Loading…
Loading…
Tender Value
₹21.3 Cr
EMD Value
₹42.6 L
Closing Date
3 Jun 2026, 3:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
+ Capital Works)
S AND T
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of SGCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Bid Capacity: The tender/technical bid will be evaluated based on bid capacity formula detailed as Annexure-VI of GCC april 2022
6 conditions · 4 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The bid must comply technical conditions of tender.
Provision of Dual detection arrangement by providing MSDAC in parallel with the existing DC track circuits at Bhusawal RC Cabin, at Bhusawal Yard, in Bhusawal B & C cabin and in Manmad Yard on BSL division.
BSL-N-SNT-07-2026-27
BSL-N-SNT-07-2026-27
Open
Works - General
6 Months
Jalgaon, Maharashtra
₹0
₹42.6 L
3 Jun 2026
9 May 2026
20 May 2026
271 items across 4 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,06,49,388.71 | ||
| — | 7.00 | — | — | ||
| Supply of Relay rack assembly complete with scaffolding, fixtures and accessories including MS Bars for fixing of relay plug board, string rods, fuse strips with bracket, 11 way Bus bars with cover and mounting brackets, runway for cable/wires, frame, base assembly etc. Siemens type & as per extant practice on C.Rly. Typical part list as per Annexure-II and Rack arrangement as per sketch no SK-727 and Rack plan as approved by Engineer in charge. (Inspection by Consignee) | — | — | — | 2,50,484.5 | |
| — | 32.00 | — | — | ||
| Supply of Tag blocks 200/160/120 way with polycarbonate cover as per IRS S 77- 2006.(Rev.1) RDSO DRG. No.SA 24751, SA 24752 & SA 24753. Requirement of each type shall be specified by Engineer-in-charge.(Inspection by RDSO) | — | — | — | 45,953.92 | |
| — | 7.00 | — | — | ||
| Supply of Main cable Termination rack complete with scaffolding, fixtures & accessories including square bars for mounting 8-way terminal blocks, ladder, string rods, frame, base assembly, insulators, J bolt , nut/bolts & fasteners, backelite sheet, etc. Siemens type and as per extant practice of Central Railway. Typical part list as per Annexure-III and rack arrangement shall be as per sketch No.SK-727 with latest alterations.(Inspection by Consignee) | — | — | — | 2,14,809.56 | |
| — | 4.00 | — | — | ||
| Supply of PVC Indoor cable 1x60x0.6mm dia color coding of insulation of inner core shall be in six color viz Blue, Red, Grey, Green,Brown & Black conforming to IRS 76/89 (Amd.3) or latest.(Inspection by RDSO) | — | — | — | 12,29,229.6 | |
| — | 4.00 | — | — | ||
| Supply of PVC Indoor cable 1x40x0.6mm dia color coding of insulation of inner core shall be in eight color viz Blue, Red, Grey, Green, Brown, Black, Yellow & White conforming to IRS 76/89 (Amd.3) or latest. (Inspection by RDSO) | — | — | — | 8,06,402.56 | |
| — | 4.00 | — | — | ||
| Supply of PVC indoor cable 1x24x1 mm dia. Color coding of insulation of Inner conductor shall be in eight colour viz, Blue, Red, Grey, Green, Brown, Black, Yellow & white confirming to IRS 76/89 (Amd. 3) or latest.(Inspection by RDSO) | — | — | — | 11,63,045.76 | |
| — | 21.00 | — | — | ||
| Supply of Indoor Jumper wire of various colour as per Railways standard practice of type ATC 1x0.6 mm dia. Conforming to IRS/76/89 (Amd.3) of latest. (Inspection by RDSO) | — | — | — | 1,92,540.6 | |
| — | 3.50 | — | — | ||
| Supply of Indoor Jumper wire ATC 1x1 mm dia. Conforming to IRS/76/89 (Amd.3) of latest. (Inspection by RDSO) | — | — | — | 47,846.05 | |
| — | 4.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x2.5 Sq.mm (50 conductor each diameter 0.25 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.70 mm nominal conductor resistance 7.98 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. (Inspection by RDSO) | — | — | — | 1,85,708.4 | |
| — | 5.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x6 Sq.mm (84 conductor each diameter 0.30 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. (Inspection by RDSO) | — | — | — | 4,49,231.9 | |
| — | 4.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x10 Sq.mm (80 conductor each diameter 0.40 +/- 0.01) as per IS 694/2010. with latest amendment if any with insulation thickness of 1.0 mm nominal conductor resistance 1.91 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest. (Inspection by RDSO) | — | — | — | 5,62,727.84 | |
| — | 4.00 | — | — | ||
| Supply of PVC flexible copper cable single core, multistrand 1x16 Sq.mm (126 conductor each diameter 0.40 +/- 0.01) as per IS 2465/1984 & IS: 694/2010. with latest amendment if any with insulation thickness of 1.0mm nominal conductor resistance 1.121 ohms/km and test parameters are as per IRS (S) 76/89 (Amd.3)or latest.(Inspection by RDSO) | — | — | — | 8,35,968.64 | |
| — | 14.00 | — | — | ||
| Supply of wire 16/0.2 (Blue, Red, Grey, yellow, Brown, Black, White as per site engineer instruction) finolex/polycab/delton make. IRS:S-76/89 (Amd.3), BS: 4808 Part-2. Wire to be procured from RDSO approved vender. (Inspection by RDSO) | — | — | — | 92,594.6 | |
| — | 6.00 | — | — | ||
| Supply of Battery charger self regulating floor mounting type with 230 V AC single phase input and output 24 V DC, 30 A as per spec.IRS.S.86/2000 (Amd.4) with latest amendments. (Inspection by RDSO) | — | — | — | 1,76,773.44 | |
| — | 90.00 | — | — | ||
| Relay base plate complete with amphanol's, code pins, fixing screws etc. suitable for Metal to Metal K-50 mini groups/ECRs of Siemens Make or functional equivalent of other makes.Note : Relay Base plates, are to be procured from Relay manufacturer (OEM). Manufacturer's Certificate for procurement and guarantee in this regard should be furnished. The payment to be released only after Manufacturer's Certificate is submitted. (Inspection by RDSO) | — | — | — | 69,454.8 | |
| — | 105.00 | — | — | ||
| Supply of Plug In type Relay Metal to Metal type neutral relay mini groups ( AC Immunised-1) Siemens make (No.RSSK 30/0078-1) (Ref.IRS:S46/74 with Amd.1 & firms specification). or functional equivalent without base plates. Contact configuration 5F/3B or 6F/2B or 4F/4B to be specified by Engineer incharge. (Inspection by RDSO) | — | — | — | 9,11,284.5 | |
| — | 140.00 | — | — | ||
| Supply of QNA1 AC immunized relay, 8F-8B, 24 VDC along with plug, board, retaining clip and connectors conforming to BRS:931A,IRS:S60/78 with Amendment no.1 , IRS:S34/68 with Amendment no.6 & IRS:S23/88 with Amendment no.1 (Inspection by RDSO) | — | — | — | 5,54,906.8 | |
| — | 8.00 | — | — | ||
| Supply of universal fail safe block interface as per RDSO specification no.RDSO/SPN/147/2005 or latest, IRS:S-104/2012 suitable to work on OFC/1Quad cable for IB signalling (required relays will be supplied by the railways before commissioning). (Inspection by RDSO) | — | — | — | 79,40,276.64 | |
| — | 8.00 | — | — | ||
| Supply of Automatic media changeover of Modems working on redundant channels for data transmission on OFC/Quad/Micowave Radio. (Inspection by RDSO) | — | — | — | 2,83,426.56 | |
| — | 8.00 | — | — | ||
| Supply of Modems for UFSBI (For use with secondary media and OFC/Quad.) (Inspection by RDSO) | — | — | — | 5,27,752.64 | |
| — | 8.00 | — | — | ||
| Supply of MODEM compatible with existing UFSBI system to work on back up media (either VF channel on OFC P/Mux or 2 Mbps E1 channel from STM or direct dark single mode optic fibre cable upto 30 km distance. (Inspection by RDSO) | — | — | — | 5,81,966.56 | |
| — | 200.00 | — | — | ||
| Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92. With holder 1.6 A (System, Rapid or Malnad Make). (Inspection by Consignee) | — | — | — | 16,520 | |
| — | 200.00 | — | — | ||
| Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92. With holder 0.6 A (System, Rapid or Malnad Make). (Inspection by Consignee) | — | — | — | 16,048 | |
| — | 400.00 | — | — | ||
| Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92. Without holder 1.6 A (System, Rapid or Malnad Make). (Inspection by Consignee) | — | — | — | 9,440 | |
| — | 80.00 | — | — | ||
| Supply of INDICATIVE TYPE OF FUSE INSERTS. IRS S:-78-92. Without holder 0.6 A (System, Rapid or Malnad Make). (Inspection by Consignee) | — | — | — | 1,888 | |
| — | 25.00 | — | — | ||
| Resin cored wire as per specification No.IS:1921-1975 with Alloying element percentage as 63% SN (Tin) nd / 37% Pb (Lead) with percentage of various impurities not exceeding the values Sb (Antimony 0.2% maximum, Cu (Copper) 0.1% maximum, As (Arsenic) 0.05% maximum, Fe (Iron) 0.02% maximum & other impurities mainly AI, Zn & Cd shall be limited. The flux shall be free from corrosive action as per clause 5.2 & flux percentage may be used as per requirement. (Inspection by Consignee) | — | — | — | 31,801 | |
| — | 160.00 | — | — | ||
| Lacing thread rolls, black, wax coated (100 mtrs) (Inspection by Consignee) | — | — | — | 10,761.6 | |
| — | 17.00 | — | — | ||
| Design, fabrication and supply of fuse Auto changeover system for 32 Nos external non detorating type fuses or 'G' type fuses from 0.6A Amp to 4A Amp capacities used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO) | — | — | — | 4,64,328.82 | |
| — | 13.00 | — | — | ||
| Design, fabrication and supply of fuse Auto changeover system for 24 Nos external non detorating type fuses or 'G' type fuses from 4 A to 10 Amp capacities generally used for point operation circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one card. As per RDSO spec. RDSO/SPN/209/2012 Ver.2.0 or latest amendment if any. (Inspection by RDSO) | — | — | — | 5,17,142.08 | |
| — | 120.00 | — | — | ||
| Supply of Phenolic 10mm thick sheet, grade P3 in standard size of 1.22x1.22 Mtr as per spec. No. IS 2036 of 1995. (Inspection by RITES) | — | — | — | 6,58,298.4 | |
| — | 15000.00 | — | — | ||
| Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4., SA-23745 Alt.5, SA-23746, SA-23748 Alt.4, & SA-23756 Alt.3. (Inspection by RITES) | — | — | — | 11,50,500 | |
| — | 340.00 | — | — | ||
| Supply of cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4, SA- 23749 & Spec No.IRS S 75/2006 Rev.02 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO) | — | — | — | 57,772.8 | |
| — | 340.00 | — | — | ||
| Supply of round head type non detoriating type low voltage cartridge fuse as per specn No. IRS/S/78/92 with latest amendments - 2A/4A/6A capacity (Inspection by RDSO) | — | — | — | 24,874.4 | |
| — | 40.00 | — | — | ||
| Supply of Tik-tak, piano type switches, 5 A (as per IS Specification). (Inspection by Consignee) | — | — | — | 1,416 | |
| — | 40.00 | — | — | ||
| Supply of three pole plug and socket 5 Amp (as per IS Specification). (Inspection by Consignee) | — | — | — | 9,676 | |
| — | 50.00 | — | — | ||
| Supply of Apparatus case with godown locks with detachable handle on both the doors. Single Case as per Drg No SK 783-1 & 2. with latest alteration. (Inspection by RITES) | — | — | — | 8,40,868 | |
| — | 25.00 | — | — | ||
| Supply of Apparatus case with godown locks with detachable handle on both the doors. Half Case as per Drg No SK 783-1 & 2. with latest alteration. (Inspection by RITES) | — | — | — | 3,32,966.5 | |
| — | 80.00 | — | — | ||
| Supply of earth electrode assembly as per Drg.No.CR/S&T/SK-815. (Inspection by RITES) | — | — | — | 89,774.4 | |
| — | 230.00 | — | — | ||
| Maintenance Free Earth as per RDSO/SPN/197/2008 or latest consisting of : 1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250micron & UL listed & marked-01 No. (2) Earth enhancement compound RDSO Approved in sealed bag of 10 kgs - 03 No. (3) Copper strip 150 x 25 x 6mm - 02 No (4) Copper Strip 300 x 25 x 6mm- 01 No (5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15Mtr Approx. (Inspection by RDSO) | — | — | — | 42,53,109.4 | |
| — | 790.00 | — | — | ||
| Supply of 35 Sq. mm. multistrand single core PVC insulated copper for connecting earth bus bar to earth electrode. (Inspection by RDSO) | — | — | — | 3,40,253 | |
| — | 6.00 | — | — | ||
| Supply of Microprocessor based universal earth resistance sensing unit 12 channel AC/DC. As per RDSO/SPN/256/2002 with latest amendments. (Inspection by RITES) | — | — | — | 8,40,006.6 | |
| — | 100.00 | — | — | ||
| SUPPLY of Electronic timers for DAC reset arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC(642X A programmable electronic timer switch) make. (Inspection by RDSO) | — | — | — | 2,81,666 | |
| — | 110.00 | Per Functional Vital Bit | — | ||
| Supply of Multi strand twin twisted core shielded cable of 28 - 30/0.2 mm for Axle counter as per IRS spec. 76/89 with Amendment No.03 or latest amendments, if any. (Unit: Nos. = Per 100 meter) (Inspection by RDSO) | — | — | — | 16,36,258.8 | |
| — | 780.00 | — | — | ||
| Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239 PT. 1/2004 or latest with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. (Inspection by RITES) | — | — | — | 8,35,723.2 | |
| — | 900.00 | — | — | ||
| Supply of DWC HDPE pipe with one snap fit coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver 1.1 with Amd.1 or latest. (Inspection by RITES) | — | — | — | 3,05,856 | |
| — | 28000.00 | — | — | ||
| Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection by RITES) | — | — | — | 62,44,560 | |
| — | 5000.00 | — | — | ||
| Supply of RCC pipes half round of size 300 mm dia outer and 250 mm dia internal 1 mtr long matching to IS No.458/2003 amendment-1 with Rev.4. (Inspection by RITES) | — | — | — | 21,53,500 | |
| — | 9000.00 | — | — | ||
| Supply of modular terminal block of 2.5 sq. mm 2 IN 2 OUT type disconnect type terminal along with as per RDSO SPN/189/2004 Rev 3.0. The current capacity of 16 Amps and more. The terminal should have marking at centre to view description from front. Material to be procured from RDSO approved firms only. (Inspection by RDSO) | — | — | — | 10,62,000 | |
| — | 220.00 | — | — | ||
| Supply of DIN Channel for the terminals 1 Mtrs each. (Inspection by Consignee) | — | — | — | 48,545.2 | |
| — | 400.00 | — | — | ||
| Supply of End plates for modular terminal block. (Inspection by Consignee) | — | — | — | 9,440 | |
| — | 400.00 | — | — | ||
| Supply of End Clamp for modular terminal block. (Inspection by Consignee). | — | — | — | 7,080 | |
| — | 360.00 | — | — | ||
| Supply of Marker Card as per customer spec (10x10). (Inspection by Consignee) | — | — | — | 30,160.8 | |
| — | 200.00 | — | — | ||
| Fuse terminals block with LED indication up to 2.5 sqmm screw type one in one out (suitable for (400 mA, 630mA, 1 A, 1.6 A, 2 A, 4A, 6.3 A & 10 A ) as per RDSO SPN/189/2004 Ver.03 or latest . (without fuse) (Inspection by RDSO) | — | — | — | 37,052 | |
| — | 690.00 | — | — | ||
| End plate for through terminal block with LED indication. (Inspection by Consignee) | — | — | — | 9,770.4 | |
| — | 680.00 | — | — | ||
| Fuse links of (400 mA, 630mA, 1 A, 1.6 A, 2 A, 4A, 6.3 A & 10A) (Inspection by RDSO) | — | — | — | 29,688.8 | |
| — | 12.00 | — | — | ||
| Supply of Permanently Lubricated HDPE Telecom duct of size 50/42 mm and accessories as per latest Specification TEC GR No. GR/TX/CDS-008/03March 11 with latest amendment" for OFC cable of size 24 fibre armoured in length of 1000 mtr/roll. Duct to be supplied from TEC approved sources. (Inspection by RITES) | — | — | — | 8,99,641.44 | |
| — | — | — | 2,14,56,882.82 | ||
| — | 7.00 | — | — | ||
| Installation of Relay Rack Assembly including IDF pillars if any complete with wall supports, scaffolding, ladders, runway for cables, Relay/Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on C.Railways & the instructions of Rly engineer at site. | — | — | — | 10,391.08 | |
| — | 7.00 | — | — | ||
| Installation of Cable Termination Rack Assembly complete including wall supports, scaffolding, Disconnecting links/ARA terminal, 96 way tag block with tag block cover & other necessary accessories etc. The work shall be done as per approved plan, extant practice on C.Railways & the instructions of Rly engineer at site. | — | — | — | 8,458.24 | |
| — | 16000.00 | — | — | ||
| Termination of cable cores on ARA terminal/disconnecting links in the cable termination rack. This includes all associated works of pulling out the cable from under ground, peeling off insulation, dressing of Cable core supported on sting rods with contractors own material. The work shall be done as per instructions of Rly engineer at site. | — | — | — | 1,69,920 | |
| — | 32.00 | — | — | ||
| Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination 60/40 core cable/flexible wire on tagblock/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel throughing work. The work shall be done as per approved plan, extant practice on C.Rly & the instruction of Rly. Engineer at site. (Unit: Numbers=Tag Block) | — | — | — | 19,559.68 | |
| — | 8000.00 | — | — | ||
| Circuit wiring/jumpering as per circuit diagrams in the relay racks/IDF rack tagblocks. This includes preparation of jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder resin core to be supplied by contractor for soldering of jumper wires. Soldering of jumper wires to be done after completion of testing by Railways. (Unit: Numbers=Jumpers) | — | — | — | 1,03,840 | |
| — | 160.00 | — | — | ||
| Relay Contact break test of indoor relay wiring. Contractor shall depute Engineer, Supervisor & wiremen technically qualified to carryout contact break testing as per approved circuit diagrams. Firm Engineer to sign circuit diagrams for break testing after carrying out the test in presence of Railway's site supervisor/Engineer. (Unit: Numbers=A3 Size Circuit per sheet) | — | — | — | 53,052.8 | |
| — | 8.00 | — | — | ||
| Installation, testing and commissioning of Automatic Media Changeover of modems working on redundant channels for data transmission on OFC / Quad (Unit - one pair Qty 1 set) | — | — | — | 2,11,739.2 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-April2022_merged20.05.2024.pdf
ATTACHMENT
Drawing SOR
ATTACHMENT
GCC_April-2022_2022__POLICY_27_04_22.pdf
ATTACHMENT
CorrectionslipGCC13032026.pdf
ATTACHMENT
Annexure A
ATTACHMENT
MMRSIP_compressed.pdf
ATTACHMENT
BHUSAVALSIPREV-BDT.28.04.25_compressed.pdf
ATTACHMENT
Tenderdoc07-26-27.pdf
ATTACHMENT
Annexure-ASafety-CriticalSignalingItemsbyRDSORSDte26.09.2025.1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .