Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | L1 | Accepted-AOC Low | |
| 2 | L2₹30.9 L+₹1.4 L (4.63%)Rejected-AOC | L2 | Rejected-AOC High | |
| 3 | L3₹36.7 L+₹7.2 L (24.5%)Rejected-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L3 | Rejected-AOC High | |
| 4 | L4₹37.0 L+₹7.5 L (25.4%)Rejected-AOC | L4 | Rejected-AOC High | |
| 5 | L5₹40.1 L+₹10.6 L (35.9%)Rejected-AOC | L5 | Rejected-AOC High |
Tender Value
₹33.8 L
EMD Value
₹67,600
Closing Date
19 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Sachin Jaiswal, IDSE, CWE Chandimandir
HQ CWE Chandimandir
CA NO. CWE/CHM(U)-73/2022-23 PROVN OF INTERCONNECTION OF PIONEER SUB STN AND SS 5B AT CHANDIMANDIR
2023_MES_579514_2
CWE/CHM(U)-73/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE Chandimandir
Class D category b(ii)
8 documents required · 8 mandatory
₹500
Yes
GE(U) Chandimandir
₹67,600
Yes
13 Jun 2023
28 Mar 2023
24 Apr 2023
28 Mar 2023
19 Apr 2023
5 Apr 2023
29 Mar 2023 - 1 Apr 2023
Amount
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for laying of cable,poles etc. and getting out complete all as specified and directed.
All as per Item No. 1.00 above but depth exe 1.5 mtr and not exe 3.0 mtr complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HPV, type 1 flat , size 300mm x 180mm x 40mm complete all as specified and directed.
Material and Labour dry sand filling under and around UG cable to provide cushioning complete all as specified and directed.
Supply and fix in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, 11000 volts grade cross sectional area 185 sqmm 3 core, 11 KV earthed, complete all as specified and directed.
Supply and fix HT heat shrinkable type outdoor end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 185 Sqmm, 3 core complete all as specified and directed.
Supply and fix HT heat shrinkable type indoor end termination cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 185 Sqmm 3 core complete all as specified: -
Supply and fix HT heat shrinkable type straight through cable jointing kit with jointing material and accessories suitable for 11000 volt (Earthed) grade XLPE cable of size 185 Sqmm 3 core complete all as specified and directed.
Supply and fix steel tubular swaged poles complete with mild steel base plate, closed at top as specified, type 410 SP-55 (11 metre long) including painting with two coats of black bitumonous paint externally up to the planted depth , internally through out and remaining external portion with two coats of aluminium paint , over a coat of red oxide primer complete all as specified and directed. NOTE: Excavation & earthwork, foundation concrete will be meaured & paid for separately under respective item(s).
Supply , install, testing and commissioning of indoor type Vacuum Circuit Breaker independent panel as Incoming cum Outgoing with possibility of future extension at side, capacity 11 KV, 800 Amp, 3 Phase, 3 wire, 50 Hz, having a rupturing capacity of 350 MVA at 11 KV , 25 KA breaking capacity for 3 sec, Internal arc type tested for 25 KA for 1 sec with AFLR classification, totally enclosed with extended bus bar of 800 Amps for each phase, floor mounting, metal clad, Indoor extensible type , flush front, Horizontal isolation, Horizontal drawout type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assembly of 3 vacuum interrupters , with each pole individually encapsulated by epoxy insulations and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks for insertion.
M & L PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in pole foundations etc complete all as specified and directed.
M & L PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts etc including provision of necessary form work complete all as specified and directed.
Material and Labour PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in pole / strut coping complete all as specified and directed.
Material and Labour anti climbing devices, spikes type fabricated out of M.S. bars ( round,square and flat ) including nuts,bolts,Washers and clamps in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
Material and Labour cross arms,supports, clamps etc fabricated from structural steel section including nuts, bolts , washers, welding, bending ( cold or hot ) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one primer coat of red oxide zinc chromate one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Material and Labour single disc porcelain, vitreous white/brown insulator 255 mm dia and 145 mm height assembly for tension with tension clamps for conductor working pressure 11000 volts complete all as specified and directed.
Material and Labour pin type insulator porcelain, vitreous white/brown including one galvanised MS spindle nut and two GI washers of size 150 mm height, 150 mm dia for 11000 volts complete all as specified and directed.
Material and Labour for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT,25x 20 cm size complete all as specified and directed.
Supply and fix jumpers in red/yellow/blue colour for HT lines/connections made from aluminium conductor single core PVC insulated cable of suitable size complete including winding wires, aluminium tapes etc complete all as specified and directed.
Supply and fix gang operated air break switches with vertical isolation complete with drop out fuse unit triple pole, 12 insulator type, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for rating 400 Amps, 11000 volts complete with GI operating pipe of heavy duty grade of suitable length complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete all as specified and directed. Note :- Earth lead strip 32 x 6 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
Material and Labour for route indicator for HT cable disc type of size 150 mm dia CI, 8 mm thickness embossed with " MES HT CABLE" and fixed on angle iron 35 x 35 x 5 mm, 600 mm long as directed and painted in anti corrosive brown color paint incl PCC 1:2:4 type B-1 foundation block of size 300 x300 x 300 mm, duly fixed in ground complete all as specified and as directed.
Material and Labour for horizontal boring under road for passing cables manually or using mechanical devices complete all as specified and as directed.
Material and Labour GI tubes 100 mm bore light grade for cable protection on poles/walls/under road/culvert etc. complete all as specified and directed.
Bharat Enterprises
R B TRADERS
Shivalik Enterprises
M/S BALWINDER SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .