Loading…
Loading…
Tender Value
₹21.9 L
EMD Value
₹43,800
Closing Date
29 May 2026, 5:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER ELG
12 conditions · 4 needing a document upload
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Scanned copy of valid Trade license or Propitorship Certificate.
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
Electrical (General) work in connection with "Extension FOB at MLV Station in the Jurisdiction of SSE/W/BHP under AEN/BHP".
EL-HWH-25-21-3552-A
EL-HWH-25-21-3552-A
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹43,800
29 May 2026
6 May 2026
15 May 2026
103 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 21,87,117 | ||
| — | — | — | 52,000 | ||
| Drawing of cable on wall / structure with suitable size and shape GI clamps including supply of suitable size GI Clamp and GI nut- bolts and commissioning of cable ( Cable will be supplied by Railway ) | — | 1300.00 | — | — | |
| — | — | — | 3,27,600 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting with laying of cable through suitable dia HDPE pipe including supply of pipe (PE-100 grade, PN-10 or higher) and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable. ( Cable will be supplied by Railway ) | — | 1400.00 | — | — | |
| — | — | — | 1,09,440 | ||
| Trenching and laying of cable under ground by soil cutting through suitable dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) | — | 720.00 | — | — | |
| — | — | — | 10,200 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 120.00 | — | — | |
| — | — | — | 42,180 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 60.00 | — | — | |
| — | — | — | 23,750 | ||
| Trenching, laying under road / track through 100 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commi- ssioning of cable including back filling of trench with excavated soil after laying of cable ( Cable will be supplied by Railway ) | — | 50.00 | — | — | |
| — | — | — | 12,975 | ||
| Drawing of cable through one no. 2" dia, 3.0 Mtrs. long GI pipe ( Make - Tata / Jindal / Bansal ) for protection of cable on pole with proper GI clamps and GI nuts & bolts including supply of GI pipe ( Cable will be supplied by Railway ) | — | 15.00 | — | — | |
| — | — | — | 60,886 | ||
| Supply of heavy gauge GI fabricated Cable tray with GI supporting structure and GI nut-bolts and washer of suitable sizes as per site requirement including fixing and commissioning. | — | 1.00 | — | — | |
| — | — | — | 5,374 | ||
| Supply of Straight Through jointing kits ( Heat shrinkable ) suitable for XLPE / PVC insulated stranded Aluminium conductor cable of size 4 / 3.5 x 50-95 sq.mm., 1100V grade complete with all accessories including jointing, testing and commissioning. ( Make - m-seal / Raychem / Mahindra / Densons / 3M / Polycab ) | — | 2.00 | — | — | |
| — | — | — | 19,000 | ||
| Releasing of old, unused LT cables of various sizes | — | 500.00 | — | — | |
| — | — | — | 38,008 | ||
| Supply, fixing, connection, testing and commissioning of MCCB with Microprocessor Release of breaking capacity 36 kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory 7) All Microprocessor protection-based MCCB / ACB must have facility of individual 'LSIG' fault indication, suitable for Release Range 40-100A, 4 Pole including metal enclosure with internal wiring. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 2.00 | — | — | |
| — | — | — | 2,44,867 | ||
| Supply of LT 6 Way VTPN / SMDB Wall Mounted Double Door Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder comprising with the following items :- a) MCCB, 4 Pole, ( 63 - 160 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt Ground Fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memorry, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication - 1 no. b) MCCB, 4 Pole, ( 25 - 63 )Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ) Microprocessor based release with above mentioned features in (a) - 4 nos. c) RCBO, 2 Pole, 10 Amp, 240V, 50Hz, 10kA, Sensitivities - 300 mA - 4 nos. d) Tinned Copper Busbar (4 Bar) each of capacity 200 Amps., 415V, 50 Hz - 1 set e) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 5 nos. f) CT of suitable ratio for MFM - 15 nos. g) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF & TRIP" indication for all incoming and outgoing feeders - 26 nos. h) Petty Store for control cable, MCBs, gland, socket, fuse, push button, spreader terminals, auxiliary contacts, shunt release, terminal blocks etc. - 1 job. i) Fabrication work for above panel - 1 job. complete with all other accessories, internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with cable glanding, socketing etc. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Energy Meter - Secure / LK (L&T) / Genus / Conzerv / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 1.00 | — | — | |
| — | — | — | 12,243 | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 1.00 | — | — | |
| — | — | — | 33,680 | ||
| Supply of Outdoor pillar box type control panel board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following : a) MCCB with Thermal - Magnetic Release of breaking capacity 36 kA at 415V AC, 50Hz ( Ics = 100% Icu ) suitable for release range 25-32A, 4 Pole - 1 no. b) Astronomical Timer Switch - 2 nos. c) Power Contactor, 3 Pole, 18A, 415V, 50 Hz - 2 nos. d) LED indication lamp for 3-Phases for incoming feeders and "ON, OFF, TRIP " indication for all incoming and outgoing feeders - 10 nos. complete with fabrication, internal wiring by single core copper conductor cable and all other accessories for above panel ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 2.00 | — | — | |
| — | — | — | 1,678 | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories | — | 2.00 | — | — | |
| — | — | — | 63,592 | ||
| Supply of TPN MCB DB ( Heavy duty, Outdoor type, UV ray protected, self fire- extinguishing and resistant to abnormal heat and fire up to 650 degree C GWT, shock resistance IK08 or above and IP65 degree of protection grade transparent DB box, similar to ABB Mistral65 - 20 Modules or equivalent ), 3Ph, 50Hz, 415V, 4 way per phase, 415V, 50Hz, complete with total 12 nos. SP MCB of current rating from 6A to 32A, 10 kA, 240 Volt, 50Hz per phase as per requirement of load and one no. FP RCBO 63A, 300mA, 10 kA, 415V, 50Hz, Suitable for AC + Pulsating DC (Type A) + Harmonics ( Make of MCB & RCBO - LK (L&T) / Siemens / ABB / Hager Legrand / Schneider ) ( Make of TPN DB - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / Spelsberg / Hensel / Eaton ) | — | 4.00 | — | — | |
| — | — | — | 548 | ||
| Fixing, connection, testing and commissioning of above TPN MCB DB including all incoming and outgoing cables glanding, cable connection with cable termination and suitable wall hanging arrangement as per site condition with all associated accessories. | — | 4.00 | — | — | |
| — | — | — | 57,606 | ||
| Supply of SPN DB ( Metal Enclosure with Metal Door ), 14 way, 50Hz, complete with 10 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per requirement of load and 1 no. DP RCBO of current rating 63A, 300mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) | — | 6.00 | — | — | |
| — | — | — | 726 | ||
| Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 6.00 | — | — | |
| — | — | — | 17,480 | ||
| Supply of Sheet Moulded Compound ( SMC ) JB box, fire retardant of size 700 x 480 x 210 mm ( IP-55 ) / equivalent size heavy duty, outdoor type, UV ray protected, self fire- extinguishing, shock resistance IK08 or above and IP65 degree of protection grade transparent polycarbonate DB box including fitment with suitable size and shape Mild Steel ( MS ) bracket by replacing existing damage box and accessories with testing and commissioning. ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) | — | 4.00 | — | — | |
| — | — | — | 11,580 | ||
| Supply of Sheet Moulded Compound ( SMC ) JB box, fire retardant of size 450 x 375 x 200 mm ( IP-55 ) / equivalent size heavy duty, outdoor type, UV ray protected, self fire- extinguishing, shock resistance IK08 or above and IP65 degree of protection grade transparent polycarbonate DB box including fitment with suitable size and shape Mild Steel ( MS ) bracket by replacing existing damage box and accessories with testing and commissioning. ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) | — | 4.00 | — | — | |
| — | — | — | 9,800 | ||
| Supply of Sheet Moulded Compound ( SMC ) JB box, fire retardant of size 250 x 250 x 155 mm ( IP-55 ) / equivalent size heavy duty, outdoor type, UV ray protected, self fire- extinguishing, shock resistance IK08 or above and IP65 degree of protection grade transparent polycarbonate DB box including fitment with suitable size and shape Mild Steel ( MS ) bracket by replacing existing damage box and accessories with testing and commissioning. ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) | — | 4.00 | — | — | |
| — | — | — | 7,244 | ||
| Supply of MCB DB complete with 1 no. FP MCB 32A, 415V, 50 Hz, 10kA or as per requirement of load with polycarbonate distribution box enclosure (IP-65) with polycarbonate transparent openable window including fixing, connection, testing and commissioning. ( Make of MCB - L&T/Siemens/ABB/Hager/Legrand/Schneider and Enclosure Board - Grasp/OBO Bettermann/ABB/Schneider ) | — | 4.00 | — | — | |
| — | — | — | 364 | ||
| Fixing, connection and commissioning of above MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 4.00 | — | — | |
| — | — | — | 5,260 | ||
| Supply of MCB DP, 40A, 1Ph, 240V, 50 Hz, 10kA with polycar- bonate distribution box enclosure (IP-65) with polycarbonate trans- parent openable window including fixing, connection, testing and commissioning. ( Make of MCB - L&T/Siemens/ABB/Hager/Legrand/Schneider and Enclosure Board - Grasp/OBO Bettermann/ABB/Schneider ) | — | 4.00 | — | — | |
| — | — | — | 7,008 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 24.00 | — | — | |
| — | — | — | 1,630 | ||
| Wiring of 6A / 3 pin Plug board consisting with one plug socket and one 6A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 10.00 | — | — | |
| — | — | — | 1,540 | ||
| Wiring of 6/16A 3 pin Plug board consisting with one 16/6A 3 pin plug socket and one 16A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 4.00 | — | — | |
| — | — | — | 2,272 | ||
| Wiring of Multi Plug board consisting with three nos. 6A / 3 pin plug socket, three nos. 6A switch, one no. 6/16A 3 pin plug socket, one no. 16A switch, one no. 10A fuse kit-kat / MCB and one indicator ( Red ) by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4 sq. mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 4.00 | — | — | |
| — | — | — | 27,200 | ||
| Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 400.00 | — | — | |
| — | — | — | 24,800 | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 6.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 200.00 | — | — | |
| — | — | — | 23,200 | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 100.00 | — | — | |
| — | — | — | 1,05,000 | ||
| Wiring of Mainline by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for 03 phases and 01 neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 140.00 | — | — | |
| — | — | — | 24,800 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 200.00 | — | — | |
| — | — | — | 58,000 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 400.00 | — | — | |
| — | — | — | 15,300 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for three phases and one neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 100.00 | — | — | |
| — | — | — | 4,440 | ||
| Fixing, connection, testing and commissioning of indoor LED luminaire fittings with suitable arrangement. ( LED indoor light fitting will be supplied by Railway ) | — | 60.00 | — | — | |
| — | — | — | 64,100 | ||
| Supply of Indoor LED Trunking light system consisting with extruded aluminium housing ( for 1200 mm length ) with associated accessories and 40 Watt trunk mounted LED luminaire ( Type of LED - Surface Mounting Device ) with industrial grade constant current driver ( Efficiency - Greater than 90% ) with short circuit protection, aluminium housing and milky polycarbonate diffuser ( Make / brand of LED chip - NICHIA, OSRAM, SEOUL, PHILIPS, LUMILEDS, EVERLIGHT, AVAGO, CREE, LEDNIUM, APT Electronics & BRIDGELUX ), LED luminaire system Efficacy - Greater than 130 Lumens per Watt, Ingress Protection - IP54 or higher, SDCM<5, CRI>80 with Colour Temperature - 5700K to 6500K (Cool white), Driver Operating Voltage - 140-270 Volt AC, Surge Protection minimum 4KV, THD< 10%, Power factor >0.95, Driver HV Cut off @ 325V/440V (P2P) protection for 8 hrs., Life span of LED chip Greater than 50000 hours, The Luminaire and Driver both should be off same make/brand and individually BIS approved with 60 months warranty and all other accessories suitable for surface / suspended mounting as per site condition. ( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies ) | — | 20.00 | — | — | |
| — | — | — | 1,140 | ||
| Fixing, connection, testing and commissioning of above luminaire fittings with suitable arrangement and necessary cables etc. | — | 20.00 | — | — | |
| — | — | — | 936 | ||
| Fixing, connection and commissioning of Street Light luminaire with suitable dia heavy gauge GI bend pipe with GI clamps made of GI flat of size 40mm x 6mm and GI nut-bolts on structure / wall ( LED Street light fitting will be supplied by Railway ) | — | 4.00 | — | — | |
| — | — | — | 6,086 | ||
| Fixing, connection and commissioning of out door LED Flood light / Street Light fitting on High Mast Tower / Pole / Structure with suitable arrangement. ( LED outdoor light fitting will be supplied by Railway ) | — | 34.00 | — | — | |
| — | — | — | 1,06,240 | ||
| Supply of Thermoplastic Polycarbonate Busbar Chamber of dimen- sion 450mm x 300mm x 210mm consisting with 4 nos. tinned copper busbar of each bar of capacity 200 Amp, 6 way, suitable for 415V, 50Hz supply system and 6 nos. Cable glands with Ingress protection : IP65 or higher as per IEC-60529 ( weather proof), rust, dust, moisture and shock proof, anti corrosive, halogen free acid resistant, light weight, impact resistant IK 08/09 as per IEC- 60068-2-72, fire returdant, insulated, UV stabilised as per EN ISO 4892, should withstand glow wire test at 960 degree C as per IS 11000-2-1,IEC-60695-2-10 and fire rated UL94V-0 complete with hinged door with locking arrangement including fixing, connection and commissioning of above Junction Box on pole/structure with mounting clamp. ( Make : Hensel / Sintex / OBO Bettermann / RMC / Grasp / ABB / Legrand / Spelsberg / EPP Composites ) | — | 8.00 | — | — | |
| — | — | — | 1,03,590 | ||
| Supply of GI ( minimum coating thickness 65 microns ) conical / octagonal ( minimum sheet thickness - 3mm ) Pole of overall length 5 M with single / double arm bracket, top cover, base plate including hinged door-inbuilt Junction box complete with copper bar, insulator, Hylam sheet for cable termination and fuse kit-kat / MCB ( Make - Utkarsh / B.P. Projects / Crompton / Bajaj / Surya ) | — | 15.00 | — | — | |
| — | — | — | 46,740 | ||
| RCC foundation, erection and commissioning of above GI pole with construction of cement concrete muffing ( Cement : Stone : Sand = 1 : 2 : 4 ) with foundation accessories including earthing of pole with 1 no. of 50 mm dia, 3 M long GI pipe ( Make - TATA / Jindal / Bansal ) with necessary earth connection from pipe to pole by GI Strip / GI wire | — | 15.00 | — | — | |
| — | — | — | 6,156 | ||
| Construction of concrete ( Cement : Stone : Sand = 1 : 2 : 4 ) muffing on pole of size 450 mm x 450 mm x 600 mm. | — | 18.00 | — | — | |
| — | — | — | 10,512 | ||
| Supply of Junction Box made of GI sheet, complete with hinged door and lock incorporated with 4 nos. porcelain insulator, copper bar, hylam sheet for cable termination and fuse kit-kat / MCB of capacity 16A, 240V alongwith fixing on pole by suitable size and shape GI clamp / GI nut-bolt and commissioning of Junction Box. | — | 18.00 | — | — | |
| — | — | — | 11,814 | ||
| Wiring of light point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral through pole from inbuilt pole Junction Box's porcelain fuse kit-kat / MCB to light fitting along with 1 no. single core HRFR / FRLS grade, PVC insulated copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 66.00 | — | — | |
| — | — | — | 672 | ||
| Dismantling / Cutting of existing pole and make good of surface including transportation from site to stores | — | 2.00 | — | — | |
| — | — | — | 22,284 | ||
| Earthing of pole with 1 no. of 50 mm dia, 3.0 Mtrs. long GI pipe ( Make - Tata / Jindal / Bansal ) with necessary earth connection from pipe to pole by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) | — | 18.00 | — | — | |
| — | — | — | 9,948 | ||
| Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) | — | 4.00 | — | — | |
| — | — | — | 3,33,628 | ||
| Goods & Services Tax ( at present @ 18% ) | — | 1.00 | Lumpsum 333628.00 | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
HTLTstandardspecification.pdf
ATTACHMENT
Advancecorrectionslips.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf Tender form and annexure
ATTACHMENT
TenderBooklet.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
3552-AClause.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .