Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.1 L+₹2,690 (2.48%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹1.2 L+₹6,625 (6.11%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹1.2 L+₹12,148 (11.2%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹1.6 L+₹50,774 (46.8%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹1.9 L
Closing Date
20 Dec 2021, 9:30 amClosed
Executive_Engineer
EE, EandM, Division, APWD, Prothrapur, Port Blair
Construction of HAAT Opposite to Labour Barrack of Agriculture Department including Toilet Block and Chain Link Fabric Fencing at Sippighat SW Providing IEI
2021_APWD_4560_1
NIT No. 71/EE/EandM/21-22
Open Tender
Electrical Works
Item Rate
30 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
31 Dec 2021
10 Dec 2021
20 Dec 2021
10 Dec 2021
20 Dec 2021
15 Dec 2021
11 Dec 2021 - 14 Dec 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required a) 20 mm
Supplying and fixing Plastic Board of 3.5"x6" on surface including providing and fixing 5 pin 5/6 (2&3 pin) amps socket outlet and 5/6 A, P.T switch, connection, painting, etc as required.
Supplying and fixing Plastic Board of 3.5"x8" on surface including providing and fixing 6 pin & 6/16 amps socket outlet and 16 A, P.T switch connection, painting, etc as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 12 way , Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required a) 40 A
Supplying and fixing of surface mounted LED batten Fitting for 20 Watt T-8 Lamp Similar to Crompton Cat No.DMLN1LT8-16 with 20W Retro fit LED Lamp Crompton Cat No.LT8-20-865-2 or its equivalent as required
Supplying and fixing Bakelite batten/ angle holder including connection etc. as required.
Supplying of 9 Watt LED Lamp in the existing Batten Holder similar to C&S Cat No. LTHPLED LAMP9W/ B22 as required.
Supplying of 12Watt LED Lamp in the existing Batten Holder similar to C&S Cat No. LTHPLED LAMP12W/ B22 as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supplying of AC Ceiling Fan 1200mm Sweep (Colour: White/Brown ) similar to Crompton empower 50 - 1 Star & ISI without regulator or its equivalent as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing of 30W LED Street light Light fitting similar to C&S Cat No. LTESSE30WLED or its equivalent including clamping suitable bend pipe on wall with MS Clamp as required.
Supplying and fixing of 45 W LED Street light Light fitting similar to C&S Cat No. LTESSE45WLED or its equivalent including clamping suitable bend pipe on wall with MS Clamp as required.
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2 mtr, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Providing and fixing hot press moulded sintex single phase SMC meter box Hinged (L)of size 310 x 285 x180 mm (out side) for accommodating one LT 1 phase KWh meter with cut out similar Cat No. GSJB 2525 etc. as required.
DILIP RAJ
NAVJEEVAN ENTERPRISES
M/s G K Construction
MILESTONE ENGINEERING
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .