| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹9.4 L+₹62,890 (7.17%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹9.6 L+₹83,060 (9.48%)Rejected-Finance | L3 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | ANAND REFRIGERATION L2 | AMK ENTERPRISES L1 | SRI AYYAPPA ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster on any description including removing old APP membrane, scrubbing down with water and prepare to receive new plastering. | 500 | SQM | 90 ₹45,000 | 75 ₹37,500 Lowest | 80 ₹40,000 |
| 2.00 | Material and labour Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed. | 150 | RM | 85 ₹12,750 | 70 ₹10,500 Lowest | 95 ₹14,250 |
| 3.00 | M&L 12 mm thick Plaster on RCC roof slab and sunken portion with CM ( 1:3 ) using water proofing compound @ 200ml/ bag of cement shall be carried out as specified. (Note : WPC shall be measured and paid separately) | 500 | SQM | 230 ₹1,15,000 | 200 ₹1,00,000 Lowest | 220 ₹1,10,000 |
| 4.00 | M&L for PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate as in roof padding / sunken floors and similar work using WPC @ 200ml/ Bag of cement complete all as specified. (Note : WPC shall be measured and paid separately) | 12.5 | CUM | 5,500 ₹68,750 | 5,300 ₹66,250 Lowest | 5,650 ₹70,625 |
| 5.00 | Supply only liquid water proofing compound | 30 | LTR | 120 ₹3,600 | 110 ₹3,300 Lowest | 150 ₹4,500 |
| 6.00 | M&L for Applying oil bound bituminous primer @ 0.20 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not.less than 4.0 Kg/Sqm reinforced with non Woven polyester matt weighing not.less than 150o Centigrade , having tensile strength of 650 N/5 cm and 350 N/5 cm in longitudnal and transverse direction respectively of the reinforcement, tearing strength of 180N by torch application with minimum 10 cm side over lap and 15cm over lap, applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.2 Kg /sqm over the membrane a coat of solar reflective bituminous aluminium paint @ 0.10 Kg per sqm all as specified. Note :- removing and refxing of earth strip, roof area of solar panels also need to done int his job. | 500 | SQM | 1,250 ₹6,25,000 | 1,200 ₹6,00,000 Lowest | 1,275 ₹6,37,500 |
| 7.00 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store boreof pipe in 20 mm. | 50 | RM | 40 ₹2,000 | 30 ₹1,500 Lowest | 50 ₹2,500 |
| 8.00 | Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store boreof pipe in 25 mm. | 32 | RM | 45 ₹1,440 | 30 ₹960 Lowest | 60 ₹1,920 |
| 9.00 | Refixing old steel tubing and connection in new or old position (walls, ceiling, floors, etc.) bore of pipe in 20mm . | 35 | RM | 60 ₹2,100 | 50 ₹1,750 Lowest | 75 ₹2,625 |
| 10.00 | Refixing old steel tubing and connection in new or old position (walls, ceiling, floors, etc.) bore of pipe in 25mm . | 20 | RM | 70 ₹1,400 | 60 ₹1,200 Lowest | 90 ₹1,800 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
27 Mar 2026, 6:00 pmClosed
Shri Shubham Yadav, AEE
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
REPAIR TO LEAKAGE SEEPAGE TO OTM AND MD ACCN AT MYSORE UNDER AGE (I) AF CHIMNEY HILLS
2026_MES_755362_1
8918/E8
Open Tender
Civil Works
Item Rate
120 days
Mysore
REPAIR TO LEAKAGE SEEPAGE TO OTM AND MD ACCN AT MYSORE UNDER AGE (I) AF CHIMNEY HILLS
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF Chimney Hills, Bangalore
₹16,000
Yes
1 Jun 2026
6 Mar 2026
3 Apr 2026
6 Mar 2026
27 Mar 2026
20 Mar 2026
6 Mar 2026 - 13 Mar 2026
Taking down cement plaster on any description including removing old APP membrane, scrubbing down with water and prepare to receive new plastering.
Material and labour Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed.
M&L 12 mm thick Plaster on RCC roof slab and sunken portion with CM ( 1:3 ) using water proofing compound @ 200ml/ bag of cement shall be carried out as specified. (Note : WPC shall be measured and paid separately)
M&L for PCC (1:2:4) type B-0, using 12.5 mm graded stone aggregate as in roof padding / sunken floors and similar work using WPC @ 200ml/ Bag of cement complete all as specified. (Note : WPC shall be measured and paid separately)
Supply only liquid water proofing compound
M&L for Applying oil bound bituminous primer @ 0.20 Kg/Sqm and providing 4mm thick APP modified water proofing membrane weighing not.less than 4.0 Kg/Sqm reinforced with non Woven polyester matt weighing not.less than 150o Centigrade , having tensile strength of 650 N/5 cm and 350 N/5 cm in longitudnal and transverse direction respectively of the reinforcement, tearing strength of 180N by torch application with minimum 10 cm side over lap and 15cm over lap, applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.2 Kg /sqm over the membrane a coat of solar reflective bituminous aluminium paint @ 0.10 Kg per sqm all as specified. Note :- removing and refxing of earth strip, roof area of solar panels also need to done int his job.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store boreof pipe in 20 mm.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store boreof pipe in 25 mm.
Refixing old steel tubing and connection in new or old position (walls, ceiling, floors, etc.) bore of pipe in 20mm .
Refixing old steel tubing and connection in new or old position (walls, ceiling, floors, etc.) bore of pipe in 25mm .
S&L ' Medium grade' galvanised Tubes 20 mm dia, with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., fitting and fixed complete to walls and ceilings or laid in floors.
S&L ' Medium grade' galvanised Tubes 25 mm dia, with all tube fillings (such as bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc., fitting and fixed complete to walls and ceilings or laid in floors.
S&F in Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed , bore of pipe 20mm.
Disconnecting existing tanks, setting aside (or lowering if required ) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position . Capacity of tank upto 1000Lts.
S&F in Repairs PVC Rotational moulded polyethylene water storage tanks 500 Liter (cylindrical vertical with closed top) hoisted and fixed in position all as specified and Dismantling water tanks and removing to store.
S&F in Repairs PVC Rotational moulded polyethylene water storage tanks 1000 Liter (cylindrical vertical with closed top) hoisted and fixed in position all as specified and Dismantling water tanks and removing to store.
Removing building materials etc. to a distance of n exceeding 5 KM ,beyond the lead included in the rates, including loading, unloading and stacking at the destination.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tender8918.pdf
Tender Documents • 0.79 MB
BOQ_846062.xls
BOQ • 0.30 MB
8918corrigendum1.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .