10kA, 240/415V,50 Hz SPN/DP MCB Isolator conforming to IS / IEC: 60947-3, "C" characteristics. (As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019) with required module PVC Board & piano key type switch. (ave. run 6 mtr). i) LED Tube set point-2 nos., Bulk Head light point- 1 no., 5 pin 6 Amps. Plug point- 1 no., 16 Amp socket,switch, indicator- 1 no. each, with necy. earthing arrangement & one fan point (Total point 6 nos. points) including drawing power by suitable gauge (2.5 mm2) of copper wire from installed cut-out to SPN/DP MCB within DB through 20 mm PVC casing capping (precision make) as per direction of EIC (fittings should be of Philips make & wiring should be with continuous earthing arrangement and 20W two nos. 4 ft long LED tube light sets PHILIPS Astra Line, one no. bulk head (Endura WT202W LED6S NW PSU S2 PC), one no. 0-4 step fan regulator (Humfree), fittings etc to be supplied by agency).
S&F of 3" dia 1.5 mt minipole with baseplate to be fixed on rooftop incl. S&F of 1.5 mtr long arm bracket (removable type) incl. CC muffing (450X450X600) with neat cement finish & painting incl.S&F 200x150x100 mm 16 SWG CI loop box including neccessery power connection by 3X22/.03 (1.5 Sqmm) (2 nos. Phase and Neutral and 1 no ECC) FRLS-H pvc insulated & unsheated copper wire (approved make) in 20 mm size PVC rigid conduit FRLS-H (precision Make) including necy. fittings as required as per direction of EIC. (for 12m length @ 102/mtr.) as directed by EIC.
Connecting the equipments body to earth busbar including S&F 20 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Supply, delivery and fitting-fixing of 230 volt 1200 mm sweep AC ceiling fan with ball bearing complete with all accessories such as blade, canopy, fork, down rod etc. Make :- As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019.
Carrying back the damaged materials from worksite to Jhargram Mechanical Division site store including loading unloading at both ends as per direction of E.I.C
Add: 18% GST
Add: 1% CESS
DAS CONSTRUCTION
PRANAB KUMAR DAS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .