Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹42.6 L+₹1.8 L (4.41%)Rejected-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-AOC L2 Bidder | |
| 3 | L3₹49.0 L+₹8.2 L (20.2%)Rejected-AOC | L3 | Rejected-AOC L3 Bidder | |
| 4 | L4₹54.0 L+₹13.2 L (32.3%)Rejected-AOC | L4 | Rejected-AOC L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
3 Jan 2022, 6:00 pmClosed
GE AF Amla
GE AF Amla, Betul Dist 460553 (MP)
Provision of exhaust fans, geyser and wash basin with connected works in Airmen SMQs/ Special repairs of earthing infrastructure and lightening protection system at certain sheds/ Provision of certain revenue and minor works at AFS Amla
2021_MES_492781_1
8464/E8 of 2021-202
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE AF Amla
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹98,000
Yes
25 Feb 2022
6 Dec 2021
10 Jan 2022
6 Dec 2021
3 Jan 2022
20 Dec 2021
Amount
B/R Portion S&F Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe all as specified and directed. (16)
M&L for 32mm dia; Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed including dismantling old unserviceable one complete all as specified and directed. (16)
S&F 32mm dia waste pipe of polyethylene of low or high density or PVC. 32 mm dia, suitable for vitreous china wash hand basin complete all as specified and directed. (16)
S&F 15mm dia Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete including taking down old rusted tap complete all as specified and directed. (16)
Taking up or down 15mm dia bore steel tubing alongwith its connections from any position such as wall, floor, ceiling etc., including cleaning for refixing complete all as specified and directed. (24)
S&F 40mm bore; High density polyethylene pipes (HDPE) of pressure rating 6 kgf/Sq.cm fixed complete to walls, ceilings or in floors etc., all as specified and directed. (16)
S&F Brass chromium plated bottle traps of 32 mm bore for wash basins/ urinals with inlet and outlet screwed for pipe or connections including necessary packing, union and cap all as specified and directed. (16)
Taking down cement plaster on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc. all as directed. (12)
M&L for digital coloured glazed ceramic tiles in vertical surfaces 350 x 250 x 7mm/450 x 350 x 7 mm thick, etc set and jointed in neat cement slurry and pointed in colour cement to match the shade of tiles including 10mm thick backing coat in 1:4 cement mortar complete all as specified and directed. (12)
E/M Portion Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for taking out pole / cables/ earthing and earth lead etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. (158.6)
All as per item No 11 here in before but depth exceeding 1.5m and not exceeding 3 metres and getting out in soft/ loose soil complete all as specified and directed. (1.73)
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/ loose soil complete all as specified and directed. (139.3)
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. (21.03)
Material & Labour for plain cement concrete 1:3:6, Type C2 using 40 mm graded stone aggregate as in foundations of pole etc complete all as specified as directed. (5.7)
Material & Labour for plain cement concrete 1:2:4, Type B1 using 20 mm graded stone aggregate as in coping of poles and mass concrete including all necessary formwork complete all as specified & as directed. (0.62)
Dismantling old unserviceable steel poles, any size from site including necessary demolition of concrete as in coping and foundation of poles and making good the disturbed surface complete all as specified and directed. (8)
Supply & install of steel tubular swaged poles complete with cast iron base plate 6mm thick of size 450mm x 450mm finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) pole made out of ERW MS tubing confirming to IS 2713 / IS 1161 Part II including drilling of holes of required size and nos for fixing of cross arms bracing support/ taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete after taking down old one complete all as specified and as directed. Note: Excavation of earthwork, PCC concrete bed etc will be measured & paid in respective item of works (8)
S&F in repair cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium silver paint including dismantling and removal of old rusted cross arms complete all as specified and as directed. (0.65)
S&F in repairs junction box IP 65 with plain walls of size 167mm x 125mm x 82mm made up of Polystyrene having shutter and lifting knob with provision of earth strip entry glands fixed to walls or pole with nuts, bolts, washers and testing complete all as specified and directed. (150 ) Make: - Hensel cat No K-8100 or equivalent in Neptune/Syntex
M&L for cutting and screwing existing 15mm dia bore steel tubing for alterations or additions (or lengthening screw on the pipe to form connector) in position without taking down complete all as specified and directed. (78)
S&F Stainless steel flexible connection pipe 15mm size with brass nuts of length 450 mm, as a hot water outlet for geyser complete all as specified and directed. (78)
S&F 15 mm bore; Bib taps, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specified and directed. (78)
2 runs of 4 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor (390)
2 runs of 6 Sqmm size main cable and one run of 6 Sqmm size earth continuity conductor (6)
S&F Single pole and neutral enclosure with a two-pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 V complete all as specified and directed. (78)
M&L for point wiring using approved colour coding as per IS with 1.5 sq. mm two single core PVC insulated but unsheathed FRLS cable, 1100 volts grade, ISI-694 marked with multistranded copper conductor and earth continuity wire with similar 1.5 Sqmm cable (including connecting to earth dolly) drawn through ISI Marked heavy-duty rigid PVC concealed conduit with all accessories etc with mild steel sunken box 50mm deep duly, concealed in the wall and having PVC modular cover plate with a frame suitable for modular switch/ Sockets/ regulators for One Exhaust fan/ Fan point controlled by one switch one way. (78 + 33 + 27 )
All as per item No : 26 but for point wiring with 2.5 Sqmm two single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board (45)
S&F Modular switch 01 way 6 Amp , 01 module complete all as specified. (78 + 33 + 27)
S&F Modular switch 01 way 16 Amp , 01 module complete all as specified (45)
S&F Modular socket, 6 Amp/ 16 Amp - 2/3 pin combined, two in one, 02 module complete all as specified. (45)
S&F Modular step fan step regulator, 120 Watt - 02 module complete all as specified. (10)
S&F Ceiling rose of 3 phase/ PVC/ polycarbonate, isolated body all as specified and directed. (78 + 33 + 27)
S&F Water heater (Geyser) storage type (Vertical type) of capacity 25 Ltrs, energy saver/energy-efficient 5-Star rating, 230V, 2KW element, single-phase AC supply, the inner tank made out of heavy-duty stainless steel sheet glass line coated, having pressure release valve, non-return valve and drain valve, thermostat with auto cut off etc, hanging on the wall with 4 Nos of steel fasteners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, including electric, earthing and water connection to geyser and testing on load (Filled with water) upto entire satisfaction of Engineer-in-Charge/JE complete all as specified and directed by Engineer-in-Charge. Note:- (i) Srl Number of geyser and 'GE AF Amla' shall also be writing on geyser with red colour permanent marker, which will be issued by Engineer-in-Charge and cost for the same shall be deemed to be included in the quoted unit rate, nothing shall be paid extra on this account. (ii) Geyser installed/ hanging at various locations as directed by Engineer-in-charge within the Jurisdiction of GE AF Amla (from market to AGE E/M store/AGE E/M store to sites /Location), all conditions will be the responsibility of the contractor and nothing extra will be admissible on this account. (78)
Taking down ceiling fan carefully from any height of any size/ sweep, any make fixed/ hanged at different locations, dismantling the fan complete cleaning and re-assembling the same including replacing Anti suicide down rods, split pins, replacing the damaged rubber reel, nuts & bolts with washers, providing flexible copper cable of size 1.5 Sq.mm twin core, 70 cm long and refixing in the same location/ position complete all as specified and directed. Note:- Anti suicide fan down rod will be measured and paid separately under appropriate items and cost of other minor items as mentioned above if any required at site will be replaced by the contractor at his own cost and quoted rate deemed to be inclusive this provision. (1925)
S&F 10 inch length Smart MS Anti suicide down rod manufactured by M/s GOLD LIFE (or) Anti suicide down rod with device including buzzer manufactured by M/s Safe halo’, having colour of white/ brown/ ivory for ceiling fan of any size and make complete all as specified and directed. (1725) Note: - (i) if the load on fan exceed 22 Kg, the device/rod shall released and spring shall be expands and test certificate for it to be produce at the time of execution all as specified.
S&F 12 inch length Smart MS Anti suicide down rod manufactured by M/s GOLD LIFE (or) Anti suicide down rod with device including buzzer manufactured by M/s Safe halo’, having colour of white/ brown/ ivory for ceiling fan of any size and make complete all as specified and directed (200) Note: - (i) if the load on fan exceed 22 Kg, the device/rod shall released and spring shall be expands and test certificate for it to be produce at the time of execution all as specified.
S&F Ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including providing flexible copper cable from the ceiling rose to the connector of fan and writing MES number on fan complete all as specified and directed. (10)
M&L for making of wall opening/hole in the existing brick/ RCC wall for fixing exhaust fan of size 300mm dia including cutting of steel reinforcement, making good disturbed surface using cement mortar 1:4 to match with existing surface and paint to match with existing shade complete all as specified and directed. (78 + 22)
M&L for making of wall opening/hole in the existing brick/ RCC wall for fixing exhaust fan of size 450mm dia including cutting of steel reinforcement, making good disturbed surface using cement mortar 1:4 to match with existing surface and paint to match with existing shade complete all as specified and directed. (5)
S&F Exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, frame and louvers, max 410 Watts, minimum 1400 RPM including providing flexible copper cable 1.5 sq.mm from the ceiling rose to the connector of fan complete all as directed. (78 + 22)
S&F Exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, frame and louvers, max 410 Watts, minimum 1400 RPM including providing flexible copper cable 1.5 sq.mm from the ceiling rose to the connector of fan complete all as directed. (5)
S&F Wall mounted fan made of sturdy Engineering plastic complete, AC single Phase. 230V of size 400mm sweep with, blades and protective cage frame, minimum 1400 RPM including necessary installation at site complete all as specified and directed. (21)
S&F LED Flood light fitting of 80W, including lamp, with PF > 0.95, class IP 65 and above Housing of pressure die cast aluminum alloy and heat sink extruded aluminum complete all as specified and directed. Note: LED flood light supplied by the bidder should conform to relevant IS/ BIS standard specification. (2)
Taking down old defective conductor strips of any type/description (i.e GI, Aluminium & copper strip) from wall/ roof and making good to the disturbed surfaces to match the existing surface complete all as specified & directed. (1735 )
Taking down old unserviceable roof earth continuity conductor/ static discharge strips of any type and description/ size from wall/roof/floor and refixing the same with insulator epoxy coated at 0.5 metre span including brass nut, bolts, washers etc. and making good to the disturbed surfaces to match the existing complete all as specified and directed at site. Note : - Insulators shall be measured and paid separately. (150 )
Dismantling stay assembly complete including necessary demolition of concrete, etc., and making good to the disturbed surfaces to match the existing surface all as specified and directed. Note:- Excavation work will be measured separately. (8)
M&L for plate earthing in replacement of old earthing complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of equipment’s/ earthing test point etc at the other end, earth strip encased in and including 40 mm GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25x4mm iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with wire mesh funnel and earth pit in PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate and CI cover and frame complete all specified and shown in electrical plate No 3 of SSR Part-1 including testing earth resistance and submitting test report to AGE E/M by the contractor complete all as specified and directed. Note :- (i) Rates for excavation and earthwork in any kind of soil/ strata, testing on completion, GI strip 32x6 mm and 40 mm dia light grade GI protection pipe upto 7.5 metres from earth plate is deemed to be included in the rate quoted. (ii) On testing after completion if less than 5 Ohm earth resistance is not obtained the earthling will be redone by the contractor at no extra cost the department. (26)
M&L for plate earthing in replacement of old earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl copper earth strip 20x3 mm bolted (with copper/ brass nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of equipment’s/ earthing test point etc at the other end, earth strip encased in and including 40 mm GI light grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25x4mm iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with wire mesh funnel and earth pit in PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate and CI cover and frame complete all specified and shown in electrical plate No 3 of SSR Part-1 including testing earth resistance and submitting test report to AGE E/M by the contractor complete all as specified and directed. (6) Note:- (i) Rates for excavation and earthwork in any kind of soil/ strata, testing on completion, copper strip 20x3 mm and 40 mm dia light grade GI protection pipe upto 7.5 metres from earth plate is deemed to be included in the rate quoted. (ii) On testing after completion if less than 5 Ohm earth resistance is not obtained the earthling will be redone by the contractor at no extra cost to the department.
S&F in repairs earthing funnel made out of aluminium/GI sheet in conical shape for watering the earth pit (Note: Dia of mouth of funnel shall not be less than 5 cm) complete all as specified and directed. (131)
S&F in repairs light grade GI pipe 40 mm dia for protection of earthing lead including fixing to wall, steel frame, floor etc., complete all as specified and directed. ( 72 )
Supply and laying in repair 32 mm bore class 3 grade PVC pipe for protection of earth strip completein trenches / fixed to walls/ fixed to poles with suitable clamps at 0.5 meter apart spancomplete all as specified and directed. NOTE :- Rates for flat iron clamps, bolts, nuts and washer etc are deemed to be included in rate quoted. (320 )
M&L in replacement for "Test Point Terminal Block" made of gun metal or phosphorus bronze of having size 75 X 75 X 25 mm drilled and screwed by providing 3 Nos 8 mm dia 25 mm long hex. head screw and connected to Copper/ Aluminium / GI strips complete housed in a PVC junction box after taking down old one complete all as specified and directed. Note:- (i) The test points will be properly fixed on epoxy insulators. (ii) Epoxy insulators & PVC junction box will be paid and measured separately under relevant items. (60)
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) earth pit chamber having outer dimension of size 54cm x 54cm x 54cm of wall with floor thickness of 150mm thick; laid over 75 mm thick, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) foundation including necessary form work, earth work to earth pit, demolishing old brick Masonry/ PCC chamber and supply and laying of prefabricated RCC earth pit cover of size 60cm x 60cm X 50mm made using RCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) and 8mm dia Fe-500 grade TMT reinforcement bars @ 140mm center to center on both ways, including two nos 8mm dia TMT bar handles embedded into pit cover complete all as specified and directed. ( 82 )
S&F in repair Copper strip of size 100 X 50 X 5 mm drilled and screwed including 3 nos 8 mm dia screw and washers connected to Copper/ Aluminium/ GI strips after taking down old one complete all as specified and directed. ( 37 )
S&F in repair Air termination single pointed aluminium rod not less than 12mm dia and 300mm long end threaded all as specified and as directed. (100)
S&F in repair Air termination single pointed copper rod not less than 12mm dia and 300mm long end threaded including taking down old one complete all as specified and directed. (50)
S&F in repair Post insulator epoxy LV type suitable for copper/aluminium/ GI strip 25 x 4 mm lightening conductor fixed on wall/roof/pole including screw including taking down old one complete all as specified and directed. (600 )
S&F in repairs porcelain, vitreous, white, brown or green insulator shackle type 50mm height, 65mm dia with 9mm dia bolts washers and nuts including galvanised and mild steel straps, including taking down old one complete all as specified and directed. Note: The rate quoted by the bidder will deemed to include dismantling of existing roof conductor from shackle insulator and re-fixing. ( 8 )
S&F stay assembly for angle iron / pole of lightening conductor comprising of 7/3.15 mm galvanised mild steel stranded stay wire of required length fixed to angle iron / pole with and including flat iron clamp of 50 x 6mm size, bolts nuts, washers stay rod of 16mm dia, 2.15 metres long, stay bow, with nuts bolts, washers, galvanised steel plate 230 x 230 x 6mm and 2 No thimble, including necessary PCC 1:3:6 type C2 (40 mm graded stone aggregate) for foundation complete all as specified and as directed. Note:- Rates for excavation/ returning filling/ removal etc. is deemed to be included in unit rate quoted by the contractor. (8)
S&F in repairs Aluminium strip of size 25 x 4 mm fixed to wall/ pole with aluminium saddles and screws for roof/ down conductor above ground/ buried in ground/ drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed. Note:- Insulators/conduit/pipe shall be measured and paid separately under respective items. ( 925 )
S&F Copper strip of size 20 x 3 mm fixed to wall with aluminium saddles and screws drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed. Note:- Insulators/conduit shall be measured and paid separately under respective items. ( 210 )
S&F Galvanised iron strip of size 25x4 mm fixed to wall with Galvanised iron saddles and screws / buried in ground/ drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed. Note:- Insulators/conduit/pipe shall be measured and paid separately under respective items. ( 600 )
Dismantling of old existing unserviceable manual type fire damper from AC duct in AHU room of AC plant of Shed No. 22 complete all as specified and directed. ( 1 )
Supply and installation of Automatic fire damper of size 51.18 inch x 23.63 inch x 5.51 inch, at least 90 minutes fire rating as per specification and approved shop drawing complete with the fusible link with spring return mechanism and limit switch to shut off AHU blowers when the temperature of fusible link reacts 74-degree celsius rated all as specified and directed. ( 1 )
B/R & E/M Portion S&F 15mm dia bore; steel water tubing ISI marked, medium grade galvanised, with all fittings such as bends, elbows tees, short, pieces, connections, back nuts, diminishing pieces caps, plugs and unions etc, fixed to walls, ceiling, floor etc., with clamp complete all as specified and directed. (414)
S&F PVC connection pipe of 15mm size with PTMT nuts of length 450mm for connecting cold water inlet of geyser/ pipes/ valves complete all as specified and directed. (94 )
S&F 15mm dia; Stop valves, fancy type, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. (94 )
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Shri Sai Enterprises
Vee kay construction
M/s SHIVRATAN CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .