| 1 | 1₹8.6 LAccepted-AOC 5A 24 ANSARI ROAD DARYA GANJ NEW DELHI 110002 | CENTRAL | DELHI | 110002 | 1 | Accepted-AOC L1 | |
| 2 | 2₹8.8 L+₹14,073 (1.63%)Rejected-Finance U 57 OPP AGGARWAL NURSING HOME RAJU GAS AGENCY OFFICE VIJAY NAGAR NARELA DELHI DELHI 110040 | NORTH | DELHI | 110040 | 2 | Rejected-Finance 2 | |
| 3 | 3₹9.1 L+₹48,397 (5.62%)Rejected-Finance B 17 2 GALI NO 20 JITAR NAGAR NEAR PARVANA ROAD KRISHNA NAGAR EST DELHI 51 | NEW DELHI | DELHI | 110001 | 3 | Rejected-Finance 3 | |
| 4 | 4₹9.1 L+₹49,063 (5.70%)Rejected-Finance | 4 | Rejected-Finance 4 |
Tender Value
₹10.4 L
EMD Value
₹20,710
Closing Date
27 Dec 2023, 11:00 amClosed
EEE-II/CLZ
EEE-II/CLZ
Provision of Semi High Mast Poles and street light with LED lights at sizara road sankarpura Burari Ward No. 06/CLZ.
2023_MCD_178598_1
EEE-II/TC/2023-24/33.6
Open Tender
Electrical Works
Item Rate
60 days
EEE-II/CLZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹20,710
4 Apr 2024
20 Dec 2023
28 Dec 2023
20 Dec 2023
27 Dec 2023
20 Dec 2023
Amount
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.2.19:Fabrication,Supplying,Installation,testing,Commissioning of 12 mtr high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame ,2 point suspension system, 5*2.5 sqmm Cu conductor with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.
122.2.25:Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.33:SITC of 60W LED Street Light luminaire fitted with lens, top opening driver cover made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
OD14035/2023-2024:Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd.
OD14036/2023-2024:Supplying & laying of following size DWC HDPE pipe ISI marked alongwith all accessories like socket,bend,couplers etc.conforming to IS 14930 Part-II complete with fitting & cutting,jointing etc.direct in ground (75 cm.below ground level) i/c excavation & refilling the trench but excluding sand cushioning & protactive covering etc.complete as reqd.(a)63 mm dia.(OD 63 mm & ID 51 mm.minimum)
OD14037/2023-2024:Supplying & laying of following size DWC HDPE pipe ISI marked alongwith all accessories like socket,bend,couplers etc.conforming to IS 14930 Part-II complete with fitting & cutting,jointing etc. etc.in the existing trench,complete as reqd.(a)63 mm dia.(OD 63 mm & ID 51 mm.minimum)
OD14038/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.(a)Upto 35 sq. mm
OD14039/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.(a)Upto 35 sq. mm
OD14040/2023-2024:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD14041/2023-2024:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
OD14042/2023-2024:Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd
OD14043/2023-2024:Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required (a) 3 x 1.5 sq. mm
OD19737/2023-2024:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
OD19738/2023-2024:Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metrers
DELIGHT TRADING COMPANY
bharat electricals & electronics
Kamal Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .