Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC Being the lowest and reasonable bidder | |
| 2 | L2₹18.4 L+₹35,165 (1.95%)Rejected-AOC | L2 | Rejected-AOC Being the other than lowest bidder | |
| 3 | L3₹19.6 L+₹1.6 L (8.65%)Rejected-AOC 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L3 | Rejected-AOC Being the other than lowest bidder | |
| 4 | L4₹25.2 L+₹7.2 L (39.9%)Rejected-AOC | L4 | Rejected-AOC Being the other than lowest bidder | |
| 5 | L5₹28.6 L+₹10.6 L (58.9%)Rejected-AOC | L5 | Rejected-AOC Being the other than lowest bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Nagrota
HQ CWE Nagrota Co 56 APO
REPAIR/REPLACMENT OF DG SETS, SECURITY LIGHT, PANEL AND OTHER MISC ITEMS AT 213 TRANSIT CAMP UNDER GE NAGROTA
2023_MES_613871_2
CWE/NGT-22/2023-24
Open Tender
Civil Works
Item Rate
182 days
Transit Camp
As per NIT and tender docs
8 documents required · 8 mandatory
₹500
Yes
GE Nagrota
₹70,000
Yes
26 Dec 2023
7 Oct 2023
4 Nov 2023
7 Oct 2023
28 Oct 2023
14 Oct 2023
7 Oct 2023 - 14 Oct 2023
Amount
Taking down security light fiting HPSV / HPMV /HPMH/Post top lanterns/flood light/LED light fittings etc of any capacity from any height any situation and re-fixing/ re-hanging the same in existing location or other location (as directed) after carrying out repair works on light fittings including testing complete all as specified and directed by Engineer-in-Charge. Note :(i) The rate quoted for the above item shall be deemed to be included for neccessary charges for replacement of the all defective parts/fittings but cost of fittings viz: ballast of any type, ignitor, holder, lamp/tube/LED Lamp of any type, capacities required will be measured & paid separately under appropriate items of Sch 'A' here in after.
Supply and fix in replacement of LED Lamp 30 Watt pin type suitable for fix in batton holder complete. Make: CG/Wipro/Bajaj/Surya/Havells
S&F for lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and Fixing in replacement of old burnt constant current driver suitable for LED security light/Flood light fitting of 25 to 60 W capacity complete all as specified and directed by Engr in Charge
Supply and Fixing in replacement of old burnt constant current driver suitable for LED security light/Flood light fitting of 72 to 100 W capacity complete all as specified and directed by Engr in Charge
Supply and Fixing in replacement of old burnt constant current driver suitable for LED security light/Flood light fitting of 120 to 180 W capacity complete all as specified and directed by Engr in Charge
Supply and Fixing in replacement of unserviceable burnt surge protection device of capacity 10 kv complete suitable for security light fitting of any capacity complete all as specified and directed by Engr- in- Charge
Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 30 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support terminal should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box(sintex make) conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- ourgoing MCBs ( 3 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable incl taking down old unsv complete all as specified and directed. Make: Swadeep -02EC5kW3P , or Equivalent in Indoasian /Legrand
S&F of 90 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The housing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc including taking down old unserviceable light fittings complete all as specified.
S&F of 60 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 6600 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc including taking down old unserviceable light fittings complete all as specified.
S&F of 120W LED Flood Light luminaire made up of Matt black ptextured powder coated pressure Die Cast aluminum housing and frame with heat resistant toughened clear glass fixed with SS screw/ Anti dust exposed lens, sturdiness and embossed brand name/ logo name of manufacturer on fixture . The luminaire should have a minimum system lumen output of 14400 lumens and 120 Watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a sysytem life of 50000 hours @ 70 % lumen maintenence , Ingress protection of IP 66 (lamp and gear compartment ) and Mechanical impact resistance ratinfg of IK>=07. The fixture driver should have an operating voltage range of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india .LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters including complete electrical connection and testing with fixing arrangement on pole or wall including taking down unserviceable light fittings complete all as specified.
Supply & Fix IP65 rated LED Post Top light fittings 40 watt with moonlight effect and efficient light distribution complete with electrical connection arrangement.
Supply and fixing Junction box made of SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 100 A Capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator, and MCB SP 6 A 10 KA 240V -01 No. with fixing arrangement fixed properly to pole/fixed on wall with MS Clamps 25x5 mm and nut and bolts complete all as specified and directed by the Engineer-In-Charge.
Supply & Fix street light brackets fabricated out of medium grade GI pipe of 50 mm dia, 1.5mtr long bent to shape suitable for street light fittings with two sets of clamps made out of mild steel flat iron suitable for fixing on HT/LT poles with nuts, bolts and washers all as directed including dismantling the existing brackets etc complete all as directed.
S & F in repair MCB TPN 16- 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified
S & F in repair MCB SPN 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified
S & F in repair MCB SP 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified
S & L cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cables heavy duty with standard aluminium conductor,1100 volts grade,cross sectional area 3.5 core 35 Sqmm .Note : Excavation, returning and refilling will be measured and paid separately.
All as per ser No 18 but 25 Sqmm 4 core
All as per ser No 18 but 16 Sqmm 4 core
All as per ser No 18 but 10 Sqmm 4 core
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3m in depth for foundation, etc or not exceeding 10 Sqm on plan and exceeding 1.5m but not exceeding 3m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete.
M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete.
Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete.
Sand cushioning with fine dry unwashed sand in trenches for protection of cables complete. Note:- Punned thickness of sand shall be measured.
M&L for Old size sub class ‘B’ bricks, laid in trenches as cable covers complete (Note :- old serviceable bricks will be reused)
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete, Including disconnecting and taking out old damage PCC poles/struts of any size complete all as directed .
M&L for Aluminium conductor, steel reinforced of any size on LT Poles including straining,binding with insulators with Al/copper binding wire with insulators as in over head conductors, providing PVC Sleeves for jumper fixed as in repairs, complete all as specified and directed.
Taking down service wire from street light poles & providing new 1100 V Grade PVC insulated,aluminium conductor & overall PVC sheathed in service connection with 2 single core cables of size 6 Sqmm & connecting to light fittings/tertminal boxes
Taking down service wire from street light poles & providing new 1100 V Grade PVC insulated,aluminium conductor & overall PVC sheathed in service connection with 2 single core cables of size 10 Sqmm & connecting to light fittings/tertminal boxes
Repair, servicing and comprehensive/ preventive maintenance of Engine part of DG set any make of Capacities 40KVA to 63 KVA, which include removal unserviceable worn out spare parts, cleaning of all components with necessary cleaning material, replacement of all spare parts and gaskets as per manufacturer spare part kit, engine oil change including overhauling, re-assembling of complete engine setting, timing setting, bleaching and engine testing, replacement of diesel filter,Engine oil filter, lubricating oil, rubber hose pipe, V belt, oil pipe, diesel pipe, repair kit, burnt oil part etc. and tightening of nuts bolts, washers greasing etc for proper running of DG sets all as directed at site complete. Note (i) Spares part, engine oil, fillters shall be measured and paid for separately. (ii) Cost of oiling, greasing, tightening of nuts, bolts and minor work etc are included in the unit rate quoted by the contractor.
Material & labour for replacement of Engine oil 20 W 40 during servicing of DG sets.
Supply and fix in replacement of Engine oil filter for DG set upto 63 KVA capacity.
Supply and fix in replacement of Diesel filter for DG set upto 63 KVA capacity.
Supply and fix in replacement of Air filter for DG set upto 63 KVA capacity.
Supply and fix in replacement of unserviceable fuel pipe for DG set upto 63 KVA capacity.
Supply and fixing in replacement of asbestos rope any dia wrapped over the exhaust pipe complete
Repair and overhauling of self starter 12 V/ 24 V of DG set, upto 63 KVA Capacity, after opening nuts and bolts complete carrying out repair/ maint work for smooth functioning, testing complete and refixed same place as directed at site. Note :- (i) (Spare parts will be measured and paid separately)
Supply and fix in replacement of unserviceable Field Coil to self starter 12V/24V of DG set upto 63 KVA complete.
Supply and fix in replacement of unserviceable Armature winding to self starter 12V/24V of DG set upto 63 KVA complete.
Supply and fix in replacement of unserviceable Clutch assembly to self starter 12V/24V of DG set upto 63 KVA complete
Supply and fix in replacement of unserviceable Carbon Brushes to self starter 12V/24V of DG set upto 63 KVA complete
Supply and fix in replacement of Pinion Assembly to self starter 12V/24V of DG set upto 63 KVA complete
Repair and overhauling of dynamo of any DG set, upto 63 KVA capacity after opening nuts and bolts complete carrying out repair/ maint work for smooth functioning, testing complete and refixed same place as directed at site. Note :- (i) (Spare parts will be measured and paid separately).
Supply and fix in replacement of unserviceable Carbon Brushes to Dynmo of DG set upto 63 KVA complete
M & L for Armature rewinding to Dynmo of DG set upto 63 KVA complete
Supply and fix in replacement of unserviceable Field Coil to Dynmo of DG set upto 63 KVA complete
Disconnecting and dismantalling the alternator unit of DG Set from the base plate of the DG set and transporting the workshop for repair, dismantaling the unit , further seperation the armature from the startor carefully, cutting and taking out the burnt winding of the alternator carefully, cleanning the slot and duly applying the insulation and assembling the stampings inserting the positiion in the startor incl applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of the same gauge and the same number of turns as that of existing one including replacement of carbon brushes tapping the winding and bring out the coil conncetion for production of three phase 415 V 50 HZ AC supply preheating the winding and applying insulating warnish and drying the winding in oven and assembling the unit and transporting back to insatallation and fix on base plate and coupling with the DG set and testing complte all as specified and directed
Repair/maintenance of DG set Manual/AMF LT Panel by cleaning of all carbonized / corroded parts, checking of wiring and battery charging system if any in the panel replacement of lugs, single core copper cable 2.5 /4 Sqmm etc as required and making the panel serviceable of any size / any make including replacement of voltmeter, ammeter, power factor meter, indicator frequency meter etc all as directed by Engineer-in-Charge. Note :- (i) (Spare parts like Voltmeter, Ammeter,Power Factor meter, Indicator lamp, Frequency Meter and MCB/MCCB will be measured and paid separately). (ii) Cost of Lugs, tightening of nuts, bolts replacement of wiring and other minor work etc are included in the unit rate quoted by the contractor.
Supply and fix in replacement of unserviceable Voltmeter, range 0 to 500 V into LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unserviceable Ammeter, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unserviceable Frequency meter, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unserviceable Power Factor meter, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unserviceable Indicator Lamp RYB, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unserviceable MCCB TP 63 Amps adjustable thermal and fixed magnetic ,16 KA, 415 volts complete in LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unserviceable MCCB TP 100 Amps ,adjustable thermal and fixed magnetic ,16 KA, 415 volts complete in LT Panel of DG set upto 63 KVA complete
Supply and fixing of battery terminal bolt type suitable for 180 AH battery as directed by Engineer-in-Charge.
Supply and fixing battery lead of copper conductor 25 Sqmm single core fitted with lead terminal on one side and other side with brass or lead terminal ( length of wire not less than1.5 Mtrs) as per site required and connection as directed by Engineer-in-Charge
Supply and fix in replcement of unserviceable battery 12 Volts,150 AH including filling of required capacity electrolyte and transportation complete all as directed by Engineer-in-Charge.
Supply and fix in replcement of unserviceable battery 12 Volts,180 AH including filling of required capacity electrolyte and transportation complete all as directed by Engineer-in-Charge.
Supply and fill electrolyte distiled water to battery complete all as directed by Engineer-in-Charge.
Taking out injection nozzle from DG set transportation to authorised service centre for repairing and replacement of necessary parts calibration and re-fixing to DG set and testing complete all as directed by Engineer-in-Charge.
Material and Labour for servicing and overhauling and repairing complete alternator greasing cleaning of all stator and rotor, re-varnishing the stator and rotor winding with superior quality of varnish including heating and baking the same. Re-assembling the complete alternator, fixing in position and testing on load for the DG Set upto 63 KVA capacity Note :-(i) Cost of greasing, varnish, tightening of nuts, bolts replacement of wiring and other minor work etc are included in the unit rate quoted by the contractor.
Supply & Fixing in replacement MCCB 4 pole 160 amps 50Hz 415 volts adjustable type with reputing cap 25KA
Supply & Fixing in replacement MCCB 4 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA
S &F on load Change Over switch side handle operated 415 V 4 pole of capacity 160 amps
S &F on load Change Over switch side handle operated 415 V 4 pole of capacity 100 amps
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25M deep below natural ground level ) with top edge of plate not less than 1.5M below normal ground level, surrounded from all sides alternate packed layer of char coal dust and comman salt and electrode connected with galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR part I including necessary earth work in type strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways GI medium grade 20 mm dia pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up tp 7.5 mtr complete all as directed including testing complete on completion.
All as per sl item No. 73 above but using 32x6 mm GI earth strip as a earth lead & 40 mm dia light grade GI protection pipe complete all as specified & directed Note for item No. 73 & 74 (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM included the quoted rate. (ii) The qty above the 7.5 RM shall be measured & paid separetely
Note:- Schedule of credit Rs. 79,998.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
Nitika electricals and engineers works
Prakash Trading Corporation
G M ENGINEERING SERVICES
PAWAN KUMAR GOVT. CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .