| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 LAccepted-AOC AT WASHERY ROAD KATHARA BOKARO JHARKHAND 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | 1 | Accepted-AOC Accepted | |
| 2 | Rejected-Technical NEAR HOSPITAL KATHARA PO KATHARA DIST BOKARO JHARKHAND | KATHARA | BOKARO | JHARKHAND | - | Rejected-Technical Not evaluated as not L1 | |
| 3 | Rejected-Technical WASHERY RD KATHARA BOKARO JHARKHAND 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Not evaluated as not L1 |
Tender Value
Refer Docs
EMD Value
₹2,100
Closing Date
19 Mar 2024, 4:00 pmClosed
Staff officer ENM
Office of the staff officer EnM kathara Area
Electrical repairing / rewiring and changing of electrical items for Community Centre Shive Mandir at Railway Colony under G.M.Unit,Kathara Area
2024_CCL_304190_1
GMKTA/SOEnM/E-tender/23-24/33
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Kathara Area
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,100
24 May 2024
8 Mar 2024
20 Mar 2024
9 Mar 2024
19 Mar 2024
9 Mar 2024
9 Mar 2024 - 15 Mar 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Groug-C.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. : 5/6 amps switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. : 3 Pin 5/6 amps Socket out let.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator: 2 + 6 way/ 8 way , Double doo
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required :. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wir.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1.14.1 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wir
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1.14.1 2 X 4 sq. mm + 1 X 4 sq. mm earth wir
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 100 Amp TP&N.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm.
Total impact of GST for the purpose of CTC
M/S A.K. TRADING
M/S REGAL TRADING AND COMPANY
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_315126.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .