Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.6 LAccepted-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | ₹47.6 L Quoted ₹47.9 L | L1 | Accepted-AOC AWARD OF CONTRACT |
| 2 | L2₹55.3 L+₹7.4 L (15.3%)Rejected-Finance 121004 | ₹55.3 L+₹7.4 L (15.3%) | L2 | Rejected-Finance BEING NOT LOWEST TENDER |
| 3 | L3₹57.8 L+₹9.9 L (20.6%)Rejected-Finance NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | ₹57.8 L+₹9.9 L (20.6%) | L3 | Rejected-Finance BEING NOT LOWEST TENDER |
| 4 | L4₹58.8 L+₹10.9 L (22.8%)Rejected-Finance | ₹58.8 L+₹10.9 L (22.8%) | L4 | Rejected-Finance BEING NOT LOWEST TENDER |
| 5 | L5₹62.7 L+₹14.8 L (31.0%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹62.7 L+₹14.8 L (31.0%) | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹99,800
Closing Date
20 Jul 2022, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
UPGRADATION OF EXISTING FACILITES AT DHOBI GHAT AND OTHER SANCTIONED WORKS AT DIFFERENT LOCATIONS IN DOMESTIC AND TECHNICAL AREA AT AFS SULUR
2022_MES_531353_1
8479/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹99,800
Yes
8 Aug 2022
16 Jun 2022
21 Jul 2022
16 Jun 2022
20 Jul 2022
30 Jun 2022
16 Jun 2022 - 27 Jun 2022
Amount
SCHEDULE A BOQ
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out any type of soil complete all as specified and as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying XLPE cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense of soil complete all as specified and as directed.
M&L Plain Cement Concrete 1:4:8 type D2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L Reinforced cement concrete (nominal mix ) 1:1 1/2 :3 type A-1 (using 20mm graded crushed stone aggregate) as in footing foundation including raft , footing, foundation beam, plinth beam,bases for columns and mass concrete etc complete all as specified and as directed.
M&L use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter , straight rough finished surfaces complete all as specified and as directed
M&L Reinforced cement concrete (nominal mix ) 1:1 1/2 :3 type A-1 (using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed
M&L use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished flat surfaces of concrete complete all as specified and as directed.
M&L Reinforced cement concrete (nominal mix ) 1:1 1/2 :3 type A-1 (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed
M&L use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work: not exceeding 200mm thick (Horizontal or sloping) rough finished flat surfaces of concrete complete all as specified and as directed.
M&L use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified and as directed.
M&L Reinforced cement concrete (nominal mix ) 1:1 1/2 :3 type A-1 (using 20mm graded crushed stone aggregate) as in columns, pillars, post and struts etc complete all as specified and as directed
M&L use and waste of formwork to sides of pillars, posts, struts, piers, columns straight rough finished surfaces complete all as specified and as directed.
M&L Reinforced cement concrete (nominal mix ) 1:1 1/2 :3 type A-1 (using 20mm graded crushed stone aggregate) as in chajjas complete all as specified and as directed
M&L use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges with rough finished flat surfaces of concrete complete all as specified and as directed.
S&F High strength corrosion resistant TMTsteel bar of grade Fe-500, 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
M&L High strength corrosion resistant TMTsteel bar of grade Fe-500 , 5 mm dia to 10 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips in stirrups , spacers and binders etc complete all as specified and directed.
M&L Spreading and leveling the soils in layers not exceeding 25 cm thick each layer including watering and well ramming complete all as specified and directed.
M&L Hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 100 mm thick Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base, sub floor etc complete all as specified and directed.
M&L 25mm thick Plain cement concrete 1:2:4 type-B-1 (using 20 mm graded stone aggregate) as in floors for receiving tiles complete all as specified and as directed.
S & F pressed steel frames of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
Supply and Fixing 30 mm thick factory made flush shutter solid core construction with block board core and plywood face panels, commercial type on both faces complete all as specified and directed.
S&F 30mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); all as specified and directed.
M & L Preparation of new wood or wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over one coat of red oxide primer complete all as specified and directed
Note for item No 25 & 26:- (a) All synthetic enamel paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
Supply and fixing 100mm long Butt hinges medium weight cold rolled mild steel, and fixed complete all as specified and as directed.
Supply and fixing 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Supply and fixing 200 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed.
S&F 300mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminum alloy and fixed complete all as specified and as directed.
S&F Aluminium body door closer hydraulically regulated,designation No.3, universal type, suitable for door shutters of 851 to1000 mm in width and of weight between 61 to 80 kg and fixed complete as directed by Engr-in-charge.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 150mm complete all as specified and directed.
S&F Aluminium powder coated of three track sliding window outer frame top & sides (section no-20831) of size 92.0x31.75x1.5mm weighing 1.06 Kg/m, frame bottom (Section No 20832) of size 92.0x31.75x1.5mm weighing 1.248Kg/m , shutter to plain vertical (Section No 21093) of size 39x18x1.5mm weighing 0.634 Kg/m, shutter interlock vertical frame (section 21094) of size 39x18x1.55 weighing 0.734 Kg/m, shutter bottom horizontal frame (Section No 20551) size 40x20x1.5mm weighing 0.484 Kg/m, with powder coating of min thickness 50 micron , sliding type with out sash bars, 4mm thickness colour glass, rubber packing, snap beading screws with stainless steel wire mesh including locking arrangement complete all as specified and as directed.
M & L brickwork with fly ash’ bricks using old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed
Note for Item No 43 :- (a) Fly ash bricks shall be burnt clay flyash building bricks as per IS- 13757.
(b) The rates for work curved or polygonal on plan include for all extra cutting and extra waste in the body of the work. It shall be measured as mean length of wall.
(c) Sinking of steining shall be measured separately under relevent item. Well curbs, tie-rods, etc. shall be measured under the appropriate item.
(d) bricks shall be of class designation 75 (Kgf/cm).
(e) The quoted rate shall be deemed to be inclusive for all scaffolding, ladders, plant and templates required
(f) Exposed faces of brick work shall be fair.
(g) Exposed faces shall be facing with best bricks
(h) The quoted rate shall be deemed to be inclusive for Plumbing to angles
(j) Forming reveals to jambs where fair cutting on exposed faces shall not be involved
(k) The quoted rate shall be deemed to be inclusive for preparing tops and sides of existing walls and the like for raising and extending
(l) Building in vertical seismic reinforcement at the jambs of openings, corners of walls, etc.shall be grouting in cement mortar 1:4
M&L Rendering 10 mm thick in cement mortar 1:4 on fair faces of Brick masonry surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 15 mm thick in cement mortar 1:4 in two coats i.e 10mm thick cm (1:4) in first coat and 5mm thick in cm (1:4) mixed with WPC as per manufacturers instructions in second coat on Brick masonry surfaces or surface other than fair face of brickwork or on one side of lathing, finished even and smooth without using extra cement complete all as specified and directed. Note : Supply only WPC will be measured and paid separately.
M&L Rendering 5 mm thick in CM 1:3 on concrete ceiling surfaces and finish the surface even and smooth without using extra cement complete all as specified and as directed.
M&L Rendering 10 mm thick in cement mortar 1:3 on Brick masonry surfaces or surface other than fair face of brickwork or on one side of lathing, finished even and smooth without using extra cement complete all as specified and directed.
Note for Item No 55 to 58 :- The quoted rate shall be deemed to be inclusive for the following:- (a) Preparing the surfaces.
(b) Scoring surface of plastering for key, where the surface is not required to be finished fai
(c) Curing of plastered surface.
M&L Preparation of new plastered surface of wall and applying two coats of oil bound distemper over a coat of wall care putty of 2mm thick to achieve smooth surface of wall and one coat of alkali resistant primer complete all as specified and as directed.
M&L applying three coats of cement based paint, including preparation of newly plastered wall surfaces of any description, complete all as specified and as directed.
M&L 75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates), as in plinth protection/ path/ hardstanding including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including screed bed or bedding layer, 20 mm thick in Cement Mortar 1:6 including Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed. Note : The manufacturer's test certificate for tiles must be submitted for approval by the concerned authority prior to laying.
M&L Machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 10mm thick backing coat in Cement Mortar 1:3 including Roughening surfaces of old concrete/ brick wall by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed. Note : The manufacturer's test certificate for tiles must be submitted for approval by the concerned authority prior to laying.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soil all as specified and as directed.
Removing excavated soils to a distance exceeding 1.5 KM but not exceeding 5KM and depositing where directed complete all as specified and directed.
S&F Framed work such as grills , grating ,etc with ends of bars shouldered and or reveted for forged in to spike, framed guard bars barred iron doors, ladders, balusters, walk ways raling framed work for water tanks similar work confirming to Fe -290 Gde E-165 complete all as specified and directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints of 110 mm bore fixed to wall complete all as specified and as directed by Engineer-in-Charge
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints of 110 mm bore and laid in trenches complete all as specified and as directed by Engineer-in-Charge Note : Excavation and earth work shall be measured and paid seperately under relevent item.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints of 75 mm bore and laid in trenches complete all as specified and as directed by Engineer-in-Charge Note : Excavation and earth work shall be measured and paid seperately under relevent item.
S&F PVC (SWR) bends 110mm bore complete all as specified and as directed by Engineer-in-Charge
S&F PVC (SWR) bends 75mm bore complete all as specified and as directed by Engineer-in-Charge
S&F 20 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20oC) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, KPT, Prince
S&F 25 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20oC) UV stablised and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed. Make : SFMC, KPT, Prince
Note for item No 75 & 76 :- (a) The unit rate shall include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accssories such as pipe hooks, screws clamps etc
(b ) Wall thickness of pipes shall be all as per IS : 15801
S&F 20 mm outer dia PPR gate valve (brass insert) complete all as specified and directed
S&F 25 mm outer dia PPR gate valve (brass insert) complete all as specified and directed
M & L extra for forming fair finished drain or channel of 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified.
M&L Providing cement concrete type C2, 1:3:6 (using 40mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and as directed.
M&L Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate ) as in in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
M & L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified below:-
(a) Cleaning the surface with water and using wire brush including removing debris to out side the MoD land and providing following
(b) Rendering 10mm thick in cm (1:3) on concrete roof surface and finish the surface even and smooth without using extra cement including mixed with WPC @3% by weight of cement.
(c) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried.
(d) Providing APP modified water proofing as approved by GE weighing not less than 3kg per sqm unrolled over the bituminous coated surface with 100mm over laps, the overlap shall be sealed by flame as per manufacture instructions complete.
(e) Applying a coat of aluminium paint at the rate of 100 gm per sqm as per manufacture instruuction over bituminous layer complete all as directed.
Note for Item 84 :- (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
(ii) Measurements shall be for the surface of roof and vertical, curved or battered faces of parapet walls, abutments, chimney stacks, breasts, drain mouths, gutters, flashings, etc., covered with the waterproofing treatment. Turn ups and turn downs at eaves, verges, abutments, flashings, aprons, gutters, hips ridges, valleys, etc., shall be measured alongwith waterproofing treatment
(iii) Rates include for end and side laps, forming of openings, tucking in, wedging and pointing edges, tucked in brickwork or concrete fillet, all cutting and waste, and work in any position and any shape
Supply only integral water proofing compound
S&F Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl non metallic PVC Conduit with accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with modular white cover plate with frame etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for following :-
(a) One light point/fan/bell point controlled by one switch
(b) All as per item No. 94 here in before but for One 3 pin socket out 5 amp on the same board
(c) All as per item No. 94 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 94 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and Fix modular switch 1 way 6 amp.1 module complete all as specified and as directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular switch 1 way 16 amp.1 module complete all as specified and as directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular Socket, 6/16A - 2/3 pin combined 2 module complete all as specified and as directed. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular white cover plate with frame,3 module complete all as specified and as directed. . Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular white cover plate with frame,8 module complete all as specified and as directed. . Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
S&F metal flush box 3 module complete all as specified and as directed.
S&F metal flush box 8 module complete all as specified and as directed.
S&F electronic modular fan regulator 230 volts, step type socket type, hum free 120 watt 2 Module complete all as specified and as directed
S&F ceiling rose, surface type Bakelite 65x55mm 3 terminal complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Notes:- The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S&F factory made powder coated distribution board SP & N 4 way, double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make :- Siemens/ ABB/ Legrand
S&F MCB SPN 32 Amp , 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacityconforming to IS 8828 of 1996 complete all as specified and as directed Make/Model :- Legrand Cat Part No 408617 or equivalent. of Schnieder, Siemens.
Supply and fixing single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and as directed Make/Model :- Legrand Cat Part No 408587 to 408595 or equivalent. of Schniede, Siemens.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size rigid non metallic PVC conduit and all accessories fixed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor and PVC conduit shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F Triple pole Neutral MCB 63 Amp , 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified and as directed. Make/Model : Legrand Cat Part No 408683 or equivalent of Schnieder (Multi -9)/ L&T (Hegar).
S&F MCCB, 4 Pole, 63 Amps, thermal magnetic release adjustable type, 415 Volt, 25 KA breaking capacity along with metal enclosure including connecting with existing distribution panel using suitable size of aluminium lugs conforming to IS 8828 of 1996 complete all as specified and as directed. Make : Cat no 420053 of Legrand or equivalent in Siemens/ Schnieder/L&T
S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Havells/ Polycab
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as per specified and as directed. Note :- In case sufficient sand not obtained from excavation, the rate is deemed to be inclusive for additional qty of sand required to be obtain from out side MD land as directed by the Engineer-in-Charge.
S&F Fly ash bricks using old size bricks as in cable protection cover including taking down existing bricks of any size complete all as per specified and as directed.
Supply and fix GI pipe 40 mm bore light grade for cable protection complete all as specified and as dierced by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash
Removing excavated materials not exceeding 50m distance and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt Magnesium Sulphate (1 : 1: 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion, complete all as per specified and as directed.
Note for Item No 122 here in above :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester will be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth vesistance of less than 3 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
(e) Rate shall include GI strip and protection pipe of length up to 7.5m
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation all as specified and directed. Make : SafeTrode/ ISG Global/ ERICO.
Note for Item No 128 :- The unit quoted rate shall deem to be included for the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less than 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(vi) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vii) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(viii) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(ix) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(x) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xi) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(xii) The electrode shall carry manufacturer's name .
(xiii) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xiv) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( The rate of earthing strip up to 7.5 Mtrs is included in the quoted rate)
(xv) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvi) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xvii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xviii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
S & F in repairs Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model EGTEK3LC of ISG Global or equivalent in ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
S&F in repairs Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing
S&F in repairs Epoxy base insulators of suitable size 40mm height for fixing copper earth strip on wall/ceiling/floor/poles etc all as specified. NOTE : Quoted Unit Rate deem to be included drilling holes per Metre or as specified on GI/Aluminium/Copper Strip of any type and size.
M & L for recharging of existing defective earth pit after excavation up to one feet depth surrounding the earth pit as notified by the Engr-in-Charge and pouring 1 bucket of Recharge Hydrate crystalline gel earthing compound (6 KG /bucket) mixed with 10 litre water as per the manufactureres instructions for each earth pit to enhance the earth resistance complete all as specified and directed.
Note for Item No 150:- (a) Hydrate crystalline gel earthing compound shall be water soluble soil reactivation earthing compound.
(b) This compound shall be suitable for all type of existing earth pit.
(c) this compound shhall be environmentally & metallurgically safe non corrosive eco freindly.
(d) The purity of the compound shall be 98-100%
(e)The effectiveness of this compound shall be minimum 18 months
Material and labour, earthing complete with copper earth plate electrode of size 600mm x 600x 3.15 mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level),with top edge of earth plate not less than 1.5m below normal ground level, eart plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, magnesium sulphate (1 : 1 : .5), electrode connections using copper strip of size 20 x 3 mm thick (upto body of equipment) by means of brazing / welding conencted to main switch board or main control board or test point, protected by galvanised iron pipe light grade 40mm dia bore nd watering pipe 20mm dia bore GI medium grade with funnel and wire mesh including all necessary(excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in elctrical plate No 3 of MES schedule Part-I (2009), testing on completion, complete all as specified and directed.
Notes for Item No 156:- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80 mm thick reinforced with XPM not less than 4Kg/ Sqm.
(ii) PCC pit cover shall be constructed 500mm away from the edge of eath pit.
(iii) Rate shall include Copper strip and protection pipe of length 7.5m, excess beyond 7.5m lenth required at site shall be measured and paid separately.
(iv) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned.
(v) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(vi) Earth resistance should be less than 3 Ohm, In case the test results are not found below 3 Ohm, complete earthing will redone without any extra cost to Govt.
Supply and fix in repairs 3/8" gun metal ball valve with H nipple for Pressure Guage of fire fighting system etc complete all as specified and directed
Supply and fix in repairs 1/4" gun metal ball valve with H nipple for pressure switch of firefighting system etc complete all as specified and directed
Supply and fix in repairs Aircushion tank 8 inch dia made of 18 guage MS sheet with drain line of fire fighting system etc complete all as specified and directed
Supply and fix in repairs 1/2" Gland packing rope for main pump, jockey pump and diesel pump of fire pump installation etc complete all as specified and directed
Supply and toping up of SAE 15 W - 40 grade API 4 plus type in sealed container for DG set Top up and change the oil in the sump after completely flushing the old oil from the tank/sump and cleaning of the same complete all as specified and directed by Engineer-in-charge (Make : Castrol/Valvoline/Servo)
Supply and fix in repairs stainless steel Bolt, nut, gasket for Y stainer in diesel engine pump of SRE fire fighting system etc complete all as specified and directed
Supply and fix in repairs gun metal ball valve of size 25mm dia with nipple for Air release in fire hydrant complete all as specified and directed
S&F in repairs Non return valve gun metal (ISI marked), PN 1.6 for 80mm dia bore pipe, including taking out old and removal, complete all as specified and directed. Make: Kirloskar/SANT/Zoloto
Supply and fix in repair of fire 4 way inlet gun metal valve on fire hydrant with isolating valve and instataneous gun metal coupling 63 mm dia including with all accessories complete all as specified and directed.
S&F in repair Butterfly valves of 150mm bore including joints with rubber gasket and jointing materials bolts, nuts, washers, including taking out existing unserviceable butterfly valve complete all as specified and directed
M&L for pressure testing tray arrangement of existing 150/80/50 mm DI/MS fire main system , identifying for leakages for rectifications including replacement of gland packing of sluice valves, rubber insertion packing, nut, bolts etc of flanged joints/ defective flanges etc complete for making the system leak proof complete all directed by Engineer-in-charge. Location :- SRE Bldg, Note : (a) The rate quoted is deemed to be inclusive of T&P required such as air compressor etc for pressure testing (b) The pressure testing procedure of fire fighting system shall be done as per manufacturer's recommendations all as specified and directed. complete all as specified and directed
S & F for Drain line made of GI pipe of 80 mm bore medium grade connected with main header pipe of size 100 mm including all jointing materials and one butterfly valve to facilitate recycle the water to sump complete all as specified and directed
Supply and fix in repairs 12 V, 7 AH, Battery for agent release panel of SRE bldg fire fighting system complete all as specified and directed. Make : EXIDE/ Amaron/ Amar Raja
Supply and fix in repairs Mild steel fire hydrant valve cap of size 63mm dia including with all accessories complete all as specified and directed
Supply and fix in repairs single way Gun metal fire hydrant valve of size suitable for 63mm dia pipe including with all accessories at SRE complete all as specified and directed
S&F in repairs 4 way inlet gun metal valve on fire hydrant with isolating valve and instantaneous gun metal coupling 63mm dia incl with all accessories complete all as specified and directed.
S&F in repairs of unserviceable gun metal Air release valve of size 25mm dia completed all as specified and directed.
Supply and fix in repairs Hose reel drum with CP hose pipe 63 mm dia 15 mtr length including terminal brass jet complete all as specified and directed.
Supply and fix in repairs 150 mm dia medium grade GI pipe with all accssories including jointing materials complete all as specified and directed
Supply and fix in repairs Butterfly valves of 150mm bore including joints with rubber gasket and jointing materials bolts, nuts, washers,complete all as specified and directed
Supply and fix in repairs Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as in support suitable for Fire hydrant pipe of any dia. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed
M&L servicing of defective 60 HP Jockey pump by tightening of nut and bolts, checking of all electrical connections for the inproper tightness and leakages if any, greasing in all grease points, replacemnet of glands packing gun metal bushes complete all as specified and directed. Location :- DWR
Supply and fix in repairs 0.6 meter long connecting hoses made of MS pipe of size 63 mm dia for reel drum complete all as specified and directed.
Supply and fix in repairs Pressure release valve with pressure range 0 to 150 Kg/ Cm2 at DWR bldg complete all as specified and directed.
Supply and fix in repairs Gun metal lugs for cable connection at New ATC bldg complete all as specified and directed.
Supply and fix in repairs 63 mm dia Mild steel Hose coller with hose gunmetal nozzle at New ATC bldg complete all as specified and directed.
Supply and fix in repairs canvas Hose of size 63 mm dia and 15 meter length at New ATC bldg complete all as specified and directed.
Supply and fix in repairs CI foot valve 100mm dia to suction line of exisiting pumping set with bolts, nuts, rubber packings, etc complete all as specified and directed.
Supply and fix in repairs Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and directed.
Supply and fix in repairs detectors complying with and type certified to EN-45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS:11360 complete all as specified and directed.
Supply and fix in repairs detectors complying with and type certified to EN-45 Addressable type heat detector with base with rate of rise cum fixed temperature as per IS : 2175 complete all as specified and directed.
Supply and fix in repairs detectors complying with and type certified to EN-45 Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relay type module) complete all as specified and directed.
Material and labour for replacement of unserviceable valve for existing CO2 based including following repairs and replacements :-
(i) Valve CO2/12mm dia/25E EN-629-1/B.Disc 250Bar/Diff pressure/Vds/LPCB (for main+slave Co2 valve) - 06 Nos
(ii) Elec-mag R. Device - B0480-24 VDC/Diode/mini design/Vds -02 Nos.
(iii) Manual-pneumatic release - B0480 single piston -actuation 21 bar /Vds/LPCB - 04 Nos
(iv) Pilot hose 700 mm/M12x1.5/Internal dia 1/8"-DN6/Vds -02 Nos
(v) Pilot hose 500 mm/M12x1.5/Internal dia 1/8"-DN6/Vds -04 Nos
(vi) Adapter for pilot hoses / M12 X 1.5 / G 1/8"/with O-ring - 12 Nos
(vii) Bleed valve for Pneumatic actuator /G 1/8"/Vds tested -02 Nos
(viii) Discharge Hose -W 21.8x1/14"DIN 90 deg -G 3/4"/L =450 /DN 12/ 380 bar/Vds - 06 Nos
(ix) Check valve - for IG /CO2 / Clean agent valves B0480-B 0439/DN 12/WP 360 bar / Inlet G 3/4"/Outlet R 1"/Vds -06 Nos
(x) Pressure and flow detector/switch 2 bar/BSPP G 1/2"-01 No
(xi) Nozzle -IG /Co2/BSP R 1/2"to R 1/2"/ Rx orifice 3 mm dia - 25.5 mm dia / Vds (IG-CO2) - 06 Nos
(xii) Removing of existing u/s pipeline and total replacement of seamless schedule 40 pipe including necessary fitting with one coat of primer and two coat fire red enamel painting as required -1 Job.
(xiii) Replacement for 6 cylinders/ 2 row -1 Job (Capacity of each cylinder shall be 37.8Kg)
(xiv) Installation, testing & commisioning of total flooding fire suppression system - 1 Job.
Neptune Engineers and Builders
shalom constructions
A.GOVINDARAJ
devan enterprises
UNIVERSAL ENGINEERING
ARCHANA CONSTRUCTION CO
M AND V ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .