Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Tender | |
| 2 | L2₹29.7 L+₹38,178.67 (1.30%)Rejected-Finance N A | NA | NA | 121004 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹30.5 L+₹1.1 L (3.88%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹32.1 L+₹2.8 L (9.47%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹35.6 L+₹6.2 L (21.2%)Rejected-Finance H NO 82 C BLOCK NO CC SHALIMAR BAGH DELHI 110088 | DELHI | NORTH DELHI | DELHI | 110088 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹75,200
Closing Date
22 Mar 2021, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR TO PLINTH PROTECTION ROOF TREATMENT CI PIPES GI PIPES AND OTHER CONNECTED WORKS AT CAMS 1 CBPO AND YOGENDER VIHAR UNDER AGE B/R-I (S) GE (SOUTH) DELHI CANTT-10
2021_MES_424583_1
GE/DS-74/2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹75,200
Yes
21 May 2021
22 Feb 2021
24 Mar 2021
22 Feb 2021
22 Mar 2021
8 Mar 2021
23 Feb 2021 - 6 Mar 2021
Amount
Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
Demolition of mud in roof, any thickness, including plastering and leeping incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area or complete all as specified and directed by Engineer-in-charge.
M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm on existing surfaces complete all as specified and directed by Engineer-in-charge.
M&L for 40 mm thick (average thickness) plain cement concrete 1:2:4 type B-0 using (12.5 mm graded aggregate), as in roof ,padding to maintain the uniform slope complete all as specified and directed by Engineer-in-charge. Note : - WPC shall be measured & paid separately.
M&L for rendering 15 mm thick (average) plaster on concrete surfaces in CM (1:4) on roof, mixed with water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
S&F APP based polymeric water proofing membrane minimum weighing 3 Kg/sqm and 3mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm laid over and including applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm by torch application including cleaning of surface complete all as per approved manufacturer's instructions. complete all as specified and directed by Engineer-in-charge. Note:-The water proofing treatment shall be carried out by manufacturer or their auth applicators as per manufactures instruction and as directed by Engr in Charge.
M&L for cement concrete tiles 25cmx25cmx22mm thick laid over and including 20mm thick screed in cement mortar 1:6 and jointed grouted and pointed in CM 1:3. complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specially provided for complete all as specified and directed by Engineer-in-charge.
M&L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete all as specified and directed by Engineer-in-charge.
Supply only water proofing compound.(ISI Marked.Sika or equivalent) complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Roughening surfaces of old concrete floor/wall by picking, sweeping clean and washing down with water to remove dust, etc and brushing and applying neat cement slurry with 3.0 Kg of cement per sq metre complete all as specified and directed.
M&L for Glazed Ceramic coloured tiles in vertical surface 450X350X7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick backing coat of cement mortar (1:4), complete all as specified and directed by Engineer-in-charge.
M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 15mm thick in CM 1:6 complete all as specified and directed by Engineer-in-charge.
M&L for non Skid ceramic tiles 7 to 8mm thick coloured & joint free (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-charge.
All as per item No 15 here in before but as in skirting laid over and including 10mm thick backing coat of cement mortar (1:4), complete all as specified and directed by Engineer-in-charge.
M&L for 15 mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes, complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Vitreous China, pedestal pattern wash down water closet pan, white including fixing bolts, connection to flushing cistern and flush pipe & drain pipe (or out going pipe) and to flushing pipe, anti-syphonage pipe, etc complete all as specified and directed by Engineer-in-charge.
S&F in repair plastic water closet seat, white, closed pattern ( seat & cover for Pedestal pattern) with flat bottom, and cover and mild steel chromium plated or aluminium hinging device, complete all as specified and directed by Engineer-in-charge.
S&F in repairs low level flushing cistern of 10 ltrs capacity PVC valveless, syphonic action type, white with inlet ball valve float and handle complete all as specified and directed by Engineer-in-charge.
S&F in repairs PVC connections 450mm long with brass unions at both ends suitable for 15mm bore pipe, complete all as specified and directed by Engineer-in-charge.
S&F in repair Vitreous china wash hand basin with pedestal white, flat back, size 550 x 400mm, including necessary waste pipe and coupling, brackets and cutting for and pinning in ends of brackets, complete all as specified and directed by Engineer-in-charge.
S&F in repairs elegent mirror PVC cabinet (PTMT alloy) complete all as specified and directed by Engineer-in-charge. (Make: Prayag, Cat No 551 or equivalent as approved by GE.
S&F in repairs 32mm bore of Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia D type , 60 cm long between flanges complete all as specified and directed by Engineer-in-charge.
S&F in repairs brass chromium plated shower rose of size 125 mm with arms including fixing to steel pipe complete all as specified and directed by Engineer-in-charge.
S&F in repair Conceeled stop cock,15 mm bore, chromium plated ,with long shank and cup, fancy type, complete all as specified and directed by Engineer-in-charge.
S&F CP jet spray with suitable PVC flexible pipe of 15 mm bore complete all as specified and directed.
S&F in repairs Chromium plated Pillar tap cast copper alloy with capstan heads screwed down high pressure screwed to 15 mm bore iron pipe complete all as specified and directed by Engineer-in-charge. (Make- Parko/Prayag/Kingston)
S&F in repairs bib tap, brass chromium plated fancy type, long body screwed down, screwed for iron pipe 15 mm bore complete.
S&F in repair 15 mm dia brass chromium plated angle valve screwed at ends including necessary extention piece and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs Cast iron floor trap with grating including jointing to waste pipe in run lead, dia of outlet 100mm in cement concrete type B1 (1:2:4) complete all as specified and directed by Engineer-in-charge.
S&F in repairs Cast iron floor trap with grating including jointing to waste pipe in run lead, dia of outlet 75 mm in cement concrete type B1 (1:2:4) complete all as specified and directed by Engineer-in-charge.
S&F in repairs Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including supply & fixing cantilever brackets of mild steel angle 35 x 35 x 5 mm and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed by Engineer-in-charge.
Supply and fix PVC waste pipe 32/40 mm bore, 65 cm long complete all as specified and directed by Engineer-in-charge.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed by Engineer-in-charge.
M&L for prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed to timber frame work, 18/19 mm thick complete all as specified and directed by Engineer-in-charge.
S&F 75 mm size butt hinges medium weight cold rolled mild steel complete all as specified and directed by Engineer-in-charge.
S&F aluminium alloy handles extruded, fabricated type, anodised ,of 100 mm size. complete all as specified and directed by Engineer-in-charge.
S&F Hasp and staple -100 mm size, safety type, aluminium anodised including bolt to hinge plate, fixed with screws complete all as specified and directed by Engineer-in-charge.
S&F Floor door stopper (bouble legged)of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor; overall length of cover plate 150mm complete all as specified and directed by Engineer-in-charge.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed by Engineer-in-charge.
S&F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube ,supplying and fixing in opending as per direction of engr-in-charge or all as speccified
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be coloured with heat mould plain coloured PVC'C channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stills and plain colour PVC sheet for top rail lock and botton rail either side and as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading. And jointed together with solvent cement suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed by Engineer-in-charge.
S&F stainless steel butt hinges,size 100 mm complete all as specified and directed by Engineer-in-charge.
S&F aluminium anodised, barrel tower bolts of extruded section 200 mm long complete all as specified and directed by Engineer-in-charge.
S&F 150 mm aluminium handles anodised fabricated type complete all as specified and directed by Engineer-in-charge.
S&F 25mm dia MS drapery curtain rods, (Powder coated/rubber coated), including MS bracket powder coated and PVC powder coated side bulb complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-charge.
M&L for Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, 75mm thick, finished fair and even without using extra cement, complete all as specified and directed by Engineer-in-charge.
M&L for 100mm th PCC 1:2:4 type B2 (40mm graded aggregates) as in finishing cement concrete surface even and smooth with out using extra cemen complete all as specified and directed by Engineer-in-charge..
M&L for forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and directed by Engineer-in-charge.
M&L for cutting chases or making holes, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing 15 mm bore and connection including cleaning for refixing. complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing 20 mm bore and connection including cleaning for refixing. complete all as specified and as directed byEngineer-in-Charge
S&F 15 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors or concealed, complete all as specified and directed by Engineer-in-charge.
S&F 20 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors or concealed, complete all as specified and directed by Engineer-in-charge.
Refixing of old steel tubing and connection in new or old position (Wall/Ceiling etc) incl cleaning for refixing, bore of pipe 15 mm dia complete all as specified and directed by Engineer-in-charge.
Refixing of old steel tubing and connection in new or old position (Wall/Ceiling etc) incl cleaning for refixing, bore of pipe 20 mm dia complete all as specified and directed by Engineer-in-charge.
Dismantling water tanks of capacity exceeding 250 litres but not exceeding 500 litres complete all as specified and directed by Engineer-in-charge.
S&F 500 ltr capacity triple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part II complete all as specified and directed by Engineer-in-charge.
S&F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 15 mm bore complete all as specified and directed by Engineer-in-charge.
S&F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore complete all as specified and directed by Engineer-in-charge.
S&F Ball brass valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball ascrewed for iron pipe of 20mm bore and fixed complete all as specified and directed by Engineer-in-charge.
Dismantling and breaking up CI pipes set in CM, 100/75 mm dia pipe complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI soil, waste and vent pipe in any length with or without ears, with cement joints, fixed to walls of 100 mm dia sand cast pipe complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI soil, waste and vent pipe in any length with or without ears, with cement joints, fixed to walls of 75 mm dia sand cast pipe complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI Bends (any radius ), diminishing pieces or tapers of 100 mm dia fitted with oval access door complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI Bends with access door (any radius ), diminishing pieces or tapers of 100 mm dia without oval access door complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI Bends (any radius ), diminishing pieces or tapers of 75 mm dia fitted with oval access door complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI Bends (any radius ), diminishing pieces or tapers of 75 mm dia fitted without oval access door complete all as specified and directed by Engineer-in-charge.
S&F in repairs Cast iron branch pieces, Tee, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, 100 mm bore with cement joints, fitted with oval access doors complete all as specified and directed by Engineer-in-charge.
S&F in repairs Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, 75 mm bore with cement joints, fitted with oval access doors complete all as specified and directed by Engineer-in-charge.
S&F 100 mm cast iron sanitary connections short connections pipe of length upto 300 mm complete all as specified and directed by Engineer-in-charge.
S&F Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for 100 mm bore pipes complete all as specified and directed by Engineer-in-charge.
S&F Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for75mm bore pipes complete all as specified and directed by Engineer-in-charge.
Taking down rain water pipe (any size) or pattern incl all fittings, head shoes, bends swan necks etc incl cleaning or re-fixing or removal to store(measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed by Engineer-in-charge.
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, of 110 mm dia complete all as specified and directed by Engineer-in-charge.
S&F PVC (SWR) bends any radius 110mm dia bore complete all as specified and directed by Engineer-in-charge.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
M&L for rendering 10mm thick in cement mortar 1: 4 on faces of brick work or concrete surfaces, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick in cement mortar 1: 6 on faces of brick work or concrete surfaces, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for rendering 5mm thick in cement mortar 1: 3 on concrete surfaces of ceiling,chajja,etc finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered wall surfaces and applying two coats of cement base paint, white or tinted (colour and shade as per new colour scheme approved by GE) over a coat of primer of same make including scaffolding for four storey building complete all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care Putty complete all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
Demolition of brick work built in cement or cement lime mortar complete all as specified and directed by Engineer-in-charge.
M&L for brick work in cement mortar (1:6) using sub class 'B' bricks, straight or curved on plan exc 6 mtr mean radius complete all as specified and directed by Engineer-in-charge.
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed by Engineer-in-charge.
M&L for sand filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and directed by Engineer-in-charge.
M&L for removing excavated soils exc. 500m and and n. ecx 500 mtr depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed by Engineer-in-charge.
S&F SFRC manhole cover 'medium duty' of overall size 450mm dia factory made complete all as specified and directed by Engineer-in-charge. Notes: - (i) Make of SFRC Manhole/drain cover and frame : (a) M/s Polycrete. (b) M/s KK Manhole.(c) Or equivalent as approved by GE” (ii) Contractor will provide manufactuerer test certificate of SFRC cover & frame
S&F SFRC manhole cover 'medium duty' of overall size 450mm x 450mm factory made complete all as specified and directed by Engineer-in-charge. Notes: - (i) Make of SFRC Manhole/drain cover and frame : (a) M/s Polycrete. (b) M/s KK Manhole.(c) Or equivalent as approved by GE” (ii) Contractor will provide manufactuerer test certificate of SFRC cover & frame
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Vipul Construction
SABHARWAL CONSTRUCTION CO.
Chaudhary Constructions
M/S GOPAL JEE SINGH
M/S.Parmod Johar
P R Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .