Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC | ₹2.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.6 Cr+₹94.9 L (35.3%)Rejected-Finance | ₹3.6 Cr+₹94.9 L (35.3%) | L2 | Rejected-Finance L2 |
| 3 | L3₹3.7 Cr+₹98.9 L (36.8%)Rejected-Finance JHARIA BENIGANJ HARDOI | BENIGANJ | HARDOI | UTTAR PRADESH | ₹3.7 Cr+₹98.9 L (36.8%) | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical bidder is not qualified for next evaluation |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
29 Mar 2023, 2:00 pmClosed
SUPERINTENDING ENGINEER
ELECTRICITY DISTRIBUTION CIRCLE MAHARAJGANJ
Strengthening of Electricity System And Construction of New 11 KV Independent Line For Nagar Panchayat Paniyara, Brijmanganj and Strengthening of Electricity System for Anand Nagar Tehsil Under EDD-II Anand nagar Under Deposit scheme Year 2022-23
2023_PVVNV_788711_1
26/EDC(M)/2022-23
Open Tender
Electrical Works
Turn-key
90 days
ANANDNAGAR
Tender documents
2 documents required · 2 mandatory
₹5,900
Superintending Engineer Electricity distri circle
₹2.7 L
10 Aug 2023
23 Mar 2023
30 Mar 2023
23 Mar 2023
29 Mar 2023
23 Mar 2023
Amount
PART-A (i) 11 KV Independent Feeder for new nagar Panchayat Paniyara Supply of following materials-
PCC pole (8.5 Mtr long) as per specification.
ST Pole (11 Mtr long) as per specification.
ACSR Weasel Conductor as per specification.
ACSR Dog Conductor as per specification.
ABC Cable (3x120+1x95+1x16 sq mm) as per specification.
11 KV Pin insulator with pin with bolt as per specification.
11 KV Disc Insulator with disc fitting as per specification.
11 KV V-type X-arm as per specification.
MS Top Channel as per specification.
MS T-off Channel as per specification.
MS Droper angle as per specification.
MS Gaurding Angle as per specification.
GI Stay complete as per specification.
MS Earthing complete 20X2500 mm as per specification.
11 KV MS X-arm holding clamp as per specification.
MS Top channel & Dropper clamp with nut bolt as per specification.
MS Tee-off channel clamp with nut & bolt as per specification.
MS F bracket with nut & Bolt as per specification.
MS Gaurding Angle Clamp with nut bolt as per specification.
6 SWG GI Wire as per specification.
L.T. PVC Cable 3.5x70 Sq mm. as per specification.
LT Cable (3.50x150) as per specification.
LT Cable (3.50x240) as per specification.
LT. Clamp with nut & bolts as per specification.
LT. shackle insulator 100x115 mm. as per specification.
Bolt & nut washer for shackle insulator as per specification.
Dead-end Clamp as per specification.
MS Suspension Clamp as per specification.
GI Piercing Clamp as per specification.
LT Distribution Box as per specification.
I- Hook as per specification.
MS Angle 75x75x6x2028 mm (T/F Base) as per specification.
11 KV XLPE Cable (3x185 mm2) as per specification.
11 KV jointing kit O/D (3x185mm2) as per specification.
11 KV jointing kit I/D (3x185mm2) as per specification.
T/F 250 KVA as per specification.
T/F 100 KVA as per specification.
T/F 63 KVA as per specification.
T/F 25 KVA as per specification.
11KV VCB For O/G (CTR 200/100/5A 350 MVA) TOSHIBA MAKE
GI Pipe of 150 mm Dia 2mm thick, 3 mtr long
PG Clamp For Dog to Dog Conductor.
Barbed Wire.
SMC Danger Board of size 200mmx250mmx3mm thick as pe specification of drawing.
PART-A (i) Construction of 11 KV Independent Feeder for new nagar Panchayat Paniyara
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. 1) 8.5 Mtr Single PCC Pole.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. 1) 8.5 Mtr Double PCC Pole.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. 1) 11Mtr Long STP, SP-55 Round Pole
Grouting of supports in CC 1:4:8 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per drawing. Work includes back filling and proper ramming. 1) 8.5 Mtr PCC Pole
Grouting of supports in CC 1:4:8 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per drawing. Work includes back filling and proper ramming. 1) 11Mtr Long STP, SP-55 Round Pole
Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 33KV and Stay Clamps.
Installation of 11 KV X-arm on Poles with Cross Arm Holding Clamp as per specification.
Installation of Top Channel /T-off channel with clamp with nut and bolts.
Installation of Dropper angle/ Guarding angle with clamp Nut And Bolts.
Laying, spreading, lifting and final sagging of 3 phases of ACSR Dog conductor in accordance with profile and sag chart including binding, Jumpering and fixing of P.G. Clamp as per requirement in 03 Nos. conductor in parallel.
Laying, spreading, lifting and final sagging of 3 phases of ACSR Weasel conductor in accordance with profile and sag chart including binding, Jumphering and fixing of P.G. Clamp as per requirement in 03 Nos. conductor in parallel.
Guarding between two poles like single poles, double poles, four poles, etc. to guard L.T., 11KV Line telephone line and river crossing, road crossing etc. with G.I. wire No.6SWG and G.I. wire No.8SWG, including cutting with fabrication and fixing of guarding cross arm with clamps, nut & bolts etc, as per drawing.
Chopping of branches of trees of eucalyptus, Neem, Banyan and other kind of trees along the route of the line and disposal of the same at suitable place.
Installation of GI Pipe of 150 mm Dia 2mm thick, 3 mtr long with Clamps Nut and Bolts.
Wrapping of barbed wire on 8.5 Mtr. PCC/ 11 Mtr. ST SP-55 Poles as anti-climbing device for a length of 0.9Mtr. Wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a height of 2.75Mtr. from the ground, complete with providing and fixing of lower end & upper end clamps made of M.S. Flat 40x5mm complete with nuts & bolts.
Digging of Cable Trench of size 1050mmx750mm, for laying of 11KV, 3x185 Sq.mm. Cable, along the Road.
Safe laying of 11KV, 3x185 Sq.mm. XLPE Cable in Cable Trench to respective Double Pole.
Providing and Laying of Ist Class Bricks, along the length on both side of 11KV XLPE Cable in Cable Trench (minimum 27No. Bricks/Mtr per Cable) and Stone Slab of size 450x600x50mm on top of the each Cable, including providing & filling River Sand inside the Bricks.
Back filling of excavated earth in the cable trench upto the ground level and ramming properly.
Earthing of 8.5 Mtr PCC Pole with M.S. earth Rod of (20x2500)mm long including excavation of pit and driving M.S.Rod 3.0M apart from suppor and 0.5M below the ground level and connecting belowl the earth electrodes with the help of G.I.wire No. 6 SWG and earthing lugs.
Earthing of 11 Mtr ST Poles with M.S. earth Rod of (20x2500)mm long including excavation of pit and driving M.S .Rod 3.0M apart from suppor and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. wire No. 6 SWG and earthing lugs.
Laying of LT PVC Cable 3.5x70 sqmm with required Al. Lugs
Laying of LT Cable 3.5x150 sqmm
Laying, spreading, lifting and final sagging of ABC Cable in accordance with profile and sag chart including binding, Jumpering and fixing of P.G. Clamp as per requirement.
Construction of 250 KVA Transformer Plinth of size 2.0x2.0x1.5m as per specification.
Providing & fixing of SMC Danger board at each location as per specification of the drawing. Size 200mmx250mm & 3mm thickness with G.I Clamp & nut & bolt.
Laying of LT Cable of size 3.5x240 sqmm
Installation of LT distribution box on PCC Pole with Clamp, Nut and Bolt.
Making of Cable end termination by 11 KV 3x185 sqmm XLPE O/D Cable Jointing Kit.
Making of Cable end termination by 11 KV 3x185 sqmm XLPE I/D Cable Jointing Kit.
Installation of M.S. Angle of size 75x75x6x2028 mm for T/F base with clamp, Nut and Bolts
Installation of distribution Transformer on Double Pole structure with H.T and LT side connection and Transformer Body & Neutral Earthing by 50x6 mm size M.S Flat a) 100 KVA
Installation of 250 KVA distribution Transformer on Plinth with H.T and LT side connection and Transformer Body & Neutral Earthing by 50x6 mm size M.S Flat.
Installation, Testing, commissioning and earthing of 11 KV outgoing VCB Panel of CTR-200/100/5A, 350 MVA
PART-B(i) Supply of Material for 11 KV Independent Feeder for new nagar Panchayat Brijmanganj
PCC pole (8.5 Mtr long) as per specification.
ST Pole (11 Mtr long) as per specification.
ACSR Weasel Conductor as per specification.
ACSR Dog Conductor as per specification.
ABC Cable (3x120+1x95+1x16 sq mm) as per specification.
11 KV Pin insulator with pin with bolt as per specification.
11 KV Disc Insulator with disc fitting as per specification.
11 KV V-type X-arm as per specification.
MS Top Channel as per specification.
MS T-off Channel as per specification.
MS Droper angle as per specification.
MS Gaurding Angle as per specification.
GI Stay complete as per specification.
MS Earthing complete 20X2500 mm as per specification.
11 KV MS X-arm holding clamp as per specification.
MS Top channel & Dropper clamp with nut bolt as per specification.
MS Tee-off channel clamp with nut & bolt as per specification.
MS F bracket with nut & Bolt as per specification.
MS Gaurding Angle Clamp with nut bolt as per specification.
6 SWG GI Wire as per specification.
L.T. PVC Cable 3.5x70 Sq mm. as per specification.
LT Cable (3.50x150) as per specification.
LT Cable (3.50x240) as per specification.
LT. Clamp with nut & bolts as per specification.
LT. shackle insulator 100x115 mm. as per specification.
Bolt & nut washer for shackle insulator as per specification.
Dead-end Clamp as per specification.
MS Suspension Clamp as per specification.
GI Piercing Clamp as per specification.
LT Distribution Box as per specification.
I- Hook as per specification.
MS Angle 75x75x6x2028 mm (T/F Base) as per specification.
11 KV XLPE Cable (3x185 mm2) as per specification.
11 KV jointing kit O/D (3x185mm2) as per specification.
11 KV jointing kit I/D (3x185mm2) as per specification.
T/F 250 KVA as per specification.
T/F 100 KVA as per specification.
T/F 63 KVA as per specification.
T/F 25 KVA as per specification.
11KV VCB For O/G (CTR 200/100/5A 350 MVA) CG MAKE
GI Pipe of 150 mm Dia 2mm thick, 3 mtr long
PG Clamp For Dog to Dog Conductor.
Barbed Wire.
SMC Danger Board of size 200mmx250mmx3mm thick as pe specification of drawing.
HDPE Pipe PE-80, PN-6, DN-160mm dia Pipe for laying of 11KV, 3x185Sq.mm, XLPE Cable with HDD (trenchless) method.
PART-B(ii) Construction of 11 KV Independent Feeder for new nagar Panchayat Brijmanganj
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. 1) 8.5 Mtr Single PCC Pole.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. 1) 8.5 Mtr Double PCC Pole.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. 1) 11Mtr Long STP, SP-55 Round Pole
Grouting of supports in CC 1:4:8 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per drawing. Work includes back filling and proper ramming. 1) 8.5 Mtr PCC Pole
Grouting of supports in CC 1:4:8 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per drawing. Work includes back filling and proper ramming. 1) 11Mtr Long STP, SP-55 Round Pole
Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 33KV and Stay Clamps.
Installation of 11 KV X-arm on Poles with Cross Arm Holding Clamp as per specification.
Installation of Top Channel /T-off channel with clamp with nut and bolts.
Installation of Dropper angle/ Guarding angle with clamp Nut And Bolts.
Laying, spreading, lifting and final sagging of 3 phases of ACSR Dog conductor in accordance with profile and sag chart including binding, Jumpering and fixing of P.G. Clamp as per requirement in 03 Nos. conductor in parallel.
Laying, spreading, lifting and final sagging of 3 phases of ACSR Weasel conductor in accordance with profile and sag chart including binding, Jumphering and fixing of P.G. Clamp as per requirement in 03 Nos. conductor in parallel.
Guarding between two poles like single poles, double poles, four poles, etc. to guard L.T., 11KV Line telephone line and river crossing, road crossing etc. with G.I. wire No.6SWG and G.I. wire No.8SWG, including cutting with fabrication and fixing of guarding cross arm with clamps, nut & bolts etc, as per drawing.
Chopping of branches of trees of eucalyptus, Neem, Banyan and other kind of trees along the route of the line and disposal of the same at suitable place.
Installation of GI Pipe of 150 mm Dia 2mm thick, 3 mtr long with Clamps Nut and Bolts.
Wrapping of barbed wire on 8.5 Mtr. PCC/ 11 Mtr. ST SP-55 Poles as anti-climbing device for a length of 0.9Mtr. Wire pitch/ gap 13mm and fixing upper and lower end keeping lower end at a height of 2.75Mtr. from the ground, complete with providing and fixing of lower end & upper end clamps made of M.S. Flat 40x5mm complete with nuts & bolts.
Digging of Cable Trench of size 1050 mmx750 mm, for laying of 11KV, 3x185 Sq. mm. Cable, along the Road.
Safe laying of 11KV, 3x185 Sq.mm. XLPE Cable in Cable Trench to respective Double Pole.
Providing & Laying of 1st Class Bricks, along the length on both side of 11KV XLPE Cable in Cable Trench (minimum 27No. Bricks/Mtr per Cable) and Stone Slab of size 450x600x50mm on top of the each Cable, including providing & filling River Sand inside the Bricks.
Back filling of excavated earth in the cable trench upto the ground level and ramming properly.
Earthing of 8.5 Mtr PCC Pole with M.S. earth Rod of (20x2500)mm long including excavation of pit and driving M.S.Rod 3.0M apart from suppor and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I.wire No. 6 SWG and earthing lugs.
Earthing of 11 Mtr ST Poles with M.S. earth Rod of (20x2500)mm long including excavation of pit and driving M.S .Rod 3.0M apart from suppor and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. wire No. 6 SWG and earthing lugs.
Laying of LT PVC Cable 3.5x70 sqmm with required Al. Lugs
Laying of LT Cable 3.5x150 sqmm
Laying, spreading, lifting and final sagging of ABC Cable in accordance with profile and sag chart including binding, Jumpering and fixing of P.G. Clamp as per requirement.
Construction of 250 KVA Transformer Plinth of size 2.0x2.0x1.5m as per specification.
Providing & fixing of SMC Danger board at each location as per specification of the drawing. Size 200mmx250mm & 3mm thickness with G.I Clamp & nut & bolt.
Laying of LT Cable of size 3.5x240 sqmm
Installation of LT distribution box on PCC Pole with Clamp, Nut and Bolt.
Making of Cable end termination by 11 KV 3x185 sqmm XLPE O/D Cable Jointing Kit.
Making of Cable end termination by 11 KV 3x185 sqmm XLPE I/D Cable Jointing Kit.
Installation of M.S. Angle of size 75x75x6x2028 mm for T/F base with clamp, Nut and Bolts
Installation of distribution Transformer on Double Pole structure with H.T and LT side connection and Transformer Body & Neutral Earthing by 50x6 mm size M.S Flat a) 100 KVA
Installation of 250 KVA distribution Transformer on Plinth with H.T and LT side connection and Transformer Body & Neutral Earthing by 50x6 mm size M.S Flat.
Installation, Testing, commissioning and earthing of 11 KV outgoing VCB Panel of CTR-200/100/5A, 350 MVA
NOC of Railway Crossing from Railway Departement and Laying of HDPE Pipe PE-80, PN-6, DN-160mm dia Pipe for laying of 11KV, 3x185Sq.mm, XLPE Cable with HDD (trenchless) method.
Laying of 11KV, 3x185Sq.mm XLPE cable in laid HDPE Pipe PE-80, PN-6, DN-160mm dia by HDD trenchless method, as per site requirement.
PART-C(i) Supply of material for 11 KV Independent Feeder for nagar Panchayat (Extension), Anand nagar (Tehsil)
PCC pole (8.5 Mtr long) as per specification.
ST Pole (11 Mtr long) as per specification.
ACSR Weasel Conductor as per specification.
ACSR Dog Conductor as per specification.
ABC Cable (3x120+1x95+1x16 sq mm) as per specification.
11 KV Pin insulator with pin with bolt as per specification.
11 KV Disc Insulator with disc fitting as per specification.
11 KV V-type X-arm as per specification.
MS Top Channel as per specification.
MS T-off Channel as per specification.
MS Dropper angle as per specification.
MS Gaurding Angle as per specification.
GI Stay complete as per specification.
MS Earthing complete 20X2500 mm as per specification.
11 KV MS X-arm holding clamp as per specification.
MS Top channel & Dropper clamp with nut bolt as per specification.
MS Tee-off channel clamp with nut & bolt as per specification.
MS F bracket with nut & Bolt as per specification.
MS Gaurding Angle Clamp with nut bolt as per specification.
6 SWG GI Wire as per specification.
L.T. PVC Cable 3.5x70 Sq mm. as per specification.
LT Cable (3.50x150) as per specification.
LT Cable (3.50x240) as per specification.
LT. Clamp with nut & bolts as per specification.
LT. shackle insulator 100x115 mm. as per specification.
Bolt & nut washer for shackle insulator as per specification.
Dead-end Clamp as per specification.
MS Suspension Clamp as per specification.
GI Piercing Clamp as per specification.
LT Distribution Box as per specification.
I- Hook as per specification.
MS Angle 75x75x6x2028 mm (T/F Base) as per specification.
11 KV XLPE Cable (3x185 mm2) as per specification.
11 KV jointing kit O/D (3x185mm2) as per specification.
11 KV jointing kit I/D (3x185mm2) as per specification.
T/F 250 KVA as per specification.
T/F 100 KVA as per specification.
T/F 63 KVA as per specification.
T/F 25 KVA as per specification.
11KV VCB For O/G (CTR 200/100/5A 350 MVA) Stel MAKE
Chemical Earthing for VCB
GI Pipe of 150 mm Dia 2mm thick, 3 mtr long
PG Clamp For Dog to Dog Conductor.
Barbed Wire.
SMC Danger Board of size 200mmx250mmx3mm thick as pe specification of drawing.
HDPE Pipe PE-80, PN-6, DN-160mm dia Pipe for laying of 11KV, 3x185Sq.mm, XLPE Cable with HDD (trenchless) method.
PART-C(ii) Construction of 11 KV Independent Feeder for nagar Panchayat (Extension), Anand nagar (Tehsil)
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. 1) 8.5 Mtr Single PCC Pole.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. 1) 8.5 Mtr Double PCC Pole.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. 1) 11Mtr Long STP, SP-55 Round Pole
Grouting of supports in CC 1:4:8 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per drawing. Work includes back filling and proper ramming. 1) 8.5 Mtr PCC Pole
Grouting of supports in CC 1:4:8 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per drawing. Work includes back filling and proper ramming. 1) 11Mtr Long STP, SP-55 Round Pole.
Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 33KV and Stay Clamps.
Installation of 11 KV X-arm on Poles with Cross Arm Holding Clamp as per specification.
Installation of Top Channel /T-off channel with clamp with nut and bolts.
Installation of Dropper angle/ Guarding angle with clamp Nut And Bolts.
Laying, spreading, lifting and final sagging of 3 phases of ACSR Dog conductor in accordance with profile and sag chart including binding, Jumpering and fixing of P.G. Clamp as per requirement in 03 Nos. conductor in parallel.
Laying, spreading, lifting and final sagging of 3 phases of ACSR Weasel conductor in accordance with profile and sag chart including binding, Jumphering and fixing of P.G. Clamp as per requirement in 03 Nos. conductor in parallel.
Guarding between two poles like single poles, double poles, four poles, etc. to guard L.T., 11KV Line telephone line and river crossing, road crossing etc. with G.I. wire No.6SWG and G.I. wire No.8SWG, including cutting with fabrication and fixing of guarding cross arm with clamps, nut & bolts etc, as per drawing.
Chopping of branches of trees of eucalyptus, Neem, Banyan and other kind of trees along the route of the line and disposal of the same at suitable place.
Installation of GI Pipe of 150 mm Dia 2mm thick, 3 mtr long with Clamps Nut and Bolts.
Wrapping of barbed wire on 8.5 Mtr. PCC/ 11 Mtr. ST SP-55 Poles as anti-climbing device for a length of 0.9Mtr. Wire pitch/ gap 13mm and fixing upper and lower end keeping lower end at a height of 2.75Mtr. from the ground, complete with providing and fixing of lower end & upper end clamps made of M.S. Flat 40x5mm complete with nuts & bolts.
Digging of Cable Trench of size 1050 mmx750 mm, for laying of 11KV, 3x185 Sq. mm. Cable, along the Road.
Safe laying of 11KV, 3x185 Sq.mm. XLPE Cable in Cable Trench to respective Double Pole.
Providing & Laying of 1st Class Bricks, along the length on both side of 11KV XLPE Cable in Cable Trench (minimum 27No. Bricks/Mtr per Cable) and Stone Slab of size 450x600x50mm on top of the each Cable, including providing & filling River Sand inside the Bricks.
Back filling of excavated earth in the cable trench upto the ground level and ramming properly.
Earthing of 8.5 Mtr PCC Pole with M.S. earth Rod of (20x2500)mm long including excavation of pit and driving M.S.Rod 3.0M apart from suppor and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I.wire No. 6 SWG and earthing lugs.
Earthing of 11 Mtr ST Poles with M.S. earth Rod of (20x2500)mm long including excavation of pit and driving M.S .Rod 3.0M apart from suppor and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. wire No. 6 SWG and earthing lugs.
Laying of LT PVC Cable 3.5x70 sqmm with required Al. Lugs
Laying of LT Cable 3.5x150 sqmm
Laying, spreading, lifting and final sagging of ABC Cable in accordance with profile and sag chart including binding, Jumpering and fixing of P.G. Clamp as per requirement.
Construction of 250 KVA Transformer Plinth of size 2.0x2.0x1.5m as per specification.
Providing & fixing of SMC Danger board at each location as per specification of the drawing. Size 200mmx250mm & 3mm thickness with G.I Clamp & nut & bolt.
Laying of LT Cable of size 3.5x240 sqmm
Installation of LT distribution box on PCC Pole with Clamp, Nut and Bolt.
Making of Cable end termination by 11 KV 3x185 sqmm XLPE O/D Cable Jointing Kit.
Making of Cable end termination by 11 KV 3x185 sqmm XLPE I/D Cable Jointing Kit.
Installation of M.S. Angle of size 75x75x6x2028 mm for T/F base with clamp, Nut and Bolts
Installation of distribution Transformer on Double Pole structure with H.T and LT side connection and Transformer Body & Neutral Earthing by 50x6 mm size M.S Flat a) 100 KVA
Installation of 250 KVA distribution Transformer on Plinth with H.T and LT side connection and Transformer Body & Neutral Earthing by 50x6 mm size M.S Flat.
Installation, Testing, commissioning and earthing of 11 KV outgoing VCB Panel of CTR-200/100/5A, 350 MVA
NOC of Railway Crossing from Railway Departement and Laying of HDPE Pipe PE-80, PN-6, DN-160mm dia Pipe for laying of 11KV, 3x185 Sq.mm, XLPE Cable with HDD (trenchless) method.
Laying of 11KV, 3x185Sq.mm XLPE cable in laid HDPE Pipe PE-80, PN-6, DN-160mm dia by HDD trenchless method, as per site requirement.
ARK ENGINEERING
M/s Anil kumar singh
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .