Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC 1074 BAGYALAKSHMI STREET VENKATESAPURAM ARAKKONAM 631002 | ARAKKONAM | RANIPET | TAMIL NADU | 631002 | L1 | Accepted-AOC ACCEPTED BEING L1 | |
| 2 | L2₹42.1 L+₹2.2 L (5.44%)Rejected-AOC 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L2 | Rejected-AOC REJECTED DUE TO NOT BEING L1 | |
| 3 | L3₹44.9 L+₹5.0 L (12.4%)Rejected-AOC | L3 | Rejected-AOC REJECTED DUE TO NOT BEING L1 |
| Sl No | Description | Qty | Unit | rc enterprises L2 | Green Ray Technologies L3 | m/s SRI VALLI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5mtr wide & not exceeding 1.5 mtr deep getting out in soft /loose soil for taking up/laying CI/GI pipe complete all as specified and directed by Engr-in-charge. | 460 | CUM | 279 ₹1,28,340 Lowest | 300 ₹1,38,000 | 279 ₹1,28,340 Lowest |
| 2.00 | Returning, filling in trenches (Soft/Loose soil) in layers not exceeding 25 cm thick after laying of pipe including spreading, levelling & well ramming including watering as required complete all as specified and directed by Engr-in-charge. | 390 | CUM | 70 ₹27,300 Lowest | 150 ₹58,500 | 90 ₹35,100 |
| 3.00 | Removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above from the starting point complete all as specified and directed by Engr-in-charge. | 70 | CUM | 90 ₹6,300 Lowest | 280 ₹19,600 | 108 ₹7,560 |
| 4.00M&L for rectifying leakage of GI pipe line including excavation in mud (not exc. 0.7m x0.7mx0.7m) and making arrangement for dewatering by using electric/diesel pump/manual additional labour, taking out existing joint and making joint including providing all GI fittings i.e. socket, tee, elbow , nipples upto 6'' length, GI unions, Reducer (Except GI pipes) complete all as specified and as directed for following size of pipe lines:- | ||||||
| 4.01 | 80 mm bore. | 30 | Each Job | 720 ₹21,600 Lowest | 2,500 ₹75,000 | 1,080 ₹32,400 |
| 4.02 | 32 to 50 mm bore. | 30 | Each Job | 540 ₹16,200 Lowest | 1,800 ₹54,000 | 720 ₹21,600 |
| 4.03 | 15 to 25 mm bore. | 30 | Each Job | 360 ₹10,800 Lowest | 1,600 ₹48,000 | 630 ₹18,900 |
| 5.00Taking up or down steel tubing of following sizes from roof/ ceiling /wall /trenches complete all as specified and as directed. Note: Excavation and earth work shall be measured and paid separately under relevant items. | ||||||
| 5.01 | 15 mm bore of pipe | 200 | RM | 9 ₹1,800 Lowest | 15 ₹3,000 | 18 ₹3,600 |
| 5.02 | 20mm bore of pipe | 280 | RM | 9 ₹2,520 Lowest | 20 ₹5,600 | 18 ₹5,040 |
Tender Value
₹43.0 L
EMD Value
₹85,980
Closing Date
27 Aug 2026, 6:00 pmClosed
Garrison Engineer (M) NAS Arakkonam
Garrison Engineer (M) NAS Arakkonam 631006
REPAIR AND MAINTENANCE OF EXTERNAL WATER SUPPLY PIPE LINES VALVES VALVE CHAMBERS AND ALLIED WORKS AT ZONE A UNDER GE M ARAKKONAM
2026_MES_781853_1
8606E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (M) NAS Arakkonam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer (M) NAS Arakkonam
₹85,980
Yes
25 Sept 2026
30 Jul 2026
29 Aug 2026
30 Jul 2026
27 Aug 2026
13 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches not exceeding 1.5mtr wide & not exceeding 1.5 mtr deep getting out in soft /loose soil for taking up/laying CI/GI pipe complete all as specified and directed by Engr-in-charge. | 460 | CUM | - | - |
| 2 | Returning, filling in trenches (Soft/Loose soil) in layers not exceeding 25 cm thick after laying of pipe including spreading, levelling & well ramming including watering as required complete all as specified and directed by Engr-in-charge. | 390 | CUM | - | - |
| 3 | Removing surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above from the starting point complete all as specified and directed by Engr-in-charge. | 70 | CUM | - | - |
| 4M&L for rectifying leakage of GI pipe line including excavation in mud (not exc. 0.7m x0.7mx0.7m) and making arrangement for dewatering by using electric/diesel pump/manual additional labour, taking out existing joint and making joint including providing all GI fittings i.e. socket, tee, elbow , nipples upto 6'' length, GI unions, Reducer (Except GI pipes) complete all as specified and as directed for following size of pipe lines:- | |||||
| 4.01 | 80 mm bore. | 30 | Each Job | - | - |
| 4.02 | 32 to 50 mm bore. | 30 | Each Job | - | - |
| 4.03 | 15 to 25 mm bore. | 30 | Each Job | - | - |
| 5Taking up or down steel tubing of following sizes from roof/ ceiling /wall /trenches complete all as specified and as directed. Note: Excavation and earth work shall be measured and paid separately under relevant items. | |||||
| 5.01 | 15 mm bore of pipe | 200 | RM | - | - |
| 5.02 | 20mm bore of pipe | 280 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
Tenderdocuments8606.pdf
Tender Documents • 1.40 MB
NIT8606.pdf
Additional Documents • 0.54 MB
BOQ_875873.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .