Loading…
Loading…
Tender Value
₹41.1 L
EMD Value
₹82,276
Closing Date
8 Jun 2026, 6:00 pm2d left
Executive Engineer PHED Distt. Div. Jaisalmer
Executive Engineer PHED Distt. Div. Jaisalmer
Repairing of 6 6 KV Electric Panal Board Soft Starter Capacitor Scada and EMI Works and Strenngthening of Electric Swithyard At Mohangarh Headworks For Supply of UWSS JaisalmerDistrict Jaisalmer.
2026_PHCJO_564808_1
NIB NO 04/2026-27
Open Tender
Civil Works - Water Works
90 days
Jaisalmer
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer PHED Distt. Div. Jaisalmer
₹82,276
Yes
4 Jun 2026
4 Jun 2026
9 Jun 2026
4 Jun 2026
8 Jun 2026
4 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | PWD Electric BSR 2022 PHED REVISED BSR 2023 | - | - | - | - | BI01010001010000000000000515BI0100001115 |
| 2 | 500.8.3.10Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. . - Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 | - | Each | 6,272 | - | BI01010001010000000000000515BI0100001116 |
| 3 | 8.19P & F of 240 / 415 V Electronic ON - OFF Timer 3 -30 Sec / 12 - 120 Sec including making Connection etc. as required. All as per pre approved by Engineer in charge. | - | Each | 1,938 | - | BI01010001010000000000000515BI0100001117 |
| 4 | 23.5.1SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated 304 (NonFerrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for gas tank. Vacum Interrupter of VCB should be RMU Manufacturer's own make. Each feeder of RMU should have voltage presence indicator. . and compring of followings:- 1
no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio
50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1 nos. Fault Passage indicator,-Right angle boots for all the feeder Modules All the type test certificates as per IEC from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A"
attached with this BSR - Non Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch | - | Each | 4,38,067 | - | BI01010001010000000000000515BI0100001118 |
| 5 | 15.4.1Providing & Fixing of 1200 mm sweep BLDC technology power saving ceiling fan which can withstand on votage fluctuations from 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed minimum 330 RPM ( tolerance as per IS:374 2019 ) THD less then 10% and complete with down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe up to 80 cm , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. | - | Each | 3,378 | - | BI01010001010000000000000515BI0100001119 |
| 6 | 15.12.4Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening
including making connections testing etc. as required. All as per pre approved by Engineer in charge. - 600 mm sweep(700 / 900 RPM) | - | Each | 10,559 | - | BI01010001010000000000000515BI0100001120 |
| 7 | 6.1.2.2Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. Double pole MCB(With B/C curve tripping Characteristics) - 6 A to 32 A rating | - | Each | 566 | - | BI01010001010000000000000515BI0100001121 |
| 8 | 2.32 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover | - | Each | 1,243 | - | BI01010001010000000000000515BI0100001122 |
| 9 | 2.19.32.19 Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694: 1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making
connection etc.
2.19.3 3 core 10.0 Sq.mm | - | Mtr | 484 | - | BI01010001010000000000000515BI0100001123 |
| 10 | 2.20.42.20 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
2.20.4 35.0 Sq.mm, 3.5 core | - | Mtr | 379 | - | BI01010001010000000000000515BI0100001124 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
TD_4.pdf
Tender Documents • 2.00 MB
BOQ_1005249.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid